999 resultados para Ajuste oclusal
Resumo:
The project has as objective to adjust the model QUAL2K to “Ribeirão Claro” river to evaluate the behavior of OD and DBO when are simulated the following sceneries: (i) implantation of a hypothetic wastewater station treatment that treats all the effluent thrown nowadays in the body of water; (ii) increase of withdrawal flow of DAAE to public supply and (iii) increase of nowadays flow of wastewater throwing, being the two last caused for the population increasing. The results obtained allowed to conclude that the model QUAL2K presented a good adjustment to the variable OD and a reasonable adjustment to the variable DBO, being that the same was suitable to the simulation of the sceneries proposed.
Resumo:
This work presents as the central theme the management conducted by the Public Relations' professional regarding the custom relations' channels, focusing on Ombudsman. Its main objective is to discuss, reflect and establish a parallel between these activities, highlighting the importance of these channels on the organization’s communication and relationship process with their customers. Split in three chapters, it begins the discussion about the terminology in Ombudsman, from the meaning and concept of the terms to the comparison with other relationship means with the customer. It is a part of the study a brief history about organizations and their changes over the years, emphasizing the importance of customers and relations for the success of the modern day organizations, considering the Public Relations in this context. The discussion concludes establishing a parallel between the Ombudsman channels and the meaning of public relations in its management, regarding the relevancy of the subject in a highly competitive scenario, in which the customer/person, as a change agent, can be the responsible for the success or failure of organizations. The study tries to focus on showing the importance of the skills and competencies of the Public Relations for the fore mentioned channels, which are not well defined yet.
Resumo:
This paper proposes a mechanical device to adapt a simple model of hospital bed used in the Emergency Department at Santa Casa of Guaratinguetá, allowing the bed’s height adjustment with electromechanical drive. This adaptation aims to introduce improvements in the routine work of nurses and reduce ergonomic problems stemming from repetitive strain during the transfer of patients to stretchers and wheelchairs, as well as providing more comfort to the bedridden patient. The device is mainly composed of: an electric induction motor used to drive the engine, a steel spindle with square thread, which allows axial displacement of the bed, a transmission system with pulleys and belt, which transmits power supplied by the motor to the spindle. The mechanism allows the height of the bed is regulated between 400 and 800 mm. The estimated implementation cost of this proposal is lower than the acquisition cost of a commercial hospital bed with the same features, which confirms the feasibility of the proposed solution
Resumo:
In hospitals, health professionals may face different situations and problems. By following them, it is remarkable that one of the difficulties is related to the support provided by the facilities to carry out their work. This also affects the quality of treatment offered to patients. One of the points of improvement that could be studied is hospital beds. The Fawler's simplest hospital bed type, used in most Brazilian public hospitals, is designed with an ergonomic average height that offers a default position for analysis and treatment of patients. There is no possibility of adjusting the height of those beds, and hence there is a limitation in this regard since that height is fixed, but the physical structures of the workers and patients may vary widely and there may be a conflict when there are people too large or small involved in this process. Beyond that, studies by experts show that beds with height adjustment decreases the muscular effort and improve the movement quality of the spine of nursing staff, reducing the force on certain vertebrae and also the ergonomic risk. Of course, patient comfort is also affected accordingly. As the beds made with height adjustment are very expensive, this study aims to design a device to adapt the not adjustable beds. The project must be viable from an economic and mechanic standpoint, being able to adapt both old and new simplest Fawler hospital bed models, since their dimensions are similar. The final result shows that it is possible to adapt such beds using the designed concept at a viable cost. Furthermore, this concept could be applied in other bed types or objects that have hollow feet
Resumo:
Pós-graduação em Zootecnia - FCAV
Resumo:
Patients are looking for esthetic and functional changes when seeking orthodontic treatment and expect the remaining of a stable occlusion. Occlusion stability is one of the goals of the orthodontist; however, dental relationships changes in long-term can occur leading to a relapse of the treatment. Teeth and shape of arches tend to return to the original form, been the retention phase important after the appliance removal, even after several years of post-treatment. This article approaches a submission of a clinical case of Class II division 1 treated with extraction of premolars analyzing its long-term stability.
Resumo:
Purpose: The aim of this study was to compare occlusal plane angulation measured in two different types of semi-adjustable articulators with that obtained on the lateral cephalometric radiograph. Materials and Methods: 20 patients due to undergo orthognathic surgery had dental casts mounted in two different types of semi-adjustable articulators through face bow transfer from the position of the maxilla and occlusal recording to the mandible. After mounting, the inclination of the occlusal plane in the articulators was measured and compared with the inclination measured at on both articulators and compared with the inclination measured on the lateral cephalometric radiographs and between the articulators themselves. The results obtained werestatistically analyzed. Results: Mean angulation values for the Bio Art (7.55º) and Kavo (-5.70º) articulators differ by 13.25º, which is statistically significant (p=0.00). When individually compared to the lateral cephalometric radiograph (5.075º), the Bio Art articulator showed more similar angulation values, with a difference of 2.475º, while the Kavo articulator presented a difference of 10.775º. Conclusion: Neither of the models of semi-adjustable articulators accurately reproduced the inclination of the maxillary occlusal plane of patients with dentofacial deformities; the difference between the two articulators tested and the lateral cephalometric radiograph was lower for the Bio Art than for the Kavo articulator.
Resumo:
The composite resin is the material of election for direct restorations in posterior teeth currently. The restorative dentistry aims to improve each day the material and facilitate the restorative technique. This paper describes the technique of occlusal matrix made to speed up and preservation the occlusal surface of a first molar tooth affected by caries lesion. A new resin-based composite was used called Silorane, which may be placed in larger increments due the material has low shrinkage and polymerization stress. The use of occlusal matrix associated with a low shrinkage resin composite can simplify the clinical work, and result in a restoration with excellent reproduction of anatomical.
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Objective: the aim of this study was to evaluate the influence of occlusal veneering material in single fixed implant-supported crowns through the 3-D finite element method. Material and methods: Four models were fabricated using the Rhinoceros 4.0, SolidWorks, and InVesalius softwares. Each model represented a block of mandibular bone with an external hexagon implant of 5 mm x 10 mm and different veneering materials including NiCr (1), porcelain (2), composite resin (3), and acrylic resin (4). An axial load of 200 N and an oblique load of 100 N were applied. Results: model (2) with porcelain veneering presented a lower stress concentration for the NiCr framework, followed by the composite resin and acrylic resin. The stress distribution to the implant and bone tissue was similar for all models. Conclusions: there is no difference of stress distribution to the implant and supporting structures by varying the veneering material of a single implant-supported prosthesis.
Resumo:
Objective: the aim of this study was to evaluate the influence of occlusal veneering material in single fixed implant-supported crowns through the 3-D finite element method. Material and methods: Four models were fabricated using the Rhinoceros 4.0, SolidWorks, and InVesalius softwares. Each model represented a block of mandibular bone with an external hexagon implant of 5 mm x 10 mm and different veneering materials including NiCr (1), porcelain (2), composite resin (3), and acrylic resin (4). An axial load of 200 N and an oblique load of 100 N were applied. Results: model (2) with porcelain veneering presented a lower stress concentration for the NiCr framework, followed by the composite resin and acrylic resin. The stress distribution to the implant and bone tissue was similar for all models. Conclusions: there is no difference of stress distribution to the implant and supporting structures by varying the veneering material of a single implant-supported prosthesis.
Resumo:
O objetivo deste trabalho é compreender a etapa de ajuste no contexto da gestão do portfólio de projetos, destacando sua relação com os processos de categorização e balanceamento. A pesquisa realizada tem caráter qualitativo, sendo a abordagem adotada o estudo de caso longitudinal. A pesquisa foi desenvolvida em uma empresa do setor químico brasileiro. As evidências, de várias fontes, foram coletadas através de entrevistas, documentos e dados dos sistemas corporativos. Para a compreensão do portfólio de projetos da empresa foram coletados e analisados dados de mil projetos realizados entre 2001 e 2005. Os resultados indicam que maior atenção é dada à etapa de seleção, negligenciando a etapa de ajuste. A adoção de ferramentas de balanceamento permitiu evidenciar lacunas e fontes de desbalanceamento no portfólio de projetos, promovendo o debate entre os tomadores de decisão no que concerne ao viés introduzido pelos critérios adotados na etapa de seleção e levantando a necessidade de introdução de uma sistemática de ajuste e balanceamento. Observou-se que sem uma adequada categorização dos projetos da empresa seria difícil promover a análise de balanceamento.