877 resultados para ANTERIOR CINGULATE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the lack of electromyographic researches on sport and programmes of physical conditioning, we can say that it is necessary to reexamine some exercises routinely used in the programmes of physical conditioning. Thus, the trapezius and serratus anterior muscles were studied electromyographically so that we could evaluate the validity in some ways of execution of the frontal-lateral cross, dumbbells exercises for the development of these muscles. We analyzed 24 male volunteers, 18 to 25 years old, using a 2-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. For the execution of the exercise it was used a supine bench, a straight board and two bars of 40 cm made of light wood. The results showed that TS acted preferentially in standing modality and in the inclined supine modality, however with activity levels that do not justify its inclusion in physical fitness programmes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The trapezius and serratus anterior muscles were studied in four modalities of rowing exercises executed with two grips, middle and closed, in comparison with the four different modalities of frontal-lateral cross, dumbbells exercise. It was used 24 male volunteers, 18 to 25 years old using a 2-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. The results showed that TS acted in a higher significant way in all the modalities of rowing than in the supine lateral raise, inclined supine lateral raise and reverse supine lateral raise, dumbbells exercises, and demonstrated no standing frontal-lateral cross, dumbbells. The SI acted more significantly difference among all the execution modalities of rowing and the inclined supine lateral raise, dumbbells exercises than in all the rowing exercises; even though the activity levels do not make us suggest them as an excellent group of exercises for the development of this muscle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Because the lack of textbooks based on electromyographic studies in the area of exercises for physical conditioning, the authors proposed to study the trapezius (upper portion) (TS) and the serratus anterior (lower portion) (SI) muscles during the execution of four different modalities of rowing exercises with middle grip in 24 male volunteers, 18 to 25 years old. For the recordings, it was used a two-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. For the movements, a supine bench and a 120 cm-long bar made of low weight wood were used. The results showed that TS acted significantly in upright, sitting and inclined rowing, justifying its inclusion in physical conditioning programmes, while SI, in spite of acting preferentially in upright and sitting rowing, presented activity levels which do not justify its inclusion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Because the lack of specialized textbooks, the select of basic exercises for physical conditioning programmes is based on empirical knowledge. This fact led the authors to propose the study on electromyographic activity of the trapezius (upper portion) (TS) and the serratus anterior (lower portion) (SI) muscles in rowing exercises with closed grip in three different modalities. The tests were carried out with 24 male volunteers, 18 to 25 years old, by using a two-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. For exercises execution, a long bar made of light wood was used. TS acted significantly in the three different modalities, that is, upright, sitting and bent over, while SI acted preferentially in upright and sitting rowing exercises, justifying their inclusion as basic exercises in physical conditioning programmes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Because the lack of specialized textbooks on the select and indication of basic exercises for physical conditioning programmes, an electromyographic study of the trapezius (upper portion) (TS) and the serratus anterior (lower portion) (SI) muscles in rowing exercises with middle and closed grip in three different modalities, upright, sitting and bent over was performed. The tests were carried out with 24 male volunteers, 18 to 25 years old, by using a two-channel TECA TE 4 electromyograph and Hewlett Packard surface electrodes. For exercises execution, a supine bench, a straight board and a 1,20 m-long bar made of light wood were used. The results showed that TS acted preferentially with closed grip sitting and bent over modalities, and presented no difference among the grips for upright rowing. SI acted preferentially with closed grip in all modalities, however, with activity levels that do not justify its indication for physical conditioning programmes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electromyographic activity of the shoulder muscles deltoid - anterior portion (DA) and pectoralis major - clavicular portion (PMC) was tested on 24 male volunteers using a 2 channel TEC A TE4 electromyograph and Hewlett Packard surface electrodes during the execution of four different modalities of frontal-lateral cross, dumbbells exercises. The results showed that all of the tested exercises developed high levels of action potential for both muscles. So, we jusfity the indication of all of them for physical fitness programmes for DA and PMC. Some suggestions to the use of the tested exercises are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The action potential level for shoulder muscles deltoid-anterior portion (DA) and pectoralis major-clavicular portion (PMC) determined by four different modalities of execution of rowing exercises, each one with two different grips, was recorded. These were compared with the action potential level determined for the same muscles by four different modalities of execution of the frontal-lateral cross, dumbbells exercises. Twenty-four male volunteers were examined using a 2 channel TECA TE4 electromyograph and Hewlett Packard surface electrodes. The statistic analysis showed significant (p<0,05) superiority for all the frontal-lateral cross, dumbbells exercises in comparison to all rowing exercises for the PMC, for the DA this generalized supremacy was not observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The muscles deltoid-anterior portion (DA) and pectoralis major-clavicular portion (PMC) were analysed to establish the muscular behavior and intensity patterns, as well to evaluate the connected participation of these muscles during supine and frontal elevation exercises. Twenty-four male volunteers were examined using a 2-channel TECA TE4 electromyograph and Hewlett Packard surface electrodes. Our results showed low levels of activity to PMC in frontal elevation exercises, whereas to DA the levels were very high. In the supine exercise, the action potential levels developed by the PMC were always lower than those presented by DA, however, with action simultaneity. Some suggestions to the use of the tested exercises are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effective activity of the pectoralis major and deltoideus anterior muscles in horizontal flyer exercises with external loads of 25, 50, 75 and 100% of the maximum load was studied in 11 male volunteers. The electromyographic analysis was done by using MEDI-TRACE-200 surface electrodes connected to a biological signal acquisition mode coupled to a PC/AT computer. The electromyographic signals were processed and the values obtained were normalized through maximum voluntary isometric contraction. It was statistically observed that in all types and loads of this exercise, the muscles presented significant differences in the concentric and eccentric phases. In the concentric phase, when different loads were compared, the muscles were more active with 75 and 100% of the maximum load, while in the eccentric phase, higher activity was observed with 100% of the maximum load. By analyzing each load effect in the concentric phase, it was verified that the muscles on the left side were more active than those on the right side with 25, 75 and 100% of the maximum load.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine whether intercommissural width is a reliable guide for the selection of maxillary denture teeth width. Materials and Methods: Casts were made of 160 subjects from 4 different racial groups. Locations of intercommissural width landmarks (the corners of the mouth) were made on the subjects and transferred to the casts. The distances between the corners of the mouth and the distal of the canines were measured on the casts and compared. Results: A weak correlation was found between the distal of the canines and the distance between the corners of the mouth in the 4 racial groups. Conclusion: The use of the corners of the mouth for the selection of artificial teeth is generally inaccurate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inverted flying exercise with external loads of 25, 50, 75 and 100% of each individual maximum load in the pectoralis major and deltoideus anterior muscles was electromyographically analyzed in eleven male volunteers, using surface electrodes MEDI-TRACE-200 connected to a biological signals acquisition module coupled to a PC/AT computer. Electromyographic signals were processed and the effective values obtained were standardized through maximum voluntary isometric contraction. When the concentric phase of each muscle with the same load was statistically compared with the eccentric phase, it was observed that for all loads all the muscles presented significant electromyographic difference, and that the concentric phase was always higher. By analyzing the different loads for each muscle, it was noticed that in the concentric phase all the muscles presented significant electromyographic activity, being it higher with maximum load. When the effect of each load on different muscle in the concentric and eccentric phases was analyzed, the muscles presented a distinct activity profile.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Selecting artificial teeth for edentulous patients is difficult when pre-extraction records are not available. Various guidelines have been suggested for determining the width of the maxillary anterior denture teeth. This study was undertaken to evaluate the use of the nasal width as a guide for the selection of proper width maxillary anterior denture teeth in four racial groups of the Brazilian population. Materials and Methods: One hundred and sixty subjects (40 Whites, 40 Mulattos, 40 Blacks, and 40 Asians) were selected. Using a sliding caliper, the nasal width and the intercanine distance were measured. The Pearson product-moment correlation coefficient was used to determine the relationship between the above measurements. A prediction was made of the percentage of subjects of the White, Mulatto, Black, and Asian populations in which the selection error due to the clinical application of the method of the nasal width would be within 0 to 2 mm, within 2 to 4 mm, and greater than 4 mm. Results: The four racial groups showed a weak correlation between the intercanine distance and the nasal width. In 39.7% of the White, 55.7% of the Mulatto, 81.9% of the Black, and 48.2% of the Asian populations, errors greater than 4 mm would be present with the use of the nasal width. Conclusions: The correlation found between the intercanine distance and the nasal width was not high enough to be used as a predictive factor. The relationship between natural tooth width and artificial tooth width as predicted by the nasal width showed that the nasal width method is not accurate for all the studied groups. Copyright © 2006 by The American College of Prosthodontists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to a shortage of textbooks with specific data on muscular activity concerning physical conditioning and sports, we analysed electromyographically the muscles pectoralis major and deltoideus anterior, bilaterally, in inclined flying exercises, during the concentric and eccentric phases, with external loads of 25, 50, 75 and 100% of the maximum load. The electromyographic analysis was performed in eleven male volunteers with MEDITRACE-200 surface electrodes connected to a six-channel biologic signal acquisition module coupled to a PC/AT computer. The electromyographic signals were processed and the obtained effective values were normalized through maximum voluntary isometric contraction. Statistically, the results showed that all the muscles studied presented significant differences between the concentric and the eccentric phases, with higher electromyographic activity during the concentric phase. By analysing the different loads for each muscle in both phases, significant electromyographic activity was observed for all muscles. When the effect of each load on each muscle during the concentric phase was analysed, it was noticed that the muscles on the left were more active than those on the right side, while in the eccentric phase the muscles had different behavior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We made some measurements from the region of the symphysis menti in 308 dried mandibles; 247 belong to the collection of the cranial museum of the discipline of Anatomy of the UNIFESP- Escola Paulista de Medicina- EPM and 61 belong to the didactic laboratory of the discipline of Anatomy from the Faculdade de Odontologia de Araraquara- UNESP, Brasil. On the dentate mandibles, the highest value founded was of 43,46 mm and the lowest of 22,67 mm. On the edentate mandibles, the highest value founded was of 37,24 mm and the lowest of 6,22mm. We hope that with the following discoveries we could contribute to a better knowledge of the symphysis menti region, not only to the professionals in Surgery and Implantology areas, but the industrials of related areas, to the confection of instruments used in these practices. © 2007 Sociedad Chilena de Anatom•br>.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this study was to assess the existence of myofunctional alterations before and after first premolar extraction in Class II/1 malocclusion patients that could endanger the long-term dental arch stability. Materials and Methods: The study was performed by means of morphological, functional and electromyographic analyses in 17 Class II/1 malocclusion patients (group T) and 17 Class I malocclusion patients (group C), both groups with 12-30-year age range (mean age: 20.93 ± 4.94 years). Results: Data analyzed statistically by Student's t-test showed a significant decrease in the maxillary and mandibular dental arch perimeters after orthodontic treatment (p<0.05). The Kruskal-Wallis test analyzed data from tongue posture at rest and during swallowing, not showing significant differences after treatment (groups Tb and Ta) (p>0.05). However, group T differed significantly from group C (p<0.05). The electromyographic data showed that the anterior right and left suprahyoid muscles acted synergistically in both groups, while having a lower myoelectric activity in group T during swallowing. Conclusions: Myofunctional alterations observed after the orthodontic treatment in Class II/1 malocclusion seemed to jeopardize the long-term orthodontic stability, making recurrence possible. Further research should be conducted to compare electromyographic data before and after orthodontic treatment in order to corroborate the results of the present investigation.