452 resultados para ANEURYSM, RUPTURED


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Symptomatic cervical spinal arteriovenous malformations (AVMs) located on the anterior aspect of the spinal cord are rare and surgical removal of these AVMs presents considerable challenges and risks. Surgical techniques to date have usually been by posterior approach and lateral dissection around the cord or via midline myelotomy, both approaches involving cord manipulation and retraction and in the latter, dissection through the spinal cord. We present two teenage patients with symptomatic anteriorly placed mid to high cervical spinal AVMs and associated aneurysm in which excision of the AVMs and aneurysm was performed by an anterior approach using vertebrectomy/corpectomy. The first case had a small perimedullary glomus-type AVM with an aneurysm on the anterior aspect of the cord at the C3/4 level; excision was performed using a single level vertebrectomy/corpectomy, the patient remaining neurologically intact. The second case had a medium-sized juvenile AVM with an aneurysm, both perimedullary and intramedullary, centred at the C5/6 level; excision was performed using a two-level vertebrectomy/corpectomy with no deterioration in the marked pre-operative tetraparesis, which at long-term follow up had improved and stabilised. Anterior approaches have been recently described for treatment of anteriorly placed cervical arteriovenous fistulas (AVFs) and an intramedullary haemangioblastoma, but not as yet for spinal AVMs. These are the first two reported cases of anteriorly situated cervical AVMs successfully removed surgically by an anterior approach and with good neurological outcomes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To report the authors' initial experience with carotid artery stent-grafts in a comparatively large patient series for the treatment of acute bleeding and impending rupture or the prevention of distal embolization. MATERIALS AND METHODS: This retrospective study was approved by the institutional review boards and performed according to HIPPA standards. Twenty-five patients were treated with 27 carotid artery stent-grafts (Gore Viabahn, n = 10; Bard Fluency, n = 9; polytetrafluoroethylene-covered Palmaz, n = 5; and Wallgraft, n = 3). Thirteen stent-grafts were placed in patients with carotid blow-out syndrome (including three patients with carotid-airway fistula), 12 in patients with either pseudoaneurysm (n = 9) or true aneurysm (n = 3), and two in patients with intractable high-grade bare stent restenosis. RESULTS: The technical success rate was 100% (27 of 27 cases). No acute procedural transient ischemic attacks or strokes occurred. Procedural dissections occurred in two of the 27 cases (7.4%). Short-term complications occurred in three of the 27 cases (11%) (repeat hemorrhage, n = 2; common carotid artery occlusion, n = 1). The overall patient mortality rate was 36% (nine of 25 patients, all with carotid blow-out syndrome). Six-month follow-up in 15 of the 16 living patients demonstrated widely patent stent-grafts. Two patients with pseudoaneurysm also demonstrated patent stents at 18- and 33-month follow-up. CONCLUSIONS: Stent-grafts may be useful in the treatment of carotid artery bleeding syndrome, aneurysm, and stenosis, with a high procedural success rate in selected cases. The results of mid-term follow-up are encouraging, but results of long-term follow-up must be evaluated in future studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Standard endovascular repair of abdominal aortic aneurysm (AAA) has been shown to be associated with significant advantages compared with conventional surgery in the perioperative time frame related to the minimally invasive nature of the procedure. Given the encouraging long-term results of endovascular AAA repair, this method is increasingly applied to patients with complex AAA anatomies. The present article reviews the indications for branched and fenestrated endografts in various aortic pathologic processes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To quantify the interobserver variability of abdominal aortic aneurysm (AAA) neck length and angulation measurements. MATERIALS AND METHODS: A total of 25 consecutive patients scheduled for endovascular AAA repair underwent follow-up 64-row computed tomographic (CT) angiography in 0.625-mm collimation. AAA neck length and angulation were determined by four blinded, independent readers. AAA neck length was defined as the longitudinal distance between the first transverse CT slice directly distal to the lowermost renal artery and the first transverse CT slice that showed at least a 15% larger outer aortic wall diameter versus the diameter measured directly below the lowermost renal artery. Infrarenal AAA neck angulation was defined as the true angle between the longitudinal axis of the proximal AAA neck and the longitudinal axis of the AAA lumen as analyzed on three-dimensional CT reconstructions. RESULTS: Mean deviation in aortic neck length determination was 32.3% and that in aortic neck angulation was 32.1%. Interobserver variability of aortic neck length and angulation measurements was considerable: in any reader combination, at least one measurement difference was outside the predefined limits of agreement. CONCLUSIONS: Assessment of the longitudinal extension and angulation of the infrarenal aortic neck is associated with substantial observer variability, even if measurement is carried out according to a standardized protocol. Further studies are mandatory to assess dedicated technical approaches to minimize variance in the determination of the longitudinal extension and angulation of the infrarenal aortic neck.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: This retrospective study was conducted to determine whether a low-volume contrast medium protocol provides sufficient enhancement for 64-detector computed tomography angiography (CTA) in patients with aortoiliac aneurysms. METHODS: Evaluated were 45 consecutive patients (6 women; mean age, 72 +/- 6 years) who were referred for aortoiliac computed tomography angiography between October 2005 and January 2007. Group A (22 patients; creatinine clearance, 64.2 +/- 8.1 mL/min) received 50 mL of the contrast agent. Group B (23 patients; creatinine clearance, 89.4 +/- 7.3 mL/min) received 100 mL of the contrast agent. The injection rate was 3.5 mL/s, followed by 30 mL of saline at 3.5 mL/s. Studies were performed on the same 64-detector computed tomography scanner using a real-time bolus-tracking technique. Quantitative analysis was performed by determination of mean vascular attenuation at 10 regions of interest from the suprarenal aorta to the common femoral artery by one reader blinded to type and amount of contrast agent and compared using the Student t test. Image quality according to a 4-point scale was assessed in consensus by two readers blinded to type and amount of contrast medium and compared using the Mann-Whitney test. Multivariable adjustments were performed using ordinal regression analysis. RESULTS: Mean total attenuation did not differ significantly between both groups (196.5 +/- 33.0 Hounsfield unit [HU] in group A and 203.1 +/- 44.2 HU in group B; P = .57 by univariate and P > .05 by multivariable analysis). Accordingly, attenuation at each region of interest was not significantly different (P > .35). Image quality was excellent or good in all patients. No significant differences in visual assessment were found comparing both contrast medium protocols (P > .05 by univariate and by multivariable analysis). CONCLUSIONS: Aortoiliac aneurysm imaging can be performed with substantially reduced amounts of contrast medium using 64-detector computed tomography angiography technology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare clinical outcomes of endovascular and open aortic repair of abdominal aortic aneurysms (AAAs) in young patients at low risk. It was hypothesized that endovascular aneurysm repair (EVAR) compares favorably with open aneurysm repair (OAR) in these patients. MATERIALS AND METHODS: Twenty-five patients aged 65 years or younger with a low perioperative surgical risk profile underwent EVAR at a single institution between April 1994 and May 2007 (23 men; mean age, 62 years+/-2.8). A sex- and risk-matched control group of 25 consecutive patients aged 65 years or younger who underwent OAR was used as a control group (23 men; mean age, 59 years+/-3.9). Patient outcomes and complications were classified according to Society of Vascular Surgery/International Society for Cardiovascular Surgery reporting standards. RESULTS: Mean follow-up times were 7.1 years+/-3.2 after EVAR and 5.9 years+/-1.8 after OAR (P=.1020). Total complication rates were 20% after EVAR and 52% after OAR (P=.0378), and all complications were mild or moderate. Mean intensive care unit times were 0.2 days+/-0.4 after EVAR and 1.1 days+/-0.4 after OAR (P<.0001) and mean lengths of hospital stay were 2.3 days+/-1.0 after EVAR and 5.0 days+/-2.1 after OAR (P<.0001). Cumulative rates of long-term patient survival did not differ between EVAR and OAR (P=.144). No AAA-related deaths or aortoiliac ruptures occurred during follow-up for EVAR and OAR. In addition, no surgical conversions were necessary in EVAR recipients. Cumulative rates of freedom from secondary procedures were not significantly different between the EVAR and OAR groups (P=.418). Within a multivariable Cox proportional-hazards analysis adjusted for patient age, maximum AAA diameter, and cardiac risk score, all-cause mortality rates (odds ratio [OR], 0.125; 95% CI, 0.010-1.493; P=.100) and need for secondary procedures (OR, 5.014; 95% CI, 0.325-77.410; P=.537) were not different between EVAR and OAR. CONCLUSIONS: Results from this observational study indicate that EVAR offers a favorable alternative to OAR in young patients at low risk.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Patent foramen ovale (PFO) has been linked to migraine, and several retrospective studies reported an improvement in migraine prevalence or frequency after PFO closure for other reasons, mostly for secondary prevention of paradoxical embolism or following diving accidents. We investigated the outcome of patients undergoing PFO closure solely for migraine headaches refractory to medical treatment. METHODS: Seventeen patients (age 44 +/- 12 years; 76% female; one atrial septal aneurysm) underwent percutaneous PFO closure using the Amplatzer PFO Occluder (AGA Medical Corporation, Golden Valley, MN). An 18-mm device was used in two patients, a 25-mm device in 13, and a 35-mm device in two. The interventions were solely guided by fluoroscopy, without intraprocedural echocardiography. RESULTS: All implantation procedures were successful. There were no peri-procedural complications. Contrast transesophageal echocardiography after Valsalva maneuver at 6 months showed complete PFO closure in 16 patients (94%), whereas a minimal residual shunt persisted in one (6%). During 2.7 +/- 1.5 years of follow-up, no deaths and no embolic events occurred. After PFO closure, migraine headaches disappeared in four patients (24%), and improved in eight additional patients (47%). Three patients (18%) reported a decrease of their headaches by 75%, three patients (18%) a decrease of 50%, and two patients (12%) a decrease of 25%, while headaches remained unchanged in five patients (29%). No patient experienced worsening headaches. Moreover, the prevalence of migraine with aura decreased from 82 to 24% (P = 0.002). CONCLUSIONS: These results suggest that percutaneous PFO closure durably alters the spontaneous course of shunt associated migraine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Percutaneous closure of patent foramen ovale (PFO) is generally performed using intra-procedural guidance by transoesophageal (TEE) or intracardiac (ICE) echocardiography. While TEE requires sedation or general anaesthesia, ICE is costly and adds incremental risk, and both imaging modalities lengthen the procedure. METHODS: A total of 825 consecutive patients (age 51 +/- 13 years; 58% male) underwent percutaneous PFO closure solely under fluoroscopic guidance, without intra-procedural echocardiography. The indications for PFO closure were presumed paradoxical embolism in 698 patients (95% cerebral, 5% other locations), an embolic event with concurrent aetiologies in 47, diving in 51, migraine headaches in 13, and other reasons in 16. An atrial septal aneurysm was associated with the PFO in 242 patients (29%). RESULTS: Permanent device implantation failed in two patients (0.2%). There were 18 procedural complications (2.2%), including embolization of the device or parts of it in five patients with successful percutaneous removal in all cases, air embolism with transient symptoms in four patients, pericardial tamponade requiring pericardiocentesis in one patient, a transient ischaemic attack with visual symptoms in one patient, and vascular access site problems in seven patients. There were no long-term sequelae. Contrast TEE at six months showed complete abolition of right-to-left shunt via PFO in 88% of patients, whereas a minimal, moderate or large residual shunt persisted in 7%, 3%, and 2%, respectively. CONCLUSIONS: This study confirms the safety and feasibility of percutaneous PFO closure without intra-procedural echocardiographic guidance in a large cohort of consecutive patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Sex differences in patients with patent foramen ovale (PFO) and cryptogenic stroke have not been systematically analyzed. We aimed to determine sex influences on demographics, vascular risk factors, clinical manifestations, stroke location, and clinical outcome. METHODS: One thousand two hundred eighty-eight consecutive patients with ischemic stroke or transient ischemic attack (TIA) were admitted to a single stroke center. All patients underwent a complete stroke workup including clinical examination, standard blood tests, cerebral and vascular imaging, transesophageal echocardiography, and 24-hour electrocardiography. In 500 patients, no definite etiology could be established (cryptogenic stroke/TIA). Of them, 167 patients (107 men and 60 women, mean age 52 +/- 13 years) had an PFO. RESULTS: The prevalence of PFO in patients with cryptogenic stroke or TIA was higher in men than in women (38% vs 28%, P = .014). Stroke severity and the prevalence of risk factors did not differ between the 2 sexes. There was an independent association between male sex and stroke location in the posterior cerebral circulation (OR 3.0, 95% CI 1.4-6.5, P = .006). Men and women did not differ in respect to PFO grade, prevalence of right-to-left shunt at rest, or coexistence of atrial septal aneurysm. Clinical outcome at 3 months was similar in both sexes. CONCLUSION: Patent foramen ovale was more prevalent in men than in women with cryptogenic stroke. There were no sex influences on age, risk factors, echocardiographic characteristics of PFO, or clinical outcome. Male sex was independently associated with stroke in the posterior cerebral circulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goal of this study was to assess the feasibility, safety and success of a system which uses radiofrequency energy (RFE) rather than a device for percutaneous closure of patent foramen ovale (PFO). METHODS: Sixteen patients (10 men, 6 women, mean age 50 years) were included in the study. All of them had a proven PFO with documented right-to-left shunt (RLS) after Valsalva manoeuvre (VM) during transoesophageal echocardiography (TEE). The patients had an average PFO diameter of 6 +/- 2 mm at TEE and an average of 23 +/- 4 microembolic signals (MES) in power M-mode transcranial Doppler sonography (pm-TCD), measured over the middle cerebral artery. An atrial septal aneurysm (ASA) was present in 7 patients (44%). Balloon measurement, performed in all patients, revealed a stretched PFO diameter of 8 +/- 3 mm. In 2 patients (stretched diameter 11 and 14 mm respectively, both with ASA >10 mm), radiofrequency was not applied (PFO too large) and the PFO was closed with an Amplatzer PFO occluder instead. A 6-month follow-up TEE was performed in all patients. RESULTS: There were no serious adverse events during the procedure or at follow-up (12 months average). TEE 6 months after the first RFE procedure showed complete closure of the PFO in 50% of the patients (7/14). Closure appeared to be influenced by PFO diameter, complete closure being achieved in 89% (7/8) with a balloon-stretched diameter < or =7 mm but in none of the patients >7 mm. Only one of the complete closure patients had an ASA. Of the remainder, 4 (29%) had an ASA. Although the PFO was not completely closed in this group, some reduction in the diameter of the PFO and in MES was documented by TEE and pm-TCD with VM. Five of the 7 residual shunt patients received an Amplatzer PFO occluder. Except for one patient with a minimal residual shunt, all showed complete closure of PFO at 6-month follow-up TEE and pm-TCD with VM. The other two refused a closure device. CONCLUSIONS: The results confirm that radiofrequency closure of the PFO is safe albeit less efficacious and more complex than device closure. The technique in its current state should not be attempted in patients with a balloon-stretched PFO diameter >7 mm and an ASA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Despite advances in surgical and interventional techniques, the optimal surgical treatment of severe aortic (re) coarctation and hypoplastic aortic arch is still controversial. Anatomic repair may require extensive dissection, cardiopulmonary bypass, and deep hypothermic circulatory arrest with their inherent risks. The aim of this study was to analyze the outcome of off-pump extraanatomic aortic bypass as a surgical alternative to local repair. METHODS: From February 2000 to December 2005, ten consecutive patients (median age 20 years; range, 11 to 38 years) with severe aortic (re) coarctation (n = 4) and (or) hypoplastic aortic arch (n = 7) underwent off-pump extraanatomic aortic bypass through median sternotomy. All but three patients had undergone previous surgery for coarctation and angioplasty or stenting. Three patients underwent concomitant replacement of the ascending aorta because of an aneurysm using cardiopulmonary bypass. RESULTS: Postoperative hospital course was uneventful in all patients. There was no perioperative mortality or significant morbidity. During a mean follow-up of 48 +/- 22 months no patient required additional procedures. All patients were free of symptoms; no patient showed signs of heart failure after follow-up. At last follow-up, no patient presented with claudication, nor any patient experienced orthostatic problems due to a steal phenomenon. During follow-up, hypertension resolved in all patients with residual mild hypertension in two patients. CONCLUSIONS: Off-pump extraanatomic aortic bypass is an attractive treatment option for complex aortic (re) coarctation and hypoplastic aortic arch. Perioperative risks are minimized, hypertension is influenced favorably, and midterm survival is event-free.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors describe the use of the Cardica C-Port xA Distal Anastomosis System to perform an automated, high-flow extracranial-intracranial bypass. The C-Port system has been developed and tested in coronary artery bypass surgery for rapid distal coronary artery anastomoses. Air-powered, it performs an automated end-to-side anastomosis within seconds by nearly simultaneously making an arteriotomy and inserting 13 microclips into the graft and recipient vessel. Intracranial use of the device was first simulated in a cadaver prepared for microsurgical anatomical dissection. The authors used this system in a 43-year-old man who sustained a subarachnoid hemorrhage after being assaulted and was found to have a traumatic pseudoaneurysm of the proximal intracranial internal carotid artery. The aneurysm appeared to be enlarging on serial imaging studies and it was anticipated that a bypass would probably be needed to treat the lesion. An end-to-side bypass was performed with the C-Port system using a saphenous vein conduit extending from the common carotid artery to the middle cerebral artery. The bypass was demonstrated to be patent on intraoperative and postoperative arteriography. The patient had a temporary hyperperfusion syndrome and subsequently made a good neurological recovery. The C-Port system facilitates the performance of a high-flow extracranial-intracranial bypass with short periods of temporary arterial occlusion. Because of the size and configuration of the device, its use is not feasible in all anatomical situations that require a high-flow bypass; however it is a useful addition to the armamentarium of the neurovascular surgeon.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: The aim of this prospective study was to analyse small band-like cortical infarcts after subarachnoid haemorrhage (SAH) using magnetic resonance imaging (MRI) with reference to additional digital subtraction angiography (DSA). METHODS: In a 5-year period between January 2002 and January 2007 10 out of 188 patients with aneurysmal SAH were evaluated (one patient Hunt and Hess grade I, one patient grade II, four patients grade III, two patients grade IV, and two patients grade V). The imaging protocol included serially performed MRI with diffusion- and perfusion-weighted images (DWI/PWI) at three time points after aneurysm treatment, and cerebral vasospasm (CVS) was analysed on follow-up DSA on day 7+/-3 after SAH. RESULTS: The lesions were located in the frontal lobe (n=10), in the insular cortex (n=3) and in the parietal lobe (n=1). The band-like infarcts occurred after a mean time interval of 5.8 days (range 3-10 days) and showed unexceptional adjacent thick sulcal clots. Seven out of ten patients with cortical infarcts had no or mild CVS, and in the remaining three patients DSA disclosed moderate (n=2) or severe (n=1) CVS. CONCLUSION: The infarct pattern after aneurysmal SAH includes cortical band-like lesions. In contrast to territorial infarcts or lacunar infarcts in the white matter which develop as a result of moderate or severe proximal and/or distal vasospasm visible on angiography, the cortical band-like lesions adjacent to sulcal clots may also develop without evidence of macroscopic vasospasm, implying a vasospastic reaction of the most distal superficial and intraparenchymal vessels.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the incidence and impact of an intracerebral hematoma (ICH) on treatment and outcome in patients with aneurysmal subarachnoid hemorrhage. METHODS: Data of 585 consecutive patients with subarachnoid hemorrhage from June 1999 to December 2005 were prospectively entered in a database. ICH was diagnosed and size was measured by computed tomographic scan before aneurysm occlusion. Fifty patients (8.5%) presented with an ICH larger than 50 cm3. The treatment decision (coil, clip, or hematoma evacuation) was based on an interdisciplinary approach. Patients were stratified into good (Hunt and Hess Grades I-III) versus poor (Hunt and Hess Grades IV and V) grade, and outcome was assessed according to the modified Rankin Scale at 6 months. RESULTS: Overall, 358 patients presented in good grade, with 4 of them having ICH (1.1%); and 227 patients presented in poor grade, with 46 of them having ICH (20.3%, P < 0.01). In good-grade patients with an ICH (n = 4), a favorable outcome (modified Rankin Scale score of 0-2) was achieved in 1 patient (25%), and in 246 patients (75%) without an ICH (P = 0.053; odds ratio, 0.11). A favorable outcome was achieved in 5 poor-grade patients (12.8%) with an ICH and in 40 patients (23.7%) without an ICH (P = 0.19; odds ratio, 0.47). Time to treatment was significantly shorter in patients with an ICH than without an ICH (median, 7 versus 26 h; P < 0.001) and shortest in patients with favorable outcome (3.5 hours; P < 0.01). CONCLUSION: The current data confirm that the presence of an ICH is a predictor of unfavorable outcome. However, despite large ICHs, a significant number of patients have a good outcome. To achieve a favorable outcome, ultra-early treatment with hematoma evacuation and aneurysm obliteration seems to be mandatory.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goal of this work is to develop a magnetic-based passive and wireless pressure sensor for use in biomedical applications. Structurally, the pressure sensor, referred to as the magneto-harmonic pressure sensor, is composed of two magnetic elements: a magnetically-soft material acts as a sensing element, and a magnetically hard material acts as a biasing element. Both elements are embedded within a rigid sensor body and sealed with an elastomer pressure membrane. Upon excitation of an externally applied AC magnetic field, the sensing element is capable of producing higher-order magnetic signature that is able to be remotely detected with an external receiving coil. When exposed to environment with changing ambient pressure, the elastomer pressure membrane of pressure sensor is deflected depending on the surrounding pressure. The deflection of elastomer membrane changes the separation distance between the sensing and biasing elements. As a result, the higher-order harmonic signal emitted by the magnetically-soft sensing element is shifted, allowing detection of pressure change by determining the extent of the harmonic shifting. The passive and wireless nature of the sensor is enabled with an external excitation and receiving system consisting of an excitation coil and a receiving coil. These unique characteristics made the sensor suitable to be used for continuous and long-term pressure monitoring, particularly useful for biomedical applications which often require frequent surveillance. In this work, abdominal aortic aneurysm is selected as the disease model for evaluation the performance of pressure sensor and system. Animal model, with subcutaneous sensor implantation in mice, was conducted to demonstrate the efficacy and feasibility of pressure sensor in biological environment.