961 resultados para 720501 Defence standards and calibrations


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Economic Commission for Latin America and the Caribbean (ECLAC) Subregional Headquarters for the Caribbean, in collaboration with the World Bank, conducted a week-long Regional Workshop on Microdata Documentation and Dissemination. The workshop, which was funded by the Partnership in Statistics for Development in the Twenty-First Century (PARIS21) and the Organization for Economic Co-operation and Development (OECD), was held at the Hilton Hotel and Conference Centre in Port of Spain, Trinidad, from 26 to 30 April 2010. The main objective of the workshop was to provide training to member States on the Microdata Management Toolkit. This toolkit was developed by International Household Surveys Networks (IHSN) to assist in the documentation, dissemination and preservation of household survey, census and microdata in accordance with international standards and best practices. The training was organized in response to numerous requests by directors of statistics in the region for the development of capacity in that area. It was specifically timed to meet the training needs of those offices ahead of the 2010 round of Population and Housing Censuses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A presente dissertação trata sobre o Sistema de Gestão implantado no Centro de Tecnologia da Eletrobras - Eletronorte – OCT, face à norma ABNT NBR ISO/IEC17025. Objetiva analisar o Sistema de Gestão da Qualidade em laboratório de ensaio. Expõe o crescimento do uso de sistemas de gestão, para dizer que em geral tem aumentado à necessidade de assegurar que laboratórios que fazem parte de organizações maiores ou que oferecem outros serviços possam operar de acordo com um sistema de gestão que esteja em conformidade com a norma ABNT NBR ISO 9001. Para conduzir e operar com sucesso uma organização é necessário dirigila e controlá-la de maneira transparente e sistemática. Verifica-se que seu sucesso pode resultar da implementação e manutenção de um sistema de gestão concebido para melhorar continuamente seu desempenho, levando em consideração, ao mesmo tempo, as necessidades de todas as partes interessadas. Os laboratórios acreditados garantem aspectos referentes à confiabilidade, a confidencialidade dos resultados propostos, além da rastreabilidade dos padrões utilizados nos ensaios e calibrações.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study is to perform a situational analysis of the Laboratory of pulp and paper-UNESP ITAPEVA for conducting proposal the accreditation according to ISO / IEC 17025:2005. The ISO / IEC 17025 establishes the criteria for those laboratories wishing to demonstrate their technical competence, which have an effective quality system and are able to generate technically valid results, establishing a single international standard for certifying the competence of laboratories to carry tests and / or calibrations, including sampling. The case study was conducted on laboratory Pulp and Paper Universidade Estadual Paulista (UNESP), campus Itapeva, where we compared the views of the technician responsible for the laboratory and a regular user. The generated conclusion is that the laboratory is unable to initiate an accreditation process, because it fails the requirements such as quality manual, register of subcontractors, research of customer satisfaction, schedule of internal audits, schedule for completion of critical analysis, profile of the functions required, functions current description, documentation of technical requirements for accommodation and environmental conditions, calibration programs, equipment calibration program, programs calibration standards and reports and / or certificate of test and / or calibration, that are in accordance with ISO / IEC 17025:2005, beyond that there is not the possibility to develop and implement a quality system without the commitment of everyone involved, regardless of the functional hierarchy

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work aimed to assess the bacteriological quality of water used in the irrigation of vegetable gardens in the municipalities of Araraquara, Boa Esperança do Sul and Ibitinga, São Paulo, Brazil. A total of 80 samples of water used in the irrigation of 40 vegetable gardens were analyzed, two samples coming from each vegetable garden. They were collected at the same site in different months, which resulted in two sample collection groups. The most probable number (MPN/100mL) of total coliforms, thermotolerant coliforms and enterococci was identifi ed by means of the multiple tube technique. The analysis of the fi rst group samples showed quantities of thermotolerant coliforms above the amount allowed by current law for irrigation water (CONAMA Resolution n. 357) in nine cases. The owners of those vegetable gardens were then instructed in water disinfection procedures. After the analysis of the second group samples, it was noticed that only one sample did not meet the quality standards, and it was collected at a site where no disinfection procedure had been carried out. According to the results, 77.5% of the vegetable gardens were using water whose samples meet the quality standards. After the owners were instructed with regard to disinfection procedures, that number changed to 97.5%, which confi rms the importance of controlling and supervising irrigation water quality

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Today, many leading organizations are undertaking extensive research on a very broad range of new and evolving optical networking technologies. These efforts carry particular significance, especially in light of the “postbubble” dynamics of the optical networking market and have led to the investigation of various cost-efficient optical technologies. Today’s telecom carriers operate several independent optical domains based on diverse technologies, control solutions, standards, and protocols, making interdomain and intercarrier interworking extremely difficult. Standardized interworking across diverse multigranularity network interfaces, and interoperability across disparate vendor equipments and carrier domains are crucial to provisioning end-to-end services and achieving cost-efficient network operation. Needless to say, having an interoperable and standard control plane across multidomain optical networks can benefit carriers through the availability of a wide selection of network elements, platforms, and multiple vendor solutions resulting in faster deployment and reduced CAPEX and OPEX charges.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The hybrid created from the crossbreeding of European and African bees, known as the Africanised bee, has provided numerous advantages for current beekeeping. However, this new species exhibits undesirable behaviours, such as colony defence instinct and a propensity to attack en masse, which can result in serious accidents. To date, there is no effective treatment for cases of Africanised bee envenomation. One promising technique for developing an efficient antivenom is the use of phage display technology, which enables the production of human antibodies, thus avoiding the complications of serum therapy, such as anaphylaxis and serum sickness. The aim of this study was to produce human monoclonal single-chain Fv (scFv) antibody fragments capable of inhibiting the toxic effects of Africanised bee venom. We conducted four rounds of selection of antibodies against the venom and three rounds of selection of antibodies against purified melittin. Three clones were selected and tested by enzyme-linked immunosorbent assay to verify their specificity for melittin and phospholipase A2. Two clones (C5 and C12) were specific for melittin, and one (A7) was specific for phospholipase A2. In a kinetic haemolytic assay, these clones were evaluated individually and in pairs. The A7-C12 combination had the best synergistic effect and was chosen to be used in the assays of myotoxicity inhibition and lethality. The A7-C12 combination inhibited the in vivo myotoxic effect of the venom and increased the survival of treated animals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The in vitro stability of cocaine in horse blood, sheep vitreous humour (VH) and homogenised deer muscle is described. The stability of cocaine in horse blood was of interest because many toxicology laboratories utilise horse blood for the preparation of calibration and check standards and the latter are typically stored during routine use. The storage stability of cocaine in human VH and muscle has not been previously reported. In the absence of blank human VH and muscle, cocaine stability under varying conditions was demonstrated in animal tissues. Blood and VH were stored with and without addition of NaF at room temperature (RT), 4 degrees C and -18 degrees C for 84 days. Muscle homogenates were prepared in water, water/2% NaF, and phosphate buffer (pH 6.0)/2% NaF, and stored for 31 days at RT, 4 degrees C and -18 degrees C. Cocaine stability in human muscle obtained from cocaine positive forensic cases was assessed following storage at -18 degrees C for 13 months. Cocaine and benzoylecgonine (BZE) were extracted using SPE and quantified by GC-MS/MS. Cocaine was stable for 7 days in refrigerated (4 degrees C) horse blood fortified with 1 and 2% NaF. In the absence of NaF, cocaine was not detectable by day 7 in blood stored at RT and 4 degrees C and had declined by 81% following storage at -18 degrees C. At 4 degrees C the rate of cocaine degradation in blood preserved with 2% NaF was significantly slower than with 1% NaF. The stability of cocaine in horse blood appeared to be less than that reported for human blood, probably attributable to the presence of carboxylesterase in horse plasma. Cocaine stored in VH at -18 degrees C was essentially stable for the study period whereas at 4 degrees C concentrations decreased by >50% in preserved and unpreserved VH stored for longer than 14 days. Fluoride did not significantly affect cocaine stability in VH. The stability of cocaine in muscle tissue homogenates significantly exceeded that in blood and VH at every temperature. In preserved and unpreserved samples stored at 4 degrees C and below, cocaine loss did not exceed 2%. The increased stability of cocaine in muscle was attributed to the low initial pH of post-mortem muscle. In tissue from one human case stored for 13 months at -18 degrees C the muscle cocaine concentration declined by only 15% (range: 5-22%). These findings promote the use of human muscle as a toxicological specimen in which cocaine may be detected for longer compared with blood or VH. (C) 2011 Elsevier Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Analytic methods were applied and validated to measure residues of chlorfenvinphos, fipronil, and cypermethrin in meat and bovine fat, using the QuEChERS method and gas chromatography-mass spectrometry. For the meat, 2 g of sample, 4mL of acetonitrile, 1.6 g of MgSO4, and 0.4 g of NaCl were used in the liquid-liquid partition, while 80 mg of C18, 80 mg of primary and secondary amine and 150 mg of MgSO4 were employed in the dispersive solid-phase extraction. For the fat, 1 g of sample, 5 mL of hexane, 10 mL of water, 10 mL of acetonitrile, 4 g of MgSO4, and 0.5 g of NaCl were used in the liquid-liquid partition and 50 mg of primary and secondary amine and 150 mg of MgSO4 were used in the dispersive solid-phase extraction. The recovery percentages obtained for the pesticides in meat at different concentrations ranged from 81 to 129% with relative standard deviation below 27%. The corresponding results from the fat ranged from 70 to 123% with relative standard deviation below 25%. The methods showed sensitivity, precision, and accuracy according to EPA standards and quantification limits below the maximum residue limit established by European Union, except for chlorfenvinphos in the fat.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Euterpe edulis is an endangered species due to palm heart overharvesting, the most important non-timber forest product of the Brazilian Atlantic Forest, and fruit exploitation has been introduced as a low impacting alternative. However, E. edulis is a keystone species for frugivores birds, and even the impact of fruit exploitation needs to be better investigated. Since this species occurs over contrasting habitats, the establishment of site-specific standards and limits for exploitation may also be essential to achieve truly sustainable management. In this context, we sought to investigate how soil chemical composition would potentially affect E. edulis (Arecaceae) palm heart and fruit exploitation considering current standards of management. We studied natural populations found in Restinga Forest and Atlantic Rainforest remnants established within Natural Reserves of Sao Paulo State, SE Brazil, where 10.24 ha permanent plots, composed of a grid of 256 subplots (20 m x 20 m), were located. In each of these subplots, we evaluated soil chemical composition and diameter at breast height of E. edulis individuals. Additionally, we evaluated fruit yield in 2008 and 2009 in 20 individuals per year. The Atlantic Rainforest population had a much higher proportion of larger diameter individuals than the population from the Restinga Forest, as a result of habitat-mediated effects, especially those related to soil. Sodium and potassium concentration in Restinga Forest soils, which have strong negative and positive effect on palm growth, respectively, played a key role in determining those differences. Overall, the number of fruits that could be exploited in the Atlantic Rainforest was four times higher than in Restinga Forest. If current rules for palm heart and fruit harvesting were followed without any restriction to different habitats, Restinga Forest populations are under severe threat, as this study shows that they are not suitable for sustainable management of both fruits and palm heart. Hence, a habitat-specific approach of sustainable management is needed for this species in order to respect the demographic and ecological dynamics of each population to be managed. These findings suggest that any effort to create general management standards of low impacting harvesting may be unsuccessful if the species of interest occur over a wide range of ecosystems. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electronic business surely represents the new development perspective for world-wide trade. Together with the idea of ebusiness, and the exigency to exchange business messages between trading partners, the concept of business-to-business (B2B) integration arouse. B2B integration is becoming necessary to allow partners to communicate and exchange business documents, like catalogues, purchase orders, reports and invoices, overcoming architectural, applicative, and semantic differences, according to the business processes implemented by each enterprise. Business relationships can be very heterogeneous, and consequently there are variousways to integrate enterprises with each other. Moreover nowadays not only large enterprises, but also the small- and medium- enterprises are moving towards ebusiness: more than two-thirds of Small and Medium Enterprises (SMEs) use the Internet as a business tool. One of the business areas which is actively facing the interoperability problem is that related with the supply chain management. In order to really allow the SMEs to improve their business and to fully exploit ICT technologies in their business transactions, there are three main players that must be considered and joined: the new emerging ICT technologies, the scenario and the requirements of the enterprises and the world of standards and standardisation bodies. This thesis presents the definition and the development of an interoperability framework (and the bounded standardisation intiatives) to provide the Textile/Clothing sectorwith a shared set of business documents and protocols for electronic transactions. Considering also some limitations, the thesis proposes a ontology-based approach to improve the functionalities of the developed framework and, exploiting the technologies of the semantic web, to improve the standardisation life-cycle, intended as the development, dissemination and adoption of B2B protocols for specific business domain. The use of ontologies allows the semantic modellisation of knowledge domains, upon which it is possible to develop a set of components for a better management of B2B protocols, and to ease their comprehension and adoption for the target users.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The research activity carried out during the PhD course in Electrical Engineering belongs to the branch of electric and electronic measurements. The main subject of the present thesis is a distributed measurement system to be installed in Medium Voltage power networks, as well as the method developed to analyze data acquired by the measurement system itself and to monitor power quality. In chapter 2 the increasing interest towards power quality in electrical systems is illustrated, by reporting the international research activity inherent to the problem and the relevant standards and guidelines emitted. The aspect of the quality of voltage provided by utilities and influenced by customers in the various points of a network came out only in recent years, in particular as a consequence of the energy market liberalization. Usually, the concept of quality of the delivered energy has been associated mostly to its continuity. Hence the reliability was the main characteristic to be ensured for power systems. Nowadays, the number and duration of interruptions are the “quality indicators” commonly perceived by most customers; for this reason, a short section is dedicated also to network reliability and its regulation. In this contest it should be noted that although the measurement system developed during the research activity belongs to the field of power quality evaluation systems, the information registered in real time by its remote stations can be used to improve the system reliability too. Given the vast scenario of power quality degrading phenomena that usually can occur in distribution networks, the study has been focused on electromagnetic transients affecting line voltages. The outcome of such a study has been the design and realization of a distributed measurement system which continuously monitor the phase signals in different points of a network, detect the occurrence of transients superposed to the fundamental steady state component and register the time of occurrence of such events. The data set is finally used to locate the source of the transient disturbance propagating along the network lines. Most of the oscillatory transients affecting line voltages are due to faults occurring in any point of the distribution system and have to be seen before protection equipment intervention. An important conclusion is that the method can improve the monitored network reliability, since the knowledge of the location of a fault allows the energy manager to reduce as much as possible both the area of the network to be disconnected for protection purposes and the time spent by technical staff to recover the abnormal condition and/or the damage. The part of the thesis presenting the results of such a study and activity is structured as follows: chapter 3 deals with the propagation of electromagnetic transients in power systems by defining characteristics and causes of the phenomena and briefly reporting the theory and approaches used to study transients propagation. Then the state of the art concerning methods to detect and locate faults in distribution networks is presented. Finally the attention is paid on the particular technique adopted for the same purpose during the thesis, and the methods developed on the basis of such approach. Chapter 4 reports the configuration of the distribution networks on which the fault location method has been applied by means of simulations as well as the results obtained case by case. In this way the performance featured by the location procedure firstly in ideal then in realistic operating conditions are tested. In chapter 5 the measurement system designed to implement the transients detection and fault location method is presented. The hardware belonging to the measurement chain of every acquisition channel in remote stations is described. Then, the global measurement system is characterized by considering the non ideal aspects of each device that can concur to the final combined uncertainty on the estimated position of the fault in the network under test. Finally, such parameter is computed according to the Guide to the Expression of Uncertainty in Measurements, by means of a numeric procedure. In the last chapter a device is described that has been designed and realized during the PhD activity aiming at substituting the commercial capacitive voltage divider belonging to the conditioning block of the measurement chain. Such a study has been carried out aiming at providing an alternative to the used transducer that could feature equivalent performance and lower cost. In this way, the economical impact of the investment associated to the whole measurement system would be significantly reduced, making the method application much more feasible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Das Time-of-Flight Aerosol Mass Spectrometer (ToF-AMS) der Firma Aerodyne ist eine Weiterentwicklung des Aerodyne Aerosolmassenspektrometers (Q-AMS). Dieses ist gut charakterisiert und kommt weltweit zum Einsatz. Beide Instrumente nutzen eine aerodynamische Linse, aerodynamische Partikelgrößenbestimmung, thermische Verdampfung und Elektronenstoß-Ionisation. Im Gegensatz zum Q-AMS, wo ein Quadrupolmassenspektrometer zur Analyse der Ionen verwendet wird, kommt beim ToF-AMS ein Flugzeit-Massenspektrometer zum Einsatz. In der vorliegenden Arbeit wird anhand von Laborexperimenten und Feldmesskampagnen gezeigt, dass das ToF-AMS zur quantitativen Messung der chemischen Zusammensetzung von Aerosolpartikeln mit hoher Zeit- und Größenauflösung geeignet ist. Zusätzlich wird ein vollständiges Schema zur ToF-AMS Datenanalyse vorgestellt, dass entwickelt wurde, um quantitative und sinnvolle Ergebnisse aus den aufgenommenen Rohdaten, sowohl von Messkampagnen als auch von Laborexperimenten, zu erhalten. Dieses Schema basiert auf den Charakterisierungsexperimenten, die im Rahmen dieser Arbeit durchgeführt wurden. Es beinhaltet Korrekturen, die angebracht werden müssen, und Kalibrationen, die durchgeführt werden müssen, um zuverlässige Ergebnisse aus den Rohdaten zu extrahieren. Beträchtliche Arbeit wurde außerdem in die Entwicklung eines zuverlässigen und benutzerfreundlichen Datenanalyseprogramms investiert. Dieses Programm kann zur automatischen und systematischen ToF-AMS Datenanalyse und –korrektur genutzt werden.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Concerns of Thai consumers on food safety have been recently increasing, especially in urban areas and for fresh produce because food safety scandals, such as chemical residues on fresh produce (e.g., cabbage) still frequently occur. The Thai government tried to meet consumer needs by imposing in the domestic market a stronger regulation aimed at increasing the baseline level of food safety assurance and by introducing a voluntary standard (based on Good Agricultural Practices or GAPs and known as Q-GAP) and the related food safety label (i.e., Q mark). However, since standards and regulations are weakly implemented in the domestic market compared to exported products, there is still a lack of Thai consumers’ confidence in the safety of local food products. In this work the current situation of GAPs adoption in Thai fresh produce production is analysed. Furthermore, it is studied whether Thai consumers place value on food safety labels available on the market, to know whether consumer demand could drive the market of certified safer products. This study contains three essays: 1) a review of the literature, 2) a qualitative study on stakeholders' perception toward GAPs adoption and 3) a quantitative study, aimed at analysing consumers' preferences and willingness-to-pay for food safety labels on fresh produce using a discrete choice experiment. This dissertation contributes to the economics of quality assurance and labelling, specifically addressing GAPs and food safety label in the fresh produce supply chain. Results show that Q-GAP could be effectively used to improve food safety in Thai domestic market, but its credibility should be improved. Stakeholder’s awareness toward food safety issues and the delivery of reliable and sound information are crucial. Thai consumers are willing to pay a premium price for food safety labelled produce over unlabelled ones. Implications for both government and business decision-makers are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chapter 1 studies how consumers’ switching costs affect the pricing and profits of firms competing in two-sided markets such as Apple and Google in the smartphone market. When two-sided markets are dynamic – rather than merely static – I show that switching costs lower the first-period price if network externalities are strong, which is in contrast to what has been found in one-sided markets. By contrast, switching costs soften price competition in the initial period if network externalities are weak and consumers are more patient than the platforms. Moreover, an increase in switching costs on one side decreases the first-period price on the other side. Chapter 2 examines firms’ incentives to invest in local and flexible resources when demand is uncertain and correlated. I find that market power of the monopolist providing flexible resources distorts investment incentives, while competition mitigates them. The extent of improvement depends critically on demand correlation and the cost of capacity: under social optimum and monopoly, if the flexible resource is cheap, the relationship between investment and correlation is positive, and if it is costly, the relationship becomes negative; under duopoly, the relationship is positive. The analysis also sheds light on some policy discussions in markets such as cloud computing. Chapter 3 develops a theory of sequential investments in cybersecurity. The regulator can use safety standards and liability rules to increase security. I show that the joint use of an optimal standard and a full liability rule leads to underinvestment ex ante and overinvestment ex post. Instead, switching to a partial liability rule can correct the inefficiencies. This suggests that to improve security, the regulator should encourage not only firms, but also consumers to invest in security.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Since the late 1990s and early 2000s, derivatives of well-known designer drugs as well as new psychoactive compounds have been sold on the illicit drug market and have led to intoxications and fatalities. The LC-MS/MS screening method presented covers 31 new designer drugs as well as cathinone, methcathinone, phencyclidine, and ketamine which were included to complete the screening spectrum. All but the last two are modified molecular structures of amphetamine, tryptamine, or piperazine. Among the amphetamine derivatives are cathinone, methcathinone, 3,4-DMA, 2,5-DMA, DOB, DOET, DOM, ethylamphetamine, MDDMA, 4-MTA, PMA, PMMA, 3,4,5-TMA, TMA-6 and members of the 2C group: 2C-B, 2C-D, 2C-H, 2C-I, 2C-P, 2C-T-2, 2C-T-4, and 2C-T-7. AMT, DPT, DiPT, MiPT, DMT, and 5MeO-DMT are contained in the tryptamine group, BZP, MDBP, TFMPP, mCPP, and MeOPP in the piperazine group. Using an Applied Biosystems LC-MS/MS API 365 TurboIonSpray it is possible to identify all 35 substances. After addition of internal standards and mixed-mode solid-phase extraction the analytes are separated using a Synergi Polar RP column and gradient elution with 1 mM ammonium formate and methanol/0.1% formic acid as mobile phases A and B. Data acquisition is performed in MRM mode with positive electro spray ionization. The assay is selective for all tested substances. Limits of detection were determined by analyzing S/N-ratios and are between 1.0 and 5.0 ng/mL. Matrix effects lie between 65% and 118%, extraction efficiencies range from 72% to 90%.