442 resultados para trimming coils


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Postmortem MRI (PMMR) examinations are seldom performed in legal medicine due to long examination times, unfamiliarity with the technique, and high costs. Furthermore, it is difficult to obtain access to an MRI device used for patients in clinical settings to image an entire human body. An alternative is available: ex situ organ examination. To our knowledge, there is no standardized protocol that includes ex situ organ preparation and scanning parameters for postmortem MRI. Thus, our objective was to develop a standard procedure for ex situ heart PMMR examinations. We also tested the oily contrast agent Angiofil® commonly used for PMCT angiography, for its applicability in MRI. We worked with a 3 Tesla MRI device and 32-channel head coils. Twelve porcine hearts were used to test different materials to find the best way to prepare and place organs in the device and to test scanning parameters. For coronary MR angiography, we tested different mixtures of Angiofil® and different injection materials. In a second step, 17 human hearts were examined to test the procedure and its applicability to human organs. We established two standardized protocols: one for preparation of the heart and another for scanning parameters based on experience in clinical practice. The established protocols enabled a standardized technical procedure with comparable radiological images, allowing for easy radiological reading. The performance of coronary MR angiography enabled detailed coronary assessment and revealed the utility of Angiofil® as a contrast agent for PMMR. Our simple, reproducible method for performing heart examinations ex situ yields high quality images and visualization of the coronary arteries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Propensity score (PS) techniques are useful if the number of potential confounding pretreatment variables is large and the number of analysed outcome events is rather small so that conventional multivariable adjustment is hardly feasible. Only pretreatment characteristics should be chosen to derive PS, and only when they are probably associated with outcome. A careful visual inspection of PS will help to identify areas of no or minimal overlap, which suggests residual confounding, and trimming of the data according to the distribution of PS will help to minimise residual confounding. Standardised differences in pretreatment characteristics provide a useful check of the success of the PS technique employed. As with conventional multivariable adjustment, PS techniques cannot account for confounding variables that are not or are only imperfectly measured, and no PS technique is a substitute for an adequately designed randomised trial.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study assessed the attitudes of personnel involved in therapeutic claw trimming of dairy cattle in Switzerland towards pain associated with sole ulcers and their treatment. Data from 77 farmers, 32 claw trimmers, and 137 cattle veterinarians were used. A large range of factors were associated with whether the respondents thought that anaesthesia during the treatment of sole ulcers was beneficial; these included year of graduation, work experience, attitude to costs of analgesia, perception of competition between veterinarians and claw trimmers, estimation of pain level associated with treatment, estimated sensitivity of dairy cows to pain, knowledge of the obligation to provide analgesia, and whether the respondent thought lesion size and occurrence of defensive behaviour by the cow were important. Respondents' estimation of the pain level associated with sole ulcer treatment was linked to frequency of therapeutic claw trimming, age, farmers' income, estimated knowledge of the benefits of analgesia, and estimated sensitivity of dairy cows to pain. The latter factor was associated with profession, frequency of therapeutic claw trimming, capability of pain recognition, opinion on the benefits of analgesia, knowledge of the obligation to provide analgesia, and self-estimation of the ability to recognise pain. Improving the knowledge of personnel involved in therapeutic claw trimming with regard to pain in dairy cows and how to alleviate it is crucial if management of pain associated with treatment of sole ulcer and the welfare of lame cows are to be optimised.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract The current treatment of painful hip dysplasia in the mature skeleton is based on acetabular reorientation. Reorientation procedures attempt to optimize the anatomic position of the hyaline cartilage of the femoral head and acetabulum in regard to mechanical loading. Because the Bernese periacetabular osteotomy is a versatile technique for acetabular reorientation, it is helpful to understand the approach and be familiar with the criteria for an optimal surgical correction. The femoral side bears stigmata of hip dysplasia that may require surgical correction. Improvement of the head-neck offset to avoid femoroacetabular impingement has become routine in many hips treated with periacetabular osteotomy. In addition, intertrochanteric osteotomies can help improve joint congruency and normalize the femoral neck orientation. Other new surgical techniques allow trimming or reducing a severely deformed head, performing a relative neck lengthening, and trimming or distalizing the greater trochanter.  An increasing number of studies have reported good long-term results after acetabular reorientation procedures, with expected joint preservation rates ranging from 80% to 90% at the 10-year follow-up and 60% to 70% at the 20-year follow-up. An ideal candidate is younger than 30 years, with no preoperative signs of osteoarthritis. Predicted joint preservation in these patients is approximately 90% at the 20-year follow-up. Recent evidence indicates that additional correction of an aspheric head may further improve results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Patients with femoroacetabular impingement (FAI) often develop pain, impaired function, and progression of osteoarthritis (OA); this is commonly treated using surgical hip dislocation, femoral neck and acetabular rim osteoplasty, and labral reattachment. However, results with these approaches, in particular risk factors for OA progression and conversion to THA, have varied. QUESTIONS/PURPOSES We asked if patients undergoing surgical hip dislocation with labral reattachment to treat FAI experienced (1) improved hip pain and function; and (2) prevention of OA progression; we then determined (3) the survival of the hip at 5-year followup with the end points defined as the need for conversion to THA, progression of OA by at least one Tönnis grade, and/or a Merle d'Aubigné-Postel score less than 15; and calculated (4) factors predicting these end points. METHODS Between July 2001 and March 2003, we performed 146 of these procedures in 121 patients. After excluding 35 patients (37 hips) who had prior open surgery and 11 patients (12 hips) who had a diagnosis of Perthes disease, this study evaluated the 75 patients (97 hips, 66% of the procedures we performed during that time) who had a mean followup of 6 years (range, 5-7 years). We used the anterior impingement test to assess pain, the Merle d'Aubigné-Postel score to assess function, and the Tönnis grade to assess OA. Survival and predictive factors were calculated using the method of Kaplan and Meier and Cox regression, respectively. RESULTS The proportion of patients with anterior impingement decreased from 95% to 17% (p < 0.001); the Merle d'Aubigné-Postel score improved from a mean of 15 to 17 (p < 0.001). Seven hips (7%) showed progression of OA and another seven hips (7%) converted to THA Survival free from any end point (THA, progression of OA, or a Merle d'Aubigné-Postel < 15) of well-functioning joints at 5 years was 91%; and excessive acetabular rim trimming, preoperative OA, increased age at operation, and weight were predictive factors for the end points. CONCLUSIONS At 5-year followup, 91% of patients with FAI treated with surgical hip dislocation, osteoplasty, and labral reattachment showed no THA, progression of OA, or an insufficient clinical result, but excessive acetabular trimming, OA, increased age, and weight were associated with early failure. To prevent early deterioration of the joint, excessive rim trimming or trimming of borderline dysplastic hips has to be avoided.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE Acetabular rim trimming is indicated in pincer hips with an oversized lunate surface but could result in a critically decreased size of the lunate surface in pincer hips with acetabular malorientation. There is a lack of detailed three-dimensional anatomy of lunate surface in pincer hips. Therefore, we questioned how does (1) size and (2) shape of the lunate surface differ among hips with different types of pincer impingement? METHOD We retrospectively compared size and shape of the lunate surface between acetabular retroversion (48 hips), deep acetabulum (34 hips), protrusio acetabuli (seven hips), normal acetabuli (30 hips), and hip dysplasia (45 hips). Using magnetic resonance imaging (MRI) arthrography with radial slices we measured size in percentage of the femoral head coverage and shape using the outer (inner) center-edge angles and width of lunate surface. RESULTS Hips with retroversion had a decreased size and deep hips had normal size of the lunate surface. Both had a normal shape of the outer acetabular rim. Protrusio hips had an increased size and a prominent outer acetabular rim. In all three types of pincer hips the acetabular fossa was increased. CONCLUSION Size and shape of the lunate surface differs substantially among different types of pincer impingement. In contrast to hips with protrusio acetabuli, retroverted and deep hips do not have an increased size of the lunate surface. Acetabular rim trimming in retroverted and deep hips should be performed with caution. Based on our results, acetabular reorientation would theoretically be the treatment of choice in retroverted hips.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Acetabular anatomy on AP pelvic radiographsdepends on pelvic orientation during radiograph acquisition. However, not all parameters may change to a clinically relevant degree with differences in pelvic orientation. This issue may influence the diagnosis of acetabular pathologies and planning of corrective acetabular surgery (reorientation or rim trimming). However, to this point, it has not been well characterized. Questions/purposes We asked (1) which radiographic parameters change in a clinical setting when normalized to neutral pelvic orientation; (2) which parameters do not change in an experimental setting when the pelvis is experimentally rotated/tilted; and (3) which of these changes are ‘‘ultimately’’ relevant based on a prespecified definition of relevance. Methods In a clinical setup, 11 hip parameters were evaluated in 101 patients (126 hips) by two observers and the interobserver difference was calculated. All parameters were normalized to an anatomically defined neutral pelvic orientation with the help of a lateral pelvic radiograph and specific software. Differences between nonnormalized and normalized values were calculated (effect of normalization). In an experimental setup involving 20 cadaver pelves (40 hips), the maximum range for each parameter was computed with the pelvis rotated (range, −12° to 12°) and tilted (range, −24° to 24°). ‘‘Ultimately’’ relevant changes existed if the effect of normalization exceeded the interobserver difference (eg, 37% versus 6% for prevalence of a positive crossover sign) and/or the maximum experimental range exceeded 1 SD of interobserver difference (eg, 27% versus 6% for anterior acetabular coverage). Results In the clinical setup, all parameters except the ACM angle and craniocaudal acetabular coverage changed when being normalized, eg, effect of normalization for lateral center-edge angle, acetabular index, and sharp angle ranged from −5° to 4° (p values < 0.029). In the experimental setup, five parameters showed no major changes, whereas six parameters did change (all p values < 0.001). Ultimately relevant changes were found for anteroposterior acetabular coverage, retroversion index, and prevalence of a positive crossover or posterior wall sign. Conclusions Lateral center-edge angle, ACM angle, Sharp angle, acetabular and extrusion index, and craniocaudal acetabular coverage showed no relevant changes with varying pelvic orientation and can therefore be acquired independent from individual pelvic tilt and rotation in clinical practice. In contrast, anteroposterior acetabular coverage, crossover and posterior wall sign, and retroversion index call for specific efforts that address individual pelvic orientation such as computer-assisted evaluation of radiographs. Level of Evidence Level III, diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Both acetabular undercoverage (hip dysplasia) and overcoverage (pincer-type femoroacetabular impingement) can result in hip osteoarthritis. In contrast to undercoverage, there is a lack of information on radiographic reference values for excessive acetabular coverage. Questions/purposes (1) How do common radiographic hip parameters differ in hips with a deficient or an excessive acetabulum in relation to a control group; and (2) what are the reference values determined from these data for acetabular under- and overcoverage? Methods We retrospectively compared 11 radiographic parameters describing the radiographic acetabular anatomy among hip dysplasia (26 hips undergoing periacetabular osteotomy), control hips (21 hips, requiring no rim trimming during surgical hip dislocation), hips with overcoverage (14 hips, requiring rim trimming during surgical hip dislocation), and hips with severe overcoverage (25 hips, defined as having acetabular protrusio). The hips were selected from a patient cohort of a total of 593 hips. Radiographic parameters were assessed with computerized methods on anteroposterior pelvic radiographs and corrected for neutral pelvic orientation with the help of a true lateral radiograph. Results All parameters except the crossover sign differed among the four study groups. From dysplasia through control and overcoverage, the lateral center-edge angle, acetabular arc, and anteroposterior/craniocaudal coverage increased. In contrast, the medial center-edge angle, extrusion/acetabular index, Sharp angle, and prevalence of the posterior wall sign decreased. The following reference values were found: lateral center-edge angle 23° to 33°, medial center-edge angle 35° to 44°, acetabular arc 61° to 65°, extrusion index 17% to 27%, acetabular index 3° to 13°, Sharp angle 38° to 42°, negative crossover sign, positive posterior wall sign, anterior femoral head coverage 15% to 26%, posterior femoral head coverage 36% to 47%, and craniocaudal coverage 70% to 83%. Conclusions These acetabular reference values define excessive and deficient coverage. They may be used for radiographic evaluation of symptomatic hips, may offer possible predictors for surgical outcomes, and serve to guide clinical decision-making.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new haptic interface device is suggested, which can be used for functional magnetic resonance imaging (fMRI) studies. The basic component of this 1 DOF haptic device are two coils that produce a Lorentz force induced by the large static magnetic field of the MR scanner. A MR-compatible optical angular encoder and a optical force sensor enable the implementation of different control architectures for haptic interactions. The challenge was to provide a large torque, and not to affect image quality by the currents applied in the device. The haptic device was tested in a 3T MR scanner. With a current of up to 1A and a distance of 1m to the focal point of the MR-scanner it was possible to generate torques of up to 4 Nm. Within these boundaries image quality was not affected.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND We previously reported the 5-year followup of hips with femoroacetabular impingement (FAI) that underwent surgical hip dislocation with trimming of the head-neck junction and/or acetabulum including reattachment of the labrum. The goal of this study was to report a concise followup of these patients at a minimum 10 years. QUESTIONS/PURPOSES We asked if these patients had (1) improved hip pain and function; we then determined (2) the 10-year survival rate and (3) calculated factors predicting failure. METHODS Between July 2001 and March 2003, we performed surgical hip dislocation and femoral neck osteoplasty and/or acetabular rim trimming with labral reattachment in 75 patients (97 hips). Of those, 72 patients (93 hips [96%]) were available for followup at a minimum of 10 years (mean, 11 years; range, 10-13 years). We used the anterior impingement test to assess pain and the Merle d'Aubigné-Postel score to assess function. Survivorship calculation was performed using the method of Kaplan and Meier and any of the following factors as a definition of failure: conversion to total hip arthroplasty (THA), radiographic evidence of worsening osteoarthritis (OA), or a Merle d'Aubigné-Postel score less than 15. Predictive factors for any of these failures were calculated using the Cox regression analysis. RESULTS At 10-year followup, the prevalence of a positive impingement test decreased from preoperative 95% to 38% (p < 0.001) and the Merle d'Aubigné-Postel score increased from preoperative 15.3 ± 1.4 (range, 9-17) to 16.9 ± 1.3 (12-18; p < 0.001). Survivorship of these procedures for any of the defined failures was 80% (95% confidence interval, 72%-88%). The strongest predictors of failure were age > 40 years (hazard ratio with 95% confidence interval, 5.9 [4.8-7.1], p = 0.002), body mass index > 30 kg/m(2) (5.5 [3.9-7.2], p = 0.041), a lateral center-edge angle < 22° or > 32° (5.4 [4.2-6.6], p = 0.006), and a posterior acetabular coverage < 34% (4.8 [3.7-5.6], p = 0.006). CONCLUSIONS At 10-year followup, 80% of patients with FAI treated with surgical hip dislocation, osteoplasty, and labral reattachment had not progressed to THA, developed worsening OA, or had a Merle d'Aubigné-Postel score of less than 15. Radiographic predictors for failure were related to over- and undertreatment of acetabular rim trimming.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Severe pincer impingement (acetabular protrusio) is an established cause of hip pain and osteoarthritis. The proposed underlying pathomechanism is a dynamic pathological contact of the prominent acetabular rim with the femoral head-neck junction. However, this cannot explain the classically described medial osteoarthritis in these hips. We therefore asked: (1) Does an overload exist in the medial aspect of the protrusio joint? and (2) What is the influence of three contemporary joint-preserving procedures on load distribution in protrusio hips? In vivo force and motion data for walking and standing to sitting were applied to six 3D finite element models (normal, dysplasia, protrusio, acetabular rim trimming, acetabular reorientation, and combined reorientation/rim trimming). Compared with dysplasia, the protrusio joint resulted in opposite patterns of von Mises stress and contact pressure during walking. In protrusio hips, we found an overload at the medial margin of the lunate surface (54% higher than normal). Isolated rim trimming further increased the medial overload (up to 28% higher than protrusio), whereas acetabular reorientation with/without rim trimming reduced stresses by up to 25%. Our results can be used as an adjunct for surgical decision making in the treatment of acetabular protrusio.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION Monitoring breathing pattern is especially relevant in infants with lung disease. Recently, a vest-based inductive plethysmograph system (FloRight®) has been developed for tidal breathing measurement in infants. We investigated the accuracy of tidal breathing flow volume loop (TBFVL) measurements in healthy term-born infants and infants with lung disease by the vest-based system in comparison to an ultrasonic flowmeter (USFM) with a face mask. We also investigated whether the system discriminates between healthy infants and those with lung disease. METHODS Floright® measures changes in thoracoabdominal volume during tidal breathing through magnetic field changes generated by current-carrying conductor coils in an elastic vest. Simultaneous TBFVL measurements by the vest-based system and the USFM were performed at 44 weeks corrected postmenstrual age during quiet unsedated sleep. TBFVL parameters derived by both techniques and within both groups were compared. RESULTS We included 19 healthy infants and 18 infants with lung disease. Tidal volume per body weight derived by the vest-based system was significantly lower with a mean difference (95% CI) of -1.33 ml/kg (-1.73; -0.92), P < 0.001. Respiratory rate and ratio of time to peak tidal expiratory flow over total expiratory time (tPTEF/tE) did not differ between the two techniques. Both systems were able to discriminate between healthy infants and those with lung disease using tPTEF/tE. CONCLUSION FloRight® accurately measures time indices and may discriminate between healthy infants and those with lung disease, but demonstrates differences in tidal volume measurements. It may be better suited to monitor breathing pattern than for TBFVL measurements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It has recently been reported in this journal that local fat depots produce a sizable frequency-dependent signal attenuation in magnetic resonance spectroscopy (MRS) of the brain. If of a general nature, this effect would question the use of internal reference signals for quantification of MRS and the quantitative use of MRS as a whole. Here, it was attempted to verify this effect and pinpoint the potential causes by acquiring data with various acquisition settings, including two field strengths, two MR scanners from different vendors, different water suppression sequences, RF coils, localization sequences, echo times, and lipid/metabolite phantoms. With all settings tested, the reported effect could not be reproduced, and it is concluded that water referencing and quantitative MRS per se remain valid tools under common acquisition conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE To reliably determine the amplitude of the transmit radiofrequency ( B1+) field in moving organs like the liver and heart, where most current techniques are usually not feasible. METHODS B1+ field measurement based on the Bloch-Siegert shift induced by a pair of Fermi pulses in a double-triggered modified Point RESolved Spectroscopy (PRESS) sequence with motion-compensated crusher gradients has been developed. Performance of the sequence was tested in moving phantoms and in muscle, liver, and heart of six healthy volunteers each, using different arrangements of transmit/receive coils. RESULTS B1+ determination in a moving phantom was almost independent of type and amplitude of the motion and agreed well with theory. In vivo, repeated measurements led to very small coefficients of variance (CV) if the amplitude of the Fermi pulse was chosen above an appropriate level (CV in muscle 0.6%, liver 1.6%, heart 2.3% with moderate amplitude of the Fermi pulses and 1.2% with stronger Fermi pulses). CONCLUSION The proposed sequence shows a very robust determination of B1+ in a single voxel even under challenging conditions (transmission with a surface coil or measurements in the heart without breath-hold). Magn Reson Med, 2015. © 2015 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Magnetic resonance imaging (MRI) is a non-invasive technique that offers excellent soft tissue contrast for characterizing soft tissue pathologies. Diffusion tensor imaging (DTI) is an MRI technique that has shown to have the sensitivity to detect subtle pathology that is not evident on conventional MRI. ^ Rats are commonly used as animal models in characterizing the spinal cord pathologies including spinal cord injury (SCI), cancer, multiple sclerosis, etc. These pathologies could affect both thoracic and cervical regions and complete characterization of these pathologies using MRI requires DTI characterization in both the thoracic and cervical regions. Prior to the application of DTI for investigating the pathologic changes in the spinal cord, it is essential to establish DTI metrics in normal animals. ^ To date, in-vivo DTI studies of rat spinal cord have used implantable coils for high signal-to-noise ratio (SNR) and spin-echo pulse sequences for reduced geometric distortions. Implantable coils have several disadvantages including: (1) the invasive nature of implantation, (2) loss of SNR due to frequency shift with time in the longitudinal studies, and (3) difficulty in imaging the cervical region. While echo planar imaging (EPI) offers much shorter acquisition times compared to spin-echo imaging, EPI is very sensitive to static magnetic field inhomogeneities and the existing shimming techniques implemented on the MRI scanner do not perform well on spinal cord because of its geometry. ^ In this work, an integrated approach has been implemented for in-vivo DTI characterization of rat spinal cord in the thoracic and cervical regions. A three element phased array coil was developed for improved SNR and extended spatial coverage. A field-map shimming technique was developed for minimizing the geometric distortions in EPI images. Using these techniques, EPI based DWI images were acquired with optimized diffusion encoding scheme from 6 normal rats and the DTI-derived metrics were quantified. ^ The phantom studies indicated higher SNR and smaller bias in the estimated DTI metrics than the previous studies in the cervical region. In-vivo results indicated no statistical difference in the DTI characteristics of either gray matter or white matter between the thoracic and cervical regions. ^