932 resultados para thermal comfort index


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This dissertation of master degree was presented to Post-Graduation Program in Architecture and Planning at UFRN, Brazil. It evaluates 45 one-family housings in the Metropolitan Area of Recife, whose architects consider them to be in conformity with the recommendations contained in Armando de Holanda's book: A Guide to build in the Brazilian Northeast: Architecture as a pleasant place in the sunny tropics , published in 1976 by UFPE. For a long time, it used to be reference in many Architecture and Planning Schools of the Northern Region of Brazil. The research s methodological procedures are based on the Post- Occupancy Evaluation (P.O.E.) with emphasis on the users' thermal comfort of the houses that make part of the sample. Therefore, it has been done technical analyses of the projects, when possible; interviews with the architects; building s inspections; and form applications to the users. The collected data analysis was based on the project recommendations of Holanda s book, they can be synthesized in the principle of Building Leafy". It can not be affirmed that all the houses present the recommendations contained in the guide, but, in many different ways, they exist, sometimes more intensely and sometimes more shyly. However, it can be noticed that in the 45 projects, that the architects perceived the importance of "Building Leafy" on the climatic reality of the Metropolitan Region of Recife

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present work concerns the use of shade elements as architectural elements to block sunlight in public buildings. In a city like Natal, (5o South) the incidence of sunrays in any type of design should be a constant concern for all the architects. Besides, this habit of avoiding insolation in the environment is not a common practice. Within this context, the present work has the objective to dig deep into the knowledge of solar control, studying some cases and verifying its function according to the orientation and the original design of the building, having in mind if the shade elements usually used in the region have achieved their purpose of providing protection against the incidence of direct sun rays. This study considers the position of the shade element (horizontal and vertical), the angle formed between them and the respective facades, and the local of the buildings in relation to their orientation during the summer, winter and equinox solstice. As supporting instruments the solar map of the city and the protractor, for measuring shade angles, were used. It was concluded that in all the cases studied, it was not possible to obtain the maximum use of the elements. It was verified that the best type of shade element (more efficient) for the city of Natal is the mixed type (horizontal and vertical) and that the vertical shade elements are more efficient in the early mornings and late afternoon. The horizontal shade elements are used more effective at midday. We intend to present the results of this study to the architects in the region in order to show them the correct ways of using the shade elements according to the possible orientation on the facade, as a supporting tool at the time of designing a project as well as a subsidy for further discussions on the elaboration of the new urban standards for the city of Natal/RN

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The presented work is related to the use of solar energy for the needs of heating and electricity for a single house located in Poland. Electricity will provided by energy conversion in the turbine by means of Organic Rankine Cycle (ORC), in which the operating medium (water heated in solar collector) is heating refrigerator in the heating exchanger. The solar installation is integrated with heat accumulator and wood boiler, which is used in the situation that collector is not enough to fill requirements of thermal comfort. There are chosen also all the necessary components of the system. In the work is also performed the economic assessment, by F chart method, to evaluate the profitability of the project, taking into total costs and savings.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A battery powered air-conditioning device was developed to provide an improved thermal comfort level for individuals in inadequately cooled environments. This device is a battery powered air-conditioning system with the phase change material (PCM) for heat storage. The condenser heat is stored in the PCM during the cooling operation and is discharged while the battery is charged by using the vapor compression cycle as a thermosiphon loop. The main focus of the current research was on the development of the cooling system. The cooling capacity of the vapor compression cycle measured was 165.6 W with system COP at 2.85. It was able to provide 2 hours cooling without discharging heat to the ambient. The PCM was recharged in nearly 8 hours under thermosiphon mode.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Traditional air delivery to high-bay buildings involves ceiling level supply and return ducts that create an almost-uniform temperature in the space. Problems with this system include potential recirculation of supply air and higher-than-necessary return air temperatures. A new air delivery strategy was investigated that involves changing the height of conventional supply and return ducts to have control over thermal stratification in the space. A full-scale experiment using ten vertical temperature profiles was conducted in a manufacturing facility over one year. The experimental data was utilized to validated CFD and EnergyPlus models. CFD simulation results show that supplying air directly to the occupied zone increases stratification while holding thermal comfort constant during the cooling operation. The building energy simulation identified how return air temperature offset, set point offset, and stratification influence the building’s energy consumption. A utility bill analysis for cooling shows 28.8% HVAC energy savings while the building energy simulation shows 19.3 – 37.4% HVAC energy savings.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Layer mortality due to heat stress is an important economic loss for the producer. The aim of this study was to determine the mortality pattern of layers reared in the region of Bastos, SP, Brazil, according to external environment and bird age. Data mining technique were used based on monthly mortality records of hens in production, 135 poultry houses, from January 2004 to August 2008. The external environment was characterized according maximum and minimum temperatures, obtained monthly at the meteorological station CATI in the city of Tupa, SP, Brazil. Mortality was classified as normal (<= 1.2%) or high (> 1.2%), considering the mortality limits mentioned in literature. Data mining technique produced a decision tree with nine levels and 23 leaves, with 62.6% of overall accuracy. The hit rate for the High class was 64.1% and 59.9% for Normal class. The decision tree allowed finding a pattern in the mortality data, generating a model for estimating mortality based on the thermal environment and bird age.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

(English)The Swedish industrial sector has overcome the oil crisis and has maintained the energy use constant even though the production has grown. This has been achieved thanks to the development of several energy policies, by the Swedish government, towards the 2020 goals. This thesis carries on this path and performs an energy audit for an old industrial building in Gävle (Sweden) in order to propose different energy efficiency measures to use less energy while maintaining the thermal comfort. The building is in quite a bad shape and some of the areas are unused making them a waste of money. By means of the invoices provided by different companies, the information from the staff and some measures that have been carried out in-situ, the energy balance has been calculated from where conclusions have been drawn. Although it is an industrial building, the study is not going to be focused in the industrial process but in the building’s envelope and support processes, since the unit combines both production and office areas. Therefore, the energy balance is divided in energy supplies (district heating, free heating and sun irradiation) and energy losses (transmission, ventilation hot tap water and infiltrations). The results show that the most important supply is that of the DH whereas the most important losses are the transmission and infiltration. Thus, the measures proposed are focused on the reduction of this relevant parameters. The most important measures are the renovation of the windows, heating systems valves and the ventilation. The glazing of the dwelling is old and some of it is broken accounting for quite a large amount of the losses. The radiator valves are not properly working and there does not exist any temperature control. Therefore the installation of thermostatic valves turns out to be a must. Moreover, some part of the building has no mechanical ventilation but conserves the ducts. These could be utilized if they are connected to the workshop’s ventilation which is capable of generating sufficient flow for the entire building. Finally, although other measures could also be carried out, the ones proposed appear to be the essential ones. A further analysis should be carried out in order to analyze the payback time or investment capability of the company so as to decide between one measure or another. A market study for possible new tenants for the unused parts of the building is also advisable.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present research concerns about outdoor s thermal comfort conditions in hot-humid climate cities, understanding that life quality is a result of the urban object s type built for the human being in an environment with specific climate and morphological characteristics. It is presented as object of study the correlation between the neighborhood Renascença II s microclimate in São Luis /MA-Brazil, hot-humid climate city, and its urban morphological changes. As well as the thermal comfort s satisfaction level of its outdoor users. The research has as general goal to diagnosis the way these transformations caused by the urbanization influence the Renascença II s microclimate, identifying critical spots of the studied area, in order to contribute with land use recommendations based on bioclimatic architecture concepts and supply bases to urban design decisions adequate to the São Luis climate. It is presented as theoretical bases the urban climate, its concepts and elements. After that, the thermal comfort conditioners and its prediction models of thermal comfort sensation in outdoor are presented. The predictive models are presented along with bioclimatic assessment methods. Finally the use of bioclimatic assessment as an effective tool to identify places that need changes or preservation in order to seek environment quality. The applied methodology was based on the studies of Katzschner (1997), complemented by Oliveira s (1988) and Bustos Romero s (2001) studies that suggest an analysis and evaluation of maps of topography, buildings floors, land use, green areas and land covering, in order to overlap their characteristics and identify climate variable s measurements points; then a quantitative analysis of the climate variables (air temperature and humidity, wind speed and direction) of the chosen points takes place. It was perceived that Renaissance II has no permanence areas as squares or parks, its outdoor has little vegetation and presets high land impermeability and built density levels. The majority of the people interviewed said that was comfortable in a range of air temperature between 27,28ºC and 30,71ºC. The elaboration of a neighborhood master plan is important, which defines strategies for improvement of the life quality of its inhabitants

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Natural ventilation is an efficient bioclimatic strategy, one that provides thermal comfort, healthful and cooling to the edification. However, the disregard for quality environment, the uncertainties involved in the phenomenon and the popularization of artificial climate systems are held as an excuse for those who neglect the benefits of passive cooling. The unfamiliarity with the concept may be lessened if ventilation is observed in every step of the project, especially in the initial phase in which decisions bear a great impact in the construction process. The tools available in order to quantify the impact of projected decisions consist basically of the renovation rate calculations or computer simulations of fluids, commonly dubbed CFD, which stands for Computational Fluid Dynamics , both somewhat apart from the project s execution and unable to adapt for use in parametric studies. Thus, we chose to verify, through computer simulation, the representativeness of the results with a method of simplified air reconditioning rate calculation, as well as making it more compatible with the questions relevant to the first phases of the project s process. The case object consists of a model resulting from the recommendations of the Código de Obras de Natal/ RN, customized according to the NBR 15220. The study has shown the complexity in aggregating a CFD tool to the process and the need for a method capable of generating data at the compatible rate to the flow of ideas and are discarded during the project s development. At the end of our study, we discuss the necessary concessions for the realization of simulations, the applicability and the limitations of both the tools used and the method adopted, as well as the representativeness of the results obtained

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This Masters Degree dissertation seeks to make a comparative study of internal air temperature data, simulated through the thermal computer application DesignBuilder 1.2, and data registered in loco through HOBO® Temp Data Logger, in a Social Housing Prototype (HIS), located at the Central Campus of the Federal University of Rio Grande do Norte UFRN. The prototype was designed and built seeking strategies of thermal comfort recommended for the local climate where the study was carried out, and built with panels of cellular concrete by Construtora DoisA, a collaborator of research project REPESC Rede de Pesquisa em Eficiência Energética de Sistemas Construtivos (Research Network on Energy Efficiency of Construction Systems), an integral part of Habitare program. The methodology employed carefully examined the problem, reviewed the bibliography, analyzing the major aspects related to computer simulations for thermal performance of buildings, such as climate characterization of the region under study and users thermal comfort demands. The DesignBuilder 1.2 computer application was used as a simulation tool, and theoretical alterations were carried out in the prototype, then they were compared with the parameters of thermal comfort adopted, based on the area s current technical literature. Analyses of the comparative studies were performed through graphical outputs for a better understanding of air temperature amplitudes and thermal comfort conditions. The data used for the characterization of external air temperature were obtained from the Test Reference Year (TRY), defined for the study area (Natal-RN). Thus the author also performed comparative studies for TRY data registered in the years 2006, 2007 and 2008, at weather station Davis Precision Station, located at the Instituto Nacional de Pesquisas Espaciais INPE-CRN (National Institute of Space Research), in a neighboring area of UFRN s Central Campus. The conclusions observed from the comparative studies performed among computer simulations, and the local records obtained from the studied prototype, point out that the simulations performed in naturally ventilated buildings is quite a complex task, due to the applications limitations, mainly owed to the complexity of air flow phenomena, the influence of comfort conditions in the surrounding areas and climate records. Lastly, regarding the use of the application DesignBuilder 1.2 in the present study, one may conclude that it is a good tool for computer simulations. However, it needs some adjustments to improve reliability in its use. There is a need for continued research, considering the dedication of users to the prototype, as well as the thermal charges of the equipment, in order to check sensitivity

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The assessment of building thermal performance is often carried out using HVAC energy consumption data, when available, or thermal comfort variables measurements, for free-running buildings. Both types of data can be determined by monitoring or computer simulation. The assessment based on thermal comfort variables is the most complex because it depends on the determination of the thermal comfort zone. For these reasons, this master thesis explores methods of building thermal performance assessment using variables of thermal comfort simulated by DesignBuilder software. The main objective is to contribute to the development of methods to support architectural decisions during the design process, and energy and sustainable rating systems. The research method consists on selecting thermal comfort methods, modeling them in electronic sheets with output charts developed to optimize the analyses, which are used to assess the simulation results of low cost house configurations. The house models consist in a base case, which are already built, and changes in thermal transmittance, absorptance, and shading. The simulation results are assessed using each thermal comfort method, to identify the sensitivity of them. The final results show the limitations of the methods, the importance of a method that considers thermal radiance and wind speed, and the contribution of the chart proposed

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The building envelope is the principal mean of interaction between indoors and environment, with direct influence on thermal and energy performance of the building. By intervening in the envelope, with the proposal of specific architectural elements, it is possible to promote the use of passive strategies of conditioning, such as natural ventilation. The cross ventilation is recommended by the NBR 15220-3 as the bioclimatic main strategy for the hot and humid climate of Natal/RN, offering among other benefits, the thermal comfort of occupants. The analysis tools of natural ventilation, on the other hand, cover a variety of techniques, from the simplified calculation methods to computer fluid dynamics, whose limitations are discussed in several papers, but without detailing the problems encountered. In this sense, the present study aims to evaluate the potential of wind catchers, envelope elements used to increase natural ventilation in the building, through CFD simplified simulation. Moreover, it seeks to quantify the limitations encountered during the analysis. For this, the procedure adopted to evaluate the elements implementation and efficiency was the CFD simulation, abbreviation for Computer Fluid Dynamics, with the software DesignBuilder CFD. It was defined a base case, where wind catchers were added with various settings, to compare them with each other and appreciate the differences in flows and air speeds encountered. Initially there has been done sensitivity tests for familiarization with the software and observe simulation patterns, mapping the settings used and simulation time for each case simulated. The results show the limitations encountered during the simulation process, as well as an overview of the efficiency and potential of wind catchers, with the increase of ventilation with the use of catchers, differences in air flow patterns and significant increase in air speeds indoors, besides changes found due to different element geometries. It is considered that the software used can help designers during preliminary analysis in the early stages of design

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This research covers the topic of social housing and its relation to thermal comfort, so applied to an architectural and urban intervention in land situated in central urban area of Macaíba/RN, Brazil. Reflecting on the role of design and use of alternative building materials in the search for better performance is one of its main goals. The hypothesis is that by changing design parameters and choice of materials, it is possible to achieve better thermal performance results. Thus, we performed computer simulations of thermal performance and natural ventilation using computational fluid dynamics or CFD (Computational Fluid Dynamics). The presentation of the thermal simulation followed the methodology proposed in the dissertation Negreiros (2010), which aims to find the percentage of the amount of hours of comfort obtained throughout the year, while data analysis was made of natural ventilation from images generated by the images extracted from the CFD. From model building designed, was fitted an analytical framework that results in a comparison between three different proposals for dwellings housing model, which is evaluated the question of the thermal performance of buildings, and also deals with the spatial variables design, construction materials and costs. It is concluded that the final report confirmed the general hypotheses set at the start of the study, it was possible to quantify the results and identify the importance of design and construction materials are equivalent, and that, if combined, lead to gains in thermal performance potential.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The employment of flexibility in the design of façades makes them adaptable to adverse weather conditions, resulting in both minimization of environmental discomfort and improvement of energy efficiency. The present study highlights the potential of flexible façades as a resource to reduce rigidity and form repetition, which are usually employed in condominiums of standardized houses; as such, the work presented herein contributes to field of study of architectural projects strategies for adapting and integrating buildings within the local climate context. Two façade options were designed using as reference the bionics and the kinetics, as well as their applications to architectural constructions. This resulted in two lightweight and dynamic structures, which cater to constraints of comfort through combinations of movements, which control the impact of solar radiation and of cooling in the environment. The efficacy and technical functionality of the façades were tested with comfort analysis and graphic computation software, as well as with physical models. Thus, the current research contributes to the improvement of architectural solutions aimed at using passive energy strategies in order to offer both better quality for the users and for the sustainability of the planet

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The recent tendency to utilize parking lots for other purposes has demonstrated that more time has been spent by visitors, mainly in great cities. Therefore, this paper investigates the thermal comfort and the air quality indoors in areas specifically used as parking lots by analyzing the direct relation between such environments and vehicular pollution. The thermal comfort and the quality of air indoors in parking lots with different architectonic typology (ground-floor and underground) are also studied, aiming to contribute to the proposition of suitable new areas designated to human usage. Field research was done, in two distinct periods within different weather conditions (January and July) in, two naturally cooled, parking lots located in Natal - RN. The internal environment agents were measured by using tools for air temperature, humidity, speed and direction; interviews with employees and visitors and chemical analysis through appropriate tools to analyze specific material, carbon monoxide and ozone. The results showed that chemical agents densely concentrate mostly in the closed parking space, aggravated by weather conditions, which dissatisfied the visitors. Still, it was shown that architectonic typology, alongside topographical aspects compromise internal environmental conditions, which increases the retention of pollution, leading to dissatisfactory thermal comfort levels and becoming less suitable for usage by visitors considering air and thermal comfort aspects. Consequently, they are not suitable for human stay due to the poor quality of the indoor air