852 resultados para supported molybdenum nitride
Resumo:
The Economic Commission for Latin America and the Caribbean (ECLAC), Subregional Headquarters for the Caribbean, held a two-day expert group meeting on Millennium Development Goals (MDG) monitoring and reporting with a particular focus on health-related indicators in Port of Spain, Trinidad and Tobago, on 16-17 June 2009. This meeting was convened within the framework of the United Nations Development Account-funded project ‘Strengthening the Capacity of National Statistical Offices in the Caribbean Small Island Developing States to fulfil the Millennium Development Goals (MDGs) and other Internationally Agreed Development Goals (IADGs)’.
Resumo:
eLAC 2018 will coordinate the implementation of programmes to support the use of information and communications technologies (ICTs) in achieving social and economic development goals for Latin America in the Caribbean during the 2015-2018 timeframe. The conceptual framework for this programme of work is described by the eLAC 2018 Digital Agenda, which is anticipated to be ratified by the fifth Ministerial Conference on the Information Society in Latin America and the Caribbean, to be held in August 2015 in Mexico City. There is a need for broader input from Caribbean countries to the eLAC 2018 Digital Agenda. Accordingly, this working paper reviews the document’s current draft, considering each of its objectives in the context of Caribbean development needs. Amendments are recommended to 12 of the objectives. Two additional objectives are also proposed, in the areas of regional coordination on universal service funds, and the establishment of a spatial data infrastructure to support the use of geographic information systems. Representatives of Caribbean countries are invited to use the contents of this document as an input to the development of their own proposed amendments for inclusion in the final version of the eLAC 2018 Digital Agenda.
Resumo:
The pristine boron nitride nanotubes have a large direct band gap around 5 eV. This band gap can be engineered by doping. We investigate electronic structure of the doped hexagonal boron nitride (5,5) nanotubes using the linearized augmented cylindrical wave method. In particular, this work focuses on systematical study of the band gap and the density of states around the Fermi-level when the nanotubes are doped by intrinsic impurities of two substitutional boron atoms in a super cell and a comparative analysis of the relative stability of three structures studied here. This corresponds to 3.3% of impurity concentration. We calculate 29 configurations of the nanotubes with different positions of the intrinsic impurities in the nanotube. The band gap and density of states around the Fermi level show strong dependence on the relative positions of the impurity atoms. The two defect sub bands called D∏(B) appear in the band gap of the pristine nanotube. The doped nanotubes possess p-type semiconductor properties with the band gap of 1.3-1.9 eV.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Moderate and controlled loading environments support or enhance osteogenesis, and, consequently, a high degree of bone-to-implant contact can be acquired. This is because when osteoprogenitor cells are exposed to limited physical deformation, their differentiation into osteoblasts is enhanced. Then, some range of microstrain is considered advantageous for bone ingrowth and osseointegration. The primary stability has been considered one of the main clinical means of controlling micromotion between the implant and the forming interfacial tissue, which helps to establish the proper mechanical environment for osteogenesis. Based on the biological aspects of immediate loading (IL), the objective of this study is to present a clinical case of maxillary arch rehabilitation using immediate loading with implant-supported fixed restoration after bone graft. Ten dental implants were placed in the maxilla 6 months after the autogenous bone graft, removed from the mandible (bilateral oblique line and chin), followed by the installation of an immediate-load fixed cross-arch implant-supported restoration because primary stability was reached for 8 implants. In addition, instructions about masticatory function and how it is related to interfacial micromotion were addressed and emphasized to the patient. The reasons for the IL were further avoidance of an interim healing phase, a potential reduction in the number of clinical interventions for the patient, and aesthetic reasons. After monitoring the rehabilitation for 8 years, the authors can conclude that maxillary IL can be performed followed by a well-established treatment planning based on computed tomography, providing immediate esthetics and function to the patient even when autogenous bone graft was previously performed in the maxilla.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: This study aimed to evaluate the role of the implant/abutment system on torque maintenance of titanium retention screws and the vertical misfit of screw-retained implant-supported crowns before and after mechanical cycling. Materials and Methods: Three groups were studied: morse taper implants with conical abutments (MTC group), external-hexagon implants with conical abutments (EHC group), and external-hexagon implants with UCLA abutments (EHU group). Metallic crowns casted in cobalt-chromium alloy were used (n = 10). Retention screws received insertion torque and, after 3 minutes, initial detorque was measured. Crowns were retightened and submitted to cyclic loading testing under oblique loading (30 degrees) of 130 +/- 10 N at 2 Hz of frequency, totaling 1 x 10(6) cycles. After cycling, final detorque was measured. Vertical misfit was measured using a stereomicroscope. Data were analyzed by analysis of variance, Tukey test, and Pearson correlation test (P < .05). Results: All detorque values were lower than the insertion torque both before and after mechanical cycling. No statistically significant difference was observed among groups before mechanical cycling. After mechanical cycling, a statistically significantly lower loss of detorque was verified in the MTC group in comparison to the EHC group. Significantly lower vertical misfit values were noted after mechanical cycling but there was no difference among groups. There was no significant correlation between detorque values and vertical misfit. Conclusions: All groups presented a significant decrease of torque before and after mechanical cycling. The morse taper connection promoted the highest torque maintenance. Mechanical cycling reduced the vertical misfit of all groups, although no significant correlation between vertical misfit and torque loss was found.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: To evaluate and compare the reliability of implant-supported single crowns cemented onto abutments retained with coated (C) or noncoated (NC) screws and onto platform-switched abutments with coated screws. Materials and Methods: Fifty-four implants (DT Implant 4-mm Standard Platform, Intra-Lock International) were divided into three groups (n = 18 each) as follows: matching-platform abutments secured with noncoated abutment screws (MNC); matching-platform abutments tightened with coated abutment screws (MC); and switched-platform abutments secured with coated abutment screws (SC). Screws were characterized by scanning electron microscopy and x-ray photoelectron spectroscopy (XPS). The specimens were subjected to step-stress accelerated life testing. Use-level probability Weibull curves and reliability for 100,000 cycles at 200 N and 300 N (90% two-sided confidence intervals) were calculated. Polarized light and scanning electron microscopes were used for fractographic analysis. Results: Scanning electron microscopy revealed differences in surface texture; noncoated screws presented the typical machining grooves texture, whereas coated screws presented a plastically deformed surface layer. XPS revealed the same base components for both screws, with the exception of higher degrees of silicon in the SiO2 form for the coated samples. For 100,000 cycles at 300 N, reliability values were 0.06 (0.01 to 0.16), 0.25 (0.09 to 0.45), and 0.25 (0.08 to 0.45), for MNC, MC, and SC, respectively. The most common failure mechanism for MNC was fracture of the abutment screw, followed by bending, or its fracture, along with fracture of the abutment or implant. Coated abutment screws most commonly fractured along with the abutment, irrespective of abutment type. Conclusion: Reliability was higher for both groups with the coated screw than with the uncoated screw. Failure modes differed between coated and uncoated groups.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The aim of this study was to evaluate the effects that splinting and different lengths of implants have on the stress distribution in implant-supported prostheses by photoelastic analysis. A total of five photoelastic resin models were made with different proposed situations, and 400 load applications were performed for the analysis. Compared with the unitary prosthesis, the splinted implant-supported prosthesis acted favorably in the distribution of stresses and strains to the implant (p < 0.001). The increase in length was a significant factor in the stress distribution (p < 0.05) and, ultimately, the overall reduction in stress. It was concluded that the splinted implant-supported prosthesis behaved better biomechanically compared with the unitary prosthesis.
Resumo:
The aim of this study was to assess the impact of replacing conventional mandibular complete dentures with implant-supported fixed complete dentures (ISFDs) on the oral health related quality of life (OHOOL) of edentulous patients and on the associated kinesiographic parameters. The patients had their complete dentures replaced by ISFDs and were assessed after 1, 2, 3, 6, and 12 months. An improvement of general OHQOL was observed 2 months after treatment with ISFDs. Kinesiographic recordings revealed significant mandibular vertical and horizontal opening increases and a greater vertical intrusion of the maxillary complete dentures during clenching after the treatment with ISFD.