998 resultados para success measurement
Resumo:
Purpose: To evaluate the sensitivity of the perfusion parameters derived from Intravoxel Incoherent Motion (IVIM) MR imaging to hypercapnia-induced vasodilatation and hyperoxygenation-induced vasoconstriction in the human brain. Materials and Methods: This study was approved by the local ethics committee and informed consent was obtained from all participants. Images were acquired with a standard pulsed-gradient spin-echo sequence (Stejskal-Tanner) in a clinical 3-T system by using 16 b values ranging from 0 to 900 sec/mm(2). Seven healthy volunteers were examined while they inhaled four different gas mixtures known to modify brain perfusion (pure oxygen, ambient air, 5% CO(2) in ambient air, and 8% CO(2) in ambient air). Diffusion coefficient (D), pseudodiffusion coefficient (D*), perfusion fraction (f), and blood flow-related parameter (fD*) maps were calculated on the basis of the IVIM biexponential model, and the parametric maps were compared among the four different gas mixtures. Paired, one-tailed Student t tests were performed to assess for statistically significant differences. Results: Signal decay curves were biexponential in the brain parenchyma of all volunteers. When compared with inhaled ambient air, the IVIM perfusion parameters D*, f, and fD* increased as the concentration of inhaled CO(2) was increased (for the entire brain, P = .01 for f, D*, and fD* for CO(2) 5%; P = .02 for f, and P = .01 for D* and fD* for CO(2) 8%), and a trend toward a reduction was observed when participants inhaled pure oxygen (although P > .05). D remained globally stable. Conclusion: The IVIM perfusion parameters were reactive to hyperoxygenation-induced vasoconstriction and hypercapnia-induced vasodilatation. Accordingly, IVIM imaging was found to be a valid and promising method to quantify brain perfusion in humans. © RSNA, 2012.
Resumo:
AIM: To discuss the use of new ultrasonic techniques that make it possible to visualize elastic (carotid) and muscular (radial) capacitance arteries non-invasively. RESULTS OF DATA REVIEW: Measurements of carotid wall thickness and the detection of atheromas are related to arterial pressure, to other risk factors and to the risk of subsequent complications. The use of high-frequency ultrasound (7.5-10 MHz), measurements of far wall thicknesses in areas free of atheromas at end-diastole (by ECG gating or pressure waveform recording) and descriptions of the size and characteristics of atherosclerotic plaques allow a non-invasive assessment of vascular hypertrophy and atherosclerosis in hypertensive patients. CONCLUSIONS: Careful attention to methodologic and physiologic factors is needed to provide accurate information about the anatomy of the dynamically pulsating arterial tree.
Resumo:
We analyze how a contest organizer chooses optimally the winner when the contestants' efforts are already exerted and commitment to the use of a given contest success function is not possible. We de…ne the notion of rationalizability in mixed-strategies to capture such a situation. Our approach allows to derive different contest success functions depending on the aims and attitudes of the decider. We derive contest success functions which are closely related to commonly used functions providing new support for them. By taking into account social welfare considerations our approach bridges the contest literature and the recent literature on political economy. Keywords: Endogenous Contests, Contest Success Function, Mixed-Strategies. JEL Classi…cation: C72 (Noncooperative Games), D72 (Economic Models of Political Processes: Rent-Seeking, Elections), D74 (Conflict; Conflict Resolution; Alliances)
Resumo:
In a recent paper Tishler and Milstein (2009) fi…nd that increased competition may increase aggregate R&D spending while market output decreases. Therefore, they obtain the surprising result that R&D spending is excessive when competition becomes intense. Their result is based on the standard linear demand function for differentiated products introduced by Bowley (1924) where decreased product differentiation is interpreted as more competitive pressure. In this paper I show that at an aggregate level this interpretation is problematic because equilibrium effects are dominated by a demand reduction effect. A slight modifi…cation of the standard demand function eliminates this effect. For the Tishler and Milstein (2009) setting it is shown that then increased competition increases both R&D spending and aggregate market output. Therefore, at least for consumers, more intense competition increases welfare. Journal of Economic Literature Classi…fication Numbers: D43, L1, O3. Keywords: Oligopoly markets, Product differentiation, Competitive pressure.
Resumo:
Hypoglycemia, if recurrent, may have severe consequences on cognitive and psychomotor development of neonates. Therefore, screening for hypoglycemia is a daily routine in every facility taking care of newborn infants. Point-of-care-testing (POCT) devices are interesting for neonatal use, as their handling is easy, measurements can be performed at bedside, demanded blood volume is small and results are readily available. However, such whole blood measurements are challenged by a wide variation of hematocrit in neonates and a spectrum of normal glucose concentration at the lower end of the test range. We conducted a prospective trial to check precision and accuracy of the best suitable POCT device for neonatal use from three leading companies in Europe. Of the three devices tested (Precision Xceed, Abbott; Elite XL, Bayer; Aviva Nano, Roche), Aviva Nano exhibited the best precision. None completely fulfilled the ISO-accuracy-criteria 15197: 2003 or 2011. Aviva Nano fulfilled these criteria in 92% of cases while the others were <87%. Precision Xceed reached the 95% limit of the 2003 ISO-criteria for values ≤4.2 mmol/L, but not for the higher range (71%). Although validated for adults, new POCT devices need to be specifically evaluated on newborn infants before adopting their routine use in neonatology.
Resumo:
Zero correlation between measurement error and model error has been assumed in existing panel data models dealing specifically with measurement error. We extend this literature and propose a simple model where one regressor is mismeasured, allowing the measurement error to correlate with model error. Zero correlation between measurement error and model error is a special case in our model where correlated measurement error equals zero. We ask two research questions. First, we wonder if the correlated measurement error can be identified in the context of panel data. Second, we wonder if classical instrumental variables in panel data need to be adjusted when correlation between measurement error and model error cannot be ignored. Under some regularity conditions the answer is yes to both questions. We then propose a two-step estimation corresponding to the two questions. The first step estimates correlated measurement error from a reverse regression; and the second step estimates usual coefficients of interest using adjusted instruments.
Resumo:
This study aimed to design and validate the measurement of ankle kinetics (force, moment, and power) during consecutive gait cycles and in the field using an ambulatory system. An ambulatory system consisting of plantar pressure insole and inertial sensors (3D gyroscopes and 3D accelerometers) on foot and shank was used. To test this system, 12 patients and 10 healthy elderly subjects wore shoes embedding this system and walked many times across a gait lab including a force-plate surrounded by seven cameras considered as the reference system. Then, the participants walked two 50-meter trials where only the ambulatory system was used. Ankle force components and sagittal moment of ankle measured by ambulatory system showed correlation coefficient (R) and normalized RMS error (NRMSE) of more than 0.94 and less than 13% in comparison with the references system for both patients and healthy subjects. Transverse moment of ankle and ankle power showed R>0.85 and NRMSE<23%. These parameters also showed high repeatability (CMC>0.7). In contrast, the ankle coronal moment of ankle demonstrated high error and lower repeatability. Except for ankle coronal moment, the kinetic features obtained by the ambulatory system could distinguish the patients with ankle osteoarthritis from healthy subjects when measured in 50-meter trials. The proposed ambulatory system can be easily accessible in most clinics and could assess main ankle kinetics quantities with acceptable error and repeatability for clinical evaluations. This system is therefore suggested for field measurement in clinical applications.
Resumo:
OBJECTIVES: The purpose of this study was to assess short- and mid-term results of in-situ revascularisation (ISR) using silver-coated Dacron prostheses and bowel repair for management of secondary aorto-enteric fistulae (SAEF). DESIGN: Single-centre retrospective chart review. MATERIAL AND METHODS: This study includes all the patients treated by ISR using silver-coated Dacron for SAEF between 2006 and 2010. Primary end points were mortality and survival rates. Secondary end points were reinfection-free survival and secondary patency rates. RESULTS: Eighteen male patients with SAEF with a median age of 64 years were operated by ISR using silver-coated Dacron during the study period without operative death. The 30-day mortality was 22% and the in-hospital mortality rate was 39%. Indeed, during hospitalisation, a duodenal leak was observed in four patients including three who died. Four others patients died due to multi-system organ failure. Median follow-up was 16 months (range 1-66). The survival rate at 12 months was 55%. One duodenal leak was observed leading to death. The reinfection-free survival and the secondary patency rates at 12 months were 60% and 89%, respectively. CONCLUSION: In-situ revascularisation with silver-coated Dacron provides acceptable results in terms of mortality. This treatment may be useful for simple vascular reconstruction and allow greater attention to bowel repair that is a determinant in short- and mid-term survival.
Resumo:
Hypoglycaemia is a major cause of neonatal morbidity and may induce long-term developmental sequelae. Clinical signs of hypoglycaemia in neonatal infants are unspecific or even absent, and therefore, precise and accurate methods for the assessment of glycaemia are needed. Glycaemia measurement in newborns has some particularities like a very low limit of normal glucose concentration compared to adults and a large range of normal haematocrit values. Many bedside point-of-care testing (POCT) systems are available, but literature about their accuracy in newborn infants is scarce and not very convincing. In this retrospective study, we identified over a 1-year study period 1,324 paired glycaemia results, one obtained at bedside with one of three different POCT systems (Elite? XL, Ascensia? Contour? and ABL 735) and the other in the central laboratory of the hospital with the hexokinase reference method. All three POCT systems tended to overestimate glycaemia values, and none of them fulfilled the ISO 15197 accuracy criteria. The Elite XL appeared to be more appropriate than Contour to detect hypoglycaemia, however with a low specificity. Contour additionally showed an important inaccuracy with increasing haematocrit. The bench analyzer ABL 735 was the most accurate of the three tested POCT systems. Both of the tested handheld glucometers have important drawbacks in their use as screening tools for hypoglycaemia in newborn infants. ABL 735 could be a valuable alternative, but the blood volume needed is more than 15 times higher than for handheld glucometers. Before daily use in the newborn population, careful clinical evaluation of each new POCT system for glucose measurement is of utmost importance.
Resumo:
RésuméLes sténoses des voies lacrymales sont fréquentes surtout chez les patients âgés et provoquent en général un epiphora avec parfois des dacryocystites aiguës ou chroniques. La dacryocystorhinostomie par voie externe (DCREX) a été la technique de choix pour traiter les sténoses post-canaliculaires au XXe siècle. Avec l'avènement de l'endoscopie nasale, l'abord endonasal est devenu facilement accessible et depuis une dizaine d'années, la dacryocystorhinostomie par voie endonasale (DCREN) est en train de supplanter la DCREX dans la majorité des cas.Le but de ce travail est de déterminer les étiologies des sténoses des voies lacrimales, d'évaluer le taux de succès et les complications de la DCREN et de détailler les gestes associés peropératoires.Cette étude rétrospective porte sur 98 patients ayant subi 104 DCREN entre janvier 1994 et février 2006. 78 patients (53 femmes et 25 hommes) présentant 84 sténoses post- canaliculaires remplissent les critères d'inclusion de l'étude. L'âge moyen est de 59 ans (4 - 89 ans).Les résultats obtenus montrent un taux de succès fonctionnel de 94.9% après une première intervention (59/84 DCREN) et de 63.6% pour les DCREN secondaires qui nous ont été référées après d'autres interventions des voies lacrymales (25/84 DCREN). Le suivi postopératoire est de 36,8 mois (12-77 mois). On dénombre 61 gestes rhino-sinusaux associés à la DCREN. Les complications per- et postopératoires sont rares, essentiellement liées aux drains bicanaliculaires. Une étiologie n'a été retrouvée que dans 28% des cas.En conclusion, la DCREN donne d'excellents résultats et peu de complications. En raison des nombreux avantages par rapport à la voie externe et la possibilité du traitement simultané de la pathologie ORL parfois associée, la DCREN est devenue le traitement de premier choix pour les sténoses postcanaliculaires. Le principal défi, quelque soit le type de DCR, est de poser la bonne indication opératoire et en cas d'échec opératoire savoir méticuleusement analyser ses causes
Resumo:
PURPOSE: To evaluate the effects of recent advances in magnetic resonance imaging (MRI) radiofrequency (RF) coil and parallel imaging technology on brain volume measurement consistency. MATERIALS AND METHODS: In all, 103 whole-brain MRI volumes were acquired at a clinical 3T MRI, equipped with a 12- and 32-channel head coil, using the T1-weighted protocol as employed in the Alzheimer's Disease Neuroimaging Initiative study with parallel imaging accelerations ranging from 1 to 5. An experienced reader performed qualitative ratings of the images. For quantitative analysis, differences in composite width (CW, a measure of image similarity) and boundary shift integral (BSI, a measure of whole-brain atrophy) were calculated. RESULTS: Intra- and intersession comparisons of CW and BSI measures from scans with equal acceleration demonstrated excellent scan-rescan accuracy, even at the highest acceleration applied. Pairs-of-scans acquired with different accelerations exhibited poor scan-rescan consistency only when differences in the acceleration factor were maximized. A change in the coil hardware between compared scans was found to bias the BSI measure. CONCLUSION: The most important findings are that the accelerated acquisitions appear to be compatible with the assessment of high-quality quantitative information and that for highest scan-rescan accuracy in serial scans the acquisition protocol should be kept as consistent as possible over time. J. Magn. Reson. Imaging 2012;36:1234-1240. ©2012 Wiley Periodicals, Inc.
Resumo:
Background: Urinary human chorionic gonadotropin (hCG) concentration is routinely measured in all anti-doping laboratories to exclude the misuse of recombinant or urinary hCG preparations. In this study, extended validation of two commercial immunoassays for hCG measurements in urine was performed. Both tests were initially designed for hCG determination in human serum/plasma. Methods: Access (R) and Elecsys (R) 1010 are two automated immunoanalysers for central laboratories. The limits of detection and quantification, as well as intra-laboratory and inter-technique correlation, precision, and accuracy, were determined. Stability studies of hCG in urine following freezing and thawing cycles (n = 3) as well as storage conditions at room temperature, 4 degrees C and 20 degrees C, were performed. Results: Statistical evaluation of hCG concentrations in male urine samples (n = 2429) measured with the Elecsys (R) 1010 system enabled us to draw a skewed frequency histogram and establish a far outside value equal to 2.3 IU/L. This decision limit corresponds to the concentration at which a sportsman will be considered positive for hCG. Intra-assay precision for the Access (R) analyser was less than 4.0 A, whereas the inter-assay precision was closer to 4.5 % (concentrations of the official external controls contained between 5.5 and 195.0 IU/L). Intra and inter-assay precision for the Elecsys (R) 1010 analyser was slightly better. A good inter-technique correlation was obtained when measuring various urine samples (male and female). No urinary hCG loss was observed after two freeze/thaw cycles. On the other hand, time and inappropriate storage conditions, such as temperatures above 10 degrees C for more than 5 days, can deteriorate urinary hCG. Conclusions: Both analysers showed acceptable performances and are suitable for screening urine for anti-doping analyses. Each laboratory should validate and establish its own reference values because hCG concentrations measured in urine can be different from one immunoassay to another. The time delay between urine collection and analysis should be reduced as much as possible, and urine samples should be transported in optimal conditions to avoid a loss of hCG immunoreactivity.