382 resultados para spinner dolphin
Resumo:
Marjorie Daw.--Little violinist.--Our new neighbors at Ponkapog.--A Christmas fantasy, with a moral.--Goliath.--The cruise of the dolphin.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
Added engraved title-page representing Arion and the dolphin surmounted by the arms of the Dauphin.
Resumo:
Printer's device (anchor & dolphin) on each t.p.
Resumo:
In publisher's illustrated binding, no publisher's ads at end.
Resumo:
This paper provides a profit-maximizing model with vessel-level dolphin mortality limits for purse seiners harvesting tunas in the eastern tropical Pacific Ocean. The model analytically derives the shadow price (estimated economic value) for dolphin mortality, the fishing-fleet size, and the annual tuna harvest as functions of a few key fishing parameters. The model also provides a statistical method to determine the accuracy of all needed parameter estimates. The paper then applies the model to the year 1996 and the period from 1985 to 1987. The shadow price measures the economic value to the US tuna fleet of dolphins lost in the harvesting of tuna. This value is essential when attempting to evaluate the economic benefits and costs to society of any action designed to reduce the mortality of dolphins in the harvesting of tuna in the eastern tropical Pacific Ocean.
Resumo:
La Sequenza Sismica Emiliana del 2012 ha colpito la zona compresa tra Mirandola e Ferrara con notevoli manifestazioni cosismiche e post-sismiche secondarie, soprattutto legate al fenomeno della liquefazione delle sabbie e alla formazione di fratturazioni superficiali del terreno. A fronte del fatto che la deformazione principale, osservata tramite tecniche di remote-sensing, ha permesso di individuare la posizione della struttura generatrice, ci si è interrogati sul rapporto tra strutture profonde e manifestazioni secondarie superficiali. In questa tesi è stato svolto un lavoro di integrazione di dati a varia scala, dalla superficie al sottosuolo, fino profondità di alcuni chilometri, per analizzare il legame tra le strutture geologiche che hanno generato il sisma e gli effetti superficiali percepiti dagli osservatori. Questo, non solo in riferimento allo specifico del sisma emiliano del 2012, ma al fine di trarre utili informazioni in una prospettiva storica e geologica sugli effetti di un terremoto “tipico”, in una regione dove le strutture generatrici non affiorano in superficie. Gli elementi analizzati comprendono nuove acquisizioni e rielaborazioni di dati pregressi, e includono cartografie geomorfologiche, telerilevamenti, profili sismici a riflessione superficiale e profonda, stratigrafie e informazioni sulla caratterizzazione dell’area rispetto al rischio sismico. Parte dei dati di nuova acquisizione è il risultato dello sviluppo e la sperimentazione di metodologie innovative di prospezione sismica in corsi e specchi d’acqua continentali, che sono state utilizzate con successo lungo il Cavo Napoleonico, un canale artificiale che taglia ortogonalmente la zona di massima deformazione del sisma del 20 Maggio. Lo sviluppo della nuova metodologia di indagine geofisica, applicata ad un caso concreto, ha permesso di migliorare le tecniche di imaging del sottosuolo, oltre a segnalare nuove evidenze co-sismiche che rimanevano nascoste sotto le acque del canale, e a fornire elementi utili alla stratigrafia del terreno. Il confronto tra dati geofisici e dati geomorfologici ha permesso di cartografare con maggiore dettaglio i corpi e le forme sedimentarie superficiali legati alla divagazione fluviale dall’VIII sec a.C.. I dati geofisici, superficiali e profondi, hanno evidenziato il legame tra le strutture sismogeniche e le manifestazioni superficiali seguite al sisma emiliano. L’integrazione dei dati disponibili, sia nuovi che da letteratura, ha evidenziato il rapporto tra strutture profonde e sedimentazione, e ha permesso di calcolare i tassi geologici di sollevamento della struttura generatrice del sisma del 20 Maggio. I risultati di questo lavoro hanno implicazioni in vari ambiti, tra i quali la valutazione del rischio sismico e la microzonazione sismica, basata su una caratterizzazione geomorfologico-geologico-geofisica dettagliata dei primi 20 metri al di sotto della superficie topografica. Il sisma emiliano del 2012 ha infatti permesso di riconoscere l’importanza del substrato per lo sviluppo di fenomeni co- e post-sismici secondari, in un territorio fortemente eterogeneo come la Pianura Padana.
Resumo:
O objetivo deste estudo prospectivo foi avaliar os efeitos do aparelho Forsus® nos incisivos centrais superiores e inferiores. A amostra constituiu-se de 22 tomografias computadorizadas de 11 pacientes (sexo masculino e feminino) idade média de 15,8 anos com má oclusão de Classe II que foram tratados com o aparelho Forsus® na clínica do programa de pós-graduação em Odontologia, área de concentração Ortodontia, da Universidade Metodista de São Paulo. As tomografias foram obtidas em dois momentos T1 (final de nivelamento e antes da instalação do Forsus® e T2 (remoção do Forsus®). Para avaliar a distância do ápice até a tábua óssea, as imagens a serem examinadas foram obtidas com o auxílio do viewer do próprio i-CAT® , o iCATVision® e examinadas com o CorelDRAW X5® já para as medidas cefalométricas IMPA e 1.PP as imagens cefalométricas ortogonais foram obtidas em proporção 1:1 com auxílio do software Dolphin 3D® (Dolphin Imaging and Management Solutions, Chatsworth, EUA) e em seguida examinadas com o software Radiocef Studio 2 (Radio Memory, Belo Horizonte, Brasil). Para a obtenção do erro intra-examinador foi feito o teste t de Student pareado para o erro sistemático e a fórmula de DAHLBERG para estimar a ordem de grandeza dos erros casuais e na análise estatística dos resultados utilizou-se: o teste t para a determinação das diferenças entres as fases de observação e o teste de correlação de Pearson para avaliar a correlação entres as alterações. Observou-se: um aumento significativo (p<0,05) tanto no IMPA quanto no 1.PP, aproximação do ápice dos incisivos inferiores da tábua óssea lingual, aproximação do ápice dos incisivos superiores da tábua óssea vestibular, uma correlação negativa muito forte entre o IMPA e a distância do ápice do incisivo até a tábua óssea lingual e uma correlação negativa moderada entre 1.PP e a distância do ápice do incisivo até a tábua óssea vestibular. Sendo assim o aparelho Forsus® no tratamento da Classe II teve como efeito: vestibularização significativa dos incisivos centrais inferiores, uma verticalização significativa dos incisivos centrais superiores, aproximação do ápice dos incisivos inferiores da cortical óssea lingual e aproximação do ápice dos incisivos superiores da cortical óssea vestibular.
Resumo:
Mouse embiyonic stem (ES) cells have the potential to differentiate into insulin-producing cells, but efficient protocols for in vitro differentiation have not been established. Here we have developed a new optimized four-stage differentiation protocol and compared this with an established reference protocol. The new protocol minimized differentiation towards neuronal progeny, resulting in a population of insulin-producing cells with ß-cell characteristics but lacking neuronal features. The yield of glucagon and somatostatin cells was negligible. Crucial for this improved yield was the removal of a nestin selection step as well as removal of culture supplements that promote differentiation towards the neuronal lineage. Supplementation of the differentiation medium with insulin and fetal calf serum was beneficial for differentiation towards monohor-monal insulin-positive cells. After implantation into diabetic mice these insulin-producing cells produced a time-dependent improvement of the diabetic metabolic state, in contrast to cells differentiated according to the reference protocol. Using a spinner culture instead of an adherent culture of ES cells prevented the differentiation towards insulin-producing cells. Thus, prevention of cell attachment in a spinner culture represents a means to keep ES cells in an undifferentiated state and to inhibit differentiation. In conclusion, this study describes a new optimized four-stage protocol for differentiating ES cells to insulin-producing cells with minimal neuronal cell formation. Copyright © 2008 Cognizant Comm. Corp.
Resumo:
Human mesenchymal stem cell (hMSC) therapies are currently progressing through clinical development, driving the need for consistent, and cost effective manufacturing processes to meet the lot-sizes required for commercial production. The use of animal-derived serum is common in hMSC culture but has many drawbacks such as limited supply, lot-to-lot variability, increased regulatory burden, possibility of pathogen transmission, and reduced scope for process optimization. These constraints may impact the development of a consistent large-scale process and therefore must be addressed. The aim of this work was therefore to run a pilot study in the systematic development of serum-free hMSC manufacturing process. Human bone-marrow derived hMSCs were expanded on fibronectin-coated, non-porous plastic microcarriers in 100mL stirred spinner flasks at a density of 3×105cells.mL-1 in serum-free medium. The hMSCs were successfully harvested by our recently-developed technique using animal-free enzymatic cell detachment accompanied by agitation followed by filtration to separate the hMSCs from microcarriers, with a post-harvest viability of 99.63±0.03%. The hMSCs were found to be in accordance with the ISCT characterization criteria and maintained hMSC outgrowth and colony-forming potential. The hMSCs were held in suspension post-harvest to simulate a typical pooling time for a scaled expansion process and cryopreserved in a serum-free vehicle solution using a controlled-rate freezing process. Post-thaw viability was 75.8±1.4% with a similar 3h attachment efficiency also observed, indicating successful hMSC recovery, and attachment. This approach therefore demonstrates that once an hMSC line and appropriate medium have been selected for production, multiple unit operations can be integrated to generate an animal component-free hMSC production process from expansion through to cryopreservation.
Resumo:
The use of hMSCs for allogeneic therapies requiring lot sizes of billions of cells will necessitate large-scale culture techniques such as the expansion of cells on microcarriers in bioreactors. Whilst much research investigating hMSC culture on microcarriers has focused on growth, much less involves their harvesting for passaging or as a step towards cryopreservation and storage. A successful new harvesting method has recently been outlined for cells grown on SoloHill microcarriers in a 5L bioreactor [1]. Here, this new method is set out in detail, harvesting being defined as a two-step process involving cell 'detachment' from the microcarriers' surface followed by the 'separation' of the two entities. The new detachment method is based on theoretical concepts originally developed for secondary nucleation due to agitation. Based on this theory, it is suggested that a short period (here 7min) of intense agitation in the presence of a suitable enzyme should detach the cells from the relatively large microcarriers. In addition, once detached, the cells should not be damaged because they are smaller than the Kolmogorov microscale. Detachment was then successfully achieved for hMSCs from two different donors using microcarrier/cell suspensions up to 100mL in a spinner flask. In both cases, harvesting was completed by separating cells from microcarriers using a Steriflip® vacuum filter. The overall harvesting efficiency was >95% and after harvesting, the cells maintained all the attributes expected of hMSC cells. The underlying theoretical concepts suggest that the method is scalable and this aspect is discussed too. © 2014 The Authors.
Resumo:
For the first time, fully functional human mesenchymal stem cells (hMSCs) have been cultured at the litre-scale on microcarriers in a stirred-tank 5 l bioreactor, (2.5 l working volume) and were harvested via a potentially scalable detachment protocol that allowed for the successful detachment of hMSCs from the cell-microcarrier suspension. Over 12 days, the dissolved O2 concentration was >45 % of saturation and the pH between 7.2 and 6.7 giving a maximum cell density in the 5 l bioreactor of 1.7 × 105 cells/ml; this represents >sixfold expansion of the hMSCs, equivalent to that achievable from 65 fully-confluent T-175 flasks. During this time, the average specific O2 uptake of the cells in the 5 l bioreactor was 8.1 fmol/cell h and, in all cases, the 5 l bioreactors outperformed the equivalent 100 ml spinner-flasks run in parallel with respect to cell yields and growth rates. In addition, yield coefficients, specific growth rates and doubling times were calculated for all systems. Neither the upstream nor downstream bioprocessing unit operations had a discernible effect on cell quality with the harvested cells retaining their immunophenotypic markers, key morphological features and differentiation capacity. © 2013 Springer Science+Business Media Dordrecht.
Resumo:
In our recent work in different bioreactors up to 2.5L in scale, we have successfully cultured hMSCs using the minimum agitator speed required for complete microcarrier suspension, N
Resumo:
Production of human mesenchymal stem cells for allogeneic cell therapies requires scalable, cost-effective manufacturing processes. Microcarriers enable the culture of anchorage-dependent cells in stirred-tank bioreactors. However, no robust, transferable methodology for microcarrier selection exists, with studies providing little or no reason explaining why a microcarrier was employed. We systematically evaluated 13 microcarriers for human bone marrow-derived MSC (hBM-MSCs) expansion from three donors to establish a reproducible and transferable methodology for microcarrier selection. Monolayer studies demonstrated input cell line variability with respect to growth kinetics and metabolite flux. HBM-MSC1 underwent more cumulative population doublings over three passages in comparison to hBM-MSC2 and hBM-MSC3. In 100 mL spinner flasks, agitated conditions were significantly better than static conditions, irrespective of donor, and relative microcarrier performance was identical where the same microcarriers outperformed others with respect to growth kinetics and metabolite flux. Relative growth kinetics between donor cells on the microcarriers were the same as the monolayer study. Plastic microcarriers were selected as the optimal microcarrier for hBM-MSC expansion. HBM-MSCs were successfully harvested and characterised, demonstrating hBM-MSC immunophenotype and differentiation capacity. This approach provides a systematic method for microcarrier selection, and the findings identify potentially significant bioprocessing implications for microcarrier-based allogeneic cell therapy manufacture. Large-scale production of human bone-marrow derived mesenchymal stem cells (hBM-MSCs) requires expansion on microcarriers in agitated systems. This study demonstrates the importance of microcarrier selection and presents a systematic methodology for selection of an optimal microcarrier. The study also highlights the impact of an agitated culture environment in comparison to a static system, resulting in a significantly higher hBM-MSC yield under agitated conditions.