917 resultados para reliability test system
Resumo:
This thesis is done to solve two issues for Sayid Paper Mill Ltd Pakistan. Section one deals with a practical problem arise in SPM that is cutting a given set of raw paper rolls of known length and width, and a set of product paper rolls of known length (equal to the length of raw paper rolls) and width, practical cutting constraints on a single cutting machine, according to demand orders for all customers. To solve this problem requires to determine an optimal cutting schedule to maximize the overall cutting process profitability while satisfying all demands and cutting constraints. The aim of this part of thesis is to develop a mathematical model which solves this problem.Second section deals with a problem of delivering final product from warehouse to different destinations by finding shortest paths. It is an operational routing problem to decide the daily routes for sending trucks to different destination to deliver their final product. This industrial problem is difficult and includes aspect such as delivery to a single destination and multiple destinations with limited resources. The aim of this part of thesis is to develop a process which helps finding shortest path.
Resumo:
The main idea of this research to solve the problem of inventory management for the paper industry SPM PVT limited. The aim of this research was to find a methodology by which the inventory of raw material could be kept at minimum level by means of buffer stock level.The main objective then lies in finding the minimum level of buffer stock according to daily consumption of raw material, finding the Economic Order Quantity (EOQ) reorders point and how much order will be placed in a year to control the shortage of raw material.In this project, we discuss continuous review model (Deterministic EOQ models) that includes the probabilistic demand directly in the formulation. According to the formula, we see the reorder point and the order up to model. The problem was tackled mathematically as well as simulation modeling was used where mathematically tractable solution was not possible.The simulation modeling was done by Awesim software for developing the simulation network. This simulation network has the ability to predict the buffer stock level based on variable consumption of raw material and lead-time. The data collection for this simulation network is taken from the industrial engineering personnel and the departmental studies of the concerned factory. At the end, we find the optimum level of order quantity, reorder point and order days.
Resumo:
An international standard, ISO/DP 9459-4 has been proposed to establish a uniform standard of quality for small, factory-made solar heating systerns. In this proposal, system components are tested separatelyand total system performance is calculated using system simulations based on component model parameter values validated using the results from the component tests. Another approach is to test the whole system in operation under representative conditions, where the results can be used as a measure of the general system performance. The advantage of system testing of this form is that it is not dependent on simulations and the possible inaccuracies of the models. Its disadvantage is that it is restricted to the boundary conditions for the test. Component testing and system simulation is flexible, but requires an accurate and reliable simulation model.The heat store is a key component conceming system performance. Thus, this work focuses on the storage system consisting store, electrical auxiliary heater, heat exchangers and tempering valve. Four different storage system configurations with a volume of 750 litre were tested in an indoor system test using a six -day test sequence. A store component test and system simulation was carried out on one of the four configurations, applying the proposed standard for stores, ISO/DP 9459-4A. Three newly developed test sequences for intemalload side heat exchangers, not in the proposed ISO standard, were also carried out. The MULTIPORT store model was used for this work. This paper discusses the results of the indoor system test, the store component test, the validation of the store model parameter values and the system simulations.
Resumo:
Dynamic system test methods for heating systems were developed and applied by the institutes SERC and SP from Sweden, INES from France and SPF from Switzerland already before the MacSheep project started. These test methods followed the same principle: a complete heating system – including heat generators, storage, control etc., is installed on the test rig; the test rig software and hardware simulates and emulates the heat load for space heating and domestic hot water of a single family house, while the unit under test has to act autonomously to cover the heat demand during a representative test cycle. Within the work package 2 of the MacSheep project these similar – but different – test methods were harmonized and improved. The work undertaken includes: • Harmonization of the physical boundaries of the unit under test. • Harmonization of the boundary conditions of climate and load. • Definition of an approach to reach identical space heat load in combination with an autonomous control of the space heat distribution by the unit under test. • Derivation and validation of new six day and a twelve day test profiles for direct extrapolation of test results. The new harmonized test method combines the advantages of the different methods that existed before the MacSheep project. The new method is a benchmark test, which means that the load for space heating and domestic hot water preparation will be identical for all tested systems, and that the result is representative for the performance of the system over a whole year. Thus, no modelling and simulation of the tested system is needed in order to obtain the benchmark results for a yearly cycle. The method is thus also applicable to products for which simulation models are not available yet. Some of the advantages of the new whole system test method and performance rating compared to the testing and energy rating of single components are: • Interaction between the different components of a heating system, e.g. storage, solar collector circuit, heat pump, control, etc. are included and evaluated in this test. • Dynamic effects are included and influence the result just as they influence the annual performance in the field. • Heat losses are influencing the results in a more realistic way, since they are evaluated under "real installed" and representative part-load conditions rather than under single component steady state conditions. The described method is also suited for the development process of new systems, where it replaces time-consuming and costly field testing with the advantage of a higher accuracy of the measured data (compared to the typically used measurement equipment in field tests) and identical, thus comparable boundary conditions. Thus, the method can be used for system optimization in the test bench under realistic operative conditions, i.e. under relevant operating environment in the lab. This report describes the physical boundaries of the tested systems, as well as the test procedures and the requirements for both the unit under test and the test facility. The new six day and twelve day test profiles are also described as are the validation results.
Resumo:
Regulatory authorities in many countries, in order to maintain an acceptable balance between appropriate customer service qualities and costs, are introducing a performance-based regulation. These regulations impose penalties, and in some cases rewards, which introduce a component of financial risk to an electric power utility due to the uncertainty associated with preserving a specific level of system reliability. In Brazil, for instance, one of the reliability indices receiving special attention by the utilities is the Maximum Continuous Interruption Duration per customer (MCID). This paper describes a chronological Monte Carlo simulation approach to evaluate probability distributions of reliability indices, including the MCID, and the corresponding penalties. In order to get the desired efficiency, modern computational techniques are used for modeling (UML -Unified Modeling Language) as well as for programming (Object- Oriented Programming). Case studies on a simple distribution network and on real Brazilian distribution systems are presented and discussed. © Copyright KTH 2006.
Resumo:
The system reliability depends on the reliability of its components itself. Therefore, it is necessary a methodology capable of inferring the state of functionality of these components to establish reliable indices of quality. Allocation models for maintenance and protective devices, among others, have been used in order to improve the quality and availability of services on electric power distribution systems. This paper proposes a methodology for assessing the reliability of distribution system components in an integrated way, using probabilistic models and fuzzy inference systems to infer about the operation probability of each component. © 2012 IEEE.
Resumo:
Objectives: To investigate the test-retest reliability of mechanical parameters derived from a 3-min isokinetic all-out test, performed at 60 and 100 rpm. Reliability and validity of the peak oxygen uptake derived from 3-min isokinetic all-out test were also tested. Design: 14 healthy male subjects completed an incremental ramp testing and four randomized 3-min isokinetic all-out test (two at 60 rpm and two at 100 rpm). Methods: The absolute and relative reliability of the following parameters were analyzed: peak power, mean power, end power, fatigue index, work performed above end power and peak oxygen uptake. Results: No difference was found between each two sets of data, although there were between-cadence differences for peak power, mean power, end power, and fatigue index. Higher intra-class correlation (ICC) and lower coefficient of variation (CV) were found for end power (ICC = 0.91 and 0.95; CV = 5.6 and 5.7%) and mean power (ICC = 0.97 and 0.98; CV = 2.4 and 3.1%), than for peak power (ICC = 0.81 and 0.84; CV = 8.7 and 10%) and work performed above end power (ICC = 0.79 and 0.84; CV = 7.9 and 10.6%; values reported for 60 rpm and 100 rpm, respectively). High reliability scores were also observed for peak oxygen uptake at both cadences (60 rpm, CV = 3.2%; 100 rpm, CV = 2.3%,) with no difference with the incremental ramp testing peak oxygen uptake. Conclusions: The power profile and peak oxygen uptake of a 3-min isokinetic all-out test are both highly reliable, whether the test is performed at 60 or 100 rpm. Besides, peak oxygen uptake and work performed above end power were not affected by the change in cadence while peak power, mean power, end power, and fatigue index were. © 2013.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Excessive rearfoot eversion is thought to be a risk factor for patellofemoral pain development, due to the kinesiological relationship with ascendant adaptations. Individuals with patellofemoral pain are often diagnosed through static clinical tests, in scientific studies and clinical practice. However, the adaptations seem to appear in dynamic conditions. Performing static vs. dynamic evaluations of widely used measures would add to the knowledge in this area. Thus, the aim of this study was to determine the reliability and differentiation capability of three rearfoot eversion measures: rearfoot range of motion, static clinical test and static measurement using a three-dimensional system. A total of 29 individuals with patellofemoral pain and 25 control individuals (18-30 years) participated in this study. Each subject underwent three-dimensional motion analysis during stair climbing and static clinical tests. Intraclass correlation coefficient and standard error measurements were performed to verify the reliability of the variables and receiver operating characteristic curves to show the diagnostic accuracy of each variable. In addition, analyses of variance were performed to identify differences between groups. Rearfoot range of motion demonstrated higher diagnostic accuracy (an area under the curve score of 0.72) than static measures and was able to differentiate the groups. Only the static clinical test presented poor and moderate reliability. Other variables presented high to very high values. Rearfoot range of motion was the variable that presented the best results in terms of reliability and differentiation capability. Static variables do not seem to be related to patellofemoral pain and have low accuracy values.
Resumo:
Bertuzzi, R, Franchini, E, Tricoli, V, Lima-Silva, AE, Pires, FDO, Okuno, NM, and Kiss, MAPDM. Fit-climbing test: A field test for indoor rock climbing. J Strength Cond Res 26(6): 1558-1563, 2012-The aim of this study was to develop an indoor rock-climbing test on an artificial wall (Fit-climbing test). Thirteen climbers (elite group [EG] = 6; recreational group [RG] = 7) performed the following tests: (a) familiarization in the Fitclimbing test, (b) the Fit-climbing test, and (c) a retest to evaluate the Fit-climbing test's reliability. Gas exchange, blood lactate concentration, handgrip strength, and heart rate were measured during the test. Oxygen uptake during the Fit-climbing test was not different between groups (EG = 8.4 +/- 1.1 L; RG = 7.9 +/- 1.5 L, p > 0.05). The EG performance (120 +/- 7 movements) was statistically higher than the RG climbers' performance (78 +/- 13 movements) during the Fit-climbing test. Consequently, the oxygen cost per movement during the Fit-climbing test of the EG was significantly lower than that of the RG (p < 0.05). Handgrip strength was higher in the EG when compared with that in the RG in both pre-Fit- and post-Fit-climbing test (p < 0.05). There were no significant differences in any other variables analyzed during the Fit-climbing test (p > 0.05). Furthermore, the performance in the Fit-climbing test presented high reliability (intraclass correlation coefficient = 0.97). Therefore, the performance during the Fit-climbing test may be an alternative to evaluate rock climbers because of its specificity and relation to oxygen cost per movement during climbing.
Resumo:
Chaabene, H, Hachana, Y, Franchini, E, Mkaouer, B, Montassar, M, and Chamari, K. Reliability and construct validity of the karate-specific aerobic test. J Strength Cond Res 26(12): 3454-3460, 2012-The aim of this study was to examine absolute and relative reliabilities and external responsiveness of the Karate-specific aerobic test (KSAT). This study comprised 43 male karatekas, 19 of them participated in the first study to establish test-retest reliability and 40, selected on the bases of their karate experience and level of practice, participated in the second study to identify external responsiveness of the KSAT. The latter group was divided into 2 categories: national-level group (G(n)) and regional-level group (Gr). Analysis showed excellent test-retest reliability of time to exhaustion (TE), with intraclass correlation coefficient ICC(3,1) >0.90, standard error of measurement (SEM) <5%: (3.2%) and mean difference (bias) +/- the 95% limits of agreement: -9.5 +/- 78.8 seconds. There was a significant difference between test-retest session in peak lactate concentration (Peak [La]) (9.12 +/- 2.59 vs. 8.05 +/- 2.67 mmol.L-1; p < 0.05) but not in peak heart rate (HRpeak) and rating of perceived exertion (RPE) (196 +/- 9 vs. 194 +/- 9 b.min(-1) and 7.6 +/- 0.93 vs. 7.8 +/- 1.15; p > 0.05), respectively. National-level karate athletes (1,032 +/- 101 seconds) were better than regional level (841 +/- 134 seconds) on TE performance during KSAT (p < 0.001). Thus, KSAT provided good external responsiveness. The area under the receiver operator characteristics curve was >0.70 (0.86; confidence interval 95%: 0.72-0.95). Significant difference was detected in Peak [La] between national- (6.09 +/- 1.78 mmol.L-1) and regional-level (8.48 +/- 2.63 mmol.L-1) groups, but not in HRpeak (194 +/- 8 vs. 195 +/- 8 b.min(-1)) and RPE (7.57 +/- 1.15 vs. 7.42 +/- 1.1), respectively. The result of this study indicates that KSAT provides excellent absolute and relative reliabilities. The KSAT can effectively distinguish karate athletes of different competitive levels. Thus, the KSAT may be suitable for field assessment of aerobic fitness of karate practitioners.
Resumo:
Background: The six-minute-walk-test (6MWT) has been increasingly used in cystic fibrosis (CF) patients. However, few studies in children have correlated 6MWT with current parameters used to evaluate CF severity. Moreover, no study transformed the values of distance walked from meters into Z scores to avoid bias like age and gender, which are sources of 6MWT variability. Methods: A cross-sectional descriptive study was performed to analyze the correlations (Spearman) among forced expiratory volume in one second (FEV1), body mass index (BMI), chest radiography (CXR), chest tomography (CT), and 6MWT Z score (Z-6MWT). Clinically stable CF patients, aged 6-21 years, were included. Results: 34 patients, 14F/20M, mean age 12.1 +/- 4.0 years were studied. The mean Z-6MWT was -1.1 +/- 1.106. The following correlations versus Z-6MWT were found: FEV1 (r=0.59, r(2)=0.32, p=0.0002), BMI Z score (r=0.42, r(2)=0.17, p=0.013), CXR (r=0.34, r(2)=0.15, p=0.0472) and CT (r=-0.45, r(2)=0.23, p=0.0073). Conclusions: In conclusion there was a significant, but poor, correlation between the six minute walk test Z score and the cystic fibrosis severity markers currently in use. (C) 2011 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Resumo:
Abstract Background Accurate malaria diagnosis is mandatory for the treatment and management of severe cases. Moreover, individuals with asymptomatic malaria are not usually screened by health care facilities, which further complicates disease control efforts. The present study compared the performances of a malaria rapid diagnosis test (RDT), the thick blood smear method and nested PCR for the diagnosis of symptomatic malaria in the Brazilian Amazon. In addition, an innovative computational approach was tested for the diagnosis of asymptomatic malaria. Methods The study was divided in two parts. For the first part, passive case detection was performed in 311 individuals with malaria-related symptoms from a recently urbanized community in the Brazilian Amazon. A cross-sectional investigation compared the diagnostic performance of the RDT Optimal-IT, nested PCR and light microscopy. The second part of the study involved active case detection of asymptomatic malaria in 380 individuals from riverine communities in Rondônia, Brazil. The performances of microscopy, nested PCR and an expert computational system based on artificial neural networks (MalDANN) using epidemiological data were compared. Results Nested PCR was shown to be the gold standard for diagnosis of both symptomatic and asymptomatic malaria because it detected the major number of cases and presented the maximum specificity. Surprisingly, the RDT was superior to microscopy in the diagnosis of cases with low parasitaemia. Nevertheless, RDT could not discriminate the Plasmodium species in 12 cases of mixed infections (Plasmodium vivax + Plasmodium falciparum). Moreover, the microscopy presented low performance in the detection of asymptomatic cases (61.25% of correct diagnoses). The MalDANN system using epidemiological data was worse that the light microscopy (56% of correct diagnoses). However, when information regarding plasma levels of interleukin-10 and interferon-gamma were inputted, the MalDANN performance sensibly increased (80% correct diagnoses). Conclusions An RDT for malaria diagnosis may find a promising use in the Brazilian Amazon integrating a rational diagnostic approach. Despite the low performance of the MalDANN test using solely epidemiological data, an approach based on neural networks may be feasible in cases where simpler methods for discriminating individuals below and above threshold cytokine levels are available.