809 resultados para rating of perceived exertion
Resumo:
Morbidly obese patients present an increase in heart rate, blood pressure and perceived exertion besides lower walking ability compared to normal weight people. However, little is known about how these variables are presented after bariatric surgery. Moreover, despite the distance walked during the six-minute walk (6MWT) improve after surgery is not well established if the level of physical activity influences this improvement. Objective: To evaluate cardiovascular performance, perceived effort, ability of walking and physical activity level of patients with morbid obesity before and after bariatric surgery. Methods: The cardiovascular performance, perception of effort, the ability to walk and level of physical activity were assessed in 22 patients before (BMI = 50.4 kg/m2) and after (BMI = 34.8 kg/m2) bariatric surgery through the 6MWT. The heart rate, blood pressure and perceived exertion were assessed at rest, at the end of the 6MWT and in the second minute post-test (HR recovery). The ability to walk was measured by total distance walked at the end of the test while the level of physical activity was estimated by applying the Baecke questionnaire, analyzing domains occupation, leisure and locomotion and leisure and physical activity. Results: The HR at rest and recovery decreased significantly (91.2 ± 15.8 bpm vs. 71.9 ± 9.8 bpm, 99.5 ± 15.3 bpm vs 82.5 ± 11.1 bpm, respectively), as well as all the arterial pressure and perceived exertion after surgery. The distance achieved by the patients increased by 58.4 m (p = 0.001) postoperatively. Time postoperatively had correlation with the percentage of excess weight lost (r = 0.48, p = 0.02), BMI (r =- 0.68, p = 0.001) and the Baecke (r = 0.52, p = 0.01) which did not happen with the distance walked (r = 0.37, p = 0.09). Despite weight loss, patients showed no difference in the level of physical activity in any of the areas before and after surgery. Conclusion: The cardiovascular performance, the perception of effort and ability to walk seem to improve after bariatric surgery. However, despite improvement in the ability to walk by the distance achieved in the 6MWT after weight loss, this is not reflected in an increase in physical activity level of obese patients after surgery
Resumo:
The term fatigability concerns the degree of fatigue associated with performing an activity of any type (physical, mental, emotional and / or social). Recently scales for assessing fatigue in the English language were created, however, gaps exist regarding the validity of these scales in relation to oxygen consumption and levels of perceived fatigue. Objective: To investigate the validity of perceived fatigability scale in older women frail and non-frail by the expired gases kinetics. Methods: This is a study of type validation, where were evaluated 48 elderly. The evaluation was conducted at two different sessions. In the first, data were collected demographic partners, as well as assessment of cognitive function, physical health, and the phenotype of frailty. The second was composed by the test 6-minute walk (6MWT) associated the expired gases kinects and assessment of perceived fatigability. Statistical analysis was performed a descriptive analysis and then we used the Pearson correlation test to evaluate the relationship between the measure of perceived fatigue and variables oxygen consumption (VO2), carbon dioxide production (VCO2), respiratory exchange ratio (RER)before and after 6MWT. We used a linear regression model initially considering the following explanatory variable: age, Body Mass Index (BMI), presence of frailty, comorbidities, level of physical activity, distance covered in the 6MWT , the energy cost of walking and severity of fatigability on performance. Results: The final sample consisted of 44 elderly women, 4 elderly were excluded because they didn t complete all phases of this study. The mean age obtained was 75 years (± 7.2 years). There was no significant correlation between fatigability measures and the values of VO2 ( r = .09 , p = .56 ) , VCO2 ( r = .173 , p = .26 ) , RER ( r = - .121 , p = .43 ). The final linear regression model showed that the energy cost of walking, the usual level of physical activity and the performance severity of fatigability explained 83.5 % (R2 = 0.835, p < 0.01) of the variation in the perceived fatigability. Conclusion: Our findings indicate a relationship between greater severity of fatigability and lower levels of physical activity and increased energy cost in walking, suggesting that the fatigability analyses using a simple numeric scale is valid and viable for assessment of fatigue in older women
Resumo:
This study investigates the possible differences between actors' and nonactors' vocal projection strategies using acoustic and perceptual analyses. A total of 11 male actors and 10 male nonactors volunteered as subjects, reading an extended text sample in habitual, moderate, and loud levels. The samples were analyzed for sound pressure level (SPL), alpha ratio (difference between the average SPL of the 1-5 kHz region and the average SPL of the 50 Hz-1 kHz region), fundamental frequency (F0), and long-term average spectrum (LTAS). Through LTAS, the mean frequency of the first formant (171) range, the mean frequency of the actor's formant, the level differences between the F1 frequency region and the F0 region (L1-L0), and the level differences between the strongest peak at 0-1 kHz and that at 3-4 kHz were measured. Eight voice specialists evaluated perceptually the degree of projection, loudness, and tension in the samples. The actors had a greater alpha ratio, stronger level of the actor's formant range, and a higher degree of perceived projection and loudness in all loudness levels. SPL, however, did not differ significantly between the actors and nonactors, and no differences were found in the mean formant frequencies ranges. The alpha ratio and the relative level of the actor's formant range seemed to be related to the degree of perceived loudness. From the physiological point of view, a more favorable glottal setting' providing a higher glottal closing speed, may be characteristic of these actors' projected voices. So, the projected voices, in this group of actors, were more related to the glottic source than to the resonance of the vocal tract.
Resumo:
A relação linear entre intensidade do exercício e taxa de aumento da atividade neuromuscular avaliada pela eletromiografia permite a estimativa do limiar de fadiga, que seria a intensidade que poderia ser mantida indefinidamente sem aumento dos sinais eletromiográficos ao longo do tempo. Levantou-se a hipótese de que a percepção subjetiva de esforço teria comportamento semelhante ao da ativação neuromuscular e que um limiar de esforço percebido (LEP), identificado de forma semelhante ao limiar de fadiga eletromiográfica, poderia coincidir com a velocidade crítica (VCrit). Treze indivíduos de ambos os sexos (23,0 ± 2,5 anos), em uma piscina de 15m de extensão e 2,5m de profundidade, realizaram três testes exaustivos de corrida aquática para determinação dos parâmetros do modelo de velocidade crítica, reportando o esforço percebido (escala de Borg de 6-20 pontos), a cada 15m. Para identificação do LEP, os coeficientes de inclinação das retas do aumento do esforço percebido no tempo (ordenada) e velocidades utilizadas (abscissa) foram ajustados a uma função linear que fornecia um ponto no eixo da velocidade onde, teoricamente, o esforço percebido seria estável indefinidamente. A VCrit foi estimada pelas equações usadas no modelo de velocidade crítica. Para comparação das estimativas de VCrit e do LEP, e de suas associações, foi feita ANOVA para medidas repetidas (p < 0,05) e calculada a correlação de Pearson. Os dados obtidos para a determinação da VCrit atenderam aos critérios adotados para a validade do modelo; a VCrit e o LEP não apresentaram diferença estatística (0,23 ± 0,02m/s x 0,24 ± 0,03m/s) e foram significativamente correlacionados (r = 0,85). Esses resultados sugerem que o LEP parece representar a intensidade máxima de exercício em que variáveis fisiológicas e psicofísicas encontrariam estabilidade, e que esse índice pode ser utilizado na determinação da VCrit.
Resumo:
Objective. To use the Pediatric Rheumatology International Trials Organization (PRINTO) core set of outcome measures to develop a validated definition of improvement for the evaluation of response to therapy in juvenile systemic lupus erythematosus (SLE).Methods. Thirty-seven experienced pediatric rheumatologists from 27 countries, each of whom had specific experience in the assessment of juvenile SLE patients, achieved consensus on 128 patient profiles as being clinically improved or not improved. Using the physicians' consensus ratings as the gold standard measure, the chi-square, sensitivity, specificity, false-positive and false-negative rates, area under the receiver operating characteristic curve, and kappa level of agreement for 597 candidate definitions of improvement were calculated. Only definitions with a kappa value greater than 0.7 were retained. The top definitions were selected based on the product of the content validity score multiplied by its kappa statistic.Results. The definition of improvement with the highest final score was at least 50% improvement from baseline in any 2 of the 5 core set measures, with no more than 1 of the remaining worsening by more than 30%.Conclusion. PRINTO proposes a valid and reproducible definition of improvement that reflects well the consensus rating of experienced clinicians and that incorporates clinically meaningful change in core set measures in a composite end point for the evaluation of global response to therapy in patients with juvenile SLE. The definition is now proposed for use in juvenile SLE clinical trials and may help physicians to decide whether a child with SLE responded adequately to therapy.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The perceived exertion has been a target of several investigations, many times with association with objective physiological indicators in exercise. Recently, the identification of the perceived exertion threshold (PET) was proposed in the water running, which presented no difference in relation to the critical velocity. Theoretically, both parameters would be indicators of the maximum steady state of variables such as V̇O2 and blood lactate. The objective of this work was to verify the coincidence between PET, critical power (PCrit) and an indicator of maximum V̇O2 steady state (PCrit') in cycle ergometer. Eight male participants were submitted to progressive effort test in order to determine V̇O2peak (46.7 ± 8.5 ml/kg/min) and to four rectangular tests until exhaustion for the estimation of the critical power model parameters, PET and PCrit'. The hyperbolic relation between mechanical power and time spent for the V̇O2peak to be reached in each test was used for the PCrit' estimation, considered as the asymptote in the power axis, and the portion of the anaerobic work capacity (CTAnaer) depleted up to the establishment of the V̇O2peak (CTAnaer'). In order to identify PET, the straight lines angular coefficients of the perceived exertion in time (ordinate) and the powers used (abscissa) were adjusted to a linear function that provided a point in the power axis in which the perceived exertion would be kept indefinitely stable. The parameters PCrit and CTAnaer were estimated by means of the power-time non-linear equation. In order to compare the estimations of PET, PCrit and PCrit', the analysis of variance ANOVA for repeated measurements was employed, and the associations were established through the Pearson correlation. CTAnaer and CTAnaer' were compared through the t test. PET (180 W ± 61 W), PCrit (174 W ± 43 W) and PCrit' (176 W ± 48 W) were not significantly different and the correlations were of 0.92-0.98. CTAnaer' (14,080 ± 5,219 J) was lower than CTAnaer (22,093 ± 9,042 J). One concludes that the PET predicts the intensity of PCrit and PCrit' with accuracy.
Resumo:
In this paper it is proposed a novel hybrid three-phase rectifier capable to achieve high input power factor (PF), and low total harmonic distortion in the input currents (THDI). The proposed hybrid high power rectifier is composed by a standard three-phase 6-pulses diode rectifier (Graetz bridge) with a parallel connection of single-phase Boost rectifiers in each three-phase rectifier leg. Such topology results in a structure capable of programming the input current waveform and providing conditions for obtaining high input power factor and low harmonic current distortion. In order to validate the proposed hybrid rectifier, this paper describes its principles of operation, with detailed experimental results and discussions on power rating of the required Boost converters as related to the desired total harmonic current distortion. It is demonstrated that only a fraction of the output power is processed through the Boost converters, making the proposed solution economically viable for very high power installations, with fast pay back of the investment. Moreover, retrofitting to existing installations is also feasible since the parallel path can be easily controlled by integration with the existing de-link. A prototype rated at 6 kW has been implemented in laboratory and fully demonstrated its operation, performance and feasibility to high power applications. © 2005 IEEE.
Resumo:
This work presents a study regarding the optimization of multipulse converters. A general expression for the connection (Δ or Y) for both 12 and 18-pulses is obtained and describes the output voltages on the secondary windings, depending on the voltage reference from the primary. These generalized expressions allows choosing different ratios between input and output voltages and as result an optimum operation point for the converter can be calculated. Considering Δ-connected converters the optimum point occurs when the magnetic core of the autotransformer processes 18% and 17% of the output power for 12 and 18-pulses, respectively. For Y-connected converters the optimum point occurs when the kVA rating is 13% and 18% for 12 and 18-pulses, respectively. Based on these results magnetic elements can be calculated and designed leading to a great weight and volume reduction and also to lower costs and losses. Finally an analysis is made to improve the kVA rating of the transformers for 12 and 18 pulses converters. © 2009 IEEE.
Resumo:
This paper presents the development and the experimental analysis of a new single-phase hybrid rectifier structure with high power factor (PF) and low harmonic distortion of current (THDI), suitable for application in traction systems of electrical vehicles pulled by electrical motors (trolleybus), which are powered by urban distribution network. This front-end rectifier structure is capable of providing significant improvements in trolleybuses systems and in the urban distribution network costs, and efficiency. The proposed structure is composed by an ordinary single-phase diode rectifier with parallel connection of a switched converter. It is outlined that the switched converter is capable of composing the input line current waveform assuring high power factor (HPF) and low THDI, as well as ordinary front-end converter. However, the power rating of the switched converter is about 34% of the total output power, assuring robustness and reliability. Therefore, the proposed structure was named single-phase HPF hybrid rectifier. A prototype rated at 15kW was developed and analyzed in laboratory. It was found that the input line current harmonic spectrum is in accordance with the harmonic limits imposed by IEC61000-3-4. The principle of operation, the mathematical analysis, the PWM control strategy, and experimental results are also presented in this paper. © 2009 IEEE.
Resumo:
Although dynamic and stretching exercises have been widely investigated, there is little information about warm up performed by tag games. Thus, the purpose of the present study was to verify the acute effect of dynamic exercises compared to a tag game warm up on agility and vertical jump in children. 25 boys and 24 girls participated in this study and performed the agility and vertical jump tests after warm up based on dynamic exercises or as a tag game lasting 10 min each in two different days randomly. Dynamic exercises warm up consisted in a run lasting 2.5 min followed by 2 series of 8 dynamic exercises lasting 10 seconds each interspersed with 20s of light run to recovery. Tag game warm up was performed by a tag game with two variations lasting 5 min each. The first variation there was a single cather, which aimed to get the other participants by touching hands. In the second part of the game, the rules were the same except that the participant that was caught had to help the catcher forming a team of catchers. Warm up intensity was monitored by OMNI perceived exertion scale. ANOVA 2x2 for repeated measures (Warm up x Sex) demonstrated no significant differences between dynamic exercises and tag game for agility and vertical jump (P>0.05) for boys and girls. Perceived exertion was significantly higher in tag game compared to dynamic exercises on girls (P<0.05). Both warm up models showed similar acute effects on agility and vertical jump in children. © Faculty of Education. University of Alicante.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose. - The purposes of this study were: i) to compare the physiological responses measured during a specific table tennis incremental test with the physiological responses measured during cycling, arm cranking, and treadmill running tests; and ii) to verify the accuracy of table tennis performance prediction based on the physiological responses from these tests.Methods. - Eleven national level male table tennis players participated in the study and undertook incremental tests using ergometers. Table tennis performance was defined as the ranking obtained during a simulated tournament between the participants.Results. - In general, peak values for physiological variables (e.g., (V) over dotO(2PEAK) and [La]PEAK) were significantly lower (P < 0.05) in the specific test (e.g., (V) over dotO(2PEAK) = 39.9 +/- 1.5 ml.kg(-1) per minute and [La]PEAK = 6.4 +/- 0.5 mmol.L-1) than during cycling (e.g., (V) over dotO(2PEAK) = 41.3 +/- 1.4 ml.kg(-1) per minute and [La]PEAK = 10.2 +/- 0.7 mmol.L-1) or running (e.g., (V) over dotO(2PEAK) = 43.9 +/- 1.5 ml.kg(-1) per minute and [La]PEAK = 10.0 +/- 0.7 mmol.L-1), but higher than during arm cranking (e.g., (V) over dotO(2PEAK) = 26.6 +/- 1.6 ml.kg(-1) per minute and [La]PEAK = 8.9 +/- 0.6 mmol.L-1). At respiratory compensation point intensity (RCP), only the variables measured on arm cranking were lower (P < 0.05) than on the other ergometers. Stepwise multiple regression analysis showed significant correlation between table tennis performance and lactate concentration ([La]) and also rate of perceived effort (RPE) at RCP during cycling (r = 0.89; P < 0.05).Conclusion. - In conclusion, the significant differences obtained between the specific and laboratory ergometers demonstrate the need to use a specific test to measure physiological parameters in table tennis and the physiological parameters measured, independent of the ergometer used, are unable to predict table tennis performance. (C) 2013 Elsevier Masson SAS. All rights reserved.