358 resultados para radionuclide
Resumo:
To get a better insight into the radiological features of industrial by-products that can be reused in building materials a review of the reported scientific data can be very useful. The current study is based on the continuously growing database of the By-BM (H2020-MSCA-IF-2015) project (By-products for Building Materials). Currently, the By-BM database contains individual data of about 431 by-products and 1095 building and raw materials. It was found that in case of the building materials the natural radionuclide content varied widely (Ra-226: <DL-27851 Bq/kg; Th-232: <DL-906 Bq/kg, K-40: <DL-17922 Bq/kg), more so than for the by-products (Ra-226: 7-3152 Bq/kg; Th-232: <DL-1350 Bq/kg, K-40: <DL-3001 Bq/kg). The average Ra-226, Th-232 and K-40 contents of the reported by-products were respectively 2.52, 2.35 and 0.39 times higher than the building materials. The gamma exposure of bulk building products was calculated according to IAEA Specific Safety Guide No. SSG-32 and the European Commission Radiation Protection 112 based I-index (EU BSS). It was found that in most cases the I-index without density consideration provides a significant overestimation in excess effective dose.
Resumo:
To evaluate the effect of sildenafil, administered prior to renal ischemia/reperfusion (I/R), by scintigraphy and histopathological evaluation in rats. Methods: Twenty-four rats were divided randomly into two groups. They received 0.1 ml of 99mTechnetium-etilenodicisteine intravenous, and a baseline (initial) renal scintigraphy was performed. The rats underwent 60 minutes of ischemia by left renal artery clamping. The right kidney was not manipulated. The sildenafil group (n=12) received orally 1 mg/kg of sildenafil suspension 60 minutes before ischemia. Treatment with saline 0.9% in the control group (n=12). Half of the rats was assessed after 24 hours and half after seven days I/R, with new renal scintigraphy to study differential function. After euthanasia, kidneys were removed and subjected to histopathological examination. For statistical evaluation, Student t and Mann-Whitney tests were used. Results: In the control group rats, the left kidneys had significant functional deficit, seven days after I/R, whose scintigraphic pattern was consistent with acute tubular necrosis, compared with the initial scintigraphy (p<0.05). Sildenafil treatment resulted in better differential function of the left kidneys 24h after reperfusion, compared with controls. Histopathologically, the left kidney of control rats (24 hours after I/R) showed a higher degree of cellular necrosis when compared with the sildenafil treated rats (p<0.05). Conclusion: Sildenafil had a protective effect in rat kidneys subjected to normothermic I/R, demonstrated by scintigraphy and histomorphometry
Resumo:
Mestrado em Medicina Nuclear - Área de especialização: Radiofarmácia
Resumo:
To evaluate the effect of sildenafil, administered prior to renal ischemia/reperfusion (I/R), by scintigraphy and histopathological evaluation in rats. Methods: Twenty-four rats were divided randomly into two groups. They received 0.1 ml of 99mTechnetium-etilenodicisteine intravenous, and a baseline (initial) renal scintigraphy was performed. The rats underwent 60 minutes of ischemia by left renal artery clamping. The right kidney was not manipulated. The sildenafil group (n=12) received orally 1 mg/kg of sildenafil suspension 60 minutes before ischemia. Treatment with saline 0.9% in the control group (n=12). Half of the rats was assessed after 24 hours and half after seven days I/R, with new renal scintigraphy to study differential function. After euthanasia, kidneys were removed and subjected to histopathological examination. For statistical evaluation, Student t and Mann-Whitney tests were used. Results: In the control group rats, the left kidneys had significant functional deficit, seven days after I/R, whose scintigraphic pattern was consistent with acute tubular necrosis, compared with the initial scintigraphy (p<0.05). Sildenafil treatment resulted in better differential function of the left kidneys 24h after reperfusion, compared with controls. Histopathologically, the left kidney of control rats (24 hours after I/R) showed a higher degree of cellular necrosis when compared with the sildenafil treated rats (p<0.05). Conclusion: Sildenafil had a protective effect in rat kidneys subjected to normothermic I/R, demonstrated by scintigraphy and histomorphometry
Resumo:
Estrogens can be labeled with the positron-emitting radionuclide fluorine-18 (t$\sb{1/2}$ = 110 min) by fluoride ion (n-Bu$\sb4$N$\sp{18}$F) displacement of a 16$\beta$-trifluoromethanesulfonate (triflate) derivative of the corresponding estrone 3-triflate, and purification by HPLC. That sequence has been used to synthesize the 11$\beta$-methoxy 1 and 11$\beta$-ethyl 2 analogues of the breast tumor imaging agent, 16$\alpha$-($\sp{18}$F) fluoro-17$\beta$-estradiol (FES). Tissue distribution studies of 1 and 2 in immature female rats show high selectivity for target tissue (T, uterus) vs non-target (NT, muscle and lung), with T/NT ratios being 43 and 17 at one hour after injection for 1 and 2, respectively. The parent estrogen FES has previously been shown to display an intermediate value for tissue selectivity.
Resumo:
The contamination of Japan after the Fukushima accident has been investigated mainly for volatile fission products, but only sparsely for actinides such as plutonium. Only small releases of actinides were estimated in Fukushima. Plutonium is still omnipresent in the environment from previous atmospheric nuclear weapons tests. We investigated soil and plants sampled at different hot spots in Japan, searching for reactor-borne plutonium using its isotopic ratio Pu-240/Pu-239. By using accelerator mass spectrometry, we clearly demonstrated the release of Pu from the Fukushima Daiichi power plant: While most samples contained only the radionuclide signature of fallout plutonium, there is at least one vegetation sample whose isotope ratio (0.381 +/- 0.046) evidences that the Pu originates from a nuclear reactor (Pu239+240 activity concentration 0.49 Bq/kg). Plutonium content and isotope ratios differ considerably even for very close sampling locations, e.g. the soil and the plants growing on it. This strong localization indicates a particulate Pu release, which is of high radiological risk if incorporated.
Resumo:
Harnessing the power of nuclear reactions has brought huge benefits in terms of nuclear energy, medicine and defence as well as risks including the management of nuclear wastes. One of the main issues for radioactive waste management is liquid radioactive waste (LRW). Different methods have been applied to remediate LRW, thereunder ion exchange and adsorption. Comparative studies have demonstrated that Na2Ti2O3SiO4·2H2O titanosilicate sorption materials are the most promising in terms of Cs+ and Sr2+ retention from LRW. Therefore these TiSi materials became the object of this study. The recently developed in Ukraine sol-gel method of synthesizing these materials was chosen among the other reported approaches since it allows obtaining the TiSi materials in the form of particles with size ≥ 4mm. utilizing inexpensive and bulk stable inorganic precursors and yielded the materials with desirable properties by alteration of the comparatively mild synthesis conditions. The main aim of this study was to investigate the physico-chemical properties of sol-gel synthesized titanosilicates for radionuclide uptake from aqueous solutions. The effect of synthesis conditions on the structural and sorption parameters of TiSi xerogels was planned to determine in order to obtain a highly efficient sorption material. The ability of the obtained TiSis to retain Cs+, Sr2+ and other potentially toxic metal cations from the synthetic and real aqueous solutions was intended to assess. To our expectations, abovementioned studies will illustrate the efficiency and profitability of the chosen synthesis approach, synthesis conditions and the obtained materials. X-ray diffraction, low temperature adsorption/desorption surface area analysis, X-ray photoelectron spectroscopy, infrared spectroscopy and scanning electron microscopy with energy dispersive X-ray spectroscopy was used for xerogels characterization. The sorption capability of the synthesized TiSi gels was studied as a function of pH, adsorbent mass, initial concentration of target ion, contact time, temperature, composition and concentration of the background solution. It was found that the applied sol-gel approach yielded materials with a poorly crystalline sodium titanosilicate structure under relatively mild synthesis conditions. The temperature of HTT has the strongest influence on the structure of the materials and consequently was concluded to be the control factor for the preparation of gels with the desired properties. The obtained materials proved to be effective and selective for both Sr2+ and Cs+ decontamination from synthetic and real aqueous solutions like drinking, ground, sea and mine waters, blood plasma and liquid radioactive wastes.
Resumo:
Important historical informations on the temporal changes of anthropogenic pollution in marine environment can be assessed using sediment analysis. Dating is a crucial prerequisite to reconstruct pollution events, to calculate fluxes, and thus to allow comparison between different sites. This work presents estimates of accumulation rates of sediments in the Bay of Biscay. Fives cores were collected during RIKEAU 2002 cruise on board o/v Thalia in order to study temporal changes in PAH and organohalogens compounds content of sediment. We compare chronostratigraphic estimates on cores derived from the natural radionuclide 210Pb in excess with estimates from the known times of introduction of the artificial radionuclide 137Cs to the environment. 210Pb, 226Ra and 137Cs were measured directly by non-destructive gamma spectrometry using a well type γ-detector. Total 210Pb and 226Ra activities vary from 30 to 150 mBq g-1, and 20 to 36 mBq g-1 respectively; 137Cs presents lower levels (< 5 mBq g-1). Profiles of 210Pb in three cores present a well mixed layer, from 2-3 to 10 cm, in the uppermost sediments, followed by an exponential decrease of activities, suitable for the determination of sedimentation rates. Under constant flux and sedimentation rate assumptions, vertical accretion rates derived from 210Pb present a large range from nearly 0.1 cm yr-1 up to almost 0.3 cm yr-1. Differences are mainly due to relative position of studied cores regarding the muddy patch. Although the moderate level of 137Cs limits the accuracy of this dating method, profiles of 137Cs with depth strengthen mean rates derived from 210Pb data. The implication of this dating on pollutant inputs in sediments of the Bay of Biscay is briefly discussed.
Resumo:
Presence and concentrations of radionuclides could be as a result of natural and human activities. This study examined the associations and differences among soil, sediment and water specific activities of long-lived radioactive element (LLRE). Gamma spectroscopy was used to measure the concentration of the LLRE along the Mini Okoro/Oginigba Creek, Port Harcourt. Specific activities of three selected LLRE were derived. Correlation analysis was carried out to examine associations among the specific activities across different substrates. A strong and a significant negative correlation exists between the specific activities of Water 40K and Soil 232Th (r =-0.721, p<0.05); Water 238U and Soil 238U (r = -0.717, p<0.05) and Water 40K and Sediment 238U (r=-0.69, p<0.05). Comparison using Mann-Whitney U test shows that, soil and sediment are similar in their specific activities with Z values of -0.408, -1.209 and -1.021 (p > 0.05) for 40K, 232Th and 238U respectively. The concentration of solid samples (soil and sediment) is different from the liquid (water) samples. These associations can be attributed to some specific underlying factors. And in other to understand them there is need for more studies.
Resumo:
The common use of phosphate fertilizers NPK and amendments in sugar cane crops in Brazilian agriculture may increase the Ra-226, Th-232 and K-40 activity concentrations in soils and their availability for plants and human food chain. Thus, the main aim of this study was to evaluate the distribution of Ra-226, Th-232 and K-40 in soils and sugar cane crops in the Corumbatai river basin, São Paulo State, Brazil. The gamma spectrometry was utilized to measure the Ra-226, Th-232 and K-40 activity concentration in all samples. The soil-to-sugar cane transfer factors (TF) were quantified using the ratio between the radionuclide activity concentration in sugar cane and its activity concentration in soil. The results show that, although radionuclides incorporated in phosphate fertilizers and amendments are annually added in the sugar cane crops, if utilized in accordance with the recommended rates, their use does not lead to hazards levels in soils. The soil-to-sugar cane transfer of radionuclides occurred in the following order K-40 > Ra-226 > Th-232. Therefore, under these conditions, radionuclides intake through consumption of sugar is not hazardous to human health. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
La fraction d’éjection du ventricule gauche est un excellent marqueur de la fonction cardiaque. Plusieurs techniques invasives ou non sont utilisées pour son calcul : l’angiographie, l’échocardiographie, la résonnance magnétique nucléaire cardiaque, le scanner cardiaque, la ventriculographie radioisotopique et l’étude de perfusion myocardique en médecine nucléaire. Plus de 40 ans de publications scientifiques encensent la ventriculographie radioisotopique pour sa rapidité d’exécution, sa disponibilité, son faible coût et sa reproductibilité intra-observateur et inter-observateur. La fraction d’éjection du ventricule gauche a été calculée chez 47 patients à deux reprises, par deux technologues, sur deux acquisitions distinctes selon trois méthodes : manuelle, automatique et semi-automatique. Les méthodes automatique et semi-automatique montrent dans l’ensemble une meilleure reproductibilité, une plus petite erreur standard de mesure et une plus petite différence minimale détectable. La méthode manuelle quant à elle fournit un résultat systématiquement et significativement inférieur aux deux autres méthodes. C’est la seule technique qui a montré une différence significative lors de l’analyse intra-observateur. Son erreur standard de mesure est de 40 à 50 % plus importante qu’avec les autres techniques, tout comme l’est sa différence minimale détectable. Bien que les trois méthodes soient d’excellentes techniques reproductibles pour l’évaluation de la fraction d’éjection du ventricule gauche, les estimations de la fiabilité des méthodes automatique et semi-automatique sont supérieures à celles de la méthode manuelle.
Resumo:
Il presente lavoro di tesi nasce in seguito all’esperienza di tirocinio svolta presso l’Arcispedale Santa Maria Nuova di Reggio Emilia. Fulcro di questo lavoro è lo sviluppo di un sistema di pianificazione della dose per il trattamento dei pazienti sottoposti a Molecular Radionuclide Therapy (MRT). Presso tale struttura ospedaliera è già stato sviluppato uno strumento che si appoggia all’ambiente di lavoro Matlab per il calcolo dosimetrico. Tale programma è chiamato VoxelMed. Si tratta di uno strumento di calcolo che lavora al così detto voxel-level, tecnica di sviluppo recente che permette il calcolo della dose assorbita all’interno di un paziente in modo più dettagliato rispetto ai metodi di calcolo basati unicamente sulla stima media per organo, tipicamente impiegati in dosimetria tradizionale. Parte del lavoro di tesi consiste nell’implementare nuove modalità di calcolo ed aggiungere ulteriori accorgimenti all’attuale versione di VoxelMed. In VoxelMed è stata poi integrata ex-novo una componente di calcolo di misure radiobiologiche, in particolare della BED. La dose assorbita non è infatti un parametro sufficiente per valutare gli effetti della radiazione sui tessuti, a parità di tipo ed energia della radiazione gli effetti possono essere molto variabili. La BED è il parametro che tiene conto della risposta del tessuto sano o cancerogeno alla radiazione. Parte del lavoro è stato svolto sperimentalmente, tramite misure con fantocci acquisiti o preparati ad hoc. In particolare si sono utilizzati diverse tipologie di fantocci, per effettuare protocolli di calibrazione dei sistemi di acquisizione, misure di curve di effetto di volume parziale e test finali di verifica. Per un ulteriore verifica delle prestazioni di calcolo si sono effettuate misurazioni su un gruppo di pazienti e si sono confrontati i risultati con quelli ottenuti dal software maggiormente utilizzato nella pratica clinica, OLINDA/EXM.
Resumo:
La fraction d’éjection du ventricule gauche est un excellent marqueur de la fonction cardiaque. Plusieurs techniques invasives ou non sont utilisées pour son calcul : l’angiographie, l’échocardiographie, la résonnance magnétique nucléaire cardiaque, le scanner cardiaque, la ventriculographie radioisotopique et l’étude de perfusion myocardique en médecine nucléaire. Plus de 40 ans de publications scientifiques encensent la ventriculographie radioisotopique pour sa rapidité d’exécution, sa disponibilité, son faible coût et sa reproductibilité intra-observateur et inter-observateur. La fraction d’éjection du ventricule gauche a été calculée chez 47 patients à deux reprises, par deux technologues, sur deux acquisitions distinctes selon trois méthodes : manuelle, automatique et semi-automatique. Les méthodes automatique et semi-automatique montrent dans l’ensemble une meilleure reproductibilité, une plus petite erreur standard de mesure et une plus petite différence minimale détectable. La méthode manuelle quant à elle fournit un résultat systématiquement et significativement inférieur aux deux autres méthodes. C’est la seule technique qui a montré une différence significative lors de l’analyse intra-observateur. Son erreur standard de mesure est de 40 à 50 % plus importante qu’avec les autres techniques, tout comme l’est sa différence minimale détectable. Bien que les trois méthodes soient d’excellentes techniques reproductibles pour l’évaluation de la fraction d’éjection du ventricule gauche, les estimations de la fiabilité des méthodes automatique et semi-automatique sont supérieures à celles de la méthode manuelle.