950 resultados para portable instruments


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Due to the increasing importance of quality of life assessments in chronic obstructive pulmonary disease (COPD) patients, and the increased use of the International Classification of Functioning, Disability and Health (ICF) for comparative purposes it is essential to understand the relationship between health-related quality of life (HRQL) instruments and the ICF. OBJECTIVE: The objective of this study was to compare the content of recommended COPD-specific HRQL instruments using the ICF as reference. COPD-specific instruments mentioned in widely accepted guidelines were linked to the ICF using standardized linking rules. The degree of agreement between various health professionals was assessed by calculating the kappa statistic. RESULTS: Eleven instruments were included. They varied strongly in the number of concepts contained and the number of ICF categories used to map these concepts. A total of 548 concepts were identified and linked to 60 different ICF categories. Only the single category 'dyspnea' was covered by all instruments, whilst 21 categories were unique to specific instruments. The relationships of the measures with the ICF were identified. CONCLUSIONS: This study may aid researchers and clinicians to choose the most appropriate instrument for a specific purpose as well as help compare studies that have used different instruments for HRQL assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare central retinal thickness (CRT) measurements in healthy eyes by different commercially available OCT instruments and to compare the intersession reproducibility of such measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The widespread of low cost embedded electronics makes it easier to implement the smart devices that can understand either the environment or the user behaviors. The main object of this project is to design and implement home use portable smart electronics, including the portable monitoring device for home and office security and the portable 3D mouse for convenient use. Both devices in this project use the MPU6050 which contains a 3 axis accelerometer and a 3 axis gyroscope to sense the inertial motion of the door or the human hands movement. For the portable monitoring device for home and office security, MPU6050 is used to sense the door (either home front door or cabinet door) movement through the gyroscope, and Raspberry Pi is then used to process the data it receives from MPU6050, if the data value exceeds the preset threshold, Raspberry Pi would control the USB Webcam to take a picture and then send out an alert email with the picture to the user. The advantage of this device is that it is a small size portable stand-alone device with its own power source, it is easy to implement, really cheap for residential use, and energy efficient with instantaneous alert. For the 3D mouse, the MPU6050 would use both the accelerometer and gyroscope to sense user hands movement, the data are processed by MSP430G2553 through a digital smooth filter and a complementary filter, and then the filtered data will pass to the personal computer through the serial COM port. By applying the cursor movement equation in the PC driver, this device can work great as a mouse with acceptable accuracy. Compared to the normal optical mouse we are using, this mouse does not need any working surface, with the use of the smooth and complementary filter, it has certain accuracy for normal use, and it is easy to be extended to a portable mouse as small as a finger ring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Due to the increasing importance of quality of life assessments in obstructive sleep apnea (OSA) patients and due to an increased use of the International Classification of Functioning, Disability and Health (ICF), for comparative purposes it is essential to understand the relationship between health-related quality of life (HRQOL) instruments and the ICF. The purpose of this study was to compare the content covered by OSA-specific instruments using the ICF. PATIENTS AND METHODS: OSA-specific instruments were identified, including the Calgary Sleep Apnea Quality of Life Index, the Functional Outcomes of Sleep Questionnaire, the Obstructive Sleep Apnea Patient-Oriented Severity Index, and the Quebec Sleep Questionnaire, and linked to the ICF by six health professionals according to standardized guidelines. The degree of agreement between health professionals was calculated by means of the kappa statistic. RESULTS: A total of 308 concepts were identified and linked to 78 different ICF categories; 35 categories of the component body function, one category of the component body structure, 38 categories of the component activities and participation, and four categories of the component environmental factors. Only contents within the chapters mental functions, mobility and social life were addressed by all instruments. Forty-seven categories were covered by only one instrument. CONCLUSION: The ICF proved highly useful for the comparison of HRQOL instruments. This analysis may help researchers and clinicians to choose the most appropriate HRQOL instrument for a specific purpose as well as help to compare study outcomes of studies using different instruments for HRQOL assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wood burning for residential heating is prevalent in the Rocky Mountain regions of the United States. Studies have shown that wood stoves can be a significant source of PM2.5 within homes. In this study, the effectiveness of an electrostatic filter portable air purifier was evaluated (1) in a home where a wood stove was the sole heat source and (2) in a home where a wood stove was used as a supplemental heat source. Particle count concentrations in six particle sizes and particle mass concentrations in two particle sizes weremeasured for ten 12-hour purifier on and ten purifier off trials in each home. Particle count concentrations were reduced by 61–85 percent. Similar reductions were observed in particle mass concentrations. These findings, although limited to one season, suggest that a portable air purifier may effectively reduce indoor particulate matter concentrations associated with wood combustion during home heating.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low back pain (LBP) is currently the most prevalent and costly musculoskeletal problem in modern societies. Screening instruments for the identification of prognostic factors in LBP may help to identify patients with an unfavourable outcome. In this systematic review screening instruments published between 1970 and 2007 were identified by a literature search. Nine different instruments were analysed and their different items grouped into ten structures. Finally, the predictive effectiveness of these structures was examined for the dependent variables including "work status", "functional limitation", and "pain". The strongest predictors for "work status" were psychosocial and occupational structures, whereas for "functional limitation" and "pain" psychological structures were dominating. Psychological and occupational factors show a high reliability for the prognosis of patients with LBP. Screening instruments for the identification of prognostic factors in patients with LBP should include these factors as a minimum core set.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

What characterizes micropollution as a policy problem and which policy instruments are adequate to regulate micropollution, given the specific problem features? In this article, problem characteristics of micropollution are systematically analyzed and linked to potential policy solutions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rumination und Suppression sind 2 maladaptive Emotionsregulationsstrategien, die im Zusammenhang mit pathologischem Verhalten wie übermäßigem Essen oder Trinken stehen. Ein Messinstrument, welches beide Strategien in Kurzform erfasst, fehlt bisher. Der RS-8 erfasst mit 8 Items die beiden Dimensionen Rumination und Suppression. Anhand von 2 klinischen (Patienten mit Alkoholabhängigkeit [n = 79], Patienten mit Adipositas [n = 53]) und einer nichtklinischen Stichprobe (n = 133) wurde die psychometrische Qualität der Skala überprüft. Die Ergebnisse zeigen, dass der RS-8 ein valides und reliables Messinstrument ist. Die interne Konsistenz kann als gut und die faktorielle Validität als sehr gut bewertet werden. Der RS-8 ist ein ökonomisches Screening-Instrument, welches bei klinischen und nicht-klinischen Stichproben eingesetzt werden kann.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction As students become more connected with the internet and other current technologies, the school of nursing has continued to investigate more innovative, meaningful, and effective uses of technology. One particular technology whose use has increased is the portable music/video player. Like the cell phone, mp3 players and iPods have become a standard accessory for students. To capitalize on this popular technology the School has started several pilot projects involving podcasting under graduate and graduate nursing classes and has also been involved in one research project using video iPods. [See PDF for complete abstract]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Epidemiological studies show that elevated levels of particulate matter in ambient air are highly correlated with respiratory and cardiovascular diseases. Atmospheric particles originate from a large number of sources and have a highly complex and variable composition. An assessment of their potential health risks and the identification of the most toxic particle sources would require a large number of investigations. Due to ethical and economic reasons, it is desirable to reduce the number of in vivo studies and to develop suitable in vitro systems for the investigation of cell-particle interactions. METHODS We present the design of a new particle deposition chamber in which aerosol particles are deposited onto cell cultures out of a continuous air flow. The chamber allows for a simultaneous exposure of 12 cell cultures. RESULTS Physiological conditions within the deposition chamber can be sustained constantly at 36-37°C and 90-95% relative humidity. Particle deposition within the chamber and especially on the cell cultures was determined in detail, showing that during a deposition time of 2 hr 8.4% (24% relative standard deviation) of particles with a mean diameter of 50 nm [mass median diameter of 100 nm (geometric standard deviation 1.7)] are deposited on the cell cultures, which is equal to 24-34% of all charged particles. The average well-to-well variability of particles deposited simultaneously in the 12 cell cultures during an experiment is 15.6% (24.7% relative standard deviation). CONCLUSIONS This particle deposition chamber is a new in vitro system to investigate realistic cell-particle interactions at physiological conditions, minimizing stress on the cell cultures other than from deposited particles. A detailed knowledge of particle deposition characteristics on the cell cultures allows evaluating reliable dose-response relationships. The compact and portable design of the deposition chamber allows for measurements at any particle sources of interest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intensive Family Preservation Services seek to reflect the values of focusing on client strengths and viewing clients as colleagues. To promote those values, Intensive Family Preservation Programs should include a systematic form of client self monitoring in their packages of outcome measures. This paper presents a model of idiographic self-monitoring used in time series, single system research design developed for Family Partners, a family preservation program of the School for Contemporary Education in Annandale, Virginia. The evaluation model provides a means of empowering client families to utilize their strengths and promote their status as colleague in determining their own goals, participating in the change process, and measuring their own progress.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reliability of millimeter and sub-millimeter wave radiometer measurements is dependent on the accuracy of the loads they employ as calibration targets. In the recent past on-board calibration loads have been developed for a variety of satellite remote sensing instruments. Unfortunately some of these have suffered from calibration inaccuracies which had poor thermal performance of the calibration target as the root cause. Stringent performance parameters of the calibration target such as low reflectivity, high temperature uniformity, low mass and low power consumption combined with low volumetric requirements remain a challenge for the space instrument developer. In this paper we present a novel multi-layer absorber concept for a calibration load which offers an excellent compromise between very good radiometric performance and temperature uniformity and the mass and volumetric constraints required by space-borne calibration targets.