877 resultados para performance assessment
Resumo:
OBJECTIVE: Assessing the quality of life and the clinical and social-demographic factors associated in schizophrenic spectrum patients (ICD-10 F20-F29) attending CAPS at the programmatic area 3.0. METHODS: A cross-sectional study was carried out in a sample of schizophrenic spectrum patients who have been enrolled in 2008 in CAPS in programmatic area (AP) 3 at Rio de Janeiro city, using MINIPLUS to assess schizophrenia spectrum disorder and use of psychoactive substances, Positive and Negative Symptoms Scale (PANSS) to assess psychiatric symptoms and Quality of Life Scale (QLS-BR) to assess the quality of life. RESULTS: Seventy nine patients were included, of whom 74 (93.7%) presented some impairment in quality of life. The most frequently affected area was occupational performance. Variables that showed a significant association with severe impairment of quality of life were: marital status, race, occupation, who patients lived with, homelessness, having children, previous psychiatric hospitalization, negative symptoms and symptoms designated as not applicable (being characterized by a lack of typical positive and negative symptoms). CONCLUSION: The knowledge of these factors should be crucial to implement health policies and psychosocial rehabilitation programs focused on improving the quality of life of these patients.
Resumo:
Projeto de investigação integrado de International Master in Sustainable Built Environment
Resumo:
INTRODUCTION: Schizophrenia is a chronic mental disorder associated with impairment in social functioning. The most widely used scale to measure social functioning is the GAF (Global Assessment of Functioning), but it has the disadvantage of measuring at the same time symptoms and functioning, as described in its anchors. OBJECTIVES:Translation and cultural adaptation of the PSP, proposing a final version in Portuguese for use in Brazil. METHODS: We performed five steps: 1) translation; 2) back translation; 3) formal assessment of semantic equivalence; 4) debriefing; 5) analysis by experts. Interrater reliability (Intraclass correlation, ICC) between two raters was also measured. RESULTS: The final version was applied by two independent investigators in 18 adults with schizophrenia (DSM-IV-TR). The interrater reliability (ICC) was 0.812 (p < 0.001). CONCLUSION: The translation and adaptation of the PSP had an adequate level of semantic equivalence between the Portuguese version and the original English version. There were no difficulties related to understanding the content expressed in the translated texts and terms. Its application was easy and it showed a good interrater reliability. The PSP is a valid instrument for the measurement of personal and social functioning in schizophrenia.
Resumo:
"Tissue engineering: part A", vol. 21, suppl. 1 (2015)
Resumo:
The Symbol Digit Modalities Test (SDMT) is a widely used instrument to assess information processing speed, attention, visual scanning, and tracking. Considering that repeated evaluations are a common need in neuropsychological assessment routines, we explored test–retest reliability and practice effects of two alternate SDMT forms with a short inter-assessment interval. A total of 123 university students completed the written SDMT version in two different time points separated by a 150-min interval. Half of the participants accomplished the same form in both occasions, while the other half filled different forms. Overall, reasonable test–retest reliabilities were found (r = .70), and the subjects that completed the same form revealed significant practice effects (p < .001, dz = 1.61), which were almost non-existent in those filling different forms. These forms were found to be moderately reliable and to elicit a similar performance across participants, suggesting their utility in repeated cognitive assessments when brief inter-assessment intervals are required.
Resumo:
OBJECTIVE: To assess the hemodynamic and vasodilating effects of milrinone lactate (ML) in patients with dilated cardiomyopathy (DCM) and New York Heart Association (NYHA) class III and IV heart failure. METHODS: Twenty patients with DCM and NYHA class III and IV heart failure were studied. The hemodynamic and vasodilating effects of ML, administered intravenously, were evaluated. The following variables were compared before and during drug infusion: cardiac output (CO) and cardiac index (CI); pulmonary capillary wedge pressure (PCWP); mean aortic pressure (MAP); mean pulmonary artery pressure (MPAP); mean right atrial pressure (MRAP); left ventricular systolic and end-diastolic pressures (LVSP and LVEDP, respectively); peak rate of left ventricular pressure rise (dP/dt); systemic vascular resistance (SVR); pulmonary vascular resistance (PVR); and heart rate (HR). RESULTS: All patients showed a significant improvement of the analysed parameters of cardiac performance with an increase of CO and CI; a significant improvement in myocardial contractility (dP/dt) and reduction of the LVEDP; PCWP; PAP; MAP; MRAP; SVR; PVR. Were observed no significant increase in HR occurred. CONCLUSION: Milrinone lactate is an inotropic dilating drug that, when administered intravenously, has beneficial effects on cardiac performance and myocardial contractility. It also promotes reduction of SVR and PVR in patients with DCM and NYHA class III and IV of heart failure.
Resumo:
Background: The Neonatal Behavioral Assessment Scale (NBAS, Brazelton & Nugent, 1995) is an instrument conceived to observe the neonatal neurobehavior. Data analysis is usually performed by organizing items into groups. The most widely used data reduction for the NBAS was developed by Lester, Als, and Brazelton (1982). Objective: Examine the psychometric properties of the NBAS items in a sample of 213 Portuguese infants. Method: The NBAS was performed in the first week of infant life (3 days±2) and in the seventh week of life (52 days±5). Results: Principal component analyses yielded a solution of four components explaining 55.13% of total variance. Construct validity was supported by better neurobehavioral performance of 7-week-old infants compared with 1-week-old infants. Conclusion: Changes in the NBAS structure for the Portuguese sample are suggested compared to Lester factors in order to reach better internal consistency of the scale.
Resumo:
Abstract The assessment of left atrial (LA) function is used in various cardiovascular diseases. LA plays a complementary role in cardiac performance by modulating left ventricular (LV) function. Transthoracic two-dimensional (2D) phasic volumes and Doppler echocardiography can measure LA function non‑invasively. However, evaluation of LA deformation derived from 2D speckle tracking echocardiography (STE) is a new feasible and promising approach for assessment of LA mechanics. These parameters are able to detect subclinical LA dysfunction in different pathological condition. Normal ranges for LA deformation and cut-off values to diagnose LA dysfunction with different diseases have been reported, but data are still conflicting, probably because of some methodological and technical issues. This review highlights the importance of an unique standardized technique to assess the LA phasic functions by STE, and discusses recent studies on the most important clinical applications of this technique.
Resumo:
Background/Aims: Cognitive dysfunction after medical treatment is increasingly being recognized. Studies on this topic require repeated cognitive testing within a short time. However, with repeated testing, practice effects must be expected. We quantified practice effects in a demographically corrected summary score of a neuropsychological test battery repeatedly administered to healthy elderly volunteers. Methods: The Consortium to Establish a Registry for Alzheimer's Disease (CERAD) Neuropsychological Assessment Battery (for which a demographically corrected summary score was developed), phonemic fluency tests, and trail-making tests were administered in healthy volunteers aged 65 years or older on days 0, 7, and 90. This battery allows calculation of a demographically adjusted continuous summary score. Results: Significant practice effects were observed in the CERAD total score and in the word list (learning and recall) subtest. Based on these volunteer data, we developed a threshold for diagnosis of postoperative cognitive dysfunction (POCD) with the CERAD total score. Conclusion: Practice effects with repeated administration of neuropsychological tests must be accounted for in the interpretation of such tests. Ignoring practice effects may lead to an underestimation of POCD. The usefulness of the proposed demographically adjusted continuous score for cognitive function will have to be tested prospectively in patients.
Resumo:
Therapeutic drug monitoring (TDM) may contribute to optimizing the efficacy and safety of antifungal therapy because of the large variability in drug pharmacokinetics. Rapid, sensitive, and selective laboratory methods are needed for efficient TDM. Quantification of several antifungals in a single analytical run may best fulfill these requirements. We therefore developed a multiplex ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method requiring 100 μl of plasma for simultaneous quantification within 7 min of fluconazole, itraconazole, hydroxyitraconazole, posaconazole, voriconazole, voriconazole-N-oxide, caspofungin, and anidulafungin. Protein precipitation with acetonitrile was used in a single extraction procedure for eight analytes. After reverse-phase chromatographic separation, antifungals were quantified by electrospray ionization-triple-quadrupole mass spectrometry by selected reaction monitoring detection using the positive mode. Deuterated isotopic compounds of azole antifungals were used as internal standards. The method was validated based on FDA recommendations, including assessment of extraction yields, matrix effect variability (<9.2%), and analytical recovery (80.1 to 107%). The method is sensitive (lower limits of azole quantification, 0.01 to 0.1 μg/ml; those of echinocandin quantification, 0.06 to 0.1 μg/ml), accurate (intra- and interassay biases of -9.9 to +5% and -4.0 to +8.8%, respectively), and precise (intra- and interassay coefficients of variation of 1.2 to 11.1% and 1.2 to 8.9%, respectively) over clinical concentration ranges (upper limits of quantification, 5 to 50 μg/ml). Thus, we developed a simple, rapid, and robust multiplex UPLC-MS/MS assay for simultaneous quantification of plasma concentrations of six antifungals and two metabolites. This offers, by optimized and cost-effective lab resource utilization, an efficient tool for daily routine TDM aimed at maximizing the real-time efficacy and safety of different recommended single-drug antifungal regimens and combination salvage therapies, as well as a tool for clinical research.
Resumo:
Fall prevention in elderly subjects is often based on training and rehabilitation programs that include mostly traditional balance and strength exercises. By applying such conventional interventions to improve gait performance and decrease fall risk, some important factors are neglected such as the dynamics of the gait and the motor learning processes. The EU project "Self Mobility Improvement in the eLderly by counteractING falls" (SMILING project) aimed to improve age-related gait and balance performance by using unpredicted external perturbations during walking through motorized shoes that change insole inclination at each stance. This paper describes the shoe-worn inertial module and the gait analysis method needed to control in real-time the shoe insole inclination during training, as well as gait spatio-temporal parameters obtained during long distance walking before and after the 8-week training program that assessed the efficacy of training with these motorized shoes.
Resumo:
In this paper I review a series of theoretical concepts that are relevant for the integrated assessment of agricultural sustainability but that are not generally included in the curriculum of the various scientific disciplines dealing with quantitative analysis of agriculture. I first illustrate with plain narratives and concrete examples that sustainability is an extremely complex issue requiring the simultaneous consideration of several aspects, which cannot be reduced into a single indicator of performance. Following, I justify this obvious need for multi-criteria analysis with theoretical concepts dealing with the epistemological predicament of complexity, starting from classic philosophical lessons to arrive to recent developments in complex system theory, in particular Rosen´s theory of modelling relation which is essential to analyze the quality of any quantitative representation. The implications of these theoretical concepts are then illustrated with applications of multi-criteria analysis to the sustainability of agriculture. I wrap up by pointing out the crucial difference between "integrated assessment" and "integrated analysis". An integrated analysis is a set of indicators and analytical models generating an analytical output. An integrated assessment is much more than that. It is about finding an effective way to deal with three key issues: (i) legitimacy – how to handle the unavoidable existence of legitimate but contrasting points of view about different meanings given by social actors to the word "development"; (ii) pertinence – how to handle in a coherent way scientific analyses referring to different scales and dimensions; and (iii) credibility – how to handle the unavoidable existence of uncertainty and genuine ignorance, when dealing with the analysis of future scenarios.
Resumo:
This study describes the validation of a new wearable system for assessment of 3D spatial parameters of gait. The new method is based on the detection of temporal parameters, coupled to optimized fusion and de-drifted integration of inertial signals. Composed of two wirelesses inertial modules attached on feet, the system provides stride length, stride velocity, foot clearance, and turning angle parameters at each gait cycle, based on the computation of 3D foot kinematics. Accuracy and precision of the proposed system were compared to an optical motion capture system as reference. Its repeatability across measurements (test-retest reliability) was also evaluated. Measurements were performed in 10 young (mean age 26.1±2.8 years) and 10 elderly volunteers (mean age 71.6±4.6 years) who were asked to perform U-shaped and 8-shaped walking trials, and then a 6-min walking test (6MWT). A total of 974 gait cycles were used to compare gait parameters with the reference system. Mean accuracy±precision was 1.5±6.8cm for stride length, 1.4±5.6cm/s for stride velocity, 1.9±2.0cm for foot clearance, and 1.6±6.1° for turning angle. Difference in gait performance was observed between young and elderly volunteers during the 6MWT particularly in foot clearance. The proposed method allows to analyze various aspects of gait, including turns, gait initiation and termination, or inter-cycle variability. The system is lightweight, easy to wear and use, and suitable for clinical application requiring objective evaluation of gait outside of the lab environment.
Resumo:
Meta-analysis of prospective studies shows that quantitative ultrasound of the heel using validated devices predicts risk of different types of fracture with similar performance across different devices and in elderly men and women. These predictions are independent of the risk estimates from hip DXA measures.Introduction Clinical utilisation of heel quantitative ultrasound (QUS) depends on its power to predict clinical fractures. This is particularly important in settings that have no access to DXA-derived bone density measurements. We aimed to assess the predictive power of heel QUS for fractures using a meta-analysis approach.Methods We conducted an inverse variance random effects meta-analysis of prospective studies with heel QUS measures at baseline and fracture outcomes in their follow-up. Relative risks (RR) per standard deviation (SD) of different QUS parameters (broadband ultrasound attenuation [BUA], speed of sound [SOS], stiffness index [SI], and quantitative ultrasound index [QUI]) for various fracture outcomes (hip, vertebral, any clinical, any osteoporotic and major osteoporotic fractures) were reported based on study questions.Results Twenty-one studies including 55,164 women and 13,742 men were included in the meta-analysis with a total follow-up of 279,124 person-years. All four QUS parameters were associated with risk of different fracture. For instance, RR of hip fracture for 1 SD decrease of BUA was 1.69 (95% CI 1.43-2.00), SOS was 1.96 (95% CI 1.64-2.34), SI was 2.26 (95%CI 1.71-2.99) and QUI was 1.99 (95% CI 1.49-2.67). There was marked heterogeneity among studies on hip and any clinical fractures but no evidence of publication bias amongst them. Validated devices from different manufacturers predicted fracture risks with similar performance (meta-regression p values > 0.05 for difference of devices). QUS measures predicted fracture with a similar performance in men and women. Meta-analysis of studies with QUS measures adjusted for hip BMD showed a significant and independent association with fracture risk (RR/SD for BUA = 1.34 [95%CI 1.22-1.49]).Conclusions This study confirms that heel QUS, using validated devices, predicts risk of different fracture outcomes in elderly men and women. Further research is needed for more widespread utilisation of the heel QUS in clinical settings across the world.