931 resultados para peak symmetry
Resumo:
We analyze the production of defects during the dynamical crossing of a mean-field phase transition with a real order parameter. When the parameter that brings the system across the critical point changes in time according to a power-law schedule, we recover the predictions dictated by the well-known Kibble-Zurek theory. For a fixed duration of the evolution, we show that the average number of defects can be drastically reduced for a very large but finite system, by optimizing the time dependence of the driving using optimal control techniques. Furthermore, the optimized protocol is robust against small fluctuations.
Resumo:
In this work we report on the evaluation of electron-impact collision strengths and Maxwellian averaged effective collision strengths for the lowly-ionized Fe-peak elements Sc II and Ti II using the parallel R-matrix package RMATRX II.
Resumo:
This paper discusses one of the major outstanding problems in atomic collision physics, namely the accurate theoretical treatment of electron scattering from open d-shell systems, and explores how this issue has been addressed over recent years with the development of the new parallel R-matrix suite of codes. It focuses on one code in particular - the new parallel R-matrix package PRMAT, which has recently been extended to account for relativistic fine-structure effects. This program facilitates the determination of accurate electron-impact excitation rates for complex open 3d-shell systems including the astrophysically important Fe-peak ions such as Ni II, Fe II and Fe III. Results are presented for collision strengths and Maxwellian averaged effective collision strengths for the optically forbidden fine-structure transitions of Ni II. To our knowledge this is the most extensive calculation completed to date for this ion.
Site symmetry dependence of repulsive interactions between chemisorbed oxygen atoms on Pt{100}-(1x1)
Resumo:
Ab initio total energy calculations using density functional theory with the generalized gradient approximation have been performed for the chemisorption of oxygen atoms on a Pt{100}-(1 x 1) slab. Binding energies for the adsorption of oxygen on different high-symmetry sites are presented. The bridge site is the most stable at a coverage of 0.5 ML, followed by the fourfold hollow site. The atop site is the least stable. This finding is rationalized by analyzing the ''local structures'' formed upon oxygen chemisorption. The binding energies and heats of adsorption at different oxygen coverages show that pairwise repulsive interactions are considerably stronger between oxygen atoms occupying fourfold sites than those occupying bridge sites. Analysis of the partial charge densities associated with Bloch states demonstrates that the O-Pt bond is considerably more localized at the bridge site. These effects cause a sharp drop in the heats of adsorption for oxygen on hollow sites when the coverage is increased from 0.25 to 0.5 ML. Mixing between oxygen p orbitals and Pt d orbitals can be observed over the whole metal d-band energy range.
Resumo:
Quantum and global discord in a spin-1 Heisenberg chain subject to single-ion anisotropy (uniaxial field) are studied using exact diagonalisation and the density matrix renormalisation group (DMRG). We find that these measures of quantum non-classicality are able to detect the quantum phase transitions confining the symmetry protected Haldane phase and show critical scaling with universal exponents. Moreover, in the case of thermal states, we find that quantum discord can increase with increasing temperature.
Resumo:
Demand Response (DR) algorithms manipulate the energy consumption schedules of controllable loads so as to satisfy grid objectives. Implementation of DR algorithms using a centralised agent can be problematic for scalability reasons, and there are issues related to the privacy of data and robustness to communication failures. Thus it is desirable to use a scalable decentralised algorithm for the implementation of DR. In this paper, a hierarchical DR scheme is proposed for Peak Minimisation (PM) based on Dantzig-Wolfe Decomposition (DWD). In addition, a Time Weighted Maximisation option is included in the cost function which improves the Quality of Service for devices seeking to receive their desired energy sooner rather than later. The paper also demonstrates how the DWD algorithm can be implemented more efficiently through the calculation of the upper and lower cost bounds after each DWD iteration.
Resumo:
The need for fast response demand side participation (DSP) has never been greater due to increased wind power penetration. White domestic goods suppliers are currently developing a `smart' chip for a range of domestic appliances (e.g. refrigeration units, tumble dryers and storage heaters) to support the home as a DSP unit in future power systems. This paper presents an aggregated population-based model of a single compressor fridge-freezer. Two scenarios (i.e. energy efficiency class and size) for valley filling and peak shaving are examined to quantify and value DSP savings in 2020. The analysis shows potential peak reductions of 40 MW to 55 MW are achievable in the Single wholesale Electricity Market of Ireland (i.e. the test system), and valley demand increases of up to 30 MW. The study also shows the importance of the control strategy start time and the staggering of the devices to obtain the desired filling or shaving effect.
Resumo:
Accurate determination of electron excitation rates for the Fe-peak elements is complicated by the presence of an open 3d-shell in the description of the target ion, which can lead to hundreds of target state energy levels. Furthermore, the low energy scattering region is dominated by series of Rydberg resonances, which require a very fine energy mesh for their delineation. These problems have prompted the development of a suite of parallel R-matrix codes. In this work we report recent applications of these codes to the study of electron impact excitation of Ni III and Ni IV.
Resumo:
Purpose: To investigate the clinical implications of a variable relative biological effectiveness (RBE) on proton dose fractionation. Using acute exposures, the current clinical adoption of a generic, constant cell killing RBE has been shown to underestimate the effect of the sharp increase in linear energy transfer (LET) in the distal regions of the spread-out Bragg peak (SOBP). However, experimental data for the impact of dose fractionation in such scenarios are still limited.
Methods and Materials: Human fibroblasts (AG01522) at 4 key depth positions on a clinical SOBP of maximum energy 219.65 MeV were subjected to various fractionation regimens with an interfraction period of 24 hours at Proton Therapy Center in Prague, Czech Republic. Cell killing RBE variations were measured using standard clonogenic assays and were further validated using Monte Carlo simulations and parameterized using a linear quadratic formalism.
Results: Significant variations in the cell killing RBE for fractionated exposures along the proton dose profile were observed. RBE increased sharply toward the distal position, corresponding to a reduction in cell sparing effectiveness of fractionated proton exposures at higher LET. The effect was more pronounced at smaller doses per fraction. Experimental survival fractions were adequately predicted using a linear quadratic formalism assuming full repair between fractions. Data were also used to validate a parameterized variable RBE model based on linear α parameter response with LET that showed considerable deviations from clinically predicted isoeffective fractionation regimens.
Conclusions: The RBE-weighted absorbed dose calculated using the clinically adopted generic RBE of 1.1 significantly underestimates the biological effective dose from variable RBE, particularly in fractionation regimens with low doses per fraction. Coupled with an increase in effective range in fractionated exposures, our study provides an RBE dataset that can be used by the modeling community for the optimization of fractionated proton therapy.
Resumo:
Os coeficientes de difusão (D 12) são propriedades fundamentais na investigação e na indústria, mas a falta de dados experimentais e a inexistência de equações que os estimem com precisão e confiança em fases comprimidas ou condensadas constituem limitações importantes. Os objetivos principais deste trabalho compreendem: i) a compilação de uma grande base de dados para valores de D 12 de sistemas gasosos, líquidos e supercríticos; ii) o desenvolvimento e validação de novos modelos de coeficientes de difusão a diluição infinita, aplicáveis em amplas gamas de temperatura e densidade, para sistemas contendo componentes muito distintos em termos de polaridade, tamanho e simetria; iii) a montagem e teste de uma instalação experimental para medir coeficientes de difusão em líquidos e fluidos supercríticos. Relativamente à modelação, uma nova expressão para coeficientes de difusão a diluição infinita de esferas rígidas foi desenvolvida e validada usando dados de dinâmica molecular (desvio relativo absoluto médio, AARD = 4.44%) Foram também estudados os coeficientes de difusão binários de sistemas reais. Para tal, foi compilada uma extensa base de dados de difusividades de sistemas reais em gases e solventes densos (622 sistemas binários num total de 9407 pontos experimentais e 358 moléculas) e a mesma foi usada na validação dos novos modelos desenvolvidos nesta tese. Um conjunto de novos modelos foi proposto para o cálculo de coeficientes de difusão a diluição infinita usando diferentes abordagens: i) dois modelos de base molecular com um parâmetro específico para cada sistema, aplicáveis em sistemas gasosos, líquidos e supercríticos, em que natureza do solvente se encontra limitada a apolar ou fracamente polar (AARDs globais na gama 4.26-4.40%); ii) dois modelos de base molecular biparamétricos, aplicáveis em todos os estados físicos, para qualquer tipo de soluto diluído em qualquer solvente (apolar, fracamente polar e polar). Ambos os modelos dão origem a erros globais entre 2.74% e 3.65%; iii) uma correlação com um parâmetro, específica para coeficientes de difusão em dióxido de carbono supercrítico (SC-CO2) e água líquida (AARD = 3.56%); iv) nove correlações empíricas e semi-empíricas que envolvem dois parâmetros, dependentes apenas da temperatura e/ou densidade do solvente e/ou viscosidade do solvente. Estes últimos modelos são muito simples e exibem excelentes resultados (AARDs entre 2.78% e 4.44%) em sistemas líquidos e supercríticos; e v) duas equações preditivas para difusividades de solutos em SC-CO2, em que os erros globais de ambas são inferiores a 6.80%. No global, deve realçar-se o facto de os novos modelos abrangerem a grande variedade de sistemas e moléculas geralmente encontrados. Os resultados obtidos são consistentemente melhores do que os obtidos com os modelos e abordagens encontrados na literatura. No caso das correlações com um ou dois parâmetros, mostrou-se que estes mesmos parâmetros podem ser ajustados usando um conjunto muito pequeno de dados, e posteriormente serem utilizados na previsão de valores de D 12 longe do conjunto original de pontos. Uma nova instalação experimental para medir coeficientes de difusão binários por técnicas cromatográficas foi montada e testada. O equipamento, o procedimento experimental e os cálculos analíticos necessários à obtenção dos valores de D 12 pelo método de abertura do pico cromatográfico, foram avaliados através da medição de difusividades de tolueno e acetona em SC-CO2. Seguidamente, foram medidos coeficientes de difusão de eucaliptol em SC-CO2 nas gamas de 202 – 252 bar e 313.15 – 333.15 K. Os resultados experimentais foram analisados através de correlações e modelos preditivos para D12.
Resumo:
This investigation aimed to explore the effects of inert sugar-free drinks described as either ‘performance enhancing’ (placebo) or ‘fatigue inducing’ (nocebo) on peak minute power (PMP;W) during incremental arm crank ergometry (ACE). Twelve healthy, non-specifically trained individuals volunteered to take part. A single-blind randomised controlled trial with repeated measures was used to assess for differences in PMP;W, oxygen uptake, heart rate (HR), minute ventilation, respiratory exchange ratio (RER) and subjective reports of local ratings of perceived exertion (LRPE) and central ratings of perceived exertion (CRPE), between three separate, but identical ACE tests. Participants were required to drink either 500 ml of a ‘sports performance’ drink (placebo), a ‘fatigue-inducing’ drink (nocebo) or water prior to exercise. The placebo caused a significant increase in PMP;W, and a significant decrease in LRPE compared to the nocebo (p=0.01; p=0.001) and water trials (p=0.01). No significant differences in PMP;W between the nocebo and water were found. However, the nocebo drink did cause a significant increase in LRPE (p=0.01). These results suggest that the time has come to broaden our understanding of the placebo and nocebo effects and their potential to impact sports performance.
Resumo:
This investigation aimed to explore the effects of inert sugar-free drinks described as either ‘performance enhancing’ (placebo) or ‘fatigue inducing’ (nocebo) on peak minute power (PMP;W) during incremental arm crank ergometry (ACE). Twelve healthy, non-specifically trained individuals volunteered to take part. A single-blind randomised controlled trial with repeated measures was used to assess for differences in PMP;W, oxygen uptake, heart rate (HR), minute ventilation, respiratory exchange ratio (RER) and subjective reports of local ratings of perceived exertion (LRPE) and central ratings of perceived exertion (CRPE), between three separate, but identical ACE tests. Participants were required to drink either 500 ml of a ‘sports performance’ drink (placebo), a ‘fatigue-inducing’ drink (nocebo) or water prior to exercise. The placebo caused a significant increase in PMP;W, and a significant decrease in LRPE compared to the nocebo (p=0.01; p=0.001) and water trials (p=0.01). No significant differences in PMP;W between the nocebo and water were found. However, the nocebo drink did cause a significant increase in LRPE (p=0.01). These results suggest that the time has come to broaden our understanding of the placebo and nocebo effects and their potential to impact sports performance.
Resumo:
Resumo Objectivos: Avaliação da Tosse em doentes com Doença Pulmonar Obstrutiva Crónica (DPOC). Identificar e determinar a relação dos factores preditivos que contribuem para a deterioração da capacidade de tosse nestes indivíduos. Tipo de estudo: Estudo observacional descritivo de natureza transversal. Definição dos casos: Os critérios de diagnóstico da DPOC são o quadro clínico e o Gold standard para diagnóstico da DPOC – a espirometria. População-alvo: Todos os utentes com patologia primária de DPOC diagnosticada que se desloquem ao serviço de função respiratória do Hospital de Viseu, para realizar provas. Método de Amostragem: Foi utilizada uma amostra aleatória constituída por todos os indivíduos, que cumpriram os critérios de inclusão, conscientes e colaborantes, que aceitaram participar neste estudo. Dimensão da amostra: Uma amostra de 55 indivíduos que se deslocaram ao serviço de função respiratória, entre Janeiro e Junho de 2009, para realizar provas de função respiratória. Condução do estudo: Os utentes que aceitaram participar neste estudo foram sujeitos a um questionário de dados clínicos e realizaram 5 testes: índice de massa corporal (IMC), estudo funcional respiratório e gasometria arterial, avaliação da força dos músculos respiratórios (PImax e PEmax) e avaliação do débito máximo da tosse (Peak Cough Flow). Análise estatística: Foram obtidos dados caracterizadores da amostra em estudo, sendo posteriormente correlacionado o valor de débito máximo da tosse (Peak Cough Flow) com os resultados obtidos para as avaliações do IMC, estudo funcional respiratório, PImax e PEmax, gasometria, avaliação da capacidade de Tosse e número de internamentos no último ano por agudização da DPOC. Tendo sido encontrados os valores de correlação entre o Peak Cough Flow e os restantes parâmetros. Resultados: Após análise dos resultados, foram obtidos os valores de Peak Cough Flow para a população com DPOC e verificou-se valores diminuídos em comparação com os valores normais da população, tendo-se verificado maiores valores de PCF em indivíduos do sexo masculino, em comparação aos valores do sexo feminino. Foi analisada a relação entre o PCF e a idade, peso, altura e IMC, não tendo sido encontrada relação, dado que a tosse não apresenta uma variação segundo os valores antropométricos, tal como a relação com os valores espirométricos. Quanto aos parâmetros funcionais respiratórios foram analisadas as relações com o PCF. Verificou-se relações significativas entre o PCF e o FEV1, a FVC, o PEF, apresentando uma relação positiva, onde maiores valores destes parâmetros estão correlacionados com maiores picos de tosse. Quanto a RAW e RV, o PCF apresenta uma relação negativa, onde uma maior resistência da via aérea ou doentes mais hiperinsuflados leva a menores valores de PCF. Por outro lado não foi encontrada relação entre o PCF e a FRC e o TLC. Quanto à força dos músculos respiratórios, verificou-se relação significativa com o PImax e a PEmax em que a fraqueza ao nível dos músculos respiratórios contribuem para um menor valor de PCF. Relativamente aos valores da gasometria arterial, verificou-se relação entre o PCF e a PaO2 de forma positiva, em que doentes hipoxémicos apresentam menores valores de tosse, e a PaCO2, de forma negativa, em que os doentes hipercápnicos apresentam menores valores de PCF tendo sido verificada relação entre o PCF e o pH e sO2. Quanto à relação entre o número de internamentos por agudização da DPOC no último ano e o PCF verificou-se uma relação significativa, onde um menor valor de PCF contribui para uma maior taxa de internamento por agudização da DPOC. Conclusão: Este conjunto de conclusões corrobora a hipótese inicialmente formulada, de que o Peak Cough Flow se encontra diminuído nos indivíduos com Doença Pulmonar Obstrutiva Crónica onde a variação do PCF se encontra directamente relacionada com os parâmetros funcionais respiratórios, com a força dos músculos respiratórios e com os valores de gasometria arterial. ABSTRACT: Aims: Cough evaluation in Chronic Obstructive Pulmonary Disease (COPD) patients. Identify and determine the relation of the predictive factors that contribute to the cough capacity degradation in this type of patients. Type of study: Descriptive observational study of transversal nature. Case definition: The COPD diagnosis criteria are the clinical presentation and the gold standard to the COPD diagnosis- the Spirometry. Target Population: Every patients, with primary pathology of COPD diagnosed, who went to the respiratory function service of Viseu hospital to perform tests. Sampling Method: It was used a random sample constituted by all the, conscious and cooperating individuals, who complied with the inclusion criteria and who accepted to make part of this study. Sample size: A sample of 55 individuals that went to the respiratory function service between January and June 2009 to perform respiratory function tests. Study: The patients who accepted to make part of this study were submitted to a clinical data questionary and performed 5 tests: body mass index (BMI), respiratory functional study, arterial blood gas level, evaluation of respiratory muscles strength (maximal inspiratory pressure (MIP) and maximum expiratory pressure (MEP)), and Peak Cough Flow evaluation. Statistic Analysis: Were obtained characterizing data of the sample in study, and later correlated the value of the Peak Cough Flow with the results from the evaluation of the body mass index (BMI), the respiratory functional study the MIP and MEP, the arterial blood gas level and also with the ability to cough evaluation and the number of hospitalizations in the last year for COPD exacerbations. The values of correlation between the Peak Cough Flow and the other parameters were found. Results: After analyzing the results, were obtained the values of Peak Cough Flow for the population with COPD. There were decreased values compared with the population normal values, having been found higher values of PCF in males compared to female values. It was analyzed the relation between the PCF and the age, weight, height and BMI but no relation was found on account of the fact that the cough does not show a variation according to anthropometric parameters, such as the relation with spirometric values. As for the respiratory functional parameters were analyzed relations with the PCF. There were significant relations between the PCF and FEV1, the FVC, the PEF, presenting a positive relation, where higher values of these parameters are correlated with higher incidence of cough. Concerning the RAW and RV, the PCF has a negative relation, in which a higher airway resistance or in more hyperinflated patients, leads to lower values of PCF. On the other hand no correlation was found between the PCF and the FRC and TLC. Regarding the respiratory muscle strength, there was a significant relation with the MIP and MEP, in which the weakness at the level of respiratory muscles contribute to a lower value of PCF. For values of arterial blood gas level, there was no relation between the PCF and PaO2, in a positive way, in which patients with hypoxemia present lower values of cough, and PaCO2, in a negative way in which hypercapnic patients had lower values of PCF, having being founded a relation between the PCF and the pH and sO2. As for the relation between the number of hospitalizations for COPD exacerbation in the last year and the PCF was found a significant relation, in which a smaller value of PCF contributes to a higher rate of hospitalization for COPD exacerbation. Conclusion: This set of findings supports the hypothesis first formulated that Peak Cough Flow is decreased in individuals with Chronic Obstructive Pulmonary Disease, in which the variation of the PCF is directly related to the respiratory function parameters, the strength of respiratory muscles and the values of arterial blood gases.