951 resultados para ocular ultrasound


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the long-term outcome (up to 7 years) of presumed ocular tuberculosis (TB) when the therapeutic decision was based on WHO guidelines. METHODS: Twelve out of 654 new uveitic patients (1998-2004) presented with choroiditis and positive tuberculosis skin test (TST) (skin lesion diameter >15 mm). Therapy was administered according to WHO recommendations after ophthalmic and systemic investigation. The area size of ocular lesions at presentation and after therapy, measured on fluorescein and indocyanine green angiographies, was considered the primary outcome. Relapse of choroiditis was considered a secondary outcome. The T-SPOT TB test was performed when it became available. RESULTS: Visual acuity significantly improved after therapy (p=0.0357). The mean total surface of fluorescein lesions at entry was 44.8 ± 20.9 (arbitrary units) and decreased to 32.5 ± 16.9 after therapy (p=0.0165). The mean total surface of indocyanine green lesions at entry was 24.5 ± 13.3 and decreased to 10.8 ± 5.4 after therapy (p=0.0631). The T-SPOT TB revealed 2 false TST-positive results. The mean follow-up was 4.5 ± 1.5 years. Two relapses out of 10 confirmed ocular TB was observed after complete lesion healing, 2.5 years and 4.5 years after therapy, respectively. CONCLUSIONS: A decrease of ocular lesion mean size and a mean improvement of VA were observed after antituberculous therapy. Our long-term follow-up of chorioretinal lesions demonstrated relapse of ocular tuberculosis in 10% of patients with confirmed ocular TB, despite complete initial retinal scarring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using a large prospective cohort of over 12,000 women, we determined 2 thresholds (high risk and low risk of hip fracture) to use in a 10-yr hip fracture probability model that we had previously described, a model combining the heel stiffness index measured by quantitative ultrasound (QUS) and a set of easily determined clinical risk factors (CRFs). The model identified a higher percentage of women with fractures as high risk than a previously reported risk score that combined QUS and CRF. In addition, it categorized women in a way that was quite consistent with the categorization that occurred using dual X-ray absorptiometry (DXA) and the World Health Organization (WHO) classification system; the 2 methods identified similar percentages of women with and without fractures in each of their 3 categories, but the 2 identified only in part the same women. Nevertheless, combining our composite probability model with DXA in a case findings strategy will likely further improve the detection of women at high risk of fragility hip fracture. We conclude that the currently proposed model may be of some use as an alternative to the WHO classification criteria for osteoporosis, at least when access to DXA is limited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-viral vectors for potential gene replacement and therapy have been developed in order to overcome the drawbacks of viral vectors. The diversity of non-viral vectors allows for a wide range of various products, flexibility of application, ease of use, low-cost of production and enhanced "genomic" safety. Using non-viral strategies, oligonucleotides (ODNs) can be delivered naked (less efficient) or entrapped in cationic lipids, polymers or peptides forming slow release delivery systems, which can be adapted according to the organ targeted and the therapy purposes. Tissue and cell internalization can be further enhanced by changing by physical or chemical means. Moreover, a specific vector can be selected according to disease course and intensity of manifestations fulfilling specific requirements such as the duration of drug release and its level along with cells and tissues specific targeting. From accumulating knowledge and experience, it appears that combination of several non-viral techniques may increase the efficacy and ensure the safety of these evolving and interesting gene therapy strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a case of xeroderma pigmentosum in a 9-year-old back Cameroonian boy. The diagnosis was based on typical clinical presentation of the disease: cutaneous atrophy, hypepigmented macules, and areas of depigmentation on sun exposed regions of the skin. Multiple tumoral lesions were localized on the head. Ocular findings were also present: conjunctival hyperemia, peripheral corneal opacification. Excision of the tumors and potoprotection was proposed for this patient. The role of tribal black African marriage traditions in disease transmission is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Quantitative ultrasound (QUS) is an attractive method for assessing fracture risk because it is portable, inexpensive, without ionizing radiation, and available in areas of the world where DXA is not readily accessible or affordable. However, the diversity of QUS scanners and variability of fracture outcomes measured in different studies is an important obstacle to widespread utilisation of QUS for fracture risk assessment. We aimed in this review to assess the predictive power of heel QUS for fractures considering different characteristics of the association (QUS parameters and fracture outcomes measured, QUS devices, study populations, and independence from DXA-measured bone density).Materials/Methods : We conducted an inverse-variance randomeffects meta-analysis of prospective studies with heel QUS measures at baseline and fracture outcomes in their follow-up. Relative risks (RR) per standard deviation (SD) of different QUS parameters (broadband ultrasound attenuation [BUA], speed of sound &SOS;, stiffness index &SI;, and quantitative ultrasound index [QUI]) for various fracture outcomes (hip, vertebral, any clinical, any osteoporotic, and major osteoporotic fractures) were reported based on study questions.Results : 21 studies including 55,164 women and 13,742 men were included with a total follow-up of 279,124 person-years. All four QUS parameters were associated with risk of different fractures. For instance, RR of hip fracture for 1 SD decrease of BUA was 1.69 (95% CI 1.43-2.00), SOS was 1.96 (95% CI 1.64-2.34), SI was 2.26 (95%CI 1.71-2.99), and QUI was 1.99 (95% CI 1.49-2.67). Validated devices from different manufacturers predicted fracture risks with a similar performance (meta-regression p-values>0.05 for difference of devices). There was no sign of publication bias among the studies. QUS measures predicted fracture with a similar performance in men and women. Meta-analysis of studies with QUS measures adjusted for hip DXA showed a significant and independent association with fracture risk (RR/SD for BUA =1.34 [95%CI 1.22-1.49]).Conclusions : This study confirms that QUS of the heel using validated devices predicts risk of different fracture outcomes in elderly men and women. Further research and international collaborations are needed for standardisation of QUS parameters across various manufacturers and inclusion of QUS in fracture risk assessment tools. Disclosure of Interest : None declared.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare the prediction of hip fracture risk of several bone ultrasounds (QUS), 7062 Swiss women > or =70 years of age were measured with three QUSs (two of the heel, one of the phalanges). Heel QUSs were both predictive of hip fracture risk, whereas the phalanges QUS was not. INTRODUCTION: As the number of hip fracture is expected to increase during these next decades, it is important to develop strategies to detect subjects at risk. Quantitative bone ultrasound (QUS), an ionizing radiation-free method, which is transportable, could be interesting for this purpose. MATERIALS AND METHODS: The Swiss Evaluation of the Methods of Measurement of Osteoporotic Fracture Risk (SEMOF) study is a multicenter cohort study, which compared three QUSs for the assessment of hip fracture risk in a sample of 7609 elderly ambulatory women > or =70 years of age. Two QUSs measured the heel (Achilles+; GE-Lunar and Sahara; Hologic), and one measured the heel (DBM Sonic 1200; IGEA). The Cox proportional hazards regression was used to estimate the hazard of the first hip fracture, adjusted for age, BMI, and center, and the area under the ROC curves were calculated to compare the devices and their parameters. RESULTS: From the 7609 women who were included in the study, 7062 women 75.2 +/- 3.1 (SD) years of age were prospectively followed for 2.9 +/- 0.8 years. Eighty women reported a hip fracture. A decrease by 1 SD of the QUS variables corresponded to an increase of the hip fracture risk from 2.3 (95% CI, 1.7, 3.1) to 2.6 (95% CI, 1.9, 3.4) for the three variables of Achilles+ and from 2.2 (95% CI, 1.7, 3.0) to 2.4 (95% CI, 1.8, 3.2) for the three variables of Sahara. Risk gradients did not differ significantly among the variables of the two heel QUS devices. On the other hand, the phalanges QUS (DBM Sonic 1200) was not predictive of hip fracture risk, with an adjusted hazard risk of 1.2 (95% CI, 0.9, 1.5), even after reanalysis of the digitalized data and using different cut-off levels (1700 or 1570 m/s). CONCLUSIONS: In this elderly women population, heel QUS devices were both predictive of hip fracture risk, whereas the phalanges QUS device was not.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: We report a case of digoxin intoxication with severe visual symptoms. Patients (or Materials) and Methods: Digoxin 0.25 mg QD for atrial fibrillation was prescribed to a 91-year-old woman with an estimated creatinine clearance of 18 mL/min. Within 2 to 3 weeks, she developed nausea, vomiting, and dysphagia, and began complaining of snowy and blurry vision, photopsia, dyschromatopsia, aggravated bedtime visual and proprioceptive illusions (she felt as being on a boat), and colored hallucinations. She consulted her family doctor twice and visited the eye clinic once until, 1 month after starting digoxin, impaired autonomy led her to be admitted to the emergency department. Results: Digoxin intoxication was confirmed by a high plasma level measured on admission (5.7 μg/L; reference range, 0.8-2 μg/L). After stopping digoxin, general symptoms resolved in a few days, but visual symptoms persisted. Ophtalmologic care and follow-up diagnosed digoxin intoxication superimposed on pre-existing left eye (LE) cataract, dry age-related macular degeneration (DMLA), and Charles Bonnet syndrome. Visual acuity was 0.4 (right eye, RE) and 0.5 (LE). Ocular fundus was physiologic except for bilateral dry DMLA. Dyschromatopsia was confirmed by poor results on Ishihara test (1/13 OU). Computerized visual field results revealed nonspecific diffuse alterations. Full-field electroretinogram (ERG) showed moderate diffuse rod and cone dysfunction. Visual symptoms progressively improved over the next 2 months, but ERG did not. Complete resolution was not expected due to the pre-existing eye disease. The patient was finally discharged home after a 5-week hospital stay. Conclusion: Digoxin intoxication can go unrecognized by clinicians, even in a typical presentation. The range of potential visual symptoms is far greater than isolated xanthopsia (yellow vision) classically described in textbooks. Newly introduced drugs and all symptoms must be actively sought after, because they significantly affect quality of life and global functioning, especially in the elderly population, most liable not to mention them.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the evaluation results of the methods submitted to Challenge US: Biometric Measurements from Fetal Ultrasound Images, a segmentation challenge held at the IEEE International Symposium on Biomedical Imaging 2012. The challenge was set to compare and evaluate current fetal ultrasound image segmentation methods. It consisted of automatically segmenting fetal anatomical structures to measure standard obstetric biometric parameters, from 2D fetal ultrasound images taken on fetuses at different gestational ages (21 weeks, 28 weeks, and 33 weeks) and with varying image quality to reflect data encountered in real clinical environments. Four independent sub-challenges were proposed, according to the objects of interest measured in clinical practice: abdomen, head, femur, and whole fetus. Five teams participated in the head sub-challenge and two teams in the femur sub-challenge, including one team who tackled both. Nobody attempted the abdomen and whole fetus sub-challenges. The challenge goals were two-fold and the participants were asked to submit the segmentation results as well as the measurements derived from the segmented objects. Extensive quantitative (region-based, distance-based, and Bland-Altman measurements) and qualitative evaluation was performed to compare the results from a representative selection of current methods submitted to the challenge. Several experts (three for the head sub-challenge and two for the femur sub-challenge), with different degrees of expertise, manually delineated the objects of interest to define the ground truth used within the evaluation framework. For the head sub-challenge, several groups produced results that could be potentially used in clinical settings, with comparable performance to manual delineations. The femur sub-challenge had inferior performance to the head sub-challenge due to the fact that it is a harder segmentation problem and that the techniques presented relied more on the femur's appearance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to develop a hip screening tool that combines relevant clinical risk factors (CRFs) and quantitative ultrasound (QUS) at the heel to determine the 10-yr probability of hip fractures in elderly women. The EPISEM database, comprised of approximately 13,000 women 70 yr of age, was derived from two population-based white European cohorts in France and Switzerland. All women had baseline data on CRFs and a baseline measurement of the stiffness index (SI) derived from QUS at the heel. Women were followed prospectively to identify incident fractures. Multivariate analysis was performed to determine the CRFs that contributed significantly to hip fracture risk, and these were used to generate a CRF score. Gradients of risk (GR; RR/SD change) and areas under receiver operating characteristic curves (AUC) were calculated for the CRF score, SI, and a score combining both. The 10-yr probability of hip fracture was computed for the combined model. Three hundred seven hip fractures were observed over a mean follow-up of 3.2 yr. In addition to SI, significant CRFs for hip fracture were body mass index (BMI), history of fracture, an impaired chair test, history of a recent fall, current cigarette smoking, and diabetes mellitus. The average GR for hip fracture was 2.10 per SD with the combined SI + CRF score compared with a GR of 1.77 with SI alone and of 1.52 with the CRF score alone. Thus, the use of CRFs enhanced the predictive value of SI alone. For example, in a woman 80 yr of age, the presence of two to four CRFs increased the probability of hip fracture from 16.9% to 26.6% and from 52.6% to 70.5% for SI Z-scores of +2 and -3, respectively. The combined use of CRFs and QUS SI is a promising tool to assess hip fracture probability in elderly women, especially when access to DXA is limited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Regarding recent progress, musculoskeletal ultrasound (US) will probably soon be integrated in standard care of patient with rheumatoid arthritis (RA). However, in daily care, quality of US machines and level of experience of sonographers are varied. We conducted a study to assess reproducibility and feasibility of an US scoring for RA, including US devices of different quality and rheumatologist with various levels of expertise in US as it would be in daily care. METHODS: The Swiss Sonography in Arthritis and Rheumatism (SONAR) group has developed a semi-quantitative score using OMERACT criteria for synovitis and erosion in RA. The score was taught to 108 rheumatologists trained in US. One year after the last workshop, 19 rheumatologists participated in the study. Scans were performed on 6 US machines ranging from low to high quality, each with a different patient. Weighted kappa was calculated for each pair of readers. RESULTS: Overall, the agreement was fair to moderate. Quality of device, experience of the sonographers and practice of the score before the study improved substantially the agreement. Agreement assessed on higher quality machine, among sonographers with good experience in US increased to substantial (median kappa for B-mode and Doppler: 0.64 and 0.41 for erosion). CONCLUSIONS: This study demonstrated feasibility and reproducibility of the Swiss US SONAR score for RA. Our results confirmed importance of the quality of US machine and the training of sonographers for the implementation of US scoring in the routine daily care of RA.