859 resultados para mean pondered diameter


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To report the MRI features of ECU accessory tendinous slips, assess their observable prevalence and evaluate a potential link between this anatomical variation and ECU tenosynovitis or tendinopathy. Methods and materials: Institutional review board approved this retrospective study, with waiver of patient informed consent. One hundred sixty wrist MRI studies from 158 patients (85 females, 73 males, mean age 45.6 years, range 14-86) performed between March 2008 and February 2009 on a 1.5-T unit were included. MR images were analyzed by two radiologists in consensus. The observable prevalence of ECU accessory tendinous slips was assessed and their origin, diameter and insertion sites were noted. The presence of ECU tenosynovitis and/or tendinopathy was also evaluated. Results: The observable prevalence of ECU accessory tendinous slips was 21.9% (35/160). The origin was always seen: 8 were at the level of, and 27 distal to the ECU subsheath. The slip median diameter was 0.67 mm (range 0.43-0.88). The insertion was seen in 17.1% (6/35): 2 were on the fifth metacarpal bone, 4 on the extensor apparatus of the fifth finger. ECU tenosynovitis (20%), tendinopathy (5.7%) as well as concomitant tenosynovitis and tendinopathy (25.7%) were more frequently encountered in the patients with the anatomical variation than in the control patients group (0.8%, 3.2% and 9.6% respectively). Differences were statistically significant for tenosynovitis (p = 0.0001) and concomitant tenosynovitis and tendinopathy (p = 0.02) of the ECU. Conclusion: ECU accessory tendinous slips are frequent and visible on 1.5-T wrist MRI studies. ECU tenosynovitis and tendinopathy are more frequent in patients bearing this anatomical variation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Cost effective means of assessing the levels of risk factors in the population have to be defined in order to monitor these factors over time and across populations. This study is aimed at analyzing the difference in population estimates of the mean levels of body mass index (BMI) and the prevalences of overweight, between health examination survey and telephone survey. METHODS: The study compares the results of two health surveys, one by telephone (N=820) and the other by physical examination (N=1318). The two surveys, based on independent random samples of the population, were carried out over the same period (1992-1993) in the same population (canton of Vaud, Switzerland). RESULTS: Overall participation rates were 67% and 53% for the health interview survey (HIS) and the health examination survey (HES) respectively. In the HIS, the reporting rate was over 98% for weight and height values. Self-reported weight was on average lower than measured weight, by 2.2 kg in men and 3.5 kg in women, while self-reported height was on average greater than measured height, by 1.2 cm in men and 1.9 cm in women. As a result, in comparison to HES, HIS led to substantially lower mean levels of BMI, and to a reduction of the prevalence rates of obesity (BMI>30 kg/m(2)) by more than a half. These differences are larger for women than for men. CONCLUSION: The two surveys were based on different sampling procedures. However, this difference in design is unlikely to explain the systematic bias observed between self-reported and measured values for height and weight. This bias entails the overall validity of BMI assessment from telephone surveys.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cannula design is of prime importance for venous drainage during cardiopulmonary bypass (CPB). To evaluate cannulas intended for CPB, an in vitro circuit was set up with silicone tubing between the test cannula encased in a movable preload reservoir and another static reservoir. The pressure-drop (DeltaP) value (P-drainage - P-preload) was measured using Millar pressure transducers. Flow rate (Q) was measured using an ultrasound flowmeter. Data display and data recording were controlled using a LabView application, custom made particularly for our experiments. Our results demonstrated that DeltaP, Q, and cannula resistance (DeltaP/Q) values were significantly decreased when the cannula diameter was increased for Smart and Medtronic cannulas. Smartcanula showed 36% and 43% less resistance compared to Medtronic venous and Medtronic femoral cannulas, respectively. The cannula shape (straight- or curved-tips) did not affect the DLP cannula resistance. Out of five cannulas tested, the Smartcanula outperforms the other commercially available cannulas. The mean (DeltaP/Q) values were 3.3 +/- 0.08, 4.07 +/- 0.08, 5.58 +/- 0.10, 5.74 +/- 0.15, and 6.45 +/- 0.15 for Smart, Medtronic, Edwards, Sarns, and Gambro cannulas, respectively (two-way ANOVA, p < 0.0001). In conclusion, the present assay allows discrimination between different forms of cannula with high or low lumen resistance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The workshop was attended by 13 people excluding facilitators. Most were from outside QUB (including Belfast City Council, NHSSB, BHSCT, Centre for Public Health, NICR, Institute of Agri-food and Land Use (QUB), etc).Programme was:Introductions Part 1: What’s “knowledge brokerage” all about?Presentation and Q&A (Kevin Balanda)Small group discussions Part 2: What the Centre of Excellence is doingPresentation and Q&A (Kevin Balanda)Small group discussions

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Moderate alcohol consumption has been associated with lower coronary artery disease (CAD) risk. However, data on the CAD risk associated with high alcohol consumption are conflicting. The aim of this study was to examine the impact of heavier drinking on 10-year CAD risk in a population with high mean alcohol consumption. In a population-based study of 5,769 adults (aged 35 to 75 years) without cardiovascular disease in Switzerland, 1-week alcohol consumption was categorized as 0, 1 to 6, 7 to 13, 14 to 20, 21 to 27, 28 to 34, and > or =35 drinks/week or as nondrinkers (0 drinks/week), moderate (1 to 13 drinks/week), high (14 to 34 drinks/week), and very high (> or =35 drinks/week). Blood pressure and lipids were measured, and 10-year CAD risk was calculated according to the Framingham risk score. Seventy-three percent (n = 4,214) of the participants consumed alcohol; 16% (n = 909) were high drinkers and 2% (n = 119) very high drinkers. In multivariate analysis, increasing alcohol consumption was associated with higher high-density lipoprotein cholesterol (from a mean +/- SE of 1.57 +/- 0.01 mmol/L in nondrinkers to 1.88 +/- 0.03 mmol/L in very high drinkers); triglycerides (1.17 +/- 1.01 to 1.32 +/- 1.05 mmol/L), and systolic and diastolic blood pressure (127.4 +/- 0.4 to 132.2 +/- 1.4 mm Hg and 78.7 +/- 0.3 to 81.7 +/- 0.9 mm Hg, respectively) (all p values for trend <0.001). Ten-year CAD risk increased from 4.31 +/- 0.10% to 4.90 +/- 0.37% (p = 0.03) with alcohol use, with a J-shaped relation. Increasing wine consumption was more related to high-density lipoprotein cholesterol levels, whereas beer and spirits were related to increased triglyceride levels. In conclusion, as measured by 10-year CAD risk, the protective effect of alcohol consumption disappears in very high drinkers, because the beneficial increase in high-density lipoprotein cholesterol is offset by the increases in blood pressure levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peripheral nerve injuries with loss of nervous tissue are a significant clinical problem and are currently treated using autologous nerve transplants. To avoid the need for donor nerve, which results in additional morbidity such as loss of sensation and scarring, alternative bridging methods have been sought. Recently we showed that an artificial nerve conduit moulded from fibrin glue is biocompatible to nerve regeneration. In this present study, we have used the fibrin conduit or a nerve graft to bridge either a 10 mm or 20 mm sciatic nerve gap and analyzed the muscle recovery in adult rats after 16 weeks. The gastrocnemius muscle weights of the operated side were similar for both gap sizes when treated with nerve graft. In contrast, muscle weight was 48.32 ± 4.96% of the contra-lateral side for the 10 mm gap repaired with fibrin conduit but only 25.20 ± 2.50% for the 20 mm gap repaired with fibrin conduit. The morphology of the muscles in the nerve graft groups showed an intact, ordered structure, with the muscle fibers grouped in fascicles whereas the 20 mm nerve gap fibrin group had a more chaotic appearance. The mean area and diameter of fast type fibers in the 20 mm gap repaired with fibrin conduits were significantly (P<0.01) worse than those of the corresponding 10 mm gap group. In contrast, both gap sizes treated with nerve graft showed similar fiber size. Furthermore, the 10 mm gaps repaired with either nerve graft or fibrin conduit showed similar muscle fiber size. These results indicate that the fibrin conduit can effectively treat short nerve gaps but further modification such as the inclusion of regenerative cells may be required to attain the outcomes of nerve graft for long gaps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Guide for Staff

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: To determine optimum spatial resolution when imaging peripheral arteries with magnetic resonance angiography (MRA). MATERIALS AND METHODS: Eight vessel diameters ranging from 1.0 to 8.0 mm were simulated in a vascular phantom. A total of 40 three-dimensional flash MRA sequences were acquired with incremental variations of fields of view, matrix size, and slice thickness. The accurately known eight diameters were combined pairwise to generate 22 "exact" degrees of stenosis ranging from 42% to 87%. Then, the diameters were measured in the MRA images by three independent observers and with quantitative angiography (QA) software and used to compute the degrees of stenosis corresponding to the 22 "exact" ones. The accuracy and reproducibility of vessel diameter measurements and stenosis calculations were assessed for vessel size ranging from 6 to 8 mm (iliac artery), 4 to 5 mm (femoro-popliteal arteries), and 1 to 3 mm (infrapopliteal arteries). Maximum pixel dimension and slice thickness to obtain a mean error in stenosis evaluation of less than 10% were determined by linear regression analysis. RESULTS: Mean errors on stenosis quantification were 8.8% +/- 6.3% for 6- to 8-mm vessels, 15.5% +/- 8.2% for 4- to 5-mm vessels, and 18.9% +/- 7.5% for 1- to 3-mm vessels. Mean errors on stenosis calculation were 12.3% +/- 8.2% for observers and 11.4% +/- 15.1% for QA software (P = .0342). To evaluate stenosis with a mean error of less than 10%, maximum pixel surface, the pixel size in the phase direction, and the slice thickness should be less than 1.56 mm2, 1.34 mm, 1.70 mm, respectively (voxel size 2.65 mm3) for 6- to 8-mm vessels; 1.31 mm2, 1.10 mm, 1.34 mm (voxel size 1.76 mm3), for 4- to 5-mm vessels; and 1.17 mm2, 0.90 mm, 0.9 mm (voxel size 1.05 mm3) for 1- to 3-mm vessels. CONCLUSION: Higher spatial resolution than currently used should be selected for imaging peripheral vessels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper conducts an empirical analysis of the relationship between wage inequality, employment structure, and returns to education in urban areas of Mexico during the past two decades (1987-2008). Applying Melly’s (2005) quantile regression based decomposition, we find that changes in wage inequality have been driven mainly by variations in educational wage premia. Additionally, we find that changes in employment structure, including occupation and firm size, have played a vital role. This evidence seems to suggest that the changes in wage inequality in urban Mexico cannot be interpreted in terms of a skill-biased change, but rather they are the result of an increasing demand for skills during that period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: An animal study was carried out to compare long-term patency rates of coronary anastomoses performed with the GraftConnector versus running suture technique. METHODS: 10 sheep, 45 to 55 kg, underwent off-pump coronary artery bypass grafting (right internal mammary artery to left anterior descending artery). In 5 animals, the anastomosis was performed with a GraftConnector and in 5 animals with 7-0 running suture. Intraoperative fluoroscopy and a fluoroscopic control at 6 months were performed. After 6 months, the animals were sacrificed and the anastomoses were examined histologically. RESULTS: All animals survived at 6 months with 100% anastomosis patency rates in both groups. In the GraftConnector group, the anastomosis diameter at 6 months fluoroscopy was 118% of native left anterior descending artery versus 97% of the control group. Luminal anastomotic width at histology was 1.7 +/- 0.2 mm in the device group versus 1.6 +/- 0.1 mm in the control group. Mean intimal hyperplasia thickness was 0.21 +/- 0.1 mm in the device group versus 0.01 mm in the control group. CONCLUSIONS: The GraftConnector provides a consistent and reproducible coronary artery anastomosis and reduces technical demand and manual dexterity in coronary operations. Long-term results demonstrate that off-pump coronary artery bypass grafting performed with the GraftConnector had the same patency rate and luminal width as those performed with running suture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated the potential of Mesocyclops annulatus as a control agent of Aedes aegypti in La Plata city (Argentina). Mosquito larval survivorship due to predation by these copepods was estimated at weekly intervals during the oviposition period of A. aegypti. Mean weekly A. aegypti larval survivorship in cylindrical plastic containers (12 cm height and 11 cm diameter) with copepods was significantly lower than in control containers. Furthermore, weekly larval survival was negatively correlated with M. annulatus adult density, and approximately 23 adult copepods/container would be a threshold density over which the weekly mosquito larval survivorship approached zero. The copepods were able to persist in all containers during approximately 100 days (in three of them until the end of the experiment: 155 days) without the resource represented by A. aegypti larvae. The predation and persistence observed suggest that M. annulatus is a potential control agent to be considered in biological control programs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Adducin is a membrane skeleton protein, which consists of either alpha- and beta- or alpha- and gamma-subunits. We investigated whether arterial characteristics might be related to the genes encoding ADD1 (Gly460Trp-rs4961), ADD2 (C1797T-rs4984), and ADD3 (IVS11+386A>G-rs3731566). METHODS: We randomly recruited 1,126 Flemish subjects (mean age, 43.8 years; 50.3% women). Using a wall-tracking ultrasound system, we measured the properties of the carotid, femoral, and brachial arteries. We studied multivariate-adjusted phenotype-genotype associations, using a population- and family-based approach. RESULTS: In single-gene analyses, brachial diameter was 0.15 mm (P = 0.0022) larger, and brachial distensibility and cross-sectional compliance were 1.55 x 10(-3)/kPa (P = 0.013) and 0.017 mm(2)/kPa (P = 0.0029) lower in ADD3 AA than ADD3 GG homozygotes with an additive effect of the G allele. In multiple-gene analyses, the association of brachial diameter and distensibility with the ADD3 G allele occurred only in ADD1 GlyGly homozygotes. Otherwise, the associations between the arterial phenotypes in the three vascular beds and the ADD1 or ADD2 polymorphisms were not significant. In family-based analyses, the multivariate-adjusted heritability was 0.52, 0.38, and 0.30 for brachial diameter, distensibility, and cross-sectional compliance, respectively (P < 0.001). There was no evidence for population stratification (0.07 < or = P < or = 0.96). Transmission of the mutated ADD3 G allele was associated with smaller brachial diameter in 342 informative offspring (-0.12 +/- 0.04 mm; P = 0.0085) and in 209 offspring, who were ADD1 GlyGly homozygotes (-0.14 +/- 0.06 mm; P = 0.018). CONCLUSIONS: In ADD1 GlyGly homozygotes, the properties of the brachial artery are related to the ADD3 (A386G) polymorphism, but the underlying mechanism needs further clarification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous studies reported on the association of left ventricular mass index (LVMI) with urinary sodium or with circulating or urinary aldosterone. We investigated the independent associations of LVMI with the urinary excretion of both sodium and aldosterone. We randomly recruited 317 untreated subjects from a white population (45.1% women; mean age 48.2 years). Measurements included echocardiographic left ventricular (LV) properties, the 24-hour urinary excretion of sodium and aldosterone, plasma renin activity (PRA), and proximal (RNa(prox)) and distal (RNa(dist)) renal sodium reabsorption, assessed from the endogenous lithium clearance. In multivariable-adjusted models, we expressed changes in LVMI per 1-SD increase in the explanatory variables, while accounting for sex, age, systolic blood pressure, and the waist-to-hip ratio. LVMI increased independently with the urinary excretion of both sodium (+2.48 g/m(2); P=0.005) and aldosterone (+2.63 g/m(2); P=0.004). Higher sodium excretion was associated with increased mean wall thickness (MWT: +0.126 mm, P=0.054), but with no change in LV end-diastolic diameter (LVID: +0.12 mm, P=0.64). In contrast, higher aldosterone excretion was associated with higher LVID (+0.54 mm; P=0.017), but with no change in MWT (+0.070 mm; P=0.28). Higher RNa(dist) was associated with lower relative wall thickness (-0.81x10(-2), P=0.017), because of opposite trends in LVID (+0.33 mm; P=0.13) and MWT (-0.130 mm; P=0.040). LVMI was not associated with PRA or RNa(prox.) In conclusion, LVMI independently increased with both urinary sodium and aldosterone excretion. Increased MWT explained the association of LVMI with urinary sodium and increased LVID the association of LVMI with urinary aldosterone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthèse : Mesures de l'aorte ascendante par scanner synchronisé au rythme cardiaque: une étude pilote pour établir des valeurs normatives dans le cadre des futures thérapies par transcathéter. Objectif : L'objectif de cette étude est d'établir les valeurs morphométriques normatives de l'aorte ascendante à l'aide de l'angiographie par scanner synchronisé au rythme cardiaque, afin d'aider au développement des futurs traitements par transcathéter. Matériels et méthodes : Chez soixante-dix-sept patients (âgé de 22 à 83 ans, âge moyen: 54,7 ans), une angiographie par scanner synchronisé au rythme cardiaque a été réalisée pour évaluation des vaisseaux coronaires. Les examens ont été revus afin d'étudier l'anatomie de la chambre de chasse du ventricule gauche jusqu'au tronc brachio-céphalique droit. A l'aide de programmes de reconstructions multiplanaires et de segmentation automatique, différents diamètres et longueurs considérés comme importants pour les futurs traitements par transcathéter ont été mesurés. Les valeurs sont exprimées en moyennes, médianes, maximums, minimums, écart-types et en coefficients de variation. Les variations de diamètre de l'aorte ascendante durant le cycle cardiaque ont été aussi considérées. Résultats : Le diamètre moyen de la chambre de chasse du ventricule gauche était de 20.3+/-3.4 mm. Au niveau du sinus coronaire de l'aorte, il était de 34.2+/-4.1 mm et au niveau de la jonction sinotubulaire il était de 29.7+/-3.4 mm. Le diamètre moyen de l'aorte ascendante était de 32.7+/-3.8 mm. Le coefficient de variation de ces mesures variait de 12 à 17%. La distance moyenne entre l'insertion proximale des valvules aortiques et le départ du tronc brachio-céphalique droit était de 92.6+/-11.8 mm. La distance moyenne entre l'insertion proximale des valvules aortiques et l'origine de l'artère coronaire proximale était de 12.1+/-3.7 mm avec un coefficient de variation de 31%. La distance moyenne entre les deux ostia coronaires était de 7.2+/-3.1 mm avec un coefficient de variation de 43%. La longueur moyenne du petit arc de l'aorte ascendante entre l'artère coronaire gauche et le tronc brachio-céphalique droit était de 52.9+/-9.5 mm. La longueur moyenne de la continuité fibreuse entre la valve aortique et la valvule mitrale antérieure était de 14.6+/-3.3 mm avec un coefficient de variation de 23%. L'aire moyenne de la valve aortique était de 582.0+/-131.9 mm2. La variation du diamètre antéro-postérieur et transverse de l'aorte ascendante était respectivement de 8.4% et de 7.3%. Conclusion Il existe d'importantes variations inter-individuelles dans les mesures de l'aorte ascendante avec cependant des variations intra-individuelles faibles durant le cycle cardiaque. De ce fait, une approche personnalisée pour chaque patient est recommandée dans la confection des futures endoprothèses de l'aorte ascendante. Le scanner synchronisé au rythme cardiaque jouera un rôle prépondérant dans le bilan préthérapeutique. Abstract : The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3+/-3.4, coronary sinus 34.2+/-4.1, sinotubular junction 29.7+-3.4 and mid ascending aorta 32.7+/-3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6111.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1+/-3.7, and between both coronary ostia 7.2+/-3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9 X9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.óf3.3, CV 13-43%. Mean aortic valve area was 582+-131.9 mm2. The variations of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered.