896 resultados para gain measurement
Resumo:
Sirt3 is a mitochondrial NAD(+)-dependent deacetylase that governs mitochondrial metabolism and reactive oxygen species homeostasis. Sirt3 deficiency has been reported to accelerate the development of the metabolic syndrome. However, the role of Sirt3 in atherosclerosis remains enigmatic. We aimed to investigate whether Sirt3 deficiency affects atherosclerosis, plaque vulnerability, and metabolic homeostasis. Low-density lipoprotein receptor knockout (LDLR(-/-)) and LDLR/Sirt3 double-knockout (Sirt3(-/-)LDLR(-/-)) mice were fed a high-cholesterol diet (1.25 % w/w) for 12 weeks. Atherosclerosis was assessed en face in thoraco-abdominal aortae and in cross sections of aortic roots. Sirt3 deletion led to hepatic mitochondrial protein hyperacetylation. Unexpectedly, though plasma malondialdehyde levels were elevated in Sirt3-deficient mice, Sirt3 deletion affected neither plaque burden nor features of plaque vulnerability (i.e., fibrous cap thickness and necrotic core diameter). Likewise, plaque macrophage and T cell infiltration as well as endothelial activation remained unaltered. Electron microscopy of aortic walls revealed no difference in mitochondrial microarchitecture between both groups. Interestingly, loss of Sirt3 was associated with accelerated weight gain and an impaired capacity to cope with rapid changes in nutrient supply as assessed by indirect calorimetry. Serum lipid levels and glucose tolerance were unaffected by Sirt3 deletion in LDLR(-/-) mice. Sirt3 deficiency does not affect atherosclerosis in LDLR(-/-) mice. However, Sirt3 controls systemic levels of oxidative stress, limits expedited weight gain, and allows rapid metabolic adaptation. Thus, Sirt3 may contribute to postponing cardiovascular risk factor development.
Resumo:
Aortic stiffness is an independent predictor factor for cardiovascular risk. Different methods for determining pulse wave velocity (PWV) are used, among which the most common are mechanical methods such as SphygmoCor or Complior, which require specific devices and are limited by technical difficulty in obtaining measurements. Doppler guided by 2D ultrasound is a good alternative to these methods. We studied 40 patients (29 male, aged 21 to 82 years) comparing the Complior method with Doppler. Agreement of both devices was high (R = 0.91, 0.84-0.95, 95% CI). The reproducibility analysis revealed no intra-nor interobserver differences. Based on these results, we conclude that Doppler ultrasound is a reliable and reproducible alternative to other established methods for themeasurement of aortic PWV
Resumo:
Epidemiological studies have shown that obesity is associated with chronic kidney disease and end stage renal disease. These studies have used creatinine derived equations to estimate glomerular filtration rate (GFR) and have indexed GFR to body surface area (BSA). However, the use of equations using creatinine as a surrogate marker of glomerular filtration and the indexation of GFR for BSA can be questioned in the obese population. First, these equations lack precision when they are compared to gold standard GFR measurements such as inulin clearances; secondly, the indexation of GFR for 1.73 m(2) of BSA leads to a systematic underestimation of GFR compared to absolute GFR in obese patients who have BSA that usually exceed 1.73 m(2). Obesity is also associated with pathophysiological changes that can affect the pharmacokinetics of drugs. The effect of obesity on both renal function and drug pharmacokinetics raises the issue of correct drug dosage in obese individuals. This may be particularly relevant for drugs known to have a narrow therapeutic range or excreted by the kidney.
Resumo:
To evaluate the severity of airway pathologies, quantitative dimensioning of airways is of utmost importance. Endoscopic vision gives a projective image and thus no true scaling information can be directly deduced from it. In this article, an approach based on an interferometric setup, a low-coherence laser source and a standard rigid endoscope is presented, and applied to hollow samples measurements. More generally, the use of the low-coherence interferometric setup detailed here could be extended to any other endoscopy-related field of interest, e.g., gastroscopy, arthroscopy and other medical or industrial applications where tri-dimensional topology is required. The setup design with a multiple fibers illumination system is presented. Demonstration of the method ability to operate on biological samples is assessed through measurements on ex vivo pig bronchi.
Resumo:
Perfusion CT studies of regional cerebral blood flow (rCBF), involving sequential acquisition of cerebral CT sections during IV contrast material administration, have classically been reported to be achieved at 120 kVp. We hypothesized that using 80 kVp should result in the same image quality while significantly lowering the patient's radiation dose, and we evaluated this assumption. In five patients undergoing cerebral CT survey, one section level was imaged at 120 kVp and 80 kVp, before and after IV administration of iodinated contrast material. These four cerebral CT sections obtained in each patient were analyzed with special interest to contrast, noise, and radiation dose. Contrast enhancement at 80 kVp is significantly increased (P < .001), as well as contrast between gray matter and white matter after contrast enhancement (P < .001). Mean noise at 80 kVp is not statistically different (P = .042). Finally, performance of perfusion CT studies at 80 kVp, keeping mAs constant, lowers the radiation dose by a factor of 2.8. We, thus, conclude that 80 kVp acquisition of perfusion CT studies of rCBF will result in increased contrast enhancement and should improve rCBF analysis, with a reduced patient's irradiation.
Resumo:
The rate-limiting step of dietary calcium absorption in the intestine requires the brush border calcium entry channel TRPV6. The TRPV6 gene was completely sequenced in 170 renal calcium stone patients. The frequency of an ancestral TRPV6 haplotype consisting of three non-synonymous polymorphisms (C157R, M378V, M681T) was significantly higher (P = 0.039) in calcium stone formers (8.4%; derived = 502, ancestral = 46) compared to non-stone-forming individuals (5.4%; derived = 645, ancestral = 37). Mineral metabolism was investigated on four different calcium regimens: (i) free-choice diet, (ii) low calcium diet, (iii) fasting and (iv) after a 1 g oral calcium load. When patients homozygous for the derived haplotype were compared with heterozygous patients, no differences were found with respect to the plasma concentrations of 1,25-vitamin D, PTH and calcium, and the urinary excretion of calcium. In one stone-forming patient, the ancestral haplotype was found to be homozygous. This patient had absorptive hypercalciuria. We therefore expressed the ancestral protein (157R+378V+681T) in Xenopus oocytes and found a significantly enhanced calcium permeability when tested by a (45)Ca(2+) uptake assay (7.11 +/- 1.93 versus 3.61 +/- 1.01 pmol/min/oocyte for ancestral versus derived haplotype, P < 0.01). These results suggest that the ancestral gain-of-function haplotype in TRPV6 plays a role in calcium stone formation in certain forms of absorptive hypercalciuria.
Resumo:
In 58 newborn infants a new iridium oxide sensor was evaluated for transcutaneous carbon dioxide (tcPCO2) monitoring at 42 degrees C with a prolonged fixation time of 24 hours. The correlation of tcPCO2 (y; mm Hg) v PaCO2 (x; mm Hg) for 586 paired values was: y = 4.6 + 1.45x; r = .89; syx = 6.1 mm Hg. The correlation was not influenced by the duration of fixation. The transcutaneous sensor detected hypocapnia (PaCO2 less than 35 mm Hg) in 74% and hypercapnia (PCO2 greater than 45 mm Hg) in 74% of all cases. After 24 hours, calibration shifts were less than 4 mm Hg in 90% of the measuring periods. In 86% of the infants, no skin changes were observed; in 12% of infants, there were transitional skin erythemas and in 2% a blister which disappeared without scarring. In newborn infants with normal BPs, continuous tcPCO2 monitoring at 42 degrees C can be extended for as many as 24 hours without loss of reliability or increased risk for skin burns.
Resumo:
Abstract Dynamics is a central aspect of ski jumping, particularly during take-off and stable flight. Currently, measurement systems able to measure ski jumping dynamics (e.g. 3D cameras, force plates) are complex and only available in few research centres worldwide. This study proposes a method to determine dynamics using a wearable inertial sensor-based system which can be used routinely on any ski jumping hill. The system automatically calculates characteristic dynamic parameters during take-off (position and velocity of the centre of mass perpendicular to the table, force acting on the centre of mass perpendicular to the table and somersault angular velocity) and stable flight (total aerodynamic force). Furthermore, the acceleration of the ski perpendicular to the table was quantified to characterise the skis lift at take-off. The system was tested with two groups of 11 athletes with different jump distances. The force acting on the centre of mass, acceleration of the ski perpendicular to the table, somersault angular velocity and total aerodynamic force were different between groups and correlated with the jump distances. Furthermore, all dynamic parameters were within the range of prior studies based on stationary measurement systems, except for the centre of mass mean force which was slightly lower.
Resumo:
Controlling the extracellular volume in hemodialysis patients is a difficult task. The aim of this study was to evaluate the capacity of different methods of stimulated sweating to reduce mean interdialytic weight gain (IWG), to improve blood pressure regulation, and potassium/urea balance. Two center, crossover pilot study. In Lausanne, hemodialysis patients took four hot-water baths a week, 30 minutes each, on nondialysis days during 1 month. In Sfax, patients visited the local Hammam Center four times a week. Hemodynamic parameters were recorded, and weekly laboratory analysis was performed. Results were compared with a preceding 1-month control period. In Lausanne, five patients (all men, median age 55 years) participated. Bathing temperature was (mean ± standard deviation) 41.2 ± 3°C and sweating-induced weight loss 600 ± 500 g. Mean IWG (control vs. intervention period) decreased from 2.3 ± 0.9 to 1.8 ± 1 kg (P = 0.004), Systolic blood pressure from 139 ± 21 to 136 ± 22 mmHg (P = 0.4), and diastolic blood pressure form 79 ± 12 to 75 ± 13 mmHg (P = 0.08); antihypertensive therapy could be reduced from 2.8 ± 0.4 to 1.9 ± 0.5 antihypertensive drugs per patient (P = 0.01). In Sfax (n = 9, median age 46 years), weight loss per Hammam session was 420 ± 100 g. No differences were found in IWG or BP, but predialysis serum potassium level decreased from 5.9 ± 0.8 to 5.5 ± 0.9 mmol/L (P = 0.04) and urea from 26.9 ± 6 to 23.1 ± 6 mmol/L (P = 0.02). Hot-water baths appear to be a safe way to reduce IWG in selected hemodialysis patients. Hammam visits reduce serum potassium and urea levels, but not IWG. More data in larger patient groups are necessary before definite conclusion can be drawn.
Resumo:
En els darrers anys, els sistemes de telemetria per a aplicacions mèdiques han crescut significativament en el diagnòstic i en la monitorització de, per exemple, la glucosa, la pressió de la sang, la temperatura, el ritme cardíac... Els dispositius implantats amplien les aplicacions en medicina i incorpora una millora de qualitat de vida per a l’usuari. Per aquest motiu, en aquest projecte s’estudien dues de les antenes més comuns, com son l’antena dipol i el patch, aquesta última és especialment utilitzada en aplicacions implantades. En l’anàlisi d’aquestes antenes s’han parametritzat característiques relacionades amb l’entorn de l’aplicació, així com també de la pròpia antena, explicant el comportament que, a diferencia amb l’espai lliure, les antenes presenten a canvis d’aquests paràmetres. Al mateix temps, s’ha implementat una configuració per a la mesura d’antenes implantades basat en el model del cos humà d’una capa. Comparant amb els resultats de les simulacions realitzades mitjançant el software FEKO, s’ha obtingut gran correspondència en la mesura empírica d’adaptació i de guany de les antenes microstrip. Gràcies a l’anàlisi paramètric, aquest projecte també presenta diversos dissenys de les antenes optimitzant el guany realitzable amb l’objectiu d’aconseguir la millor comunicació possible amb el dispositiu extern o estació base.
Resumo:
In the last decades; a growing stock of literature has been devoted to the criticism of GDP as an indicator of societal wealth. A relevant question is: what are the perspectives to build, on the existing knowledge and consensus, alternative measures of prosperity? A starting point may be to connect well-being research agenda with the sustainability one. However, there is no doubt that there is a lot of complexity and fuzziness inherent in multidimensional concepts such as sustainability and well-being. This article analyses the theoretical foundations and the empirical validity of some multidimensional technical tools that can be used for well-being evaluation and assessment. Of course one should not forget that policy conclusions derived through any mathematical model depend also on the conceptual framework used, i.e. which representation of reality (and thus which societal values and interests) has been considered.
Resumo:
Background: The COSMIN checklist (COnsensus-based Standards for the selection of health status Measurement INstruments) was developed in an international Delphi study to evaluate the methodological quality of studies on measurement properties of health-related patient reported outcomes (HR-PROs). In this paper, we explain our choices for the design requirements and preferred statistical methods for which no evidence is available in the literature or on which the Delphi panel members had substantial discussion. Methods: The issues described in this paper are a reflection of the Delphi process in which 43 panel members participated. Results: The topics discussed are internal consistency (relevance for reflective and formative models, and distinction with unidimensionality), content validity (judging relevance and comprehensiveness), hypotheses testing as an aspect of construct validity (specificity of hypotheses), criterion validity (relevance for PROs), and responsiveness (concept and relation to validity, and (in) appropriate measures).Conclusions: We expect that this paper will contribute to a better understanding of the rationale behind the items, thereby enhancing the acceptance and use of the COSMIN checklist.
Resumo:
Background: The COSMIN checklist is a tool for evaluating the methodological quality of studies on measurement properties of health-related patient-reported outcomes. The aim of this study is to determine the inter-rater agreement and reliability of each item score of the COSMIN checklist (n = 114). Methods: 75 articles evaluating measurement properties were randomly selected from the bibliographic database compiled by the Patient-Reported Outcome Measurement Group, Oxford, UK. Raters were asked to assess the methodological quality of three articles, using the COSMIN checklist. In a one-way design, percentage agreement and intraclass kappa coefficients or quadratic-weighted kappa coefficients were calculated for each item. Results: 88 raters participated. Of the 75 selected articles, 26 articles were rated by four to six participants, and 49 by two or three participants. Overall, percentage agreement was appropriate (68% was above 80% agreement), and the kappa coefficients for the COSMIN items were low (61% was below 0.40, 6% was above 0.75). Reasons for low inter-rater agreement were need for subjective judgement, and accustom to different standards, terminology and definitions.Conclusions: Results indicated that raters often choose the same response option, but that it is difficult on item level to distinguish between articles. When using the COSMIN checklist in a systematic review, we recommend getting some training and experience, completing it by two independent raters, and reaching consensus on one final rating. Instructions for using the checklist are improved.