605 resultados para disks


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Feeding preference of adults of Metriona elatior Klug (Coleoptera: Chrysomelidae, Cassidinae) for different hybrids of Solanum melogena Linnaeus (Solanaceae). Metriona elatior Klug is a potential biocontrol agent for Solanum viarum Dunal (tropical soda apple), because larvae and adults feed on its leaves and this species shows a low dispersion rate. Specificity plays a major role in the feasibility of an organism as a biological control agent, especially in the inundative strategy. The feeding preference of M. elatior adults was evaluated to 14 eggplant (Solanum melogena Linnaeus) hybrids. Mass rearing was carried out under lab conditions, with the insect feeding directly on S. viarum leaves. The study started with dual and multiple choice tests in 24 and 48 hour feeding times, by offering leaf disks in Petri dish conditions. Survival and leaf consumption analysis were performed in newly adults in tropical soda apple and eggplant leaves kept turgid by immersing the petioles in water. The leaf area was measured before and after four days of insect exposure. M. elatior showed higher feeding preference, survival and consumption of the weed species, especially in comparison with the hybrid Ryoma. The highest feeding preference among the eggplant hybrids was observed in 'Minikuro Kowishiki'.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents an experimental study on the life of abrasive discs in cut-off type operations with two conditions of cutting speed. The cutting time is shown with a comparative analysis of the cutting speed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The antimicrobial activity of irrigating solutions - Endoquil (castor oil detergent), 2% chlorhexidine gluconate solution, and 0.5% NaOCI solution - was evaluated against Gram-positive cocci (Micrococcus luteus, Staphylococcus aureus, Enterococcus faecalis, Staphylococcus epidermidis, Streptococcus mutans, and Streptococcus sobrinus), Gramnegative rods (Escherichia coli and Pseudomonas aeruginosa), and the yeast Candida albicans. Activity was evaluated using the two-layer agar diffusion technique. The base layer was obtained by pouring 10.0 ml of Muller Hinton Medium or 10.0 ml of Brain Heart Infusion agar in a Petri dish. After solidification a 5.0 ml seed layer of Muller Hinton Medium or Brain Heart Infusion agar with inoculum (106/ml) was added. Absorbent paper disks (6.0 mm in diameter) immersed in the solutions were placed at equidistant points. Plates were maintained at room temperature for 2 h for prediffusion of the solutions and incubated at 37°C for 24 h. The candle jar system was used for the Brain Heart Infusion agar plates. All tests were performed in duplicate. After incubation the medium was optimized with 0.05 g% triphenyltetrazolium chlorate gel and inhibition halos were measured. All bacterial strains were inhibited by 2.0% chlorhexidine gluconate. Endoquil was effective against Grampositive microorganisms, and 0.5% NaOCI was effective only against S. aureus. Copyright © 2001 by The American Association of Endodontists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tests were carried out to evaluate resistance of common bean (Phaseolus vulgaris L.) to Diabrotica speciosa (Ger.) with the genotypes Goiano Precoce, Jalo Precoce, PR 95105146, PR 95105142 (Andean domestication center, AN), Emgopa 201 Ouro and IAPAR 57 (Middle American domestication center, MA). The experiments were conducted in 1998 and 1999, at the farm of UNESP-FCAV, Jaboticabal, SP, Brazil. The genotypes were planted in pots and 20 day-old leaflets were collected and foliar disks were cut of for the test. Two trials, a no-choice test and a free-choice test, were set up in BOD. In free-choice test, two disks of each genotype were kept in a 140-mm-diameter petri dish (total of 12 disks), where 12 adults were confined. In no-choice test, two disks of one genotype and two insects were placed in a 60-mm-diameter petri dish. A field experiment was conducted when 400 adults of D. speciosa were released. Fifteen leaflets per plot were collected 30 days after planting and the leaf area consumption was evaluated. A no-choice experiment was carried out with 20 day-old genotypes protected in individual cages and infested by 10 adults, for 72h. The MA genotypes were the most preferred on feeding tests conducted at BOD, field and individual cages, while the AN genotypes were less eaten.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new species of hylid frog is described from south of the State of São Paulo, southeastern Brazil in Atlantic rain forest. The new species is a member of the genus Phrynohyas and is characterized by snout rounded in dorsal view and nearly truncate in lateral view, small adhesive disks, fingers slightly webbed, nasal bones widely separated, and frontoparietals without medial articulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of 2% chlorhexidine on the microtensile bond strength of composite resin to dentin treated with three dentin bonding systems. Materials and Methods: Flat dentinal surfaces were prepared in 24 extracted human third molars. Teeth were randomly divided into 8 distinct experimental groups according to the adhesive applied (Prime & Bond NT, Single Bond and Clearfil SE Bond), the application (yes/no) of chlorhexidine, and the time point at which it was applied (before or after acid etching the dentin). Composite resin blocks were built up over treated surfaces, and teeth were then stored in water at 37°C for 24 h. Samples were thermocycled, stored under the same conditions, and then vertically sectioned, thus obtaining specimens with 1.0 ± 0.1 mm2 cross-sectional area. Specimens were stressed in tension at 0.5 mm/min crosshead speed. Bond strength results were evaluated using a one-way ANOVA (p < 0.05). The modes of failures were verified using optical microscopy. Dentin disks were obtained from 3 additional teeth treated in the same manner for observation under SEM. The most representative samples of fractured specimens were also observed under SEM. Results: No statistically significant differences of bond strength values were found between any groups. Failures occurred mainly within the bond; exclusively adhesive fractures (adhesive-dentin) were not observed. Conclusion: The 2% chlorhexidine solution, applied before or after acid etching of the dentin, did not interfere with the microtensile bond strength of composite resin to the dentin treated with Prime & Bond NT, Single Bond, or Clearfil SE Bond bonding systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Essential oils were obtained from fennel seeds, dill, cumin and coriander. Their antimicrobial activity was tested on isolated clinical specimens of patients treated at the University Hospital of the School of Medicine of Botucatu, SP, UNESP. Microorganisms were grown in BHI (Brain Heart Infusion/Oxoid) at 37oC/18 hours and resuspended in 0,5 Mac Farland's Standard (1,5 x 108 CFU/mL). The diffusion method was performed, putting 10 μl of the essential oils on paper disks (6mm of diameter) (Blank Disks/CECON) at 37oC/24 hours. After this period, the disks were put on plates containing Mueller Hinton Agar (Oxoid) and inoculated with the microorganisms. After 48 hours at 37oC, inhibitory zones were measured (mm) for the respective oils and strains. The essential oil from Anethum graveolens showed antimicrobial activity against Staphylococcus aureus (inhibitory zone=18 mm), Salmonella sp. (=11 mm) and E. coli (10 mm). The Cuminum cyminum essential oil was effective against E. coli, P. aeruginosa and Salmonella sp. and their inhibitory zones were 18, 10 and 23 mm, respectively. Coriandrum sativum oil was active only against Salmonella sp. (18 mm) and Foeniculum vulgare inhibited only E. coli (9 mm).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study compared the effect of two postpolymerization heat treatments on the cytotoxicity of three denture base resins on L929 cells using 3H-thymidine incorporation and MTT assays. Materials and Methods: Sample disks of Lucitone 550, QC 20, and Acron MC resins were fabricated under aseptic conditions and stored in distilled water at 37°C for 48 hours. Specimens were then divided into three groups: (1) heat treated in microwave oven for 3 minutes at 500 W; (2) heat treated in water bath at 55°C for 60 minutes; and (3) no heat treatment. Eluates were prepared by placing three disks into a sterile glass vial with 9 mL of Eagle's medium and incubating at 37°C for 24 hours. The cytotoxic effect from the eluates was evaluated using the 3H-thymidine incorporation and MTT assays, which reflect DNA synthesis levels and cell metabolism, respectively. Results: The components leached from the resins were cytotoxic to L929 cells when 3H- thymidine incorporation assay was employed. In contrast, eluates from all resins revealed noncytotoxic effects as measured by MTT assay. For both MTT assay and 3H-thymidine incorporation, the heat treatments did not decrease the cytotoxicity of the materials tested. Conclusion: Resins were graded by 3H-thymidine incorporation assay as slightly cytotoxic and by MTT assay as noncytotoxic. Cytotoxicity of the denture base materials was not influenced by microwave or water bath heat treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the surface roughness of four packable composite resins, SureFil™ (Dentsply, Petrópolis, Rio de Janeiro, Brazil), Prodigy Condensable™ (Kerr Co., Orange, CA, USA), Filtek P60™ (3M do Brasil, São Paulo, Brazil), and ALERT® (Jeneric/Pentron, Inc., Wallingford, CT, USA) and one microhybrid composite resin (Filtek Z250™, 3M do Brasil) after polishing with four finishing systems. Materials and Methods: Twenty specimens were made of each material (5 mm in diameter and 4 mm high) and were analyzed with a profilometer (Perthometer® S8P, Perthen, Mahr, Germany) to measure the mean surface roughness (Ra). The specimens were then divided into four groups according to the polishing system: group 1 - Sof-Lex™ (3M do Brasil), group 2 - Enhance™ (Dentsply), group 3 - Composite Finishing Kit (KG Sorensen, Barueri, São Paulo, Brazil), and group 4 - Jiffy Polisher Cups® (Ultradent Products, Inc., South Jordan, UT, USA). The specimens were polished and then evaluated for Ra, and the data were subjected to analysis of variance, analysis of covariance, and Tukey's test (p = .05). Results: The mean Ra of SureFil polished with Sof-Lex was significantly lower than that of KG points. Prodigy Condensable polished with Enhance showed a significantly less rough surface than when polished with Sof-Lex. Filtek P60 did not exhibit a significant difference with the various polishing systems. For ALERT the lowest mean Ra was obtained with Sof-Lex and the highest mean Ra with KG points. Regarding Filtek Z250, polishing with KG and Jiffy points resulted in a significantly lower mean Ra than when polished with Enhance. Conclusions: Packable composite resins display variable roughness depending on the polishing system used; the Sof-Lex disks and Jiffy points resulted in the best Ra values for the majority of the materials tested.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the influence of water bath and microwave postpolymerization treatments on the cytotoxicity of 6 hard reline acrylic resins. Materials and Methods: The materials tested were Tokuso Rebase Fast (TR), Ufi Gel Hard (UGH), Duraliner II (D), Kooliner (K), New Truliner (NT), and Light Liner (LL). LL resin was additionally tested with an air-barrier coating (LLABC). Nine disks of each material (10 × 1 mm) were made and divided into 3 groups: group 1 (no postpolymerization treatment); group 2 (postpolymerization in microwave oven); group 3 (postpolymerization in water bath at 55°C for 10 minutes). L929 cells were cultured in 96-well plates and incubated for 24 hours in Eagle's medium. Eluates prepared from the disks or medium without disks (control) replaced the medium. Cytotoxicity was assessed by both dehydrogenase succinic activity (MTT) assay and incorporation of radioactive 3H-thymidine assay. Tests were carried out in quadruplicate and repeated twice. Differences between groups were determined by analysis of variance with Tukey multiple-comparison intervals (α = .05). Results: For MTT assay, the postpolymerization treatments had no effect on the cytotoxicity of all materials (P > .05). For 3H-thymidine assay, the postpolymerization treatments significantly decreased the cytotoxicity of UGH (P < .05). The cytotoxicity of K, NT, LL, and LLABC increased after microwave irradiation (P < .05). TR, NT, and LLABC showed an increase in cytotoxicity after water bath (P < .05). Conclusion: When assessed by MTT assay, the cytotoxicity of the materials was not affected by postpolymerization treatments. 3H-Thymidine assay showed that the cytotoxicity of the resins was not improved by the postpolymerization treatments, with the exception of UGH.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tha aim of this study was to evaluate the thermocycling effect on microhardness of laboratory composite resins, 30 disks were fabricated, 5mm of diameter and 2mm of width, using 3 laboratory resins: G1 (n=10) - RESILAB MASTER (Wilcos-Brasil), G2 (n=10) - Vita VMLC (VITA Zahnfabrik-Germany), and G3 (n=10) - Vita Zeta (VITA Zahnfabrik-Germany). Vickers microhardness (HV) of all specimens was evaluated using a microhardness tester FM-700 (Future Tech- 50 g/10s). The specimens were measured before and after the thermocycling (3,000 times and 12,000 times - 5°/55°C±1). The microhardness values before cycling were (mean±SD): G1: 55.50±4.6; G2: 35.54±2.5; G3: 27.97±1.6; after 3,000 thermocycles: G1: 55.54±3.9; G2: 29.92±2.73; G3:21.01±1.4 and after 12,000 cycles G1: 54.27±3.2; G2: 30.91±1.6; G3: 23.81±0.9. Variance analysis (ANOVA) and Tukey's test was accomplished (p<0.05), the highest microhardness values were observed in G1: G2 and G3 showed reduction of microhardness values. It was concluded that, after thermocycling, the tested laboratory composites resins are susceptible to the decrease of surface microhardness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work's objectives were to isolate and evaluate the growth of the symbiotic fungus of Atta capiguara Gonçalves on artificial medium, under different pH and temperature conditions. Isolation was accomplished using the following media: Sabouraud, oat-agar, PDA, and PDA with the addition of extracts from the grasses Paspalum sp. Flügge and Hyparrhenia rufa (Nees) Stapf.. The medium used in the growth study was PDA with the addition of a Paspalum sp. (0.22%, w/v) extract at initial pH values of 4.5, 6.0, and 7.5. Mycelium disks were transferred to plates containing the culture medium. The plates were maintained at temperatures of 20, 23, and 26 ± 1°C. Mycelial radial growth evaluations were performed at 7, 14, 21, 28, and 35 days of incubation. Fungus isolation was obtained in all media studied. The highest radial means were obtained at initial pH values of 6.0 and 7.5 and temperatures of 23 and 26± 1°C. Greater plot losses occurred at the initial pH condition of 7.5. In general, A. capiguara fungi can be grown in the medium studied, at an initial pH of 6.0 and temperatures of 23 or 26± 1°C. Radial growth evaluations at 14 and 28 days of incubation can be recommended for substrate studies involving the symbiotic fungus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In practical situations, the dynamics of the forcing function on a vibrating system cannot be considered as given a priori, and it must be taken as a consequence of the dynamics of the whole system. In other words, the forcing source has limited power, as that provided by a DC motor for an example, and thus its own dynamics is influenced by that of the vibrating system being forced. This increases the number of degrees of freedom of the problem, and it is called a non-ideal problem. In this work, we considerer two non-ideal problems analyzed by using numerical simulations. The existence of the Sommerfeld effect was verified, that is, the effect of getting stuck at resonance (energy imparted to the DC motor being used to excite large amplitude motions of the supporting structure). We considered two kinds of non-ideal problem: one related to the transverse vibrations of a shaft carrying two disks and another to a piezoceramic bar transducer powered by a vacuum tube generated by a non-ideal source Copyright © 2007 by ASME.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PtFe/C nanocatalysts of different compositions and nearly constant particle size were prepared by a microemulsion method. Crystallite sizes and degree of alloying were determined by X-ray diffraction. Particle size and distribution were characterized by transmission electron microscopy and average composition was determined by energy dispersive X-ray analysis. Measurements of electrocatalytic activity for oxygen reduction were done using the rotating disk electrode technique in O2 saturated 0.5 mol L-1 sulfuric acid solutions, at room temperature. For all catalysts oxygen reduction begins at ̃ 0.90V. Tafel plots show slopes of c.a. 60 and 120 mV dec in the regions of low and high overpotentials, respectively. The best results for the ORR were obtained for the PtFe/C catalyst of composition Pt:Fe 70:30. This catalyst was also found to exhibit the largest methanol tolerance. © The Electrochemical Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effectiveness of different light-curing units on the bond strength (push-out) of glass fiber posts in the different thirds of the root (cervical, middle and apical) with different adhesive luting resin systems (dual-cure total-etch; dual-cured and self-etch bonding system; and dual-cure self-adhesive cements), Disks of the samples (n = 144) were used, with approximately 1 mm of thickness of 48 bovine roots restored with glass fiber posts, that were luted with resin cements photo-activated by halogen LCU (QTH, Optilux 501) and blue LED (Ultraled), with power densities of 600 and 550 mW/cm 2, respectively. A universal testing machine (MTS 810 Material Test System) was used with a 1 mm diameter steel rod at cross-head speed of 0.5 mm/min until post extrusion, with load cell of 50 kg, for evaluation of the push-out strength in the different thirds of each sample. The push-out strength values in kgf were converted to MPa and analyzed through Analysis of Variance and Tukey's test, at significance level of 5%. The results showed that there were no statistical differences between the QTH and LED LCUs. The self-adhesive resin cement had lower values of retention. The total-etch and self-adhesive system resin cements seem to be a possible alternative for glass fiber posts cementation into the radicular canal and the LED LCU can be applied as an alternative to halogen light on photo-activation of dual-cured resin cements. © 2009 Pleiades Publishing, Ltd.