760 resultados para body-image satisfaction


Relevância:

30.00% 30.00%

Publicador:

Resumo:

AbstractObjective:The present study is aimed at contributing to identify the most appropriate OSEM parameters to generate myocardial perfusion imaging reconstructions with the best diagnostic quality, correlating them with patients' body mass index.Materials and Methods:The present study included 28 adult patients submitted to myocardial perfusion imaging in a public hospital. The OSEM method was utilized in the images reconstruction with six different combinations of iterations and subsets numbers. The images were analyzed by nuclear cardiology specialists taking their diagnostic value into consideration and indicating the most appropriate images in terms of diagnostic quality.Results:An overall scoring analysis demonstrated that the combination of four iterations and four subsets has generated the most appropriate images in terms of diagnostic quality for all the classes of body mass index; however, the role played by the combination of six iterations and four subsets is highlighted in relation to the higher body mass index classes.Conclusion:The use of optimized parameters seems to play a relevant role in the generation of images with better diagnostic quality, ensuring the diagnosis and consequential appropriate and effective treatment for the patient.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Trough computed tomography (CT), it is possible to evaluate lymph nodes in detail and to detect changes in these structures earlier than with radiographs and ultrasound. Lack of information in the veterinary literature directed the focus of this report to normal aspects of the axillary and mediastinal lymph nodes of adult dogs on CT imaging. A CT scan of 15 normal adult male and female Rottweilers was done. To define them as clinically sound, anamnesis, physical examination, complete blood count, renal and hepatic biochemistry, ECG, and thoracic radiographs were performed. After the intravenous injection of hydrosoluble ionic iodine contrast medium contiguous 10mm in thickness thoracic transverse images were obtained with an axial scanner. In the obtained images mediastinal and axillary lymph nodes were sought and when found measured in their smallest diameter and their attenuation was compared to musculature. Mean and standard deviation of: age, weight, body length and the smallest diameter of the axillary and mediastinal lymph nodes were determined. Mean and standard deviation of parameters: age 3.87±2.03 years, weight 41.13±5.12, and body length 89.61±2.63cm. Axillary lymph nodes were seen in 60% of the animals, mean of the smallest diameter was 3.58mm with a standard deviation of 2.02 and a minimum value of 1mm and a maximum value of 7mm. From 13 observed lymph nodes 61.53% were hypopodense when compared with musculature, and 30.77% were isodense. Mediastinal lymph nodes were identified in 73.33% of the dogs; mean measure of the smallest diameter was 4.71mm with a standard deviation of 2.61mm and a minimum value of 1mm, and a maximum value of 8mm. From 14 observed lymph nodes 85.71% were isodense when compared with musculature and 14.28% were hypodense. The results show that it is possible to visualize axillary and mediastinal lymph nodes in adult clinically sound Rottweilers with CT using a slice thickness and interval of 10mm. The smallest diameter of the axillary and mediastinal lymph nodes not surpassed 7mm and 8mm respectively. Their attenuations were equal or smaller than that of musculature in the post contrast scan.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The carotid bodies from adult spontaneous insulin-dependent diabetic rats (strain BB/S) were perfusion-fixed at normal arterial blood pressure with 3% phosphate-buffered glutaraldehyde and compared with the organs from control rats (strain BB/Sc) prepared in the same way. Serial 5-µm sections were cut, stained, and using an interactive image analysis system, were analysed to determine the volumes of the carotid body and its vascular and extravascular compartments. There was no evidence of systemic arterial disease in the carotid stem arteries in either group of animals, and the microvasculature of the organs appeared normal by light microscopy. The volume of the carotid body was unchanged 3 months after the onset of diabetes but was increased at 6 months. The total vascular volume of the organ was unchanged, but the volume of the small vessels (5-12 µm) was increased. In the control group the small vessels comprised 5% of the total volume of the carotid body, or about 44% of the vascular compartment. The percentage of small vessels increased at 3 months in the diabetic group, but had returned to normal at 6 months. The extravascular volume followed the same pattern as the total carotid body volume and so did not change appreciably when expressed as a percentage of the total volume of the organ. The increase in size of the carotid body in diabetic rats is due, therefore, to an augmented extravascular volume. In one diabetic specimen the carotid sinus nerve showed signs of diabetic neuropathy, axonal swelling and intramyelinic oedema. The clinical implications of these results are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The carotid bodies of rats made chronically hypoxic by breathing 12% O2 in a normobaric chamber (inspired PO2 91 mmHg) were compared with those of controls. Serial 5-µm sections of the organs were examined using an interactive image analysis system. The total volume of the carotid bodies was increased by 64%. The total vascular volume rose by 103% and was likely due to an increase in size of the large vessels (>12 µm lumen diameter) because the small vessel (5-12 µm lumen diameter) volume did not increase significantly while the small vessel density tended to decrease. The extravascular volume was increased by 57%. Expressed as a percentage of the total volume of the organ, the total vascular volume did not change, but the small vessel volume was significantly decreased from 7.83 to 6.06%. The large vessel volume must therefore have been increased. The proportion occupied by the extravascular volume was virtually unchanged (84 vs 82%). In accordance with these findings, the small vessel endothelial surface area per unit carotid body volume was diminished from 95.2 to 76.5 mm-1, while the extravascular area per small vessel was increased from 493 to 641 µm2 or by 30%. In conclusion, the enlargement of the carotid body in chronic hypoxia is most likely due to an increase in total vascular volume, mainly involving the "large" vessels, and to an increase in extravascular volume. This is in contrast to our previously published findings indicating that in the spontaneous insulin-dependent diabetic rat the enlargement of the carotid body is due solely to an increase in extravascular volume.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present study was to measure full epidermal thickness, stratum corneum thickness, rete length, dermal papilla widening and suprapapillary epidermal thickness in psoriasis patients using a light microscope and computer-supported image analysis. The data obtained were analyzed in terms of patient age, type of psoriasis, total body surface area involvement, scalp and nail involvement, duration of psoriasis, and family history of the disease. The study was conducted on 64 patients and 57 controls whose skin biopsies were examined by light microscopy. The acquired microscopic images were transferred to a computer and measurements were made using image analysis. The skin biopsies, taken from different body areas, were examined for different parameters such as epidermal, corneal and suprapapillary epidermal thickness. The most prominent increase in thickness was detected in the palmar region. Corneal thickness was more pronounced in patients with scalp involvement than in patients without scalp involvement (t = -2.651, P = 0.008). The most prominent increase in rete length was observed in the knees (median: 491 µm, t = 10.117, P = 0.000). The difference in rete length between patients with a positive and a negative family history was significant (t = -3.334, P = 0.03), being 27% greater in psoriasis patients without a family history. The differences in dermal papilla distances among patients were very small. We conclude that microscope-supported thickness measurements provide objective results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this Master’s thesis is to study sponsor satisfaction in charity sport events. Lack of research in regional charity sport events, emergence of corporate social responsibility and increasing popularity of charity sport events have created a research gap to be further explored. Theoretical part of the thesis focuses in development of sponsorships, charity sport event sponsorships and sponsorship as a marketing tool. Concept of satisfaction is discussed by implementing marketing theories to weight options on measuring sponsor satisfaction as a part of sponsorship evaluation process. Empirical analysis of the thesis was conducted in a regional charity sport event – Maailman Pisin Salibandyottelu. Evidences were collected in qualitative research method through semi-structured theme interviews. Altogether 12 major and minor sponsors were selected for the primary source of data. The data was analyzed by comparing sponsors’ expectations and experiences, and by displaying sponsors’ perceived satisfaction. The results indicated that sponsors were involved by partly altruistic and partly selfish motives as suggested by previous research. Respondents expressed very few, mainly non-financial expectations, yet were hoping to gain positive image association via event exposure. Negative experiences appear to have relatively small impact in overall satisfaction. Exceeding or fulfilling expectations appears to increase perceived satisfaction which was mainly driven by contribution towards the goodwill, perceived success of the event (successful record attempt, visibility (on- and off-line) and event execution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

X-ray computed log tomography has always been applied for qualitative reconstructions. In most cases, a series of consecutive slices of the timber are scanned to estimate the 3D image reconstruction of the entire log. However, the unexpected movement of the timber under study influences the quality of image reconstruction since the position and orientation of some scanned slices can be incorrectly estimated. In addition, the reconstruction time remains a significant challenge for practical applications. The present study investigates the possibility to employ modern physics engines for the problem of estimating the position of a moving rigid body and its scanned slices which are subject to X-ray computed tomography. The current work includes implementations of the extended Kalman filter and an algebraic reconstruction method for fan-bean computer tomography. In addition, modern techniques such as NVidia PhysX and CUDA are used in current study. As the result, it is numerically shown that it is possible to apply the extended Kalman filter together with a real-time physics engine, known as PhysX, in order to determine the position of a moving object. It is shown that the position of the rigid body can be determined based only on reconstructions of its slices. However, the simulation of the body movement sometimes is subject to an error during Kalman filter employment as PhysX is not always able to continue simulating the movement properly because of incorrect state estimation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Black and white photograph, mounted on board, 18 ½ cm. x 23 ½ cm. of the G.G.B.G. [Governor General’s Body Guard] on horseback at Camp Niagara.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Black and white photograph, mounted on board, 13 cm x 20 cm of the B Squadron of the G.G.B.G. [Governor General’s Body Guard] at Niagara.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dans ce mémoire, nous étudions la représentation du corps dans Aveux non avenus de Claude Cahun. Évoquant dans un premier temps quelques grands axes de l’histoire de la réflexion sur le corps et de sa représentation en Occident depuis l’Antiquité, en fonction de leur fécondité pour l’analyse de l’oeuvre de Cahun, nous procédons dans un deuxième temps à une analyse de la représentation du corps dans les fragments de texte qui composent Aveux non avenus, en insistant d’une part sur le rapport ambivalent au corps qui y est exprimé et d’autre part sur la relation étroite qui lie le corps à la problématique identitaire, centrale dans tout l’oeuvre cahunien. Nous étudions ensuite la façon dont le corps est représenté, en nous intéressant à l’écriture particulière que déploie Cahun dans les Aveux ainsi qu’à la démarche intermédiale qu’elle met en place à travers la présence des photomontages au sein du texte. Nous souhaitons ainsi démontrer que la représentation du corps est indissociable d’une réflexion sur l’identité et que le caractère double de cette représentation à travers le texte et l’image complexifie cette réflexion sans lui enlever sa cohérence.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The registration of pre-operative volumetric datasets to intra- operative two-dimensional images provides an improved way of verifying patient position and medical instrument loca- tion. In applications from orthopedics to neurosurgery, it has a great value in maintaining up-to-date information about changes due to intervention. We propose a mutual information- based registration algorithm to establish the proper align- ment. For optimization purposes, we compare the perfor- mance of the non-gradient Powell method and two slightly di erent versions of a stochastic gradient ascent strategy: one using a sparsely sampled histogramming approach and the other Parzen windowing to carry out probability density approximation. Our main contribution lies in adopting the stochastic ap- proximation scheme successfully applied in 3D-3D registra- tion problems to the 2D-3D scenario, which obviates the need for the generation of full DRRs at each iteration of pose op- timization. This facilitates a considerable savings in compu- tation expense. We also introduce a new probability density estimator for image intensities via sparse histogramming, de- rive gradient estimates for the density measures required by the maximization procedure and introduce the framework for a multiresolution strategy to the problem. Registration results are presented on uoroscopy and CT datasets of a plastic pelvis and a real skull, and on a high-resolution CT- derived simulated dataset of a real skull, a plastic skull, a plastic pelvis and a plastic lumbar spine segment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a statistical image-based shape + structure model for Bayesian visual hull reconstruction and 3D structure inference. The 3D shape of a class of objects is represented by sets of contours from silhouette views simultaneously observed from multiple calibrated cameras. Bayesian reconstructions of new shapes are then estimated using a prior density constructed with a mixture model and probabilistic principal components analysis. We show how the use of a class-specific prior in a visual hull reconstruction can reduce the effect of segmentation errors from the silhouette extraction process. The proposed method is applied to a data set of pedestrian images, and improvements in the approximate 3D models under various noise conditions are shown. We further augment the shape model to incorporate structural features of interest; unknown structural parameters for a novel set of contours are then inferred via the Bayesian reconstruction process. Model matching and parameter inference are done entirely in the image domain and require no explicit 3D construction. Our shape model enables accurate estimation of structure despite segmentation errors or missing views in the input silhouettes, and works even with only a single input view. Using a data set of thousands of pedestrian images generated from a synthetic model, we can accurately infer the 3D locations of 19 joints on the body based on observed silhouette contours from real images.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Customer satisfaction and retention are key issues for organizations in today’s competitive market place. As such, much research and revenue has been invested in developing accurate ways of assessing consumer satisfaction at both the macro (national) and micro (organizational) level, facilitating comparisons in performance both within and between industries. Since the instigation of the national customer satisfaction indices (CSI), partial least squares (PLS) has been used to estimate the CSI models in preference to structural equation models (SEM) because they do not rely on strict assumptions about the data. However, this choice was based upon some misconceptions about the use of SEM’s and does not take into consideration more recent advances in SEM, including estimation methods that are robust to non-normality and missing data. In this paper, both SEM and PLS approaches were compared by evaluating perceptions of the Isle of Man Post Office Products and Customer service using a CSI format. The new robust SEM procedures were found to be advantageous over PLS. Product quality was found to be the only driver of customer satisfaction, while image and satisfaction were the only predictors of loyalty, thus arguing for the specificity of postal services

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A set of images which can be used within the University for teaching students.