905 resultados para block trade
Resumo:
INTRODUCTION: Mitral isthmus (MI) ablation is an effective option in patients undergoing ablation for persistent atrial fibrillation (AF). Achieving bidirectional conduction block across the MI is challenging, and predictors of MI ablation success remain incompletely understood. We sought to determine the impact of anatomical location of the ablation line on the efficacy of MI ablation. METHODS AND RESULTS: A total of 40 consecutive patients (87% male; 54 ± 10 years) undergoing stepwise AF ablation were included. MI ablation was performed in sinus rhythm. MI ablation was performed from the left inferior PV to either the posterior (group 1) or the anterolateral (group 2) mitral annulus depending on randomization. The length of the MI line (measured with the 3D mapping system) and the amplitude of the EGMs at 3 positions on the MI were measured in each patient. MI block was achieved in 14/19 (74%) patients in group 1 and 15/21 (71%) patients in group 2 (P = NS). Total MI radiofrequency time (18 ± 7 min vs. 17 ± 8 min; P = NS) was similar between groups. Patients with incomplete MI block had a longer MI length (34 ± 6 mm vs. 24 ± 5 mm; P < 0.001), a higher bipolar voltage along the MI (1.75 ± 0.74 mV vs. 1.05 ± 0.69 mV; P < 0.01), and a longer history of continuous AF (19 ± 17 months vs. 10 ± 10 months; P < 0.05). In multivariate analysis, decreased length of the MI was an independent predictor of successful MI block (OR 1.5; 95% CI 1.1-2.1; P < 0.05). CONCLUSIONS: Increased length but not anatomical location of the MI predicts failure to achieve bidirectional MI block during ablation of persistent AF.
Resumo:
Objectives: The purpose of this study is to determine the possible differences in deflection between two needles of same length and external gauge but with different internal gauges during truncal block of the inferior alveolar nerve. The initial working hypothesis was that greater deflection may be expected with larger internal gauge needles. Study design: Four clinicians subjected 346 patients to inferior alveolar nerve block and infiltrating anesthesia of the buccal nerve trajectory for the surgical or conventional extraction of the lower third molar. A nonautoaspirating syringe system with 2 types of needle was used: a standard 27-gauge x 35-mm needle with an internal gauge of 0.215 mm or an XL Monoprotect® 27-gauge x 35-mm needle with an internal gauge of 0.265 mm. The following information was systematically recorded for each patient: needle type, gender, anesthetic technique (direct or indirect truncal block) and the number of bone contacts during the procedure, the patient-extraction side, the practitioner performing the technique, and blood aspiration (either positive or negative). Results: 346 needles were used in total. 190 were standard needles (27-gauge x 35-mm needle with an internal gauge of 0.215 mm) and 156 were XL Monoprotect®. Incidence of deflection was observed in 49.1% of cases (170 needles) where 94 were standard needles and 76 XL Monoprotect®. Needle torsion ranged from 0º and 6º. Conclusions: No significant differences were recorded in terms of deflection and internal gauge, operator, patient-extraction side, the anesthetic technique involved and the number of bone contacts during the procedure
Resumo:
O Breast Imaging Reporting and Data System (BI-RADS™), do American College of hRadiology, foi concebido para padronizar o laudo mamográfico e reduzir os fatores de confusão na descrição e interpretação das imagens, além de facilitar o monitoramento do resultado final. OBJETIVO: Identificar a maneira como vem sendo utilizado o BI-RADS™, gerando informações que possam auxiliar o Colégio Brasileiro de Radiologia a desenvolver estratégias para aperfeiçoar o seu uso. MATERIAIS E MÉTODOS: Os dados foram coletados na cidade de Goiânia, GO. Foram solicitados os exames de mamografia anteriores a todas as mulheres que se dirigiram ao serviço para realização de mamografia entre janeiro/2003 e junho/2003. Foram incluídos na análise exames anteriores, realizados entre 1/7/2001 e 30/6/2003. RESULTADOS: Foram coletados 104 laudos anteriores, emitidos por 40 radiologistas de 33 diferentes serviços. Dos 104 laudos, 77% (n = 80) utilizavam o BI-RADS™. Destes, apenas 15% (n = 12) eram concisos, nenhum utilizava a estrutura e organização recomendadas pelo sistema, 98,75% (n = 79) não respeitavam o léxico e 65% (n = 51) não faziam recomendação de conduta. CONCLUSÃO: O BI-RADS™, apesar de bastante utilizado, não foi reconhecido como sistema para padronização dos laudos. Foi usado quase exclusivamente como forma de classificação final dos exames.
Resumo:
The thesis is made of three independent chapters interested in the impact of globalization on workers in industrialized countries. The dissertation is especially focused on identifying the causal impact of international trade on workers' mobility, wages, and employment with both a short- and medium-term perspective. The first paper explores the relation between intra-industry trade (IIT) expansion and associated worker flows, taking the latter as an indicator of labor-market adjustment costs. Being the first study to combine theoretical simulations and a novel identification strategy, we find that both theoretical and empirical analyses are consistent with the "smooth adjustment hypothesis", according to which IIT expansion is less disruptive than inter-industry trade expansion. The study therefore lends support to the use of IIT indices as first-pass proxies for the adjustment effects of trade expansion. The second chapter contrasts the impact of increased import competition coming from China and the European Union (EU) on workers in the United Kingdom over a 15-year period. The most salient findings show that increased imports from China had significantly negative effects on workers' earnings, wages and employment. In contrast, larger imports from the EU are associated with positive worker-level outcomes, which is largely explained by the fact that increased imports from the EU were mostly offset by increased same-industry exports to the EU. Besides, we find that increased imports from China exert additional pressure on workers through spillovers to employment and wages in downstream industries. Finally, the last chapter is focused on the impact of exposure to trade and real exchange rate shocks on wages for Swiss manufacturing workers. A particular attention is made to consistently estimate the causal effect in using a two-step gravity-type identification strategy. The study shows that the impact of trade and exchange rate movements is concentrated among high-skilled workers almost exclusively.
Resumo:
Globalisation and technological advances have made possible to offshore specific productive tasks (that do not require physical proximity to the actual location of the work unit) to foreign countries where these are usually performed at lower costs. We analyse the effect of task trade (i.e. task offshorability) on Spanish regional and national employment levels correlating a newly built index of task-delocalisation index to key variables such as the region’s wealth, the worker’s age and level of education, the importance of the service sector and the technological level of the economic activities undertaken in that particular geographical area. We conclude that approximately 25 per cent of Spanish occupations are potentially affected by task trade / offshoring and that this is likely to benefit Spanish economy (and the performance of specific regions, categories of workers and sectors) being Spain a potential recipient of tasks offshored from abroad. Also we obtain that Spain’s trade in tasks correlates strongly with the above variables, presenting significant regional differences.
Resumo:
Newly generated olfactory receptor axons grow from the peripheral to the central nervous system aided by olfactory ensheathing cells (OECs). Thus, OEC transplantation has emerged as a promising therapy for spinal cord injuries and for other neural diseases. However, these cells do not present a uniform population, but, instead, a functionally heterogeneous population that exhibits a variety of responses including adhesion, repulsion and crossover during cell-cell and cell-matrix interactions. Some studies report that the migratory properties of OECs are compromised by inhibitory molecules and potentiated by chemical gradients. Here, we demonstrated that rodent OECs express all the components of the Nogo Receptor complex and that their migration is blocked by Myelin. Next, we used cell tracking and traction force microscopy to analyze OEC migration and its mechanical properties over Myelin. Our data relate the absence of traction force of OEC with lower migratory capacity, which correlates with changes in the F-Actin cytoskeleton and focal adhesion distribution. Lastly, OEC traction force and migratory capacity is enhanced after cell incubation with the Nogo Receptor inhibitor NEP1-40.
Resumo:
Differences in parasite transmission intensity influence the process of acquisition of host immunity to Plasmodium falciparum malaria and ultimately, the rate of malaria related morbidity and mortality. Potential vaccines being designed to complement current intervention efforts therefore need to be evaluated against different malaria endemicity backgrounds. The associations between antibody responses to the chimeric merozoite surface protein 1 block 2 hybrid (MSP1 hybrid), glutamate-rich protein region 2 (GLURP R2) and the peptide AS202.11, and the risk of malaria were assessed in children living in malaria hyperendemic (Burkina Faso, n = 354) and hypo-endemic (Ghana, n = 209) areas. Using the same reagent lots and standardized protocols for both study sites, immunoglobulin (Ig) M, IgG and IgG sub-class levels to each antigen were measured by ELISA in plasma from the children (aged 6-72 months). Associations between antibody levels and risk of malaria were assessed using Cox regression models adjusting for covariates. There was a significant association between GLURP R2 IgG3 and reduced risk of malaria after adjusting age of children in both the Burkinabe (hazard ratio 0.82; 95 % CI 0.74-0.91, p < 0.0001) and the Ghanaian (HR 0.48; 95 % CI 0.25-0.91, p = 0.02) cohorts. MSP1 hybrid IgM was associated (HR 0.85; 95 % CI 0.73-0.98, p = 0.02) with reduced risk of malaria in Burkina Faso cohort while IgG against AS202.11 in the Ghanaian children was associated with increased risk of malaria (HR 1.29; 95 % CI 1.01-1.65, p = 0.04). These findings support further development of GLURP R2 and MSP1 block 2 hybrid, perhaps as a fusion vaccine antigen targeting malaria blood stage that can be deployed in areas of varying transmission intensity.
Resumo:
BACKGROUND: Hemidiaphragmatic paresis after ultrasound-guided interscalene brachial plexus block is reported to occur in up to 100% of patients. We tested the hypothesis that an injection lateral to the brachial plexus sheath reduces the incidence of hemidiaphragmatic paresis compared with a conventional intrafascial injection, while providing similar analgesia. METHODS: Forty ASA I-III patients undergoing elective shoulder and clavicle surgery under general anaesthesia were randomized to receive an ultrasound-guided interscalene brachial plexus block for analgesia, using 20 ml bupivacaine 0.5% with epinephrine 1:200 000 injected either between C5 and C6 within the interscalene groove (conventional intrafascial injection), or 4 mm lateral to the brachial plexus sheath (extrafascial injection). The primary outcome was incidence of hemidiaphragmatic paresis (diaphragmatic excursion reduction >75%), measured by M-mode ultrasonography, before and 30 min after the procedure. Secondary outcomes were forced vital capacity, forced expiratory volume in 1 s, and peak expiratory flow. Additional outcomes included time to first opioid request and pain scores at 24 h postoperatively (numeric rating scale, 0-10). RESULTS: The incidences of hemidiaphragmatic paresis were 90% (95% CI: 68-99%) and 21% (95% CI: 6-46%) in the conventional and extrafascial injection groups, respectively (P<0.0001). Other respiratory outcomes were significantly better preserved in the extrafascial injection group. The mean time to first opioid request was similar between groups (conventional: 802 min [95% CI: 620-984 min]; extrafascial: 973 min [95% CI: 791-1155 min]; P=0.19) as were pain scores at 24 h postoperatively (conventional: 1.6 [95% CI: 0.9-2.2]; extrafascial: 1.6 [95% CI: 0.8-2.4]; P=0.97). CONCLUSIONS: Ultrasound-guided interscalene brachial plexus block with an extrafascial injection reduces the incidence of hemidiaphragmatic paresis and impact on respiratory function while providing similar analgesia, when compared with a conventional injection. CLINICAL TRIAL REGISTRATION: NCT02074397.
Resumo:
Objective: To analyze anatomical variations associated with celiac plexus complex by means of computed tomography simulation, assessing the risk for organ injury as the transcrural technique is utilized. Materials and Methods: One hundred eight transaxial computed tomography images of abdomen were analyzed. The aortic-vertebral, celiac trunk (CeT)-vertebral, CeT-aortic and celiac-aortic-vertebral topographical relationships were recorded. Two needle insertion pathways were drawn on each of the images, at right and left, 9 cm and 4.5 cm away from the midline. Transfixed vital organs and gender-related associations were recorded. Results: Aortic-vertebral - 45.37% at left and 54.62% in the middle; CeT-vertebral - T12, 36.11%; T12-L1, 32.4%; L1, 27.77%; T11-T12, 2.77%; CeT-aortic - 53.7% at left and 46.3% in the middle; celiac-aortic-vertebral - L-l, 22.22%; M-m, 23.15%; L-m, 31.48%; M-l, 23.15%. Neither correspondence on the right side nor significant gender-related associations were observed. Conclusion: Considering the wide range of abdominal anatomical variations and the characteristics of needle insertion pathways, celiac plexus block should not be standardized. Imaging should be performed prior to the procedure in order to reduce the risks for injuries or for negative outcomes to patients. Gender-related anatomical variations involved in celiac plexus block should be more deeply investigated, since few studies have addressed the subject.
Resumo:
Introduction : Le bloc transverse de l'abdomen (bloc TAP, Transversus Abdominis Plane) échoguidé consiste en l'injection d'anesthésique local dans la paroi abdominale entre les muscles oblique interne et transverse de l'abdomen sous contrôle échographique. Ceci permet de bloquer l'innervation sensitive de la paroi antérolatérale de l'abdomen afin de soulager la douleur après des interventions chirurgicales. Auparavant, cette procédure reposait sur une technique dite « à l'aveugle » qui utilisait des repères anatomiques de surface. Depuis quelques années, cette technique est effectuée sous guidage échographique ; ainsi, il est possible de visualiser les structures anatomiques, l'aiguille et l'anesthésique local permettant ainsi une injection précise de l'anesthésique local à l'endroit désiré. Les précédentes méta- analyses sur le bloc TAP n'ont inclus qu'un nombre limité d'articles et n'ont pas examiné l'effet analgésique spécifique de la technique échoguidée. L'objectif de cette méta-analyse est donc de définir l'efficacité analgésique propre du bloc TAP échoguidé après des interventions abdominales chez une population adulte. Méthode : Cette méta-analyse a été effectuée selon les recommandations PRISMA. Une recherche a été effectuée dans les bases de donnée MEDLINE, Cochrane Central Register of Controlled Clinical Trials, Excerpta Medica database (EMBASE) et Cumulative Index to Nursing and Allied Health Literature (CINAHL). Le critère de jugement principal est la consommation intraveineuse de morphine cumulée à 6 h postopératoires, analysée selon le type de chirurgie (laparotomie, laparoscopie, césarienne), la technique anesthésique (anesthésie générale, anesthésie spinale avec/ou sans morphine intrathécale), le moment de l'injection (début ou fin de l'intervention), et la présence ou non d'une analgésie multimodale. Les critères de jugement secondaires sont, entre autres, les scores de douleur au repos et à l'effort à 6 h postopératoires (échelle analogique de 0 à 100), la présence ou non de nausées et vomissements postopératoires, la présence ou non de prurit, et le taux de complications de la technique. Résultats : Trente et une études randomisées contrôlées, incluant un total de 1611 adultes ont été incluses. Indépendamment du type de chirurgie, le bloc TAP échoguidé réduit la consommation de morphine à 6 h postopératoires (différence moyenne : 6 mg ; 95%IC : -7, -4 mg ; I =94% ; p<0.00001), sauf si les patients sont au bénéfice d'une anesthésie spinale avec morphine intrathécale. Le degré de réduction de consommation de morphine n'est pas influencé par le moment de l'injection (I2=0% ; p=0.72) ou la présence d'une analgésie multimodale (I2=73% ; p=0.05). Les scores de douleurs au repos et à l'effort à 6h postopératoire sont également réduits (différence moyenne au repos : -10 ; 95%IC : -15, -5 ; I =92% ; p=0.0002; différence moyenne en mouvement : -9 ; 95%IC : -14, -5 ; I2=58% ; p<0. 00001). Aucune différence n'a été retrouvée au niveau des nausées et vomissements postopératoires et du prurit. Deux complications mineures ont été identifiées (1 hématome, 1 réaction anaphylactoïde sur 1028 patients). Conclusions : Le bloc TAP échoguidé procure une analgésie postopératoire mineure et ne présente aucun bénéfice chez les patients ayant reçu de la morphine intrathécale. L'effet analgésique mineure est indépendant du moment de l'injection ou de la présence ou non d'une analgésie multimodale.
Resumo:
This study considered the current situation of biofuels markets in Finland. The fact that industry consumes more than half of the total primary energy, widely applied combined heat and power production and a high share of solid biomass fuels in the total energy consumption are specific to the Finnish energy system. Wood is the most important source of bioenergy in Finland, representing 21% of the total energy consumption in 2006. Almost 80% of the wood-based energy is recovered from industrial by-products and residues. Finland has commitment itself to maintaining its greenhouse gas emissions at the 1990 level, at the highest, during the period 2008–2012. The energy and climate policy carried out in recent years has been based on the National Energy and Climate introduced in 2005. The Finnish energy policy aims to achieve the target, and a variety of measures are taken to promote the use of renewable energy sources and especially wood fuels. In 2007, the government started to prepare a new long-term (up to the year 2050) climate and energy strategy that will meet EU’s new targets for the reduction of green house gas emissions and the promotion of renewable energy sources. The new strategy will be introduced during 2008. The international biofuels trade has a substantial importance for the utilisation of bioenergy in Finland. In 2006, the total international trading of solid and liquid biofuels was approximately 64 PJ of which import was 61 PJ. Most of the import is indirect and takes place within the forest industry’s raw wood imports. In 2006, as much as 24% of wood energy was based on foreignorigin wood. Wood pellets and tall oil form the majority of export streams of biofuels. The indirect import of wood fuels increased almost 10% in 2004–2006, while the direct trade of solid and liquid biofuels has been almost constant.