954 resultados para WASTE-WATER TREATMENT
Resumo:
The lack of access to sufficient water and sanitation facilities is one of the largest hindrances towards the sustainable development of the poorest 2.2 billion people in the world. Rural Uganda is one of the areas where such inaccessibility is seriously hampering their efforts at development. Many rural Ugandans must travel several kilometers to fetch adequate water and many still do not have adequate sanitation facilities. Such poor access to clean water forces Ugandans to spend an inordinate amount of time and energy collecting water - time and energy that could be used for more useful endeavors. Furthermore, the difficulty in getting water means that people use less water than they need to for optimal health and well-being. Access to other sanitation facilities can also have a large impact, particularly on the health of young children and the elderly whose immune systems are less than optimal. Hand-washing, presence of a sanitary latrine, general household cleanliness, maintenance of the safe water chain and the households’ knowledge about and adherence to sound sanitation practices may be as important as access to clean water sources. This report investigates these problems using the results from two different studies. It first looks into how access to water affects peoples’ use of it. In particular it investigates how much water households use as a function of perceived effort to fetch it. Operationally, this was accomplished by surveying nearly 1,500 residents in three different districts around Uganda about their water usage and the time and distance they must travel to fetch it. The study found that there is no statistically significant correlation between a family’s water usage and the perceived effort they must put forth to have to fetch it. On average, people use around 15 liters per person per day. Rural Ugandan residents apparently require a certain amount of water and will travel as far or as long as necessary to collect it. Secondly, a study entitled “What Works Best in Diarrheal Disease Prevention?” was carried out to study the effectiveness of five different water and sanitation facilities in reducing diarrheal disease incidences amongst children under five. It did this by surveying five different communities before and after the implementation of improvements to find changes in diarrheal disease incidences amongst children under five years of age. It found that household water treatment devices provide the best means of preventing diarrheal diseases. This is likely because water often becomes contaminated before it is consumed even if it was collected from a protected source.
Resumo:
Two groundwater bodies, Grazer Feld and Leibnitzer Feld, with surface areas of 166 and 103 km2 respectively are characterised for the first time by measuring the combination of d18O/d2H, 3H/3He, 85Kr, CFC-11, CFC-12 and hydrochemistry in 34 monitoring wells in 2009/2010. The timescales of groundwater recharge have been characterised by 131 d18O measurements of well and surface water sampled on a seasonal basis. Most monitoring wells show a seasonal variation or indicate variable contributions of the main river Mur (0–30%, max. 70%) and/or other rivers having their recharge areas in higher altitudes. Combined d18O/d2H-measurements indicate that 65–75% of groundwater recharge in the unusual wet year of 2009 was from precipitation in the summer based on values from the Graz meteorological station. Monitoring wells downstream of gravel pit lakes show a clear evaporation trend. A boron–nitrate differentiation plot shows more frequent boron-rich water in the more urbanised Grazer Feld and more frequent nitrate-rich water in the more agricultural used Leibnitzer Feld indicating that a some of the nitrate load in the Grazer Feld comes from urban sewer water. Several lumped parameter models based on tritium input data from Graz and monthly data from the river Mur (Spielfeld) since 1977 yield a Mean Residence Time (MRT) for the Mur-water itself between 3 and 4 years in this area. Data from d18O, 3H/3He measurements at the Wagna lysimeter station supports the conclusion that 90% of the groundwaters in the Grazer Feld and 73% in the Leibnitzer Feld have MRTs of <5 years. Only in a few groundwaters were MRTs of 6–10 or 11–25 years as a result of either a long-distance water inflow in the basins or due to longer flow path in somewhat deeper wells (>20 m) with relative thicker unsaturated zones. The young MRT of groundwater from two monitoring wells in the Leibnitzer Feld was confirmed by 85Kr-measurements. Most CFC-11 and CFC-12 concentrations in the groundwater exceed the equilibration concentrations of modern concentrations in water and are therefore unsuitable for dating purposes. An enrichment factor up to 100 compared to atmospheric equilibrium concentrations and the obvious correlation of CFC-12 with SO4, Na, Cl and B in the ground waters of the Grazer Feld suggest that waste water in contact with CFC-containing material above and below ground is the source for the contamination. The dominance of very young groundwater (<5 years) indicates a recent origin of the contamination by nitrate and many other components observed in parts of the groundwater bodies. Rapid measures to reduce those sources are needed to mitigate against further deterioration of these waters.
Resumo:
Developing countries are heavily burdened by limited access to safe drinking water and subsequent water-related diseases. Numerous water treatment interventions combat this public health crisis, encompassing both traditional and less-common methods. Of these, water disinfection serves as an important means to provide safe drinking water. Existing literature discusses a wide range of traditional treatment options and encourages the use of multi-barrier approaches including coagulation-flocculation, filtration, and disinfection. Most sources do not delve into approaches specifically appropriate for developing countries, nor do they exclusively examine water disinfection methods.^ The objective of this review is to focus on an extensive range of chemical, physio-chemical, and physical water disinfection techniques to provide a compilation, description and evaluation of options available. Such an objective provides further understanding and knowledge to better inform water treatment interventions and explores alternate means of water disinfection appropriate for developing countries. Appropriateness for developing countries corresponds to the effectiveness of an available, easy to use disinfection technique at providing safe drinking water at a low cost.^ Among chemical disinfectants, SWS sodium hypochlorite solution is preferred over sodium hypochlorite bleach due to consistent concentrations. Tablet forms are highly recommended chemical disinfectants because they are effective and very easy to use, but also because they are stable. Examples include sodium dichloroisocyanurate, calcium hypochlorite, and chlorine dioxide, which vary in cost depending on location and availability. Among physio-chemical disinfection options, electrolysis which produces mixed oxidants (MIOX) provides a highly effective disinfection option with a higher upfront cost but very low cost over the long term. Among physical disinfection options, solar disinfection (SODIS) applications are effective, but they treat only a fixed volume of water at a time. They come with higher initial costs but very low on-going costs. Additional effective disinfection techniques may be suitable depending on the location, availability and cost.^
Resumo:
Ocean acidification (OA) is expected to drive the transition of coral reef ecosystems from net calcium carbonate (CaCO3) precipitating to net dissolving within the next century. Although permeable sediments represent the largest reservoir of CaCO3 in coral reefs, the dissolution of shallow CaCO3 sands under future pCO2 levels has not been measured under natural conditions. In situ, advective chamber incubations under elevated pCO2 (~800 µatm) shifted the sediments from net precipitating to net dissolving. Pore water advection more than doubled dissolution rates (1.10 g CaCO3/m**2/day) when compared to diffusive conditions (0.42 g CaCO3/m**2 /day). Sediment dissolution could reduce net ecosystem calcification rates of the Heron Island lagoon by 8% within the next century, which is equivalent to a 25% reduction in the global average calcification rate of coral lagoons. The dissolution of CaCO3 sediments needs to be taken into account in order to address how OA will impact the net accretion of coral reefs under future predicted increases in CO2.
Resumo:
Charophytes are found in fresh and brackish waters across the globe and play key roles in coastal ecosystems. However, their response to increasing CO2 is not well understood. The aim of the study was to detect the effects of elevated CO2 on the physiology of charophyte species growing in the brackish Baltic Sea by measuring net primary production. Mesocosm experiments were conducted in the Kõiguste Bay (N Gulf of Riga) during the field season of 2012. Separate mesocosms were maintained at different pCO2 levels: 2000, 1000 and 200 µatm. The experiments were carried out with three species of charophytes: Chara aspera, C. tomentosa and C. horrida. The short-term photosynthetic responses of charophytes to different treatments were measured by the oxygen method. The results show that elevated CO2 levels in brackish water may enhance the photosynthetic activity of charophyte species and suggest that increasing CO2 in the Baltic Sea could have implications for interspecific competition and community structure in a future high CO2 world.
Resumo:
Aquaponics is the science of integrating intensive fish aquaculture with plant production in recirculating water systems. Although ion waste production by fish cannot satisfy all plant requirements, less is known about the relationship between total feed provided for fish and the production of milliequivalents (mEq) of different macronutrients for plants, especially for nutrient flow hydroponics used for strawberry production in Spain. That knowledge is essential to consider the amount of macronutrients available in aquaculture systems so that farmers can estimate how much nutrient needs to be supplemented in the waste water from fish, to produce viable plant growth. In the present experiment, tilapia (Oreochromis niloticus L.) were grown in a small-scale recirculating system at two different densities while growth and feed consumption were noted every week for five weeks. At the same time points, water samples were taken to measure pH, EC25, HCO3 – , Cl – , NH4 + , NO2 – , NO3 – , H2PO4 – , SO4 2– , Na + , K+ , Ca 2+ and Mg 2+ build up. The total increase in mEq of each ion per kg of feed provided to the fish was highest for NO3 - , followed, in decreasing order, by Ca 2+ , H2PO4 – , K+ , Mg 2+ and SO4 2– . The total amount of feed required per mEq ranged from 1.61- 13.1 kg for the four most abundant ions (NO3 – , Ca 2+ , H2PO4 – and K+ ) at a density of 2 kg fish m–3 , suggesting that it would be rather easy to maintain small populations of fish to reduce the cost of hydroponic solution supplementation for strawberries.
Resumo:
En este trabajo, se han llevado a cabo distintos experimentos en laboratorio, con el objetivo de estudiar el efecto de la aplicación de residuos orgánicos como fuentes de P en las pérdidas de este elemento, que se producen en suelo, tanto por escorrentía superficial como por lixiviación. El interés por evaluar las pérdidas de P se debe a la necesidad de conocer mejor los factores que influyen en los procesos de pérdidas de este elemento y así, poder reducir los problemas de eutrofización de aguas, tanto superficiales como subterráneas, provocadas por un exceso de este nutriente, junto con otros como el nitrógeno. Los trabajos experimentales que se han llevado a cabo se detallan a continuación: Se ha realizado el estudio de las formas de P contenidas en una serie de 14 residuos orgánicos, de distinto origen y tratamiento (compost, lodos, purines y digestato), comparando la información aportada por tres protocolos de fraccionamientos de P diferentes, seleccionados entre los principales métodos utilizados: protocolo de fraccionamiento de Ruttemberg (1992), protocolo de Normas, medidas y ensayos (Ruban et al., 2001a) y protocolo de Huang et al. (2008). Todos los métodos de fraccionamiento empleados aportaron información útil para conocer las formas de P de los residuos, a pesar de que alguno de ellos fue descrito para sedimentos o suelos. Sin embargo, resulta difícil comparar los resultados entre unos y otros, ya que cada uno emplea extractantes y tiempos de ensayos diferentes. Las cantidades de P total determinadas por cada método mantienen una relación lineal, aunque el método SMT, por ser más directo, obtiene las cantidades más elevadas para todos los residuos. Los métodos secuenciales (métodos de Huang y Ruttemberg), a pesar de ser más largos y tediosos, aportan información más detallada de la disponibilidad de las formas de P, y con ello, permiten obtener una mejor estimación de las pérdidas potenciales de este elemento tras su aplicación en suelo. Se han encontrado relaciones positivas entre las fracciones determinadas por estos dos métodos. Así mismo, se encuentra una correlación entre las formas solubles de P y la concentración de los iones [Ca + Fe + Al] de los residuos, útiles como indicadores de la disponibilidad de este elemento. Sin embargo, el protocolo SMT, no obtiene información de la solubilidad o disponibilidad de las formas de P contenidas, ni las formas determinadas mantienen relaciones directas con las de los otros métodos, con excepción del P total. Para el estudio del comportamiento de los residuos aplicados en suelos, se pusieron a punto sistemas de lluvia simulada, con el objetivo de caracterizar las pérdidas de P en la escorrentía superficial generada. Por otra parte, se emplearon columnas de suelos enmendados con residuos orgánicos, para el estudio de las pérdidas de P por lixiviación. Los ensayos de simulación de lluvia se llevaron a cabo de acuerdo al “National Phosphorus Research proyect“ (2001), que consigue simular eventos sucesivos de lluvia en unas condiciones semejantes a la realidad, empleando cajas llenas de suelo del horizonte superficial, con residuos aplicados tanto superficialmente como mediante mezcla con el propio suelo. Los ensayos se realizaron con seis residuos de diferente naturaleza y sometidos a distintos tratamientos. Se encontraron diferencias significativas en las pérdidas de las formas de P analizadas, tanto disueltas como particuladas, en las aguas de escorrentía generadas. En general, las pérdidas en el primer evento de lluvia tras la aplicación de los residuos fueron mayores a las generadas en el segundo evento, predominando las formas de P particuladas respecto a las disueltas en ambos. Se encontró una relación positiva entre las pérdidas de P en las aguas de escorrentía generadas en cada ensayo, con los contenidos de P soluble en agua y fácilmente disponible de los residuos empleados, determinados por los protocolos de fraccionamientos secuenciales. Además, se emplearon los modelos matemáticos desarrollados por Vadas et al. (2005, 2007), de evaluación de las pérdidas de P por escorrentía para fertilizantes y estiércoles. La predicción de estos modelos no se cumple en el caso de todos los residuos. Las distintas propiedades físicas de los residuos pueden afectar a las diferencias entre las pérdidas experimentales y las esperadas. Los ensayos de simulación del proceso de lixiviación se llevaron a cabo en columnas de percolación, con suelos enmendados con residuos orgánicos, de acuerdo a la norma “CEN/TS 14405–2004: Caracterización de los residuos – Test de comportamiento de lixiviación – Test de flujo ascendente”. Las pérdidas de P por procesos de lixiviación de agua, han sido despreciadas durante mucho tiempo respecto a las pérdidas por escorrentía. Sin embargo, se ha demostrado que deben tenerse en consideración, principalmente en algunos tipos de suelos o zonas cercanas a acuíferos. Se utilizaron tres suelos de distinta procedencia para los ensayos, de manera que se pudo estudiar la influencia del tipo de suelo en las pérdidas de P para cada tipo de residuo (purín, compost, digestato y lodo de EDAR). Los índices de adsorción de P determinados para cada suelo permiten evaluar aquellos que presentarán más riesgo de producir pérdidas de este elemento al aplicarse fuentes externas de P, encontrando una relación positiva entre ambos. Las pérdidas de P en los lixiviados varían en función tanto del residuo como del suelo empleado. Para el compost, el purín y el lodo, se encontró una relación entre las pérdidas generadas en el agua lixiviada de las columnas y las formas de P soluble contenidas en los residuos. Sin embargo, en el caso del digestato, no existía esta correlación. Las pérdidas para este residuo fueron en todos los casos menores a las estimadas, considerando las formas de P contenido. El estudio de la mojabilidad, propiedad física del residuo que evalúa la capacidad de interacción residuo-agua, permitió explicar el comportamiento anómalo de este residuo, con una mayor resistencia a que el agua entrara en su estructura y por tanto, una mayor dificultad de solubilizar el P contenido en el propio residuo, que en el caso de otros residuos. En general, podemos considerar que el estudio de las formas de P más disponibles o solubles en agua, aporta información útil de las pérdidas potenciales de P. Sin embargo, es necesario estudiar las propiedades físicas de los residuos orgánicos aplicados y la capacidad de adsorción de P de los suelos, para estimar las pérdidas de P y con ello, colaborar a controlar los procesos de eutrofización en aguas. ABSTRACT This dissertation explores the effect of organic wastes application as sources of P in losses of this element that occur by both surface runoff and leaching in soil. To do so, diverse laboratory experiments are conducted and presented here. Evaluating P losses is necessary to better understand the factors that influence the processes behind the loss of this element. Reducing P losses reduces eutrophication problems of both surface water and groundwater caused by an excess of this nutrient, along with other as nitrogen. Details of the experiments are presented below: The first experiment studies the forms of P contained in a series of 14 organic wastes of different origin and treatment (compost, sludge, slurry and digestate), comparing the information provided by three methods of P fractionation. The methods selected were: Ruttemberg protocol (1992); Standards, Measurements and Testing protocol (Ruban et al., 2001a); and Huang protocol (Huang et al., 2008). All fractionation methods employed successfully contribute to our knowledge of P forms in wastes, even though one of them was originally described for sediments or soils information. However, it is difficult to compare results among each other, as each protocol employs different extractants and time in the trials. Total amounts of P obtained by each method show a linear relationship, although the SMT method, which is more direct, obtains the highest amounts for all residues. Sequential methods (Huang and Ruttemberg’s protocols), despite being longer and more tedious, provide more detailed information on the availability of the forms of P. Therefore, allow the estimation of the potential losses of P after application in soil. Furthermore, positive relationships have been found among fractions obtained by these methods. Positive relationship has been found also among soluble forms of P and the concentration of ions Fe + Ca + Al, which is useful as an indicator of the availability of this element. However, the SMT protocol does not collect information about solubility or availability of forms of P contained; neither do certain forms maintain direct relations with the forms from other methods, with the exception of total P methods. To study the behavior of wastes applied to soils two experiments were conducted. Simulated rain systems were prepared to characterize P losses in the surface runoff generated. In addition, columns of soils amended with organic waste were developed for the study of P leaching losses. Simulated rain systems were carried out according to the ’National Phosphorus Research Project’ (2001), which manages to simulate successive rainfall events in conditions resembling reality. The experiment uses boxes filled with soil from the surface horizon amended with residues, both superficially and by mixing with the soil. Tests were conducted with six residues of different type and subjected to diverse treatments. Findings show significant differences in losses of the P forms analyzed in the generated runoff water, in both solution and particulate forms. In general, losses in the first rainfall event after application of waste were higher than the losses generated in the second event, predominating particulate forms of P over dissolved forms in both events. In all trials, a positive relationship was found between various P forms determined by sequential fractionation protocols (water soluble P and readily available P forms) and P losses in runoff. Furthermore, results from Vadas´s mathematical models (Vadas et al., 2005; 2007) to assess P losses by runoff fertilizers and manures indicate that the prediction of this model is not fulfilled in the case of all residues. The diverse physical properties of wastes may affect the differences between experimental and expected losses. Finally, leaching simulation processes were carried out in percolation columns, filled with soils amended with organic wastes, following the ‘CEN/TS 14405-2004 standard: Characterization of waste - Leaching behavior test - Test Flow ascending ’. P losses by leaching have been neglected for a long time with respect to runoff losses. However, findings corroborate previous studies showing that these P losses have to be taken into account, especially in certain types of soils and in zones near aquifers. To study the influence of soil type on P losses, experiments were carried out with three different soils and for each type of waste (manure, compost, digestate and sludge WWTP). Each soil’s P adsorption rates allow assessing which soils imply a higher risk of P losses when external sources of P are applied. P losses in leachate vary according to the type of soil employed and according to the specific residue. In the case of compost, manure and sludge, there is a relationship between leaching losses and residues’ soluble forms of P. The exception being the digestate, where there was no such correlation. Digestate P losses by leaching were lower than expected in all cases considering the forms of P contained. Moreover, examining digestate wettability -- that is, the physical property of the residue that assesses the capacity of waste-water interaction -- allowed explaining the anomalous behavior of this residue. Digestate has a high resistance to water entering its structure and thus higher difficulty to solubilize the P contained. Overall, studying the more available or soluble P forms provides useful information about the potential loss of P. However, this dissertation shows that it is necessary to examine the physical properties of organic residues applied as well as the P adsorption capacity of soils to estimate P losses, and thus to control eutrophication in water.
Resumo:
La presente investigación se presenta como una alternativa para la reducción de la contaminación por nutrientes que produce el vertido de aguas residuales provenientes de núcleos urbanos que acaban en lagos, lagunas o embalses acelerando los procesos de eutrofización de los mismos. El objetivo de esta tesis es analizar la reducción de nutrientes, fundamentalmente nitrógeno, fósforo y potasio, del agua residual doméstica sometida a tratamiento a través de cultivos hidropónicos en un determinado periodo de tiempo, observando a su vez la evolución del cultivo seleccionado. El sistema se diseñó para funcionar en circuito cerrado con el agua residual circulando por entre las raíces de los vegetales estudiados. El cultivo seleccionado fue el “kenaf”, aunque después de mucho tiempo dedicado a la obtención de semillas de “kenaf “por diferentes proveedores, se decidió comenzar un primer ensayo utilizando plantas de aloe vera durante un periodo de un mes de verano. Se procedió a la colocación de plantas en un tubo conteniendo agua residual de una fosa séptica domiciliaria. La reducción de la DBO5 y la DQO fue notable aunque los resultados de la variación de nitratos y fosfatos no fueron concluyentes. Las altas temperaturas alcanzada en esas fechas por el agua circulante, finalmente imposibilitó la continuación del ensayo. Si bien esta primera puesta en marcha no resultó como se esperaba, aportó numerosa información para modificar el planteo del estudio, la forma de llevarlo a cabo y la puesta a punto de la propia instalación. El segundo ensayo se llevó a cabo en otoño con plantas de kenaf obtenidas del ensayo previo en suelo en una parcela piloto en los llanos de Villamartín, en la provincia de Cádiz. Antes de incorporar el agua al sistema hidropónico se analizaron todos los parámetros requeridos por la normativa española del agua para determinar su clasificación como agua residual doméstica. Luego se le dio seguimiento a la variación de los nutrientes, nitrógeno, fósforo y potasio a lo largo de varias semanas para evaluar la efectividad del tratamiento. Las plantas de kenaf continuaron su desarrollo utilizando las sustancias disueltas en el agua residual como única fuente de nutrientes disponible. This research is presented as an alternative to reduce the pollution that wastewater discharges from towns generate when they end in lakes, ponds and reservoirs, by accelerating the eutrophication processes. The objective of this thesis is to analyze the reduction of nutrients, mainly nitrogen, phosphorus and potassium, of domestic wastewater treated through hydroponics crops in a given period of time, noting at the same time the evolution of the selected crop. The system was designed to operate in closed circuit with the wastewater circulating through the roots of the studied plants. The selected crop was "kenaf", although after much time spent in obtaining seeds of "kenaf"by different vendors and the impossibility of achieving its germination; it was decided to start a first test using Aloe Vera plants for a period of one month in the summer. The plants were introduced in the holes of a tube containing septic wastewater. The BOD5 and COD reduction was remarkable though the results of the variation in nitrates and phosphates were inconclusive. High temperatures achieved in those dates by circulating water, eventually precluded the continuation of the test. Although this first implementation was not running as expected, it provided information to modify the proposal of the study, the way to carry it out and the development of the installation itself. The second test was conducted in autumn with kenaf plants obtained from the previous test in a pilot plant in the flatness of Villamartín, province of Cádiz. Before adding the water to the hydroponic system all the parameters required by the Spanish water regulations were analyzed to determine their classification as domestic waste water. Then, the variation of nutrients, nitrogen, phosphorus and potassium was tracking over several weeks to evaluate the effectiveness of the treatment. Kenaf plants continued its development using the substances dissolved in wastewater as sole source of nutrients available.
Resumo:
En el estado de Veracruz, al sur de México, se ubican empresas dedicadas a la obtención de etanol a partir de melaza de azúcar de caña. Las más pequeñas, tienen una producción promedio de 20,000 L de alcohol/día. Los efluentes de la producción de etanol incluyen agua de enfriamiento de condensadores, agua del lavado de tanques de fermentación y vinazas, estas últimas son los efluentes más contaminantes en las destilerías, por su concentración de material orgánico biodegradable y no biodegradable. Las vinazas se generan en grandes volúmenes, produciéndose de 12 a 15 litros de vinazas por cada litro de alcohol destilado. Estos efluentes se caracterizan por tener altas temperaturas, pH ácido y una elevada concentración de DQO así como de sólidos totales. La determinación de la biodegradabilidad anaerobia de un agua residual, permite estimar la fracción de DQO que puede ser transformada potencialmente en metano y la DQO recalcitrante que queda en el efluente. Para el desarrollo de una prueba de biodegradabilidad, es importante considerar diversos factores relacionados con la composición del agua a tratar, composición de los lodos y las condiciones bajo las cuales se lleva a cabo la prueba. La digestión anaerobia de aguas residuales industriales es comúnmente usada en todo el mundo, ofrece significativas ventajas para el tratamiento de efluentes altamente cargados. Los sistemas anaerobios de tratamiento de aguas residuales industriales incluyen tecnologías con biopelículas, estos sistemas de tratamiento anaerobio con biopelícula son una tecnología bien establecida para el tratamiento de efluentes industriales. El Reactor de Lecho Fluidizado Inverso Anaerobio (LFI) ha sido diseñado para el tratamiento de aguas residuales de alta carga, teniendo como ventajas el empleo de un soporte que proporciona una gran superficie y un bajo requerimiento de energía para la fluidización del lecho. En el presente trabajo, se lleva a cabo el análisis de un proceso de producción de etanol, identificando a los efluentes que se generan en el mismo. Se encuentra que el efluente final está compuesto principalmente por las vinazas provenientes del proceso de destilación. En la caracterización de las vinazas provenientes del proceso de producción de etanol a partir de melaza de azúcar de caña, se encontraron valores promedio de DQO de 193.35 gDQO/L, para los sólidos totales 109.78 gST/L y pH de 4.64. Así mismo, en esta investigación se llevó a cabo una prueba de biodegradabilidad anaerobia, aplicada a la vinaza proveniente de la producción de etanol. En la caracterización de los lodos empleados en el ensayo se obtiene una Actividad Metanogénica Especifica de 0.14 g DQO/gSSV.d. El porcentaje de remoción de DQO de la vinaza fue de 62.7%, obteniéndose una k igual a 0.031 h-1 y una taza de consumo de sustrato de 1.26 gDQO/d. El rendimiento de metano fue de 0.19 LCH4/g DQOremovida y el porcentaje de biodegradabilidad de 54.1%. El presente trabajo también evalúa el desempeño de un LFI, empleando Extendospher® como soporte y tratando efluentes provenientes de la producción de etanol. El reactor se arrancó en batch y posteriormente se operó en continuo a diferentes Cargas Orgánicas Volumétricas de 0.5, 1.0, 3.3, 6.8 y 10.4 g DQO/L.d. Además, se evaluaron diferentes Tiempos de Residencia Hidráulica de 10, 5 y 1 días. El sistema alcanzó las siguientes eficiencias promedio de remoción de DQO: 81% para la operación en batch; 58, 67, 59 y 50 % para las cargas de 0.5, 1.0, 3.3, 6.8 g DQO/L.d respectivamente. Para la carga de 10.4 g DQO/L.d, la eficiencia promedio de remoción de DQO fue 38%, en esta condición el reactor presentó inestabilidad y disminución del rendimiento de metano. La generación de metano inició hasta los 110 días de operación del reactor a una carga de 1.0 g DQO/L.d. El sistema alcanzó un rendimiento de metano desde 0.15 hasta 0.34 LCH4/g DQO. Durante la operación del reactor a una carga constante de 6.4 g DQO/L.d, y un TRH de 1 día, se alcanzó una eficiencia promedio de remoción de DQO de 52%. In the state of Veracruz, to the south of Mexico, there are located companies dedicated to the production of ethanol from molasses of cane sugar. The smallest, have a average production of 20,000 L ethanol/day. The effluent of production of ethanol include water of condensers, water originated from the cleanliness of tanks of fermentation and vinasses, the above mentioned are more effluent pollutants in the distilleries, for the poor organic matter degradability. The vinasses are generated in high volumes, producing from 12 to 15 L of vinasses per every liter of distilled ethanol. These effluent are characterized by its high temperature, pH acid and a high concentration of DQO as well as high concentration of TS. The determination of the anaerobic degradability of a waste water, it allows to estimate the fraction of DQO that can be transformed potentially into methane and the recalcitrant DQO that stays in the effluent. For the development of degradability test, it is important to consider factors related to the composition of the water to be treated, composition of the sludge and the conditions under which the test is carried out. The anaerobic digestion of industrial wastes water is used commonly in the whole world, it offers significant advantages for the treatment of effluent highly loaded. The anaerobic treatment of industrial wastes water include technologies with biofilms, this anaerobic treatment whit biofilms systems, is a well-established technology for treatment of industrial effluents. The Anaerobic Inverse Fluidized Bed Reactor (IFBR) has been developed to provide biological treatment of high strength organic wastewater for their large specific surface and their low energy requirements for fluidization. In this work, there is carried out the analysis of a process of production of ethanol, identifying the effluent ones that are generated in the process. One determined that the effluent end is composed principally by the vinasses originated from the process of distillation. In the characterization of the vinasses originated from the process of production of ethanol from cane sugar molasses, there were average values of DQO of 193.35 gDQO/L, average values of solid of 109.78 gST/L and pH of 4.64. In this investigation there was carried out a anaerobic degradability test of the vinasses generated in the production of ethanol. In the characterization of the sludge used in the essay, the specific methanogenic activity (SMA) was 0.14 gDQO/gSSV.d. The average removal of DQO of the vinasses was 62.7 %, k equal to 0.031 h-1 was obtained one and a rate of removal substrate of 1.26 gDQO/d. The methane yield was 0.19 LCH4/gDQO removed and the anaerobic biodegradability was a 54.1 %. This study describes the performance of IFBR with Extendospher®, for the treatment of vinasses. The start-up was made in batch, increasing gradually the Organic Load Rate (OLR): 0.5, 1.0, 3.3, 6.8 and 10.4 g COD/L.d. Different Hydraulic Retention Times (HRT) were evaluated: 10, 5 and 1 days. During the operation in batch, the COD removal obtained was of 81 %, and for OLR of 0.5, 1.0, 3.3, 6.8 g COD/L.d the removal obtained was 58, 67, 59 and 50 % respectively. For a maximum OLR of 10.4 g COD/L.d, the COD removal was 38 %, and the system presented instability and decrease of the yield methane. The methane production initiated after 110 days of the start-up of the IFBR, to organic load rate of 1.0 g COD/L.d. The system reached values in the methane yield from 0.15 up to 0.34 LCH4/g CODremoved, for the different organic load rates. During the operation to a constant OLR of 6.4 g COD/L.d, and a HRT of 1 day, the Anaerobic Inverse Fluidized Bed Reactor reached a maximum efficiency of removal of 52 %.
Resumo:
Este trabalho teve como objetivo avaliar diversos métodos de detecção e recuperação de cistos de Giardia spp. e de oocistos de Cryptosporidium parvum em resíduos gerados no tratamento de águas de abastecimento com turbidez elevada tendo como padrão o Método 1623.1 da USEPA (2012 ). Para tanto, ensaios utilizando aparelho Jarteste (coagulação, floculação, decantação e filtração ) foram realizados utilizando o coagulante cloreto de polialumínio - PAC. Em todos os métodos avaliados foi utilizada a técnica de purificação por separação imunomagnética - IMS. A adaptação do método floculação em carbonato de cálcio FCCa elaborado por Vesey et al. (1993) e adaptado por Feng et al. (2011), repercutiu nos melhores resultados para a amostra de resíduo sedimentado, com recuperações de 68 ± 17 % para oocisto de C. parvum e de 42 ± 7 % para cisto de Giardia spp. Entretanto, as recuperações para a amostra de água de lavagem dos filtros - ALF foram inferiores à 1 %, não sendo possível determinar um método adequado. A presença dos patógenos indica que o reuso da ALF em ETA convencionais ou o descarte em mananciais sem um tratamento prévio, pode representar problemas de contaminação. A adaptação dos métodos de Boni de Oliveira (2012) e Keegan et al. (2008), também repercutiram em porcentagens de recuperação expressivas para a amostra de resíduo sedimentado, sendo de: 41 ± 35 % para oocisto de C. parvum e 11 ± 70 % para cisto de Giardia spp., e 38 ± 26 % para oocisto de C. parvum e 26 ± 13 % para cisto de Giardia spp., respectivamente. A análise estatística não resultou em diferença significativa entre estes dois métodos, entretanto, as elevadas recuperações indicam que estes métodos podem ser melhor avaliados em pesquisas futuras.
Disposição de resíduos gerados em estações de tratamento de água em estações de tratamento de esgoto
Resumo:
O presente trabalho foi realizado em duas fases. Na primeira, foram estimados os efeitos produzidos nos decantadores primários de uma ETE, após receber resíduo da ETA-SC, que utiliza sulfato de alumínio como coagulante. Foram realizados ensaios em colunas de sedimentação, onde os parâmetros SST, SSV, cor, turbidez, DQO, coliformes totais, Escherichia coli e parasitas, pesquisados no sobrenadante, diminuíram com o aumento da quantidade de resíduo adicionado. Com relação aos sedimentos obtidos nas colunas de sedimentação, foi encontrada maior quantidade de ST e menor resistência específica nos lodos provenientes das colunas que receberam os resíduos da ETA-SC. No teste de atividade metanogênica, a concentração molar de metano foi reduzida nos sistemas que receberam resíduo da ETA-SC, influenciando negativamente no desenvolvimento dos microrganismos metanogênicas. As espécies de microrganismos do gênero Methanothrix sp foram inibidas, sendo encontradas em maior número no frasco-reator controle e em menor quantidade a medida que se aumentou a quantidade do resíduo adicionado. Nesta etapa foi constatado que o resíduo da ETA-SC poderá apresentar interferências negativas sobre a digestão anaeróbia do lodo produzido em decantadores primários de uma ETE. Na segunda fase, na estação piloto, composta de lagoa de aeração seguida de lagoa de sedimentação, que recebeu resíduo da ETA-Fonte, que utiliza cloreto férrico como coagulante, foi verificado que tal resíduo melhorou a qualidade do efluente em termos de DQO, DBO, SST, turbidez, cor, amônio, nitrato, NTK e fosfato total. Os parâmetros ST, SDT, cloreto, nitrito, condutividade e pH não apresentaram diferenças significativas. Em relação ao exame microscópico não houve influências negativas no licor misto das lagoas de aeração. O lodo formado nas lagoas de sedimentação piloto apresentou-se em maior quantidade na lagoa que recebeu resíduo da ETA-Fonte. Neste lodo a resistência específica a filtração foi menor em comparação ao lodo da lagoa que não recebeu resíduo da ETA-Fonte. A desidratação deste lodo por centrifugação necessitou menor quantidade de polieletrólito. Baseado neste estudo não foi verificado interferências que possa impedir o lançamento do resíduo da ETA-Fonte na ETE-Araraquara.
Resumo:
The ubiquitous occurrence of pharmaceuticals and personal care products (PPCPs) in aquatic environments has raised concerns about potential adverse effects on aquatic ecology and human health. Certain pharmaceuticals have recently become a major focus of research to better understand the routes and persistence of these compounds once they enter into aquatic system. In this research, two model compounds were selected to represent pharmaceuticals that have been identified by recent research as being persistent; specifically, these compounds were trimethoprim (TMP, a basic antibiotic) and gemfibrozil (GEM, an acidic lipid regulator). Treatment of synthetic wastewater that contained these drugs was accomplished using wet-air oxidation (WAO). Pre- and post-treatment drug concentrations were determined by reversed-phase liquid chromatography. The influences of different operational conditions on removal efficiency of the drugs by WAO were evaluated, namely reaction time, initial drug concentration, oxygen concentration, and the amount and composition of additional organic matter used during WAO. The optimum removal efficiencies were found to be 91.9 % for TMP and 95.5 % for GEM.
Resumo:
Trihalomethanes are organic compounds formed in drinking water distribution systems as a result of disinfection. This capstone project researched and evaluated the statistical correlation of trihalomethanes in finished drinking water and total organic carbon in source water using data generated by Denver area utilities. Results of the study conclude that some drinking water supply systems show a slight correlation between source water total organic carbon levels and trihalomethane levels in finished water. Results of the study also verify the assertion that changes to treatment for the reduction of trihalomethanes, for the protection of human health under the Safe Drinking Water Act should be determined by each utility, using information from gathered data, seasonal trends, and small scale batch testing.
Resumo:
The adsorption and electroadsorption of arsenic from a natural water has been studied in a filter-press electrochemical cell using a commercial granular activated carbon as adsorbent and Pt/Ti and graphite as electrodes. A significant reduction of the arsenic concentration is achieved when current is imposed between the electrodes, especially when the activated carbon was located in the vicinity of the anode. This enhancement can be explained in terms of the presence of electrostatic interactions between the polarized carbon surface and the arsenic ions, and changes in the distribution of most stable species of arsenic in solution due to As(III) to As(V) oxidation. In summary, electrochemical adsorption on a filter-press cell can be used for enhancement the arsenic remediation with activated carbon in the treatment of a real groundwater.