951 resultados para Vessel loop


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: We assessed the impact of vessel size on angiographic and long-term clinical outcome after percutaneous coronary intervention (PCI) with sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES) within a randomized trial (SIRTAX [Sirolimus-Eluting Stent Compared With Paclitaxel-Eluting Stent for Coronary Revascularization]). BACKGROUND: Percutaneous coronary intervention in small-vessel disease is associated with an increased risk of major adverse cardiac events (MACE). METHODS: A total of 1,012 patients were randomly assigned to treatment with SES (n = 503) or PES (n = 509). A stratified analysis of angiographic and clinical outcome was performed up to 2 years after PCI according to size of the treated vessel (reference vessel diameter < or =2.75 vs. >2.75 mm). RESULTS: Of 1,012 patients, 370 patients (37%) with 495 lesions underwent stent implantation in small vessels only, 504 patients (50%) with 613 lesions in large vessels only, and 138 patients (14%) with 301 lesions in both small and large vessels (mixed). In patients with small-vessel stents, SES reduced MACE by 55% (10.4% vs. 21.4%; p = 0.004), mainly driven by a 69% reduction of target lesion revascularization (TLR) (6.0% vs. 17.7%; p = 0.001) compared with PES at 2 years. In patients with large- and mixed-vessel stents, rates of MACE (large: 10.4% vs. 13.1%; p = 0.33; mixed: 16.7% vs. 18.0%; p = 0.83) and TLR (large: 6.9% vs. 8.6%; p = 0.47; mixed: 16.7% vs. 15.4%; p = 0.86) were similar for SES and PES. There were no significant differences with respect to death and myocardial infarction between the 3 groups. CONCLUSIONS: Compared with PES, SES more effectively reduced MACE and TLR in small-vessel disease. Differences between SES and PES appear less pronounced in patients with large- and mixed-vessel disease. (The SIRTAX trial; http://clinicaltrials.gov/ct/show/NCT00297661?order=1; NCT00297661).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Benzodiazepines are widely used drugs exerting sedative, anxiolytic, muscle relaxant, and anticonvulsant effects by acting through specific high affinity binding sites on some GABA(A) receptors. It is important to understand how these ligands are positioned in this binding site. We are especially interested here in the conformation of loop A of the alpha(1)beta(2)gamma(2) GABA(A) receptor containing a key residue for the interaction of benzodiazepines: alpha(1)H101. We describe a direct interaction of alpha(1)N102 with a diazepam- and an imidazobenzodiazepine-derivative. Our observations help to better understand the conformation of this region of the benzodiazepine pocket in GABA(A) receptor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To determine the accuracy of automated vessel-segmentation software for vessel-diameter measurements based on three-dimensional contrast-enhanced magnetic resonance angiography (3D-MRA). METHOD: In 10 patients with high-grade carotid stenosis, automated measurements of both carotid arteries were obtained with 3D-MRA by two independent investigators and compared with manual measurements obtained by digital subtraction angiography (DSA) and 2D maximum-intensity projection (2D-MIP) based on MRA and duplex ultrasonography (US). In 42 patients undergoing carotid endarterectomy (CEA), intraoperative measurements (IOP) were compared with postoperative 3D-MRA and US. RESULTS: Mean interoperator variability was 8% for measurements by DSA and 11% by 2D-MIP, but there was no interoperator variability with the automated 3D-MRA analysis. Good correlations were found between DSA (standard of reference), manual 2D-MIP (rP=0.6) and automated 3D-MRA (rP=0.8). Excellent correlations were found between IOP, 3D-MRA (rP=0.93) and US (rP=0.83). CONCLUSION: Automated 3D-MRA-based vessel segmentation and quantification result in accurate measurements of extracerebral-vessel dimensions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Based on a subgroup analysis of 18-month BAsel Stent Kosten Effektivitäts Trial (BASKET) outcome data, we hypothesized that very late (> 12 months) stent thrombosis occurs predominantly after drug-eluting stent implantation in large native coronary vessel stenting. METHODS: To prove or refute this hypothesis, we set up an 11-center 4-country prospective trial of 2260 consecutive patients treated with > or = 3.0-mm stents only, randomized to receive Cypher (Johnson ; Johnson, Miami Lakes, FL), Vision (Abbott Vascular, Abbott Laboratories, IL), or Xience stents (Abbott Vascular). Only patients with left main or bypass graft disease, in-stent restenosis or stent thrombosis, in need of nonheart surgery, at increased bleeding risk, without compliance/consent are excluded. All patients are treated with dual antiplatelet therapy for 12 months. The primary end point will be cardiac death/nonfatal myocardial infarction after 24 months with further follow-up up to 5 years. RESULTS: By June 12, 229 patients (10% of the planned total) were included with a baseline risk similar to that of the same subgroup of BASKET (n = 588). CONCLUSIONS: This study will answer several important questions of contemporary stent use in patients with large native vessel stenting. The 2-year death/myocardial infarction-as well as target vessel revascularization-and bleeding rates in these patients with a first- versus second-generation drug-eluting stent should demonstrate the benefit or harm of these stents compared to cobalt-chromium bare-metal stents in this relevant, low-risk group of everyday patients. In addition, a comparison with similar BASKET patients will allow to estimate the impact of 12- versus 6-month dual antiplatelet therapy on these outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Recanalization of the culprit lesion is the main goal of primary angioplasty for acute ST-segment elevation myocardial infarction (STEMI). Patients presenting with acute myocardial infarction and multivessel disease are, therefore, usually subjected to staged procedures, with the primary percutaneous coronary intervention (PCI) confined to recanalization of the infarct-related artery (IRA). Theoretically at least, early relief of stenoses of non-infarct-related arteries could promote collateral circulation, which could help to limit the infarct size. However, the safety and feasibility of such an approach has not been adequately established. METHODS: In this single-center prospective study we examined 73 consecutive patients who had an acute STEMI and at least one or more lesions > or = 70% in a major epicardial vessel other than the infarct-related artery. In the first 28 patients, forming the multi-vessel (MV) PCI group, all lesions were treated during the primary procedure. In the following 45 patients, forming the culprit-only (CO) PCI group, only the culprit lesion was treated during the initial procedure, followed by either planned-staged or ischemia-driven revascularization of the non-culprit lesions. Fluoroscopy time and contrast dye amount were compared between both groups, and patients were followed up for one year for major adverse cardiac events (MACE) and other significant clinical events. RESULTS: The two groups were well balanced in terms of clinical characteristics, number of diseased vessels and angiographic characteristics of the culprit lesion. In the MV-PCI group, 2.51 lesions per patient were treated using 2.96 +/- 1.34 stents (1.00 lesions and 1.76 +/- 1.17 stents in the CO-PCI group, both p < 0.001). The fluoroscopy time increased from 10.3 (7.2-16.9) min in the CO-PCI group to 12.5 (8.5-19.3) min in the MV-PCI group (p = 0.22), and the amount of contrast used from 200 (180-250) ml to 250 (200-300) ml, respectively (p = 0.16). Peak CK and CK-MB were significantly lower in patients of the MV-PCI group (843 +/- 845 and 135 +/- 125 vs 1652 +/- 1550 and 207 +/- 155 U/l, p < 0.001 and 0.01, respectively). Similar rates of major adverse cardiac events at one year were observed in the two groups (24% and 28% in multi-vessel and culprit treatment groups, p = 0.73). The incidence of new revascularization in both infarct- and non-infarct-related arteries was also similar (24% and 28%, respectively, p = 0.73). CONCLUSION: We may state from this limited experience that a multi-vessel stenting approach for patients with acute STEMI and multi-vessel disease is feasible and probably safe during routine clinical practice. Our data suggest that this approach may help to limit the infarct size. However, larger studies, perhaps using drug-eluting stents, are still needed to further evaluate the safety and efficiency of this procedure, and whether it is associated with a lower need of subsequent revascularization and lower costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spray characterization under flash boiling conditions was investigated utilizing a symmetric multi-hole injector applicable to the gasoline direct injection (GDI) engine. Tests were performed in a constant volume combustion vessel using a high-speed schlieren and Mie scattering imaging systems. Four fuels including n-heptane, 100% ethanol, pure ethanol blended with 15% iso-octane by volume, and test grade E85 were considered in the study. Experimental conditions included various ambient pressure, fuel temperature, and fuel injection pressure. Visualization of the vaporizing spray development was acquired by utilizing schlieren and laser-based Mie scattering techniques. Time evolved spray tip penetration, spray angle, and the ratio of the vapor to liquid region were analyzed by utilizing digital image processing techniques in MATLAB. This research outlines spray characteristics at flash boiling and non-flash boiling conditions. At flash boiling conditions it was observed that individual plumes merge together, leading to significant contraction in spray angle as compared to non-flash boiling conditions. The results indicate that at flash boiling conditions, spray formation and expansion of vapor region is dependent on momentum exchange offered by the ambient gas. A relation between momentum exchange and liquid spray angle formed was also observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of embedded control systems for a Hybrid Electric Vehicle (HEV) is a challenging task due to the multidisciplinary nature of HEV powertrain and its complex structures. Hardware-In-the-Loop (HIL) simulation provides an open and convenient environment for the modeling, prototyping, testing and analyzing HEV control systems. This thesis focuses on the development of such a HIL system for the hybrid electric vehicle study. The hardware architecture of the HIL system, including dSPACE eDrive HIL simulator, MicroAutoBox II and MotoTron Engine Control Module (ECM), is introduced. Software used in the system includes dSPACE Real-Time Interface (RTI) blockset, Automotive Simulation Models (ASM), Matlab/Simulink/Stateflow, Real-time Workshop, ControlDesk Next Generation, ModelDesk and MotoHawk/MotoTune. A case study of the development of control systems for a single shaft parallel hybrid electric vehicle is presented to summarize the functionality of this HIL system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Whether or not a protective stoma reduces the rate of anastomotic leakage after distal colorectal anastomosis is still discussed controversially. It does however facilitate clinical management once leakage has occurred. Loop ileostomies seem to be associated with a lower morbidity and a better quality of life compared to loop colostomies. Generally, diverting loop ileostomies are secured at skin level by means of a supporting device in order to prevent retraction of the ileostomy into the abdomen. However, due to the supporting rod, difficulties may occur in applying a stoma bag correctly and leakage of faeces onto the skin may occur even with correct eversion of the afferent limb. Our aim was to compare morbidity and time to self-sufficient stoma-care in patients having a loop ileostomy with rod to those without rod. Methods: A total of 60 patients necessitating loop ileostomy were analyzed. Patients received surgery in of the two involved institutions according to inhouse standard procedures. 30 patients had an ileostomy with rod (VCHK Inselspital) and a further 30 without rod (KSW Winterthur). Morbidity and time to self-sufficiency regarding stoma care was analyzed during the first 90 postoperative days. Morbidity was determined according to a scoring system ranging from 0 to 4 points for any given set of possible complications (bleeding, necrosis, skin irritation, abscess, stenosis, retraction, fistula, prolapse, parastomal hernia, incomplete diversion), where 0 = no complication and 4 = severe complication. Continuous variables were expressed as median (95% Confidence Interval). For comparisons between the groups the Mann-Whitney U test was used, between categorical variables the X2 test was applied. Results: There were no significant differences in length of hospital stay or time to self-sufficient stoma-care between the groups. Although not significant, patients with a rod ileostomy had a tendency towards more stoma-related complications as well as stoma-related reoperations. The number of patients reaching total self-sufficiency regarding stoma care was higher after rodless ileostomy. Conclusion: According to our data, rodless ileostomies seemto fare just as well as those with a supporting rod, with equal morbidity rates and more patients reaching self-sufficient stoma care. Therefore routine application of a rod for diverting loop ileostomy seems unnecessary

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Transient elevation of arterial blood pressure (BP) is frequent in acute ischemic stroke and may help to increase perfusion of tissue jeopardized by ischemia. If this is true, recanalization may eliminate the need for this BP elevation. METHODS: We analyzed BP in 149 patients with acute ischemic stroke on admission to the hospital and 1 and 12 hours after intraarterial thrombolysis. BP values of patients with adequate recanalization were compared with BP values of patients with inadequate recanalization. Recanalization was determined on cerebral arteriography after thrombolysis using thrombolysis in myocardial infarction grades. RESULTS: Systolic, mean, and diastolic arterial BP decreased significantly from admission to 12 hours after thrombolysis in all patients (P<0.001). Before thrombolysis, patients with adequate and inadequate recanalization showed equal systolic (147.4 and 148.0 mm Hg), mean (102.1 and 104.1 mm Hg), and diastolic (79.5 and 82.1 mm Hg) BP values. Twelve hours after thrombolysis, patients with adequate recanalization had lower values than those with inadequate recanalization (systolic BP, 130 versus 139.9 mm Hg; mean BP, 86.8 versus 92.2 mm Hg; and diastolic, BP 65.2 versus 68.3 mm Hg). Two-way repeated ANOVA analysis showed a significant group x time interaction for systolic BP, indicating a larger systolic BP decrease when recanalization succeeded (P=0.019). CONCLUSIONS: The course of elevated systolic but not diastolic BP after acute ischemic stroke was found to be inversely associated with the degree of vessel recanalization. When recanalization failed, systolic BP remained elevated longer than when it succeeded.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: The major goal of acute ischemic stroke treatment is fast and sufficient recanalization. Percutaneous transluminal balloon angioplasty (PTA) and/or placement of a stent might achieve both by compressing the thrombus at the occlusion site. This study assesses the feasibility, recanalization rate, and complications of the 2 techniques in an animal model. MATERIALS AND METHODS: Thirty cranial vessels of 7 swine were occluded by injection of radiopaque thrombi. Fifteen vessel occlusions were treated by PTA alone and 15, by placement of a stent and postdilation. Recanalization was documented immediately after treatment and after 1, 2, and 3 hours. Thromboembolic events and dissections were documented. RESULTS: PTA was significantly faster to perform (mean, 16.6 minutes versus 33.0 minutes for stent placement; P < .001), but the mean recanalization rate after 1 hour was significantly better after stent placement compared with PTA alone (67.5% versus 14.6%, P < .001). Due to the self-expanding force of the stent, vessel diameter further increased with time, whereas the recanalization result after PTA was prone to reocclusion. Besides thromboembolic events related to the passing maneuvers at the occlusion site, no thrombus fragmentation and embolization occurred during balloon inflation or stent deployment. Flow to side branches could also be restored at the occlusion site because it was possible to direct thrombus compression. CONCLUSIONS: Stent placement and postdilation proved to be much more efficient in terms of acute and short-term vessel recanalization compared with PTA alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

More than eighteen percent of the world’s population lives without reliable access to clean water, forced to walk long distances to get small amounts of contaminated surface water. Carrying heavy loads of water long distances and ingesting contaminated water can lead to long-term health problems and even death. These problems affect the most vulnerable populations, women, children, and the elderly, more than anyone else. Water access is one of the most pressing issues in development today. Boajibu, a small village in Sierra Leone, where the author served in Peace Corps for two years, lacks access to clean water. Construction of a water distribution system was halted when a civil war broke out in 1992 and has not been continued since. The community currently relies on hand-dug and borehole wells that can become dirty during the dry season, which forces people to drink contaminated water or to travel a far distance to collect clean water. This report is intended to provide a design the system as it was meant to be built. The water system design was completed based on the taps present, interviews with local community leaders, local surveying, and points taken with a GPS. The design is a gravity-fed branched water system, supplied by a natural spring on a hill adjacent to Boajibu. The system’s source is a natural spring on a hill above Boajibu, but the flow rate of the spring is unknown. There has to be enough flow from the spring over a 24-hour period to meet the demands of the users on a daily basis, or what is called providing continuous flow. If the spring has less than this amount of flow, the system must provide intermittent flow, flow that is restricted to a few hours a day. A minimum flow rate of 2.1 liters per second was found to be necessary to provide continuous flow to the users of Boajibu. If this flow is not met, intermittent flow can be provided to the users. In order to aid the construction of a distribution system in the absence of someone with formal engineering training, a table was created detailing water storage tank sizing based on possible source flow rates. A builder can interpolate using the source flow rate found to get the tank size from the table. However, any flow rate below 2.1 liters per second cannot be used in the table. In this case, the builder should size the tank such that it can take in the water that will be supplied overnight, as all the water will be drained during the day because the users will demand more than the spring can supply through the night. In the developing world, there is often a problem collecting enough money to fund large infrastructure projects, such as a water distribution system. Often there is only enough money to add only one or two loops to a water distribution system. It is helpful to know where these one or two loops can be most effectively placed in the system. Various possible loops were designated for the Boajibu water distribution system and the Adaptive Greedy Heuristic Loop Addition Selection Algorithm (AGHLASA) was used to rank the effectiveness of the possible loops to construct. Loop 1 which was furthest upstream was selected because it benefitted the most people for the least cost. While loops which were further downstream were found to be less effective because they would benefit fewer people. Further studies should be conducted on the water use habits of the people of Boajibu to more accurately predict the demands that will be placed on the system. Further population surveying should also be conducted to predict population change over time so that the appropriate capacity can be built into the system to accommodate future growth. The flow at the spring should be measured using a V-notch weir and the system adjusted accordingly. Future studies can be completed adjusting the loop ranking method so that two users who may be using the water system for different lengths of time are not counted the same and vulnerable users are weighted more heavily than more robust users.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluates the clinical applicability of administering sodium nitroprusside by a closed-loop titration system compared with a manually adjusted system. The mean arterial pressure (MAP) was registered every 10 and 30 sec during the first 150 min after open heart surgery in 20 patients (group 1: computer regulation) and in ten patients (group 2: manual regulation). The results (16,343 and 2,912 data points in groups 1 and 2, respectively), were then analyzed in four time frames and five pressure ranges to indicate clinical efficacy. Sixty percent of the measured MAP in both groups was within the desired +/- 10% during the first 10 min. Thereafter until the end of observation, the MAP was maintained within +/- 10% of the desired set-point 90% of the time in group 1 vs. 60% of the time in group 2. One percent and 11% of data points were +/- 20% from the set-point in groups 1 and 2, respectively (p less than .05, chi-square test). The computer-assisted therapy provided better control of MAP, was safe to use, and helped to reduce nursing demands.