994 resultados para Ultrasonic measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interfacial area measurement has been carried out experimentally by measuring the bubble size and holdup for air-sodium chloride solution system. The size of the bubble is predominantly established by the air hold up. High speed photography technique for bubble size measurement and gamma ray attenuation method for holdup measurements are followed. The measured values are compared with the theoretically predicted values. Interracial area as a function of the liquid flow rate and also its distance from the nozzle of the ejector has been reported in this paper. The results obtained for this non-reactive system are also compared with those of air-water system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whilst the topic of soil salinity has received a substantive research effort over the years, the accurate measurement and interpretation of salinity tolerance data remain problematic. The tolerance of four perennial grass species (non-halophytes) to sodium chloride (NaCl) dominated salinity was determined in a free-flowing sand culture system. Although the salinity tolerance of non-halophytes is often represented by the threshold salinity model (bent-stick model), none of the species in the current study displayed any observable salinity threshold. Further, the observed yield decrease was not linear as suggested by the model. On re-examination of earlier datasets, we conclude that the threshold salinity model does not adequately describe the physiological processes limiting growth of non-halophytes in saline soils. Therefore, the use of the threshold salinity model is not recommended for non-halophytes, but rather, a model which more accurately reflects the physiological response observed in these saline soils, such as an exponential regression curve.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The short duration of the Doppler signal and noise content in it necessitate a validation scheme to be incorporated in the electronic processor used for frequency measurement, There are several different validation schemes that can be employed in period timing devices. A detailed study of the influence of these validation schemes on the measured frequency has been reported here. These studies were carried out by using a combination of a fast A/D converter and computer. Doppler bursts obtained from an air flow were digitised and stored on magnetic discs. Suitable computer programs were then used to simulate the performance of period timing devices with different validation schemes and the frequency of the stored bursts were evaluated. It is found that best results are obtained when the validation scheme enables frequency measurement to be made over a large number of cycles within the burst.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective This study explored the dimensionality and measurement invariance of the 25-item Connor-Davidson Resilience Scale (CD-RISC; Connor & Davidson, 2003) across samples of adult (n = 321; aged 20–36) and adolescent (n = 199; aged 12–18) Australian cricketers. Design Cross-sectional, self-report survey Methods An online, multi-section questionnaire. Results Confirmatory factor and item level analyses supported the psychometric superiority of a revised 10-item, unidimensional model of resilience over the original 25-item, five-factor measurement model. Positive and moderate correlations with hardiness as well as negative and moderate correlations with burnout components were evidenced thereby providing support for the convergent validity of the unidimensional model. Measurement invariance analyses of the unidimensional model across the two age-group samples supported configural (i.e., same factor structure across groups), metric (i.e., same pattern of factor loadings across the groups), and partial scalar invariance (i.e., mostly the same intercepts across the groups). Conclusion Evidence for a psychometrically sound measure of resilient qualities of the individual provides an important foundation upon which researchers can identify the antecedents to and outcomes of resilience in sport contexts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We discuss the inverse problem associated with the propagation of the field autocorrelation of light through a highly scattering object like tissue. In the first part of the work, we reconstructed the optical absorption coefficient mu(u) and particle diffusion coefficient D-B from simulated measurements which are integrals of a quantity computed from the measured intensity and intensity autocorrelation g(2)(tau) at the boundary. In the second part we recover the mean square displacement (MSD) distribution of particles in an inhomogeneous object from the sampled g(2)(tau) measure on the boundary. From the MSD, we compute the storage and loss moduli distributions in the object. We have devised computationally easy methods to construct the sensitivity matrices which are used in the iterative reconstruction algorithms for recovering these parameters from the measurements. The results of the reconstruction of mu(a), D-B, MSD and the viscoelastic parameters, which are presented, show reasonable good position and quantitative accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To strive to improve the rehabilitation program of individuals with transfemoral amputation fitted with bone-anchored prosthesis based on data from direct measurements of the load applied on the residuum we first of all need to understand the load applied on the fixation. Therefore the load applied on the residuum was first directly measured during standardized activities of daily living such as straight line level walking, ascending and descending stairs and a ramp and walking around a circle. From measuring the load in standardized activities of daily living the load was also measured during different phases of the rehabilitation program such as during walking with walking aids and during load bearing exercises.[1-15] The rehabilitation program for individuals with a transfemoral amputation fitted with an OPRA implant relies on a combination of dynamic and static load bearing exercises.[16-20] This presentation will focus on the study of a set of experimental static load bearing exercises. [1] A group of eleven individuals with unilateral transfemoral amputation fitted with an OPRA implant participated in this study. The load on the implant during the static load bearing exercises was measured using a portable system including a commercial transducer embedded in a short pylon, a laptop and a customized software package. This apparatus was previously shown effective in a proof-of-concept study published by Prof. Frossard. [1-9] The analysis of the static load bearing exercises included an analysis of the reliability as well as the loading compliance. The analysis of the loading reliability showed a high reliability between the loading sessions indicating a correct repetition of the LBE by the participants. [1, 5] The analysis of the loading compliance showed a significant lack of axial compliance leading to a systematic underloading of the long axis of the implant during the proposed experimental static LBE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The purpose of this presentation is to outline the relevance of the categorization of the load regime data to assess the functional output and usage of the prosthesis of lower limb amputees. The objectives are • To highlight the need for categorisation of activities of daily living • To present a categorization of load regime applied on residuum, • To present some descriptors of the four types of activity that could be detected, • To provide an example the results for a case. Methods The load applied on the osseointegrated fixation of one transfemoral amputee was recorded using a portable kinetic system for 5 hours. The load applied on the residuum was divided in four types of activities corresponding to inactivity, stationary loading, localized locomotion and directional locomotion as detailed in previously publications. Results The periods of directional locomotion, localized locomotion, and stationary loading occurred 44%, 34%, and 22% of recording time and each accounted for 51%, 38%, and 12% of the duration of the periods of activity, respectively. The absolute maximum force during directional locomotion, localized locomotion, and stationary loading was 19%, 15%, and 8% of the body weight on the anteroposterior axis, 20%, 19%, and 12% on the mediolateral axis, and 121%, 106%, and 99% on the long axis. A total of 2,783 gait cycles were recorded. Discussion Approximately 10% more gait cycles and 50% more of the total impulse than conventional analyses were identified. The proposed categorization and apparatus have the potential to complement conventional instruments, particularly for difficult cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Online dynamic load modeling has become possible with the availability of Static Voltage Compensator (SVC) and Phasor Measurement Unit (PMU) devices. The power of the load response to the small random bounded voltage fluctuations caused from SVC can be measured by PMU for modelling purposes. The aim of this paper is to illustrate the capability of identifying an aggregated load model from high voltage substation level in the online environment. The induction motor is used as the main test subject since it contributes the majority of the dynamic loads. A test system representing simple electromechanical generator model serving dynamic loads through the transmission network is used to verify the proposed method. Also, dynamic load with multiple induction motors are modeled to achieve a better realistic load representation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electron-electron scattering contribution to the ultrasonic attenuation in potassium at low temperatures is evaluated using the Landau Fermi liquid theory. The scattering function is evaluated using the approximation suggested by MacDonald and Geldart. The results are compared with theoretically evaluated electron-phonon scattering contributions. The results show that the electron-electron scattering contribution is of the same order as the electron-phonon scattering contribution in the 2–5 K range. Below 2 K the electron-electron scattering predominates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: The aims of this study were 1) to identify and describe health economic studies that have used quality-adjusted life years (QALYs) based on actual measurements of patients' health-related quality of life (HRQoL); 2) to test the feasibility of routine collection of health-related quality of life (HRQoL) data as an indicator of effectiveness of secondary health care; and 3) to establish and compare the cost-utility of three large-volume surgical procedures in a real-world setting in the Helsinki University Central Hospital, a large referral hospital providing secondary and tertiary health-care services for a population of approximately 1.4 million. Patients and methods: So as to identify studies that have used QALYs as an outcome measure, a systematic search of the literature was performed using the Medline, Embase, CINAHL, SCI and Cochrane Library electronic databases. Initial screening of the identified articles involved two reviewers independently reading the abstracts; the full-text articles were also evaluated independently by two reviewers, with a third reviewer used in cases where the two reviewers could not agree a consensus on which articles should be included. The feasibility of routinely evaluating the cost-effectiveness of secondary health care was tested by setting up a system for collecting HRQoL data on approximately 4 900 patients' HRQoL before and after operative treatments performed in the hospital. The HRQoL data used as an indicator of treatment effectiveness was combined with diagnostic and financial indicators routinely collected in the hospital. To compare the cost-effectiveness of three surgical interventions, 712 patients admitted for routine operative treatment completed the 15D HRQoL questionnaire before and also 3-12 months after the operation. QALYs were calculated using the obtained utility data and expected remaining life years of the patients. Direct hospital costs were obtained from the clinical patient administration database of the hospital and a cost-utility analysis was performed from the perspective of the provider of secondary health care services. Main results: The systematic review (Study I) showed that although QALYs gained are considered an important measure of the effectiveness of health care, the number of studies in which QALYs are based on actual measurements of patients' HRQoL is still fairly limited. Of the reviewed full-text articles, only 70 reported QALYs based on actual before after measurements using a valid HRQoL instrument. Collection of simple cost-effectiveness data in secondary health care is feasible and could easily be expanded and performed on a routine basis (Study II). It allows meaningful comparisons between various treatments and provides a means for allocating limited health care resources. The cost per QALY gained was 2 770 for cervical operations and 1 740 for lumbar operations. In cases where surgery was delayed the cost per QALY was doubled (Study III). The cost per QALY ranges between subgroups in cataract surgery (Study IV). The cost per QALY gained was 5 130 for patients having both eyes operated on and 8 210 for patients with only one eye operated on during the 6-month follow-up. In patients whose first eye had been operated on previous to the study period, the mean HRQoL deteriorated after surgery, thus precluding the establishment of the cost per QALY. In arthroplasty patients (Study V) the mean cost per QALY gained in a one-year period was 6 710 for primary hip replacement, 52 270 for revision hip replacement, and 14 000 for primary knee replacement. Conclusions: Although the importance of cost-utility analyses has during recent years been stressed, there are only a limited number of studies in which the evaluation is based on patients own assessment of the treatment effectiveness. Most of the cost-effectiveness and cost-utility analyses are based on modeling that employs expert opinion regarding the outcome of treatment, not on patient-derived assessments. Routine collection of effectiveness information from patients entering treatment in secondary health care turned out to be easy enough and did not, for instance, require additional personnel on the wards in which the study was executed. The mean patient response rate was more than 70 %, suggesting that patients were happy to participate and appreciated the fact that the hospital showed an interest in their well-being even after the actual treatment episode had ended. Spinal surgery leads to a statistically significant and clinically important improvement in HRQoL. The cost per QALY gained was reasonable, at less than half of that observed for instance for hip replacement surgery. However, prolonged waiting for an operation approximately doubled the cost per QALY gained from the surgical intervention. The mean utility gain following routine cataract surgery in a real world setting was relatively small and confined mostly to patients who had had both eyes operated on. The cost of cataract surgery per QALY gained was higher than previously reported and was associated with considerable degree of uncertainty. Hip and knee replacement both improve HRQoL. The cost per QALY gained from knee replacement is two-fold compared to hip replacement. Cost-utility results from the three studied specialties showed that there is great variation in the cost-utility of surgical interventions performed in a real-world setting even when only common, widely accepted interventions are considered. However, the cost per QALY of all the studied interventions, except for revision hip arthroplasty, was well below 50 000, this figure being sometimes cited in the literature as a threshold level for the cost-effectiveness of an intervention. Based on the present study it may be concluded that routine evaluation of the cost-utility of secondary health care is feasible and produces information essential for a rational and balanced allocation of scarce health care resources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a molecular mechanism for the intra-cellular measurement of the ratio of the number of X chromosomes to the number of sets of autosomes, a process central to both sex determination and dosage compensation in Drosophila melanogaster. In addition to the two loci, da and Sxl, which have been shown by Cline (Genetics, 90, 683, 1978)and others to be involved in these processes, we postulate two other loci, one autosomal (ω) and the other, X-linked (π). The product of the autosomal locus da stimulates ω and initiates synthesis of a limited quantity of repressor. Sxl and π ,both of which are X-linked, compete for this repressor as well as for RNA polymerase. It is assumed that Sxl has lower affinity than π for repressor as well as polymerase and that the binding of polymerase to one of these sites modulates the binding affinity of the other site for the enzyme. It can be shown that as a result of these postulated interactions transcription from the Sxl site is proportional to the X/A ratio such that the levels of Sxl+ product are low in males, high in females and intermediate in the intersexes. If, as proposed by Cline, the Sxl- product is an inhibitor of X chromosome activity, this would result in dosage compensation. The model leads to the conclusion that high levels of Sxl+ product promote a female phenotype and low levels, a male phenotype. One interesting consequence of the assumptions on which the model is based is that the level of Sxl+ product in the cell, when examined as a function of increasing repressor concentration, first goes up and then decreases, yielding a bell-shaped curve. This feature of the model provides an explanation for some of the remarkable interactions among mutants at the Sxl, da and mle loci and leads to several predictions. The proposed mechanism may also have relevance to certain other problems, such as size regulation during development, which seem to involve measurement of ratios at the cellular level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By using electric-field-induced optical second-harmonic generation (EFISHG) measurement, we analyzed hysteresis behavior of capacitance-voltage (C-V) characteristics of IZO/polyterpenol (PT)/C₆₀/pentacene/Au diodes, where PT layer is actively working as a hole-transport electron-blocking layer. The EFISHG measurement verified the presence of interface accumulated charges in the diodes, and showed that a space charge electric field from accumulated excess electrons (holes) that remain at the PT/C₆₀ (C₆₀/pentacene) interface is responsible for the hysteresis loop observed in the C-V characteristics.