829 resultados para Thermal stimulus


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to determine the penetration of the thermal wave in the papaya fruit pulp (Carica papaya L.), cv. Golden, thermal diffusivity of the pulp was obtained measuring temperature at four different depths. Measurements were carried out initially with the fruit on the first stage of maturity. The changes of the thermal diffusivity were expressed as a function of ripening. A temporal decrease of the thermal diffusivity was observed. Chemical (pH, soluble solids and total titratable acidity) and physical (pulp firmness) properties were measured as well and the results were compared to the thermal diffusivity change.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monte Carlo (MC) simulations have been used to study the structure of an intermediate thermal phase of poly(R-octadecyl ç,D-glutamate). This is a comblike poly(ç-peptide) able to adopt a biphasic structure that has been described as a layered arrangement of backbone helical rods immersed in a paraffinic pool of polymethylene side chains. Simulations were performed at two different temperatures (348 and 363 K), both of them above the melting point of the paraffinic phase, using the configurational bias MC algorithm. Results indicate that layers are constituted by a side-by-side packing of 17/5 helices. The organization of the interlayer paraffinic region is described in atomistic terms by examining the torsional angles and the end-to-end distances for the octadecyl side chains. Comparison with previously reported comblike poly(â-peptide)s revealed significant differences in the organization of the alkyl side chains.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The structural relaxation of pure amorphous silicon a-Si and hydrogenated amorphous silicon a-Si:H materials, that occurs during thermal annealing experiments, has been analyzed by Raman spectroscopy and differential scanning calorimetry. Unlike a-Si, the heat evolved from a-Si:H cannot be explained by relaxation of the Si-Si network strain but it reveals a derelaxation of the bond angle strain. Since the state of relaxation after annealing is very similar for pure and hydrogenated materials, our results give strong experimental support to the predicted configurational gap between a-Si and crystalline silicon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A variable temperature field sets exacting demands to the structure under mechanical load. Most of all the lifetime of the rotating drum structure depends on temperature differences between parts inside the drum. The temperature difference was known because of the measurements made before. The list of demands was created based on customers’ needs. The limits of this paper were set to the inner structure of the drum. Creation of ideas for the inner structure was started open minded. The main principle in the creation process was to create new ideas for the function of the product with the help of sub-functions. The sub-functions were created as independent as possible. The best sub-functions were combined together and the new working principles were created based on them. Every working principle was calculated separately and criticized at the end of the calculation process. The main objective was to create the new kind of structure, which is not based too much to the old, inoperative structure. The affect of own weight of the inner structure to the stress values was quite small but it was also taken into consideration when calculating the maximum stress value of the structure. Because of very complex structures all of the calculations were made with the help of the ProE – Mechanica software. The fatigue analyze was made also for the best structure solution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this in vitro experimental study was to perform histological evaluation of the thermal effect produced on soft tissue irradiated with CO2, Er,Cr:YSGG or diode lasers. Study design: Porcine oral mucosa samples were irradiated with Er,Cr:YSGG laser at 1 W with and without water / air spray, at 2 W with and without water / air spray, and at 4 W with water / air spray, with CO2 laser at 1 W, 2 W, 10 W, 20 W continuous mode and 20 W pulsed mode and diode laser at 2W, 5W, and 10W pulsed mode. The thermal effect was evaluated measuring the width of damaged tissue adjacent to the incision, stained positively for hyalinized tissue with Hematoxylin-Eosin and Masson Trichrome stains. Besides, histological changes in the irradiated tissue were described using subjective grading scales. Results: The evaluated lasers developed a wide range of thermal damage with significant differences between groups. The samples with lowest thermal effect were those irradiated with Er,Cr:YSGG laser using water / air spray, followed by CO2 and diode lasers. Conclusions: Emission parameters of each laser system may influence the thermal damage inflicted on the soft tissue, however, the wave length of each laser determines the absorption rate characteristics of every tissue and the thermal effect

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, massive protostars have turned out to be a possible population of high-energy emitters. Among the best candidates is IRAS 16547-4247, a protostar that presents a powerful outflow with clear signatures of interaction with its environment. This source has been revealed to be a potential high-energy source because it displays non-thermal radio emission of synchrotron origin, which is evidence of relativistic particles. To improve our understanding of IRAS 16547-4247 as a high-energy source, we analyzed XMM-Newton archival data and found that IRAS 16547-4247 is a hard X-ray source. We discuss these results in the context of a refined one-zone model and previous radio observations. From our study we find that it may be difficult to explain the X-ray emission as non-thermal radiation coming from the interaction region, but it might be produced by thermal Bremsstrahlung (plus photo-electric absorption) by a fast shock at the jet end. In the high-energy range, the source might be detectable by the present generation of Cherenkov telescopes, and may eventually be detected by Fermi in the GeV range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this research is to explore the variability on the soil thermal conductivity -λ- after a prescribe fire, and to assess the effects of the ashes on the heat transfer once it"s were incorporated into the soil matrix. Sampling plot was located in the Montgrí Massif (NE of Spain). A set of 42 soil samples between surface and 5 cm depth was collected before and after the fire. To characterize the soil chemical and physical variables were analyzed. To determine the vari-ability on the soil λ a dry-out curve per scenario (before and after fire) was determined. SoilRho® method based on ASTM D-5334-08 which was validated by LabFerrer was used. Soil thermal conductivity has shown changes in their values. Indeed, in all moisture scenarios the values of soil λ decreased after soil was burnt. The critical point in the rela-tionship ϴ (λ) for the soil after fire which always was stronger than soil before to be burnt. Soil with"white" ashes showed a high thermal conductivity. An X-Ray diffractometry analysis allowed to clarify and to verify these results. To sum up, we could say that thermal conductivity presents changes when the scenario changes, i.e. before and after to be burnt. On the other hand, the volume of ashes incorporated on the soil increased the differences between no burnt and burnt soil, showing even some improvements on the heat transfer when water content started to govern the process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: An evaluation and comparison is made of the thermal increment at different implant surfaces during irradiation with CO2 and ErCr:YSGG lasers. Study design: Five threaded and impacted implants with four types of surfaces were inserted in an adult pig rib: two implants with a hydroxyapatite surface (HA)(impacted and threaded, respectively), a machined titanium surface implant (TI mach), a titanium plasma spray surface implant (TPS), and a sandblasted, acid-etched surface implant (SBAE). A 0.5-mm diameter bone defect was made in the implant apical zone, and a type-K thermocouple (Termopar)® was placed in contact with the implant. The implants were irradiated in the coronal zone of each implant with a CO2 (4 W continuous mode) and an ErCr:YSGG laser (1.5 W, pulsed mode) first without and then with refrigeration. The temperature variations at the implant apical surface were recorded. Results: An apical temperature increase was recorded in all cases during CO2 and ErCr:YSGG laser irradiation without refrigeration. However, when the ErCr:YSGG was used with a water spray, a decrease in temperature was observed in all implants. The acid-etched and sandblasted surfaces were those most affected by the thermal changes. Conclusions: The ErCr:YSGG laser with a water spray applied to the sealing cap or coronal zone of the implants does not generate thermal increments in the apical surface capable of adversely affecting osseointegration and the integrity of the peri-implant bone tissue

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Electroencephalogram (EEG) background reactivity is a potentially interesting outcome predictor in comatose patients, especially after cardiac arrest, but recent studies report only fair interrater reliability. Furthermore, there are no definite guidelines for its testing. We therefore investigated the EEG effect of standardized noxious stimuli in comatose patients not reactive to auditory stimuli. METHODS: In this prospective study we applied a protocol using three different painful stimuli (bilateral nipple pinching, pinprick at the nose base, finger-nail compression on each side), grouped in three distinct clusters with an alternated sequence, during EEG recordings in comatose patients. We only analyzed recordings showing any reactivity to pain. Fisher and χ2 tests were used as needed to assess contingency tables. RESULTS: Of 42 studies, 12 did not show any background reactivity, 2 presented SIRPIDs, and 2 had massive artefacts; we thus analyzed 26 EEGs recorded in 17 patients (4 women, 24%). Nipple pinching more frequently induced a change in EEG background activity (p<0.001), with a sensitivity of 97.4% for reactivity. Neither the order of the stimuli in the cluster (p=0.723), nor the cluster order (p=0.901) influenced the results. CONCLUSION: In this pilot study, bilateral, synchronous nipple pinching seems to be the most efficient method to test nociceptive EEG reactivity in comatose patients. This approach may enhance interrater reliability, but deserves confirmation in larger cohorts.