952 resultados para Secondary wastewater treatment
Resumo:
Water is a limited resource for which demand is growing. Contaminated water from inadequate wastewater treatment provides one of the greatest health challenges as it restricts development and increases poverty in emerging and developing countries. Therefore, the connection between wastewater and human health is linked to access to sanitation and to human waste disposal. Adequate sanitation is expected to create a barrier between disposed human excreta and sources of drinking water. Different approaches to wastewater management are required for different geographical regions and different stages of economic governance depending on the capacity to manage wastewater. Effective wastewater management can contribute to overcome the challenges of water scarcity. Separate collection of human urine at its source is one promising approach that strongly reduces the economic and load demands on wastewater treatment plants (WWTP). Treatment of source-separated urine appears as a sanitation system that is affordable, produces a valuable fertiliser, reduces pollution of water resources and promotes health. However, the technical realisation of urine separation still faces challenges. Biological hydrolysis of urea causes a strong increase of ammonia and pH. Under these conditions ammonia volatilises which can cause odour problems and significant nitrogen losses. The above problems can be avoided by urine stabilisation. Biological nitrification is a suitable process for stabilisation of urine. Urine is a highly concentrated nutrient solution which can lead to strong inhibition effects during bacterial nitrification. This can further lead to process instabilities. The major cause of instability is accumulation of the inhibitory intermediate compound nitrite, which could lead to process breakdown. Enhanced on-line nitrite monitoring can be applied in biological source-separated urine nitrification reactors as a sustainable and efficient way to improve the reactor performance, avoiding reactor failures and eventual loss of biological activity. Spectrophotometry appears as a promising candidate for the development and application of on-line nitrite monitoring. Spectroscopic methods together with chemometrics are presented in this work as a powerful tool for estimation of nitrite concentrations. Principal component regression (PCR) is applied for the estimation of nitrite concentrations using an immersible UV sensor and off-line spectra acquisition. The effect of particles and the effect of saturation, respectively, on the UV absorbance spectra are investigated. The analysis allows to conclude that (i) saturation has a substantial effect on nitrite estimation; (ii) particles appear to have less impact on nitrite estimation. In addition, improper mixing together with instabilities in the urine nitrification process appears to significantly reduce the performance of the estimation model.
Resumo:
Microbial electrolysis cells (MECs) are an innovative and emerging technique based on the use of solid-state electrodes to stimulate microbial metabolism for wastewater treatment and simultaneous production of value-added compounds (such as methane). This research studied the performance of a two-chamber MEC in terms of organic matter oxidation (at the anode) and methane production (at the cathode). MEC‟s anode had been previously inoculated with an activated sludge, whereas the cathode chamber inoculum was an anaerobic sludge (containing methanogenic microorganisms). During the experimentation, the bioanode was continuously fed with synthetic solutions in anaerobic basal medium, at an organic load rate (OLR) of around 1 g L-1 d-1, referred to the chemical oxygen demand (COD). At the beginning (Run I), the feeding solution contained acetate and subsequently (Run II) it was replaced with a more complex solution containing soluble organic compounds other than acetate. For both conditions, the anode potential was controlled at -0.1 V vs. standard hydrogen electrode, by means of a potentiostat. During Run I, over 80% of the influent acetate was anaerobically oxidized at the anode, and the resulting electric current was recovered as methane at the cathode (with a cathode capture efficiency, CCE, accounting around 115 %). The average energy efficiency of the system (i.e., the energy captured into methane relative to the electrical energy input) under these conditions was over 170%. However, reactor‟s performance decreased over time during this run. Throughout Run II, a substrate oxidation over 60% (on COD basis) was observed. The electric current produced (57% of coulombic efficiency) was also recovered as methane, with a CCE of 90%. For this run the MEC‟s average energy efficiency accounted for almost 170 %. During all the experimentation, a very low biomass growth was observed at the anode whereas ammonium was transferred through the cationic membrane and concentrated at the cathode. Tracer experiments and scanning electron microscopy analyses were also carried out to gain a deeper insight into the reactor performance and also to investigate the possible reasons for partial loss of performance. In conclusion, this research suggests the great potential of MEC to successfully treat low-strength wastewaters, with high energy efficiency and very low sludge production.
Resumo:
Magnetospirillum (M.) sp. strain Lusitani, a perchlorate reducing bacteria (PRB), was previously isolated from a wastewater treatment plant and phylogenetic analysis was performed to classify the isolate. The DNA sequence of the genes responsible for perchlorate reduction and chlorite dismutation was determined and a model was designed based on the physiological roles of the proteins involved in the pcr-cld regulon. Chlorite dismutase (Cld) was purified from Magnetospirillum sp. strain Lusitani cells grown in anaerobiosis in the presence of perchlorate. The protein was purified up to electrophoretic grade using HPLC techniques as a 140 kDa homopentamer comprising five ~28 kDa monomers. Steady-state kinetic studies showed that the enzyme follows a Michaelis-Menten model with optimal pH and temperature of 6.0 and 5°C, respectively. The average values for the kinetic constants KM and Vmax were respectively 0.56 mM and 10.2 U, which correspond to a specific activity of 35470 U/mg and a turnover number of 16552 s-1. Cld from M. sp. strain Lusitani is inhibited by the product chloride, but not by dioxygen. Inhibition constants KiC= 460 mM and KiU= 480 mM indicated that sodium chloride is a weak mixed inhibitor of Cld, with a slightly stronger competitive character. The X-ray crystallography structure of M. sp. strain Lusitani Cld was solved at 3.0 Å resolution. In agreement with cofactor content biochemical analysis, the X-ray data showed that each Cld monomer harbors one heme b coordinated by a histidine residue (His188), hydrogen-bonded to a conserved glutamic acid residue (Glu238). The conserved neighboring arginine residue (Arg201) important for substrate positioning, was found in two different conformations in different monomers depending on the presence of the exogenous ligand thiocyanate. UV-Visible and CW-EPR spectroscopies were used to study the effect of redox agents, pH and exogenous ligands on the heme environment.
Resumo:
Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Engenharia Clínica)
Resumo:
Dissertação de mestrado integrado em Engenharia Civil
Resumo:
Dissertação de mestrado integrado em Engenharia Civil
Resumo:
Report for the scientific sojourn carried out at the Model-based Systems and Qualitative Reasoning Group (Technical University of Munich), from September until December 2005. Constructed wetlands (CWs), or modified natural wetlands, are used all over the world as wastewater treatment systems for small communities because they can provide high treatment efficiency with low energy consumption and low construction, operation and maintenance costs. Their treatment process is very complex because it includes physical, chemical and biological mechanisms like microorganism oxidation, microorganism reduction, filtration, sedimentation and chemical precipitation. Besides, these processes can be influenced by different factors. In order to guarantee the performance of CWs, an operation and maintenance program must be defined for each Wastewater Treatment Plant (WWTP). The main objective of this project is to provide a computer support to the definition of the most appropriate operation and maintenance protocols to guarantee the correct performance of CWs. To reach them, the definition of models which represent the knowledge about CW has been proposed: components involved in the sanitation process, relation among these units and processes to remove pollutants. Horizontal Subsurface Flow CWs are chosen as a case study and the filtration process is selected as first modelling-process application. However, the goal is to represent the process knowledge in such a way that it can be reused for other types of WWTP.
Resumo:
Untreated wastewater being directly discharged into rivers is a very harmful environmental hazard that needs to be tackled urgently in many countries. In order to safeguard the river ecosystem and reduce water pollution, it is important to have an effluent charge policy that promotes the investment of wastewater treatment technology by domestic firms. This paper considers the strategic interaction between the government and the domestic firms regarding the investment in the wastewater treatment technology and the design of optimal effluent charge policy that should be implemented. In this model, the higher is the proportion of non-investing firms, the higher would be the probability of having to incur an effluent charge and the higher would be that charge. On one hand the government needs to impose a sufficiently strict policy to ensure that firms have strong incentive to invest. On the other hand, it cannot be too strict that it drives out firms which cannot afford to invest in such expensive technology. The paper analyses the factors that affect the probability of investment in this technology. It also explains the difficulty of imposing a strict environment policy in countries that have too many small firms which cannot afford to invest unless subsidised.
Resumo:
En este proyecto se ha desarrollado estrategias de control avanzadas para plantas de depuración de aguas residuales urbanas que eliminan conjuntamente materia orgánica, nitrógeno y fósforo. Las estrategias se han basado en el estudio multivariable del comportamiento del sistema, que ha producido subsidios para la utilización de lazos de control feedforward, de control predictivo y de un control de costes que automáticamente enviaba las consignas más adecuadas para los controladores de proceso. Para el desarrollo de las estrategias, se ha creado un sistema virtual de simulación (simulador) de plantas de depuradoras, basado en datos de literatura. Para el caso de una planta real, se ha desarrollado un simulador de la planta de Manresa (Catalunya). Sin embargo, el sistema de Manresa se ha utilizado exclusivamente para auxiliar los ingenieros de la planta en la tomada de decisiones de cambio de configuración para que la eliminación de fósforo se dé por la ruta biológica y no por la ruta química. La implementación de los simuladores ha permitido hacer muchas pruebas que en una planta real demandarían mucho tiempo y consumirían muchos recursos energéticos y financieros. Las estrategias de control más elaboradas han podido ahorrar hasta 150.000,00 Euros por año en relación a la operación de la planta sin el control automático. Cuanto a los estudios del modelo de la planta real, se concluyó que la eliminación biológica de fósforo puede sustituir el actual proceso químico de eliminación de fósforo, bajando los costes operacionales (costes del agente precipitante).
Resumo:
En el present estudi s’ha fet un seguiment baromètric de la producció de biogàs de tres compostos farmacèutics mitjançant tests de degradació anaeròbia. El llot del digestor anaerobi de l’estació depuradora d’aigües residuals (EDAR) de Granollers s’ha emprat com a inòcul. En un primer experiment, s’ha fet l’estudi de l’etapa metanogènica, amb metanol com a substrat i les concentracions de 5, 10 i 20 mg·L-1 d’àcid clofíbric (CLOFI, regulador lípid), ibuprofè (IBU, anti-inflamatori) i carbamazepina (CARBA, antiepilèptic/analgèsic). En un segon experiment, s’ha estudiat l’etapa acetogènica, amb àcid propiònic com a substrat i amb concentracions de 20 i 100 mg·L-1 dels mateixos fàrmacs. Per una banda, en el primer experiment, no s’ha observat degradació dels fàrmacs i cap d’ells presenta toxicitat pel llot anaerobi. CARBA i IBU s’adsorbeixen majoritàriament a la fase sòlida. Per altra banda, en l’etapa acetogènica ni CARBA ni IBU s’han degradat i tampoc presenten toxicitat en cap de les concentracions provades. Com en el cas anterior, la majoria d’aquests fàrmacs queda adsorbit en el llot. En canvi, CLOFI es degrada en 100 mg·L-1 de concentració donant com a producte intermedi un metabòlit.
Resumo:
La determinació de compostos orgànics contaminants en aigües residuals d’origen urbà i industrial és un tema que ha suscitat un creixent interès, tant des del punt de vista del problema mediambiental que es deriva de l’abocament d’aquestes aigües al medi aquàtic públic com des de la perspectiva de reutilització de les aigües tractades en processos industrials. La majoria d’aquests contaminants no s’eliminen completament en plantes de tractament d’aigües convencionals, pel que s’han de controlar. Aquest fet implica desenvolupar nous processos de tractament que permetin millorar l'eficiència de l'eliminació de les plantes de tractament convencionals. Per tal d'investigar la presència d'aquests compostos contaminants a baixes concentracions és necessari desenvolupar nous mètodes analítics altament sensibles. En el nostre projecte s'han desenvolupat diferents mètodes analítics per determinar compostos orgànics contaminants en aigües residuals provinents de plantes de tractament d'aigües industrials, urbanes i plantes potabilitzadores, utilizant principalment la microextracció en fase sòlida (SPME) seguida de la cromatografia de gasos acoblada a un espectròmetre de masses (GC-MS). S'ha estudiat la presència de diferents famílies de compostos en aquestes aigües, com són: ftalats, amines alifàtiques primàries i nitrosamines. A més a més, s'han desenvolupat mètodes analítics per determinar amines alifàtiques primàries en llots actius provinents de diferents tipus de plantes de tractament d'aigües i plantes potabilitzadores.
Resumo:
L’aigua i l’energia formen un binomi indissociable. En relació al cicle de l’aigua, des de fa varies dècades s’han desenvolupat diferents formes per recuperar part de l’energia relacionada amb l’aigua, per exemple a partir de centrals hidroelèctriques. No obstant, l’ús d’aquesta aigua també porta associat un gran consum energètic, relacionat sobretot amb el transport, la distribució, la depuració, etc... La depuració d’aigües residuals porta associada una elevada demanda energètica (Obis et al.,2009). En termes energètics, tot i que la despesa elèctrica d’una EDAR varia en funció de diferents paràmetres com la configuració i la capacitat de la planta, la càrrega a tractar, etc... es podria considerar que el rati mig seria d’ aproximadament 0.5 KWh•m-3.Els principals costos d’explotació estan relacionats tant amb la gestió de fangs (28%) com amb el consum elèctric (25%) (50% tractament biològic). Tot i que moltes investigacions relacionades amb el tractament d’aigua residual estan encaminades en disminuir els costos d’operació, des de fa poques dècades s’està investigant la viabilitat de que l’aigua residual fins i tot sigui una font d’energia, canviant la perspectiva, i començant a veure l’aigua residual no com a una problemàtica sinó com a un recurs. Concretament s’estima que l’aigua domèstica conté 9.3 vegades més energia que la necessària per el seu tractament mitjançant processos aerobis (Shizas et al., 2004). Un dels processos més desenvolupats relacionats amb el tractament d’aigües residuals i la producció energètica és la digestió anaeròbia. No obstant, aquesta tecnologia permet el tractament d’altes càrregues de matèria orgànica generant un efluent ric en nitrogen que s’haurà de tractar amb altres tecnologies. Per altre banda, recentment s’està investigant una nova tecnologia relacionada amb el tractament d’aigües residuals i la producció energètica: les piles biològiques (microbial fuel cells, MFC). Aquesta tecnologia permet obtenir directament energia elèctrica a partir de la degradació de substrats biodegradables (Rabaey et al., 2005). Les piles biològiques, més conegudes com a Microbial Fuel Cells (acrònim en anglès, MFC), són una emergent tecnologia que està centrant moltes mirades en el camp de l’ investigació, i que es basa en la producció d’energia elèctrica a partir de substrats biodegradables presents en l’aigua residual (Logan., 2008). Els fonaments de les piles biològiques és molt semblant al funcionament d’una pila Daniell, en la qual es separa en dos compartiments la reacció d’oxidació (compartiment anòdic) i la de reducció (compartiment catòdic) amb l’objectiu de generar un determinat corrent elèctric. En aquest estudi, bàsicament es mostra la posada en marxa d'una pila biològica per a l'eliminació de matèria orgànica i nitrogen de les aigües residuals.
Resumo:
The presence of enteric viruses in biosolids can be underestimated due to the inefficient methods (mainly molecular methods) used to recover the viruses from these matrices. Therefore, the goal of this study was to evaluate the different methods used to recover adenoviruses (AdV), rotavirus species A (RVA), norovirus genogroup II (NoV GII) and the hepatitis A virus (HAV) from biosolid samples at a large urban wastewater treatment plant in Brazil after they had been treated by mesophilic anaerobic digestion. Quantitative polymerase chain reaction (PCR) was used for spiking experiments to compare the detection limits of feasible methods, such as beef extract elution and ultracentrifugation. Tests were performed to detect the inhibition levels and the bacteriophage PP7 was used as an internal control. The results showed that the inhibitors affected the efficiency of the PCR reaction and that beef extract elution is a suitable method for detecting enteric viruses, mainly AdV from biosolid samples. All of the viral groups were detected in the biosolid samples: AdV (90%), RVA, NoV GII (45%) and HAV (18%), indicating the viruses' resistance to the anaerobic treatment process. This is the first study in Brazil to detect the presence of RVA, AdV, NoV GII and HAV in anaerobically digested sludge, highlighting the importance of adequate waste management.
Resumo:
L'existència d’una font de carboni adequada per l’eliminació biològica de fòsfor, és un factor decisiu per l'eliminació de fòsfor de les aigües residuals urbanes. Per a les aigües residuals amb baix contingut d'àcids grassos volàtils és necessària l’addició d’alguna font de carboni externa. El metanol és la font de carboni més utilitzada en processos a EDAR (p.ex. desnitrificació), degut al seu baix cost. Malgrat això, varis estudis proven que per l’eliminació biològica de fòsfor, aquest, no és una bona alternativa. En aquest estudi es desenvolupa un consorci amb la biomassa de digestió anaeròbia i biomassa acumuladora de polifosfat (PAO). El propòsit del consorci és la degradació de metanol en AGV, per obtenir l'activitat EBPR. A més, aquest estudi mostra la viabilitat de substituir en el consorci el metanol per altres fonts de carboni.
Resumo:
Set the maximum percentage of federal funds allotted to Iowa that may be spent on municipal Wastewater treatment works at 20%.