913 resultados para Reduction of secondary amides
Resumo:
This work presents a comprehensive methodology for the reduction of analytical or numerical stochastic models characterized by uncertain input parameters or boundary conditions. The technique, based on the Polynomial Chaos Expansion (PCE) theory, represents a versatile solution to solve direct or inverse problems related to propagation of uncertainty. The potentiality of the methodology is assessed investigating different applicative contexts related to groundwater flow and transport scenarios, such as global sensitivity analysis, risk analysis and model calibration. This is achieved by implementing a numerical code, developed in the MATLAB environment, presented here in its main features and tested with literature examples. The procedure has been conceived under flexibility and efficiency criteria in order to ensure its adaptability to different fields of engineering; it has been applied to different case studies related to flow and transport in porous media. Each application is associated with innovative elements such as (i) new analytical formulations describing motion and displacement of non-Newtonian fluids in porous media, (ii) application of global sensitivity analysis to a high-complexity numerical model inspired by a real case of risk of radionuclide migration in the subsurface environment, and (iii) development of a novel sensitivity-based strategy for parameter calibration and experiment design in laboratory scale tracer transport.
Resumo:
Das aSPECT Spektrometer wurde entworfen, um das Spektrum der Protonen beimrnZerfall freier Neutronen mit hoher Präzision zu messen. Aus diesem Spektrum kann dann der Elektron-Antineutrino Winkelkorrelationskoeffizient "a" mit hoher Genauigkeit bestimmt werden. Das Ziel dieses Experiments ist es, diesen Koeffizienten mit einem absoluten relativen Fehler von weniger als 0.3% zu ermitteln, d.h. deutlich unter dem aktuellen Literaturwert von 5%.rnrnErste Messungen mit dem aSPECT Spektrometer wurden an der Forschungsneutronenquelle Heinz Maier-Leibnitz in München durchgeführt. Jedoch verhinderten zeitabhängige Instabilitäten des Meßhintergrunds eine neue Bestimmung von "a".rnrnDie vorliegende Arbeit basiert hingegen auf den letzten Messungen mit dem aSPECTrnSpektrometer am Institut Laue-Langevin (ILL) in Grenoble, Frankreich. Bei diesen Messungen konnten die Instabilitäten des Meßhintergrunds bereits deutlich reduziert werden. Weiterhin wurden verschiedene Veränderungen vorgenommen, um systematische Fehler zu minimieren und um einen zuverlässigeren Betrieb des Experiments sicherzustellen. Leider konnte aber wegen zu hohen Sättigungseffekten der Empfängerelektronik kein brauchbares Ergebnis gemessen werden. Trotzdem konnten diese und weitere systematische Fehler identifiziert und verringert, bzw. sogar teilweise eliminiert werden, wovon zukünftigernStrahlzeiten an aSPECT profitieren werden.rnrnDer wesentliche Teil der vorliegenden Arbeit befasst sich mit der Analyse und Verbesserung der systematischen Fehler, die durch das elektromagnetische Feld aSPECTs hervorgerufen werden. Hieraus ergaben sich vielerlei Verbesserungen, insbesondere konnten die systematischen Fehler durch das elektrische Feld verringert werden. Die durch das Magnetfeld verursachten Fehler konnten sogar soweit minimiert werden, dass nun eine Verbesserung des aktuellen Literaturwerts von "a" möglich ist. Darüber hinaus wurde in dieser Arbeit ein für den Versuch maßgeschneidertes NMR-Magnetometer entwickelt und soweit verbessert, dass nun Unsicherheiten bei der Charakterisierung des Magnetfeldes soweit reduziert wurden, dass sie für die Bestimmung von "a" mit einer Genauigkeit von mindestens 0.3% vernachlässigbar sind.
Resumo:
This project was born with the aim of developing an environmentally and financially sustainable process to dispose of end-life tires. In this perspective was devised an innovative static bed batch pilot reactor where pyrolysis can be carried out on the whole tires in order to recover energy and materials and simultaneously save the energy costs of their shredding. The innovative plant is also able to guarantee a high safety of the process thanks to the presence of a hydraulic guard. The pilot plant was used to pyrolyze new and end-life tires at temperatures from 400 to 600°C with step of 50°C in presence of steam. The main objective of this research was to evaluate the influence of the maximum process temperature on yields and chemical-physics properties of pyrolysis products. In addition, in view of a scale-up of the plant in continuous mode, the influence of the nature of several different tires as well as the effects of the aging on the final products were studied. The same pilot plant was also used to carry out pyrolysis on polymeric matrix composites in order to obtain chemical feedstocks from the resin degradation together with the recovery of the reinforcement in the form of fibers. Carbon fibers reinforced composites ad fiberglass was treated in the 450-600°C range and the products was fully characterized. A second oxidative step was performed on the pyrolysis solid residue in order to obtain the fibers in a suitable condition for a subsequent re-impregnation in order to close the composite Life Cycle in a cradle-to-cradle approach. These investigations have demonstrated that steel wires, char, carbon and glass fibers recovered in the prototypal plant as solid residues can be a viable alternative to pristine materials, making use of them to obtain new products with a commercial added value.
Resumo:
Nowadays the number of hip joints arthroplasty operations continues to increase because the elderly population is growing. Moreover, the global life expectancy is increasing and people adopt a more active way of life. For this reasons, the demand of implant revision operations is becoming more frequent. The operation procedure includes the surgical removal of the old implant and its substitution with a new one. Every time a new implant is inserted, it generates an alteration in the internal femur strain distribution, jeopardizing the remodeling process with the possibility of bone tissue loss. This is of major concern, particularly in the proximal Gruen zones, which are considered critical for implant stability and longevity. Today, different implant designs exist in the market; however there is not a clear understanding of which are the best implant design parameters to achieve mechanical optimal conditions. The aim of the study is to investigate the stress shielding effect generated by different implant design parameters on proximal femur, evaluating which ranges of those parameters lead to the most physiological conditions.
Resumo:
BACKGROUND: Atrial fibrillation (AF) is a significant risk factor for cardiovascular (CV) mortality. This study aims to evaluate the prognostic implication of AF in patients with peripheral arterial disease (PAD). METHODS: The International Reduction of Atherothrombosis for Continued Health (REACH) Registry included 23,542 outpatients in Europe with established coronary artery disease, cerebrovascular disease (CVD), PAD and/or >/=3 risk factors. Of these, 3753 patients had symptomatic PAD. CV risk factors were determined at baseline. Study end point was a combination of cardiac death, non-fatal myocardial infarction (MI) and stroke (CV events) during 2 years of follow-up. Cox regression analysis adjusted for age, gender and other risk factors (i.e., congestive heart failure, coronary artery re-vascularisation, coronary artery bypass grafting (CABG), MI, hypertension, stroke, current smoking and diabetes) was used. RESULTS: Of 3753 PAD patients, 392 (10%) were known to have AF. Patients with AF were older and had a higher prevalence of CVD, diabetes and hypertension. Long-term CV mortality occurred in 5.6% of patients with AF and in 1.6% of those without AF (p<0.001). Multivariable analyses showed that AF was an independent predictor of late CV events (hazard ratio (HR): 1.5; 95% confidence interval (CI): 1.09-2.0). CONCLUSION: AF is common in European patients with symptomatic PAD and is independently associated with a worse 2-year CV outcome.
Resumo:
When healthy observers make a saccade that is erroneously directed toward a distracter stimulus, they often produce a corrective saccade within 100ms after the end of the primary saccade. Such short inter-saccadic intervals indicate that programming of the secondary saccade has been initiated prior to the execution of the primary saccade and hence that the two saccades have been programmed concurrently. Here we show that concurrent saccade programming is bilaterally impaired in left spatial neglect, a strongly lateralized disorder of visual attention resulting from extensive right cerebral damage. Neglect patients were asked to make saccades to targets presented left or right of fixation while disregarding a distracter presented in the opposite hemifield. We examined those experimental trials on which participants first made a saccade to the distracter, followed by a secondary (corrective) saccade to the target. Compared to healthy and right-hemisphere damaged control participants the proportion of secondary saccades directing gaze to the target instead of bringing it even closer to the distracter was bilaterally reduced in neglect patients. In addition, the characteristic reduction of secondary saccade latency observed in both control groups was absent in neglect patients, whether the secondary saccade was directed to the left or right hemifield. This pattern is consistent with a severe, bilateral impairment of concurrent saccade programming in left spatial neglect.
Resumo:
This study evaluated the performance of the DIAGNOdent pen laser fluorescence device (LFpen) in comparison with visual examination (VE), bitewing radiographs (BW) and visual examination combined with bitewing radiographs (VEBW) in detecting secondary approximal caries associated with composite restorations. In total, 60 approximal surfaces from 43 permanent molars with composite restorations were assessed twice by two examiners using the LFpen, VE, BW and VEBW. After histological preparation and hardness measurements, the sample was assigned to either a crown or root caries group, depending on the location of the lesions as the gold standard. For crown caries at D1, the highest values of specificity and sensitivity were observed for the LFpen at a cutoff value of 18 (1.00) and for the VEBW (0.89). At D3 (cutoff of 30), the LFpen showed the highest values of sensitivity and specificity. For root caries, the LFpen and VEBW showed the highest values of specificity (0.54), sensitivity (0.81) and accuracy (0.69). The Spearman rank correlation coefficients for crown/root caries with histology were 0.54/0.37 (LFpen), 0.29/0.10 (BW), 0.29/0.18 (VE) and 0.23/0.37 (VEBW). For the LFpen, the ICC varied from 0.80 (interexaminer) to 0.97 (intraexaminer B); the kappa value was 0.19 for BW and 0.35 for VE (interexaminer). Intraexaminer kappa values for BW were 0.25 (A) and 0.29 (B), and those for VE were 0.31 (A) and 0.32 (B). The LFpen device exhibited a performance comparable to that of conventional methods but with higher interexaminer reproducibility. Therefore, the LFpen should be considered an auxiliary method for the detection of secondary approximal caries associated with composite restorations.
Resumo:
Background: Medication-related problems are common in the growing population of older adults and inappropriate prescribing is a preventable risk factor. Explicit criteria such as the Beers criteria provide a valid instrument for describing the rate of inappropriate medication (IM) prescriptions among older adults. Objective: To reduce IM prescriptions based on explicit Beers criteria using a nurse-led intervention in a nursing-home (NH) setting. Study Design: The pre/post-design included IM assessment at study start (pre-intervention), a 4-month intervention period, IM assessment after the intervention period (post-intervention) and a further IM assessment at 1-year follow-up. Setting: 204-bed inpatient NH in Bern, Switzerland. Participants: NH residents aged ≥60 years. Intervention: The intervention included four key intervention elements: (i) adaptation of Beers criteria to the Swiss setting; (ii) IM identification; (iii) IM discontinuation; and (iv) staff training. Main Outcome Measure: IM prescription at study start, after the 4-month intervention period and at 1-year follow-up. Results: The mean±SD resident age was 80.3±8.8 years. Residents were prescribed a mean±SD 7.8±4.0 medications. The prescription rate of IMs decreased from 14.5% pre-intervention to 2.8% post-intervention (relative risk [RR] = 0.2; 95% CI 0.06, 0.5). The risk of IM prescription increased nonstatistically significantly in the 1-year follow-up period compared with post-intervention (RR = 1.6; 95% CI 0.5, 6.1). Conclusions: This intervention to reduce IM prescriptions based on explicit Beers criteria was feasible, easy to implement in an NH setting, and resulted in a substantial decrease in IMs. These results underscore the importance of involving nursing staff in the medication prescription process in a long-term care setting.
Resumo:
To establish an education and training programme for the reduction of CT radiation doses and to assess this programme's efficacy.
Resumo:
To examine the impact of cardiovascular risk factor control on 3-year cardiovascular event rates in patients with stable symptomatic atherothrombotic disease in Europe.
Resumo:
Mechanistic investigations on the previously reported reduction of B-alkylcatecholboranes in the presence of methanol led to the disclosure of a new mechanism involving catechol as a reducing agent. More than just revising the mechanism of this reaction, we disclose here the surprising role of catechol, a chain breaking antioxidant, which becomes a source of hydrogen atoms in an efficient radical chain process
Resumo:
The widespread use of artificial nestboxes has led to significant advances in our knowledge of the ecology, behaviour and physiology of cavity nesting birds, especially small passerines Nestboxes have made it easier to perform routine monitoring and experimental manipulation of eggs or nestlings, and also repeatedly to capture, identify and manipulate the parents However, when comparing results across study sites the use of nestboxes may also Introduce a potentially significant confounding variable in the form of differences in nestbox design amongst studies, such as their physical dimensions, placement height, and the way in which they are constructed and maintained However, the use of nestboxes may also introduce an unconsidered and potentially significant confounding variable clue to differences in nestbox design amongst studies, such as their physical dimensions, placement height, and the way in which they are constructed and maintained Here we review to what extent the characteristics of artificial nestboxes (e g size, shape, construction material, colour) are documented in the 'methods' sections of publications involving hole-nesting passerine birds using natural or excavated cavities or artificial nestboxes for reproduction and roosting Despite explicit previous recommendations that authors describe in detail the characteristics of the nestboxes used, we found that the description of nestbox characteristics in most recent publications remains poor and insufficient We therefore list the types of descriptive data that should be included in the methods sections of relevant manuscripts and justify this by discussing how variation in nestbox characteristics can affect or confound conclusions from nestbox studies We also propose several recommendations to improve the reliability and usefulness of research based on long-term studies of any secondary hole-nesting species using artificial nestboxes for breeding or roosting.
Resumo:
We evaluated mechanisms of failure and outcome of secondary surgical interventions after thoracic endovascular aortic repair (TEVAR).