498 resultados para Radiografia : Maxilares
Resumo:
Computed Radiography (CR) is a term used to describe the system that electronically records a radiographic image. CR systems use receivers or IP (imaging plate) to capture the analog signals and then allow the readers to do the image processing and converted into digital information. With the increasing expansion of the CR for medical diagnostics it is necessary that these systems receive the same type of monitoring related to Quality Control and Acceptance to the conventional processing systems. The current legislation fails to specify the parameters and procedures to be tested, allowing that somehow, some equipment is not fully able to use in clinical routine. In this project we used the standard AAPM Report Number 93, which is already fully established outside the country and displays all test parameters in CR. From there were chosen three types of tests that were performed in a satisfactory sampling of IP´s. With this procedure it was possible to establish which of those IP's should be out of use, which reveals the important purpose of the study, demonstrating the need for Quality Control Testing and Acceptance in Computerized Radiography as soon as possible are included in the legislation regulator in the country
Resumo:
The purpose of this work is to provide quality control requirements and security in dental x-rays in order to obtain good quality image which allows the correct diagnosis, which reduces the dose to the patient, mainly due to the repetition of tests, and decreasing cost. The requirements apply to related activities to quality control and procedures using ionizing radiation for diagnostic imaging in dentistry by evaluating a minimum set of parameters to be tested or verified. Quality control follows the Ordinance No. 453 of the Ministry of Health of 06.01.1998, SS Resolution No. 625 of 12.14.1994 and Resolution No. 64 of the Health Surveillance Center – Department of Health of Sao Paulo and National Health Surveillance Agency – Ministry of Health of Brazil. This study was conducted in the city of Marilia, Sao Paulo, along with the Company P&R Consulting and Medical Physics, in a dental clinic of the University UNIMAR in the x-ray equipment used on that site. The physical parameters of the device were tested with the aid of ionization chambers to measure rates of radiation, electrometer to measure rates of time, kV and doses, radiographic films and positioning devices. Finally, this work demonstrates the need and importance of quality control, which one ensures the proper use of x-ray machines, maintaining efficiency and at the same time it reduces the risks to the patient, to the dentist and to the general public
Resumo:
A proposta desse trabalho surgiu da possibilidade de unir metodologias eficientes para estabelecer valores mais precisos de densitometria óssea. A densidade óssea é um parâmetro biofísico de grande importância experimental e clínica, que permite avaliar o processo de mineralização óssea. O objetivo deste trabalho foi determinar a densidade óssea e o coeficiente de atenuação de massa da radiação gama com o radioisótopo 241Am com fotopico de 59,6 keV em rádios de cães SRD (Sem Raça Definida). Conclui-se a que a densidade média das amostras foi de 1,91 g/cm³ com um desvio padrão de 0,0599. Para o coeficiente de atenuação de massa, o valor médio foi de 0,241 cm2/g, com desvio padrão de 0,0151. Para ambos os parâmetros o coeficiente de variação foi pequeno implicando em uma baixa dispersão. Isso também demonstra que os métodos aplicados foram eficientes e de fácil aplicabilidade
Resumo:
The progress in radiology is related with the development of new systems of image formation with the lesser dose in the pacient. The improve of the dose in the pacient, without compromising the quality of the image, is one of the responsibilities of a medical physicist in a sector of diagnosis for image. This research has as objective to evaluate the conditions of use of an equipment of x-rays, from tests of quality control. The results gotten in this work have been part of data of an Effective Program of Quality Control (PECQ) of the sector of diagnosis for image of the Hospital das Clínicas da Faculdade de Medicina de Botucatu - UNESP (HCFMB-UNESP)
Resumo:
The maxillary lateral incisor has a very peculiar and internal morphology that can be influenced by the its external anatomy such as supernumerary roots and ruts deep root, which often hinders an effective endodontic treatment. Generally, this tooth have a single root with one root canal, but teeth with two to four channels can be found. The main canal can present ramifications such as accessory canals, laterals, collaterals, recorrents and apical deltas. All this factors interfere directally on endodonthics treatment. The objective of this work is a study of the internal anatomy of the maxillary lateral incisors by digital and conventional radiographics methods, comparing the results obteined by each method Six hundred upper lateral incisor were used in this study teeth of the collection of the Department of Anatomy ICT – UNESP. All the teeth were radiographed by vestibular face, using a digital radiographic unit(Dabi Atlante). After this step, all the teeth underwent by conventional radiographic technique(Kodak 2200) so that the results obtained were compared. To classify the channel system, it was adopted the classification of Pucci and Reig. All data obtained by digital technique were compared with those obtained in the conventional technique and were subjected to statistical analysis
Resumo:
Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Biopatologia Bucal - ICT
Imunomarcação da OPG e RANKL no reparo ósseo após a cirurgia de elevação do seio maxilar com Bio-Oss
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
O exame radiográfico é um procedimento simples e relativamente barato que pode ser utilizado para observação de estruturas ósseas e tecidos moles, incluindo suas alterações, sendo muito empregado em casos de suspeita de aumento de volume ósseo devido a tumores e inflamações. Osteossarcoma e osteomielite, além de causarem a alteração radiográfica acima citada, possuem imagem radiográfica muito semelhante na maioria dos casos, como proliferação e/ou lise óssea, presença do triângulo de Codman e perda do padrão trabecular ósseo, além de sintomas clínicos similares como claudicação e possível presença de fraturas patológicas. A necessidade de se realizar outros métodos de exame complementar paralelos à radiografia é muito importante na determinação de um diagnóstico seguro, o que implica em um tratamento precoce da doença evitando-se assim grande piora no estado geral do paciente. Esta revisão sistemática de literatura visa a comparação radiográfica entre osteomielite e osteossarcoma em cães, para auxilio do médico veterinário na diferenciação de seu diagnóstico.
Resumo:
The purpose of this study was to evaluate the accuracy of the depth of carious lesions on bitewing radiographs. Methods Recently extracted primary molars had their proximal surfaces evaluated visually (EC) and classified as healthy surface (0), signs that suggest the presence of carious lesions in enamel (1), signs of a superficial lesion in dentin (2) and carious lesions in deep dentin (3). Results The results were obtained by consensus between the investigators. The gold standard was determined by histological analysis. The values of sensitivity, specificity, accuracy and area under the ROC (Receiver Operating Characteristic) curve were evaluated. There was equilibrium between sensitivity (76.92% EC and 88.46% ER) and specificity (95.83% EC and 95.83% ER). Accuracy was 86.01% (EC) and 88.46% (ER). The Spearman correlation test was used to prove the correlation between clinical and radiographic examinations (0.886), for clinical and histological (0.736) and for radiographic and histological analysis (0.843).
Resumo:
The pattern of caries lesions has been modified over decades. If the presence or absence of a caries lesion is based upon only a visual examination, its diagnosis might become underestimated since dentinal lesions underneath non cavitated or minimally demineralized enamel is highly frequent in dental clinics. The aim of this paper is to report a clinical case of a child with an upper molar with questionable occlusal aspect, presenting asymptomatic pulpal hyperplasia on the distolingual pit. Periapical radiographic examination was essential for diagnosing hidden caries and elaborating the treatment plan. As part of the approach, removal of the decayed tissue and pulpotomy with calcium hydroxide were performed. The association of an accurate visual examination to an adequate oral radiographyis is extremely important in cases which the presence of hidden caries is doubtful. As a result, an early diagnosis and the reduction of more invasive interventions related to the oral health care of pediatric patients can be achieved as well.