846 resultados para Radio-frequency power


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Photoionization of hydrogen atoms in few-cycle laser pulses is studied numerically. The total ionization probability, the. instantaneous ionization probability; and the partial ionization probabilities in a pair of opposite directions are obtained. The partial ionization probabilities are not always equal to each other which is termed as inversion asymmetry. The variation of asymmetry degree with the CE phase, the pulse duration and the pulse intensity is studied. It is found that the pulse intensity affects the asymmetry degree in many aspects. Firstly, the asymmetry is more distinct at higher intensities than that at lower intensities when the pulse duration exceeds 4 cycles; secondly, the maximal asymmetry in lower intensities varies with the CE phase visibly while at higher intensities riot; thirdly, the partial ionization probabilities equal to each other for some special CE phases. For lower pulse intensities, the corresponding value of CE phase is always 0.5 pi and 1.5 pi, while for higher pulse intensities, the corresponding value varies with the pulse intensity. Similar phenomena were observed in a recent experiment using few-cycle radio-frequency (RF) pulses.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

单纵模掺铒光纤激光器在光通信和光传感等方面有着广泛的应用前景。设计了一种新型的光纤激光器,在光纤环形镜中嵌入未抽运的掺铒光纤作为可饱和吸收体以抑制多纵模,用光纤环谐振腔作为滤波器抑制拍频噪声,用光纤光栅作为波长选择器件,最终得到了单纵模输出并消除了拍频噪声。使用零拍法测量其线宽小于频谱仪的低频极限5kHz。实验结果证明了可饱和吸收体和光纤环的功能。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

[ES]En este trabajo se ha diseñado un producto secundario con una fijación extra en formato trocar para operaciones percutáneas dirigidas por sistemas de imagen. Este instrumento que hasta ahora era inexistente en el mercado actuará como túnel, permitiendo la introducción de agujas de radiofrecuencia y biopsia por su interior. La particularidad de este producto es el diseño del sistema de sujeción, que garantizará al cirujano que el punto a intervenir sea el mismo durante toda la operación. Este diseño se ha realizado después de hacer un estudio en profundidad de las alternativas existentes de los sistemas de fijación en el campo de la medicina oncológica y el sector industrial. Además se detalla el material de cada elemento del producto en base a la norma sanitaria correspondiente, también se explica el proceso más adecuado para la fabricación de dichos elementos y por último se realiza un cálculo sencillo del pandeo de la aguja, que garantice un uso óptimo del instrumento.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

LLRF sistema baten deskribapena eta simulaketa

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nesta dissertação são analisados métodos de localização baseados na rede, com destaque para os métodos de correlação de assinaturas de rádio-frequência (DCM - Database Correlation Methods). Métodos baseados na rede não requerem modificações nos terminais móveis (MS - Mobile Stations), sendo portanto capazes de estimar a localização de MS legados, i.e., sem suporte específico a posicionamento. Esta característica, associada a alta disponibilidade e precisão dos métodos DCM, torna-os candidatos viáveis para diversas aplicações baseadas em posição, e em particular para a localização de chamadas para números de emergência - polícia, defesa civil, corpo de bombeiros, etc. - originadas de telefones móveis celulares. Duas técnicas para diminuição do tempo médio para produção de uma estimativa de posição são formuladas: a filtragem determinística e a busca otimizada utilizando algoritmos genéticos. Uma modificação é realizada nas funções de avaliação utilizadas em métodos DCM, inserindo um fator representando a inacurácia intrínseca às medidas de nível de sinal realizadas pelos MS. As modificações propostas são avaliadas experimentalmente em redes de telefonia móvel celular de segunda e terceira gerações em ambientes urbanos e suburbanos, assim como em redes locais sem fio em ambiente indoor. A viabilidade da utilização de bancos de dados de correlação (CDB - Correlation Database) construídos a partir de modelagem de propagação é analisada, bem como o efeito da calibração de modelos de propagação empíricos na precisão de métodos DCM. Um dos métodos DCM propostos, utilizando um CDB calibrado, teve um desempenho superior ao de vários outros métodos DCM publicados na literatura, atingindo em área urbana a precisão exigida dos métodos baseados na rede pela regulamentação FCC (Federal Communications Commission) para o serviço E911 (Enhanced 911 ).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Na medicina regenerativa há uma crescente utilização de lasers de baixa intensidade em protocolos terapêuticos para tratamento de doenças em tecidos moles e no tecido ósseo. Lasers emitem feixes de luz com características específicas, nas quais o comprimento de onda, a frequência, potência e modo de missão são propriedades determinantes para as respostas fotofísica, fotoquímica e fotobiológica. Entretanto, sugere-se que lasers de baixa potência induzem a produção de radicais livres, que podem reagir com biomoléculas importantes, como o DNA. Essas reações podem causar lesões e induzir mecanismos de reparo do DNA para preservar a integridade do código genético e homeostase celular. Portanto, o objetivo deste trabalho foi avaliar lesões no DNA de células do sangue periférico de ratos Wistar e a expressão dos genes ERCC1 e ERCC2 em tecidos biológicos expostos a lasers de baixa intensidade em comprimentos de onda, fluências, potências e modos de emissão utilizados em protocolos terapêuticos. Para tal, amostras de sangue periférico foram expostas ao laser vermelho (660 nm) e infravermelho (808 nm) em diferentes fluências, potências e modos de emissão, e a indução de lesões no DNA foi avaliada através do ensaio cometa. Em outros experimentos, lesões no DNA foram analisadas através do ensaio cometa modificado, utilizando as enzimas de reparo: formamidopirimidina DNA glicosilase (FPG) e endonuclease III. Pele e músculo de ratos Wistar foram expostos aos lasers e amostras desses tecidos foram retiradas para extração de RNA, síntese de cDNA e avaliação da expressão dos genes por PCR quantitativo em tempo real. Os dados obtidos neste estudo sugeriram que a exposição aos lasers induz lesões no DNA dependendo da fluência, potência e modo de emissão, e que essas lesões são alvos da FPG e endonuclease III. A expressão relativa do RNAm de ERCC1 e de ERCC2 foi alterada nos tecidos expostos dependendo do comprimento de onda e fluência utilizada. Os resultados obtidos neste estudo sugerem que danos oxidativos no DNA poderiam ser considerados para segurança do paciente e eficácia terapêutica, bem como alterações na expressão dos genes de reparo do DNA participariam dos efeitos de bioestimulação que justificam as aplicações terapêutica de lasers de baixa potência.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A technique for pattern transfer onto carbon-diamond films deposited by radio-frequency plasma-enhanced chemical vapour deposition is reported. Such a technique involves standard photolithography processes and reactive ion etching by oxygen and is compatible with present day microelectronic technology. The patterns transferred are well defined with very good resolution. © 1992.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mixed phase carbon-diamond films which consist of small grain diamond in an a:C matrix were deposited on polished Si using a radio frequency CH4 Ar plasma CVD deposition process. Ellipsometry, surface profilometry, scanning electron microscopy (SEM) and spectrophotometry were used to analyse these films. Film thicknesses were typically 50-100 nm with a surface roughness of ± 30 A ̊ over centimetre length scans. SEM analysis showed the films were smooth and pinhole free. The Si substrate was etched using backside masking and a directional etch to give taut carbon-diamond membranes on a Si grid. Spectrophotometry was used to analyse the optical properties of these membranes. Band gap control was achieved by varying the dc bias of the deposition process. Band gaps of 1.2 eV to 4.0 eV were achieved in these membranes. A technique for controlling the compressive stress in the films, which can range from 0.02 to 7.5 GPa has been employed. This has allowed the fabrication of thin, low stress, high band gap membranes that are extremely tough and chemically inert. Such carbon-diamond membranes seem promising for applications as windows in analytical instruments. © 1992.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the field of flat panel displays, the current leading technology is the Active Matrix liquid Crystal Display; this uses a-Si:H based thin film transistors (TFTs) as the switching element in each pixel. However, under gate bias a-Si:H TFTs suffer from instability, as is evidenced by a shift in the gate threshold voltage. The shift in the gate threshold voltage is generally measured from the gate transfer characteristics, after subjecting the TFT to prolonged gate bias. However, a major drawback of this measurement method is that it cannot distinguish whether the shift is caused by the change in the midgap states in the a-Si:H channel or by charge trapping in the gate insulator. In view of this, we have developed a capacitance-voltage (C-V) method to measure the shift in threshold voltage. We employ Metal-Insulator-Semiconductor (MIS) structures to investigate the threshold voltage shift as they are simpler to fabricate than TFTs. We have investigated a large of number Metal/a-Si:H/Si3N4/Si+n structures using our C-V technique. From, the C-V data for the MIS structures, we have found that the relationship between the thermal energy and threshold voltage shift is similar to that reported by Wehrspohn et. al in a-Si:H TFTs (J Appl. Phys, 144, 87, 2000). The a-Si:H and Si3N4 layers were grown using the radio-frequency plasma-enhanced chemical vapour deposition technique.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

CMOS nanocrystalline silicon thin film transistors with high field effect mobility are reported. The transistors were directly deposited by radio-frequency plasma enhanced chemical vapor deposition at 150°C The transistors show maximum field effect mobility of 450 cm2/V-s for electrons and 100 cm2/V-s for holes at room temperature. We attribute the high mobilities to a reduction of the oxygen content, which acts as an accidental donor. Indeed, secondary ion mass spectrometry measurements show that the impurity concentration in the nanocrystalline Si layer is comparable to, or lower than, the defect density in the material, which is already low thanks to hydrogen passivation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Automated Identification and in particular, Radio Frequency Identification (RFID) promises to assist with the automation of mass customised production processes. RFID has long been used to gather a history or trace of part movements, but the use of it as an integral part of the control process is yet to be fully exploited. Such use places stringent demands on the quality of the sensor data and the method used to interpret that data. in particular, this paper focuses on the issue of correctly identifying, tracking and dealing with aggregated objects with the use of RFID. The presented approach is evaluated in the context of a laboratory manufacturing system that produces customised gift boxes. Copyright © 2005 IFAC.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A measurement system for magnetic fields or electric currents uses a single-core fluxgate, magneto-inductive or magneto-impedance device driven from a radio frequency excitation source. Flux nulling feedback circuitry is provided to maintain the core of the sensor at substantially zero net flux and improve the linearity and dynamic response of the sensor system. A high pass filter is provided for reducing the dc effects of the ohmic resistance of the coil and lead wires on the effectiveness of the flux nulling feedback.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A measurement system for magnetic fields and electric currents uses a single-core fluxgate device driven with a radio frequency excitation source and is provided with a means to indicate saturation of the core of the sensor. A means is provided for detecting overload of the sensor as the core approaches continuous saturation using a pair of demodulators and a comparator.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A wide area and error free ultra high frequency (UHF) radio frequency identification (RFID) interrogation system based on the use of multiple antennas used in cooperation to provide high quality ubiquitous coverage, is presented. The system uses an intelligent distributed antenna system (DAS) whereby two or more spatially separated transmit and receive antenna pairs are used to allow greatly improved multiple tag identification performance over wide areas. The system is shown to increase the read accuracy of 115 passive UHF RFID tags to 100% from <60% over a 10m × 8m open plan office area. The returned signal strength of the tag backscatter signals is also increased by an average of 10dB and 17dB over an area of 10m 8m and 10m × 4m respectively. Furthermore, it is shown that the DAS RFID system has improved immunity to tag orientation. Finally, the new system is also shown to increase the tag read speed/rate of a population of tags compared with a conventional RFID system. © 2012 IEEE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tracking of project related entities such as construction equipment, materials, and personnel is used to calculate productivity, detect travel path conflicts, enhance the safety on the site, and monitor the project. Radio frequency tracking technologies (Wi-Fi, RFID, UWB) and GPS are commonly used for this purpose. However, on large-scale sites, deploying, maintaining and removing such systems can be costly and time-consuming. In addition, privacy issues with personnel tracking often limits the usability of these technologies on construction sites. This paper presents a vision based tracking framework that holds promise to address these limitations. The framework uses videos from a set of two or more static cameras placed on construction sites. In each camera view, the framework identifies and tracks construction entities providing 2D image coordinates across frames. Combining the 2D coordinates based on the installed camera system (the distance between the cameras and the view angles of them), 3D coordinates are calculated at each frame. The results of each step are presented to illustrate the feasibility of the framework.