879 resultados para Pulsed dielectric barrier discharge


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and objective: We aimed to identify the frequency of, reasons for and risk factors associated with additional healthcare visits and rehospitalizations (healthcare interactions) by patients with community-acquired pneumonia (CAP) within 30 days of hospital discharge. Methods: Observational analysis of a prospective cohort of adults hospitalized with CAP at a tertiary hospital (2007-2009). Additional healthcare interactions were defined as the visits to a primary care centre or emergency department and hospital readmissions within 30 days of discharge. Results: Of the 934 hospitalized patients with CAP, 282 (34.1%) had additional healthcare interactions within 30 days of hospital discharge: 149 (52.8%) needed an additional visit to their primary care centre and 177 (62.8%) attended the emergency department. Seventy-two (25.5%) patients were readmitted to hospital. The main reasons for additional healthcare interactions were worsening of signs or symptoms of CAP and new or worsening comorbid conditions independent of pneumonia, mainly cardiovascular and pulmonary diseases. The only independent factor associated with visits to primary care centre or emergency department was alcohol abuse (odds ratio [OR] = 1.65; 95% confidence interval [CI]: 1.03-2.64). Prior hospitalization (≤ 90 days) (OR = 2.47; 95% CI: 1.11-5.52) and comorbidities (OR = 3.99; 95% CI: 1.12-14.23) were independently associated with rehospitalization. Conclusions: Additional healthcare visits and rehospitalizations within 30 days of hospital discharge are common in patients with CAP. This is mainly due to a worsening of signs or symptoms of CAP and/or comorbid conditions. These findings may have implications for discharge planning and follow-up of patients with CAP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nursing discharge planning for elderly medical inpatients is an essential element of care to ensure optimal transition to home and to reduce post-discharge adverse events. The objectives of this cross-sectional study were to investigate the association between nursing discharge planning components in older medical inpatients, patients' readiness for hospital discharge and unplanned health care utilization during the following 30 days. Results indicated that no patients benefited from comprehensive discharge planning but most benefited from less than half of the discharge planning components. The most frequent intervention recorded was coordination, and the least common was patients' participation in decisions regarding discharge. Patients who received more nursing discharge components felt significantly less ready to go home and had significantly more readmissions during the 30-day follow-up period. This study highlights large gaps in the nursing discharge planning process in older medical inpatients and identifies specific areas where improvements are most needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is an increasing need to develop improved systems for predicting the safety of xenobiotics. However, to move beyond hazard identification the available concentration of the test compounds needs to be incorporated. In this study cyclosporine A (CsA) was used as a model compound to assess the kinetic profiles in two rodent brain cell cultures after single and repeated exposures. CsA induced-cyclophilin B (Cyp-B) secretion was also determined as CsA-specific pharmacodynamic endpoint. Since CsA is a potent p-glycoprotein substrate, the ability of this compound to cross the blood-brain barrier (BBB) was also investigated using an in vitro bovine model with repeated exposures up to 14days. Finally, CsA uptake mechanisms were studied using a parallel artificial membrane assay (PAMPA) in combination with a Caco-2 model. Kinetic results indicate a low intracellular CsA uptake, with no marked bioaccumulation or biotransformation. In addition, only low CsA amounts crossed the BBB. PAMPA and Caco-2 experiments revealed that CsA is mostly trapped to lipophilic compartments and exits the cell apically via active transport. Thus, although CsA is unlikely to enter the brain at cytotoxic concentrations, it may cause alterations in electrical activity and is likely to increase the CNS concentration of other compounds by occupying the BBBs extrusion capacity. Such an integrated testing system, incorporating BBB, brain culture models and kinetics could be applied for assessing neurotoxicity potential of compounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acute lung injury (ALI) is a clinical manifestation of respiratory failure, caused by lung inflammation and the disruption of the alveolar-capillary barrier. Preservation of the physical integrity of the alveolar epithelial monolayer is of critical importance to prevent alveolar edema. Barrier integrity depends largely on the balance between physical forces on cell-cell and cell-matrix contacts, and this balance might be affected by alterations in the coagulation cascade in patients with ALI. We aimed to study the effects of activated protein C (APC) on mechanical tension and barrier integrity in human alveolar epithelial cells (A549) exposed to thrombin. Cells were pretreated for 3 h with APC (50 mg/ml) or vehicle (control). Subsequently, thrombin (50 nM) or medium was added to the cell culture. APC significantly reduced thrombin-induced cell monolayer permeability, cell stiffening, and cell contraction, measured by electrical impedance, optical magnetic twisting cytometry, and traction microscopy, respectively, suggesting a barrier-protective response. The dynamics of the barrier integrity was also assessed by western blotting and immunofluorescence analysis of the tight junction ZO-1. Thrombin resulted in more elongated ZO-1 aggregates at cell-cell interface areas and induced an increase in ZO-1 membrane protein content. APC attenuated the length of these ZO-1 aggregates and reduced the ZO-1 membrane protein levels induced by thrombin. In conclusion, pretreatment with APC reduced the disruption of barrier integrity induced by thrombin, thus contributing to alveolar epithelial barrier protection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Early readmission is the major success indicator of the transition between hospital and home. Patients admitted with heart failure reach a 20% rate. Potentially avoidable readmissions, defined as unpredictable and related to a known condition during index hospitalization, represent the improvement margin. For these latter, implementation of specific interventions can be effective. Complex interventions on transition, including several modalities and seeking to encourage patient autonomy seem more effective than others. We describe two models: a pragmatic one developed in a regional hospital, and a more complex one developed in a university hospital during the LEAR-HF study. In both cases, it is imperative to work on "medical liability": should it extend beyond discharge up to the threshold of the private practice?

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intestinal infection with Salmonella enterica serotype Enteritidis, a food-borne infection spread to humans especially through contaminated eggs and egg-products as well as undercooked contaminated fresh meat, is the most common cause of intestinal inflammation in the European Union. Enteritis caused by Salmonella Enteritidis is characterized by fever, diarrhoea and abdominal pain. The disruption of the intestinal epithelial barrier function contributes to diarrhoea and is responsible for the perpetuation of the inflammatory process. In this sense, oxidative stress and the proinflammatory cytokines TNF-α, IFN-γ and IL-1β are described to induce the disorganization of the tight junctions (TJ), the most apical epithelial intercellular junctions and responsible for the paracellular permeability. The interest of this chapter relies not only in the investigation dealing with the mechanisms of TJ regulation but also in the contribution to the development of new tools for the prevention of epithelial barrier disruption in enteritis caused by Salmonella Enteritidis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical theory to describe the combined effects of the epitaxial layer thickness and the ohmic contact on the noise properties of Schottky barrier diodes is presented. The theory, which provides information on both the local and the global noise properties, takes into account the finite size of the epitaxial layer and the effects of the back ohmic contact, and applies to the whole range of applied bias. It is shown that by scaling down the epitaxial layer thickness, the current regime in which the noise temperature displays a shot-noise-like behavior increases at the cost of reducing the current range in which the thermal-noise-like behavior dominates. This improvement in noise temperature is limited by the effects of the ohmic contact, which appear for large currents. The theory is formulated on general trends, allowing its application to the noise analysis of other semiconductor devices operating under strongly inhomogeneous distributions of the electric field and charge concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical theory to describe the combined effects of the epitaxial layer thickness and the ohmic contact on the noise properties of Schottky barrier diodes is presented. The theory, which provides information on both the local and the global noise properties, takes into account the finite size of the epitaxial layer and the effects of the back ohmic contact, and applies to the whole range of applied bias. It is shown that by scaling down the epitaxial layer thickness, the current regime in which the noise temperature displays a shot-noise-like behavior increases at the cost of reducing the current range in which the thermal-noise-like behavior dominates. This improvement in noise temperature is limited by the effects of the ohmic contact, which appear for large currents. The theory is formulated on general trends, allowing its application to the noise analysis of other semiconductor devices operating under strongly inhomogeneous distributions of the electric field and charge concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spherical carbon coated iron particles of nanometric diameter in the 5-10 nm range have been produced by arc discharge at near-atmospheric pressure conditions (using 5-8·10 4 Pa of He). The particles exhibit a crystalline dense iron core with an average diameter 7.4 ± 2.0 nm surrounded by a sealed carbon shell, shown by transmission electron microscopy (TEM), selected-area diffrac- tion (SAED), energy-dispersive X-ray analysis (STEM-EDX) and electron energy loss spectroscopy (EELS). The SAED, EDX and EELS results indicate a lack of traces of core oxidized phases showing an efficient protection role of the carbon shell. The magnetic properties of the nanoparticles have been investigated in the 5-300 K temperature range using a superconducting quantum interference device (SQUID). The results reveal a superparamagnetic behaviour with an average monodomain diameter of 7.6 nm of the nanoparticles. The zero field cooled and field cooled (ZFC-FC)magnetization curves show a blocking temperature (TB)at room temperature very suitable for biomedical applications (drug delivery, magnetic resonance imaging-MRI-, hyperthermia).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The need for automated analyzers for industrial and environmental samples has triggered the research for new and cost-effective strategies of automation and control of analytical systems. The widespread availability of open-source hardware together with novel analytical methods based on pulsed flows have opened the possibility of implementing standalone automated analytical systems at low cost. Among the areas that can benefit from this approach are the analysis of industrial products and effluents and environmental analysis. In this work, a multi-pumping flow system is proposed for the determination of phosphorus in effluents and polluted water samples. The system employs photometric detection based on the formation of molybdovanadophosphoric acid, and the fluidic circuit is built using three solenoid micropumps. The detection is implemented with a low cost LED-photodiode photometric detection system and the whole system is controlled by an open-source Arduino Uno microcontroller board. The optimization of the timing to ensure the color development and the pumping cycle is discussed for the proposed implementation. Experimental results to evaluate the system behavior are presented verifying a linear relationship between the relative absorbance and the phosphorus concentrations for levels as high as 50 mg L-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Kandidaatintyössä on luotu katsaus maakaapelirakenteisiin ja erilaisiin maakaapelien kuntomittausmenetelmiin, kuten osittaispurkausmittaus ja dielektrisen vasteen mittaaminen. Työssä on myös esitelty muutamat yleisimmät mittauslaitteistot ja sivuttu lyhyesti mittausten hyödyntämistä kunnossapidossa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interest in recovery of valuable components from process streams has increased in recent years. Purpose of biorefinery is to utilize components that otherwise would go to waste. Hemicelluloses, for example, could be utilized in production of many valuable products. One possible way to separate and fractionate hemicelluloses is membrane filtration. In the literature part of this work membrane fouling in filtration processes of pulp and paper process- and wastewaters was investigated. Especially purpose was to find out the possible fouling compounds, after which facilities to remove or modify such components less harmful were studied. In the experimental part different pretreatment methods, mainly to remove or degrade lignin from wood hydrolysate, were studied. In addition, concentration of hemicelluloses and separation from lignin were examined with two ultrafiltration membranes; UFX5 and RC70PP. Changes in feed solution, filtration capacity and fouling of membranes were used to evaluate the effects of pretreatment methods. Changes in hydrolysate composition were observed with different analysis methods. Filtration of hydrolysate proved to be challenging, especially with the UFX5 membrane. The more hydrophilic RC70PP membrane did not seem to be fouled as severely as the UFX5 membrane, according to pure water flux measurements. The UFX5 membrane retained hemicelluloses rather well, but problems arose from rapid flux decline resulting from concentration polarization and fouling of membrane. Most effective pretreatment methods in the case with the UFX5 membrane proved to be prefiltration with the RC70PP membrane, activated carbon adsorption and photocatalytic oxidation using titanium dioxide and UV radiation. An additional experiment with PHW extract showed that pulsed corona discharge treatment degraded lignin quite efficiently and thus improved filtration capacity remarkably, even over six times compared to the filtration with untreated extract.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to font problem on the tilte field the titlte of the thesis is corrected here. The title of the thesis is: Superconducting properties and their enhancement in ReBa2Cu3O7-delta (RE = Y and Gd) films prepared by pulsed laser deposition