916 resultados para Power Systems, Load Model, Indentification
Resumo:
Cue exposure treatment (CET) consists of controlled and repeated exposure to drugrelated stimuli in order to reduce cue-reactivity. Virtual reality (VR) has proved to be a promising tool for exposition. However, identifying the variables that can modulate the efficacy of this technique is essential for selecting the most appropriate exposure modality. The aim of this study was to determine the relation between several individual variables and self-reported craving in smokers exposed to VR environments. Fortysix smokers were exposed to seven complex virtual environments that reproduce typical situations in which people smoke. Self-reported craving was selected as the criterion variable and three types of variables were selected as the predictor variables: related to nicotine dependence, related to anxiety and impulsivity, and related to the sense of presence in the virtual environments. Sense of presence was the only predictor of self-reported craving in all the experimental virtual environments. Nicotine dependence variables added predictive power to the model only in the virtual breakfast at home. No relation was found between anxiety or impulsivity and self-reported craving. Virtual reality technology can be very helpful for improving CET for substance use disorders. However, the use of virtual environments would make sense only insofar as the sense of presence was high. Otherwise, the effectiveness of exposure might be affected. © 2012 by the Massachusetts Institute of Technology.
Resumo:
This study aimed to produce and characterize a novel material from fish scales and chitosan for use as a medium for the extended release of herbicides. The mechanism of release for the herbicides atrazine and diuron was influenced by diffusion and swelling according to the power law kinetic model. The atrazine release time was seven days, while that of diuron was four days. The results of this study will contribute to the development of environmental matrices for herbicide release systems.
Resumo:
Huoli ympäristön tilasta ja fossiilisten polttoaineiden hinnan nousu ovat vauhdittaneet tutkimusta uusien energialähteiden löytämiseksi. Polttokennot ovat yksi lupaavimmista tekniikoista etenkin hajautetun energiantuotannon, varavoimalaitosten sekä liikennevälineiden alueella. Polttokenno on tehonlähteenä kuitenkin hyvin epäideaalinen, ja se asettaa tehoelektroniikalle lukuisia erityisvaatimuksia. Polttokennon kytkeminen sähköverkkoon on tavallisesti toteutettu käyttämällä galvaanisesti erottavaa DC/DC hakkuria sekä vaihtosuuntaajaa sarjassa. Polttokennon kulumisen estämiseksi tehoelektroniikalta vaaditaan tarkkaa polttokennon lähtövirran hallintaa. Perinteisesti virran hallinta on toteutettu säätämällä hakkurin tulovirtaa PI (Proportional and Integral) tai PID (Proportional, Integral and Derivative) -säätimellä. Hakkurin epälineaarisuudesta johtuen tällainen ratkaisu ei välttämättä toimi kaukana linearisointipisteestä. Lisäksi perinteiset säätimet ovat herkkiä mallinnusvirheille. Tässä diplomityössä on esitetty polttokennon jännitettä nostavan hakkurin tilayhtälökeskiarvoistusmenetelmään perustuva malli, sekä malliin perustuva diskreettiaikainen integroiva liukuvan moodin säätö. Esitetty säätö on luonteeltaan epälineaarinen ja se soveltuu epälineaaristen ja heikosti tunnettujen järjestelmien säätämiseen.
Resumo:
Tämän diplomityön tavoitteena oli tutkia tasehallinnan kehittämismahdollisuuksia Suomessa järjestelmävastaavan näkökulmasta. Sähköjärjestelmässä tulee vallita jatkuvasti tasapaino tuotannon ja kulutuksen välillä, tämän järjestelmävastaavan vastuulla olevan tasapainon ylläpitoa kutsutaan tehotasapainon hallinnaksi. Työssä pääasiasiallinen huomio oli markkinalähtöisessä tehotasapainon hallinnan kehittämisessä. Tuotantosuunnitelmat ovat ratkaisevassa osassa sähköjärjestelmän muutoksia ennustettaessa ja suunniteltaessa. Pääasiassa tutkimus kohdistuu tuotantosuunnitelmien tarkentamisen mahdollisuuksien analysointiin sekä tarkentamisesta aiheutuvien muutosten selvittämiseen. Työn yhteydessä toteutettiin sopivalla otannalla kyselytutkimus, jonka oli tarkoitus antaa tietoa Eurooppalaisista käytännöistä asian suhteen. Tutkimusten pohjalta päädyttiin malliin, jossa tuotantosuunnitelmien jaksonpituutta lyhennettäisiin nykyisestä 60 minuutista 15 minuuttiin. 15 minuutin jaksonpituus ulottuisi koko tuotantotaseen käsittelyyn, mukaan lukien säätösähkömarkkinat ja muut tehokaupat.
Resumo:
The objective of this master’s thesis is to investigate the loss behavior of three-level ANPC inverter and compare it with conventional NPC inverter. The both inverters are controlled with mature space vector modulation strategy. In order to provide the comparison both accurate and detailed enough NPC and ANPC simulation models should be obtained. The similar control model of SVM is utilized for both NPC and ANPC inverter models. The principles of control algorithms, the structure and description of models are clarified. The power loss calculation model is based on practical calculation approaches with certain assumptions. The comparison between NPC and ANPC topologies is presented based on results obtained for each semiconductor device, their switching and conduction losses and efficiency of the inverters. Alternative switching states of ANPC topology allow distributing losses among the switches more evenly, than in NPC inverter. Obviously, the losses of a switching device depend on its position in the topology. Losses distribution among the components in ANPC topology allows reducing the stress on certain switches, thus losses are equally distributed among the semiconductors, however the efficiency of the inverters is the same. As a new contribution to earlier studies, the obtained models of SVM control, NPC and ANPC inverters have been built. Thus, this thesis can be used in further more complicated modelling of full-power converters for modern multi-megawatt wind energy conversion systems.
Resumo:
All over the world power systems become bigger and bigger every day. New equipment is installed, new feeders are constructed, new power units are installed. Some old elements of the network, however, are not changed in time. As a result, “bottlenecks” for capacity transmission can occur. By locked power problem the situation when a power plant has installed capacity exceeding the power it can actually deliver is usually meant. Regime, scheme or even technical restrictions-related issues usually cause this kind of problem. It is really important, since from the regime point of view it is typical decision to have a mobile capacity reserve, in case of malfunctions. And, what can be even more significant, power plant owner (JSC Fortum in our case) losses his money because of selling less electrical energy. The goal of master`s thesis is to analyze the current state of Chelyabinsk power system and the CHP-3 (Combined Heat and Power plant) in particular in relation with it`s ability to deliver the whole capacity of the CHP in it`s existing state and also taking into consideration the prospect of power unit 3 installation by the fourth quarter of 2010. The thesis contains some general information about the UPS of Russia, CPS of Ural, power system of Chelyabinsk and the Chelyabinsk region itself. Then the CHP-3 is described from technical point of view with it`s equipment observation. Regimes for the nowadays power system and for the system after the power unit 3 installation are reviewed. The problems occurring are described and, finally, a solution is offered.
Resumo:
Aurinkosähköjärjestelmien käyttäminen sähkön tuotannossa on kasvanut viime vuosina teknologian hinnan laskun ja tiukentuvien ympäristömääräyksien seurauksena. Monet aurinkosähköön keskittyvät yritykset etsivät uusia markkinoita Afrikan kehittyvistä maista. Aurinkosähkön avulla voidaan vastata kehittyvien maiden kasvavaan sähköntarpeeseen ja samalla vähentää maiden hiilidioksidipäästöjä sekä nostaa maiden kehittyvää elintasoa. Tässä työssä tutkitaan aurinkosähköjärjestelmien viemistä kahteen Afrikan kehittyvään maahan Tansaniaan ja Etelä-Afrikkaan. Työn tavoitteena on kohdemaiden liiketoimintaympäristöjen tutkiminen ja markkinapotentiaalin selvittäminen suomalaisen sähkö- ja automaatiotekniikkaan keskittyvän pk-yrityksen näkökulmasta. Työssä selvitetään Tansanian ja Etelä-Afrikan liiketoimintaympäristöjen ja aurinkosähkömarkkinoiden erityispiirteet. Tuloksissa käsitellään myös sopivinta kansainvälistymistapaa tutkitulle pk-yritykselle sekä haasteita, joita yritys kohtaa Afrikan markkinoilla. Kansainvälistymismalleista tutkimuksessa käsitellään Uppsala-mallia ja verkostomallia.
Resumo:
A system is said to be "instantaneous" when for a given constant input an equilibrium output is obtained after a while. In the meantime, the output is changing from its initial value towards the equilibrium one. This is the transient period of the system and transients are important features of open-respirometry systems. During transients, one cannot compute the input amplitude directly from the output. The existing models (e.g., first or second order dynamics) cannot account for many of the features observed in real open-respirometry systems, such as time lag. Also, these models do not explain what should be expected when a system is speeded up or slowed down. The purpose of the present study was to develop a mechanistic approach to the dynamics of open-respirometry systems, employing basic thermodynamic concepts. It is demonstrated that all the main relevant features of the output dynamics are due to and can be adequately explained by a distribution of apparent velocities within the set of molecules travelling along the system. The importance of the rate at which the molecules leave the sensor is explored for the first time. The study approaches the difference in calibrating a system with a continuous input and with a "unit impulse": the former truly reveals the dynamics of the system while the latter represents the first derivative (in time) of the former and, thus, cannot adequately be employed in the apparent time-constant determination. Also, we demonstrate why the apparent order of the output changes with volume or flow.
Resumo:
Demand for the use of energy systems, entailing high efficiency as well as availability to harness renewable energy sources, is a key issue in order to tackling the threat of global warming and saving natural resources. Organic Rankine cycle (ORC) technology has been identified as one of the most promising technologies in recovering low-grade heat sources and in harnessing renewable energy sources that cannot be efficiently utilized by means of more conventional power systems. The ORC is based on the working principle of Rankine process, but an organic working fluid is adopted in the cycle instead of steam. This thesis presents numerical and experimental results of the study on the design of small-scale ORCs. Two main applications were selected for the thesis: waste heat re- covery from small-scale diesel engines concentrating on the utilization of the exhaust gas heat and waste heat recovery in large industrial-scale engine power plants considering the utilization of both the high and low temperature heat sources. The main objective of this work was to identify suitable working fluid candidates and to study the process and turbine design methods that can be applied when power plants based on the use of non-conventional working fluids are considered. The computational work included the use of thermodynamic analysis methods and turbine design methods that were based on the use of highly accurate fluid properties. In addition, the design and loss mechanisms in supersonic ORC turbines were studied by means of computational fluid dynamics. The results indicated that the design of ORC is highly influenced by the selection of the working fluid and cycle operational conditions. The results for the turbine designs in- dicated that the working fluid selection should not be based only on the thermodynamic analysis, but requires also considerations on the turbine design. The turbines tend to be fast rotating, entailing small blade heights at the turbine rotor inlet and highly supersonic flow in the turbine flow passages, especially when power systems with low power outputs are designed. The results indicated that the ORC is a potential solution in utilizing waste heat streams both at high and low temperatures and both in micro and larger scale appli- cations.
Resumo:
If electricity users adjusted their consumption patterns according to time-variable electricity prices or other signals about the state of the power system, generation and network assets could be used more efficiently, and matching intermittent renewable power generation with electricity demand would be facilitated. This kind of adjustment of electricity consumption, or demand response, may be based on consumers’ decisions to shift or reduce electricity use in response to time-variable electricity prices or on the remote control of consumers’ electric appliances. However, while demand response is suggested as a solution to many issues in power systems, actual experiences from demand response programs with residential customers are mainly limited to short pilots with a small number of voluntary participants, and information about what kinds of changes consumers are willing and able to make and what motivates these changes is scarce. This doctoral dissertation contributes to the knowledge about what kinds of factors impact on residential consumers’ willingness and ability to take part in demand response. Saving opportunities calculated with actual price data from the Finnish retail electricity market are compared with the occurred supplier switching to generate a first estimate about how large savings could trigger action also in the case of demand response. Residential consumers’ motives to participate in demand response are also studied by a web-based survey with 2103 responses. Further, experiences of households with electricity consumption monitoring systems are discussed to increase knowledge about consumers’ interest in getting more information on their electricity use and adjusting their behavior based on it. Impacts of information on willingness to participate in demand response programs are also approached by a survey for experts of their willingness to engage in demand response activities. Residential customers seem ready to allow remote control of electric appliances that does not require changes in their everyday routines. Based on residents’ own activity, the electricity consuming activities that are considered shiftable are very limited. In both cases, the savings in electricity costs required to allow remote control or to engage in demand response activities are relatively high. Nonmonetary incentives appeal to fewer households.
Resumo:
This thesis reviews the role of nuclear and conventional power plants in the future energy system. The review is done by utilizing freely accesible publications in addition to generating load duration and ramping curves for Nordic energy system. As the aim of the future energy system is to reduce GHG-emissions and avoid further global warming, the need for flexible power generation increases with the increased share of intermittent renewables. The goal of this thesis is to offer extensive understanding of possibilities and restrictions that nuclear power and conventional power plants have regarding flexible and sustainable generation. As a conclusion, nuclear power is the only technology that is able to provide large scale GHG-free power output variations with good ramping values. Most of the currently operating plants are able to take part in load following as the requirement to do so is already required to be included in the plant design. Load duration and ramping curves produced prove that nuclear power is able to cover most of the annual generation variation and ramping needs in the Nordic energy system. From the conventional power generation methods, only biomass combustion can be considered GHG-free because biomass is considered carbon neutral. CFB combusted biomass has good load follow capabilities in good ramping and turndown ratios. All the other conventional power generation technologies generate GHG-emissions and therefore the use of these technologies should be reduced.
Resumo:
Increasingly growing share of distributed generation in the whole electrical power system’s generating system is currently a worldwide tendency, driven by several factors, encircling mainly difficulties in refinement of megalopolises’ distribution networks and its maintenance; widening environmental concerns adding to both energy efficiency approaches and installation of renewable sources based generation, inherently distributed; increased power quality and reliability needs; progress in IT field, making implementable harmonization of needs and interests of different-energy-type generators and consumers. At this stage, the volume, formed by system-interconnected distributed generation facilities, have reached the level of causing broad impact toward system operation under emergency and post-emergency conditions in several EU countries, thus previously implementable approach of their preliminary tripping in case of a fault, preventing generating equipment damage and disoperation of relay protection and automation, is not applicable any more. Adding to the preceding, withstand capability and transient electromechanical stability of generating technologies, interconnecting in proximity of load nodes, enhanced significantly since the moment Low Voltage Ride-Through regulations, followed by techniques, were introduced in Grid Codes. Both aspects leads to relay protection and auto-reclosing operation in presence of distributed generation generally connected after grid planning and construction phases. This paper proposes solutions to the emerging need to ensure correct operation of the equipment in question with least possible grid refinements, distinctively for every type of distributed generation technology achieved its technical maturity to date and network’s protection. New generating technologies are equivalented from the perspective of representation in calculation of initial steady-state short-circuit current used to dimension current-sensing relay protection, and widely adopted short-circuit calculation practices, as IEC 60909 and VDE 0102. The phenomenon of unintentional islanding, influencing auto-reclosing, is addressed, and protection schemes used to eliminate an sustained island are listed and characterized by reliability and implementation related factors, whereas also forming a crucial aspect of realization of the proposed protection operation relieving measures.
Resumo:
The issue of selecting an appropriate healthcare information system is a very essential one. If implemented healthcare information system doesn’t fit particular healthcare institution, for example there are unnecessary functions; healthcare institution wastes its resources and its efficiency decreases. The purpose of this research is to develop a healthcare information system selection model to assist the decision-making process of choosing healthcare information system. Appropriate healthcare information system helps healthcare institutions to become more effective and efficient and keep up with the times. The research is based on comparison analysis of 50 healthcare information systems and 6 interviews with experts from St-Petersburg healthcare institutions that already have experience in healthcare information system utilization. 13 characteristics of healthcare information systems: 5 key and 7 additional features are identified and considered in the selection model development. Variables are used in the selection model in order to narrow the decision algorithm and to avoid duplication of brunches. The questions in the healthcare information systems selection model are designed to be easy-to-understand for common a decision-maker in healthcare institution without permanent establishment.
Resumo:
La phagocytose est un processus cellulaire par lequel de larges particules sont internalisées dans une vésicule, le phagosome. Lorsque formé, le phagosome acquiert ses propriétés fonctionnelles à travers un processus complexe de maturation nommé la biogénèse du phagolysosome. Cette voie implique une série d’interactions rapides avec les organelles de l’appareil endocytaire permettant la transformation graduelle du phagosome nouvellement formé en phagolysosome à partir duquel la dégradation protéolytique s’effectue. Chez l’amibe Dictyostelium discoideum, la phagocytose est employée pour ingérer les bactéries de son environnement afin de se nourrir alors que les organismes multicellulaires utilisent la phagocytose dans un but immunitaire, où des cellules spécialisées nommées phagocytes internalisent, tuent et dégradent les pathogènes envahissant de l’organisme et constitue la base de l’immunité innée. Chez les vertébrés à mâchoire cependant, la transformation des mécanismes moléculaires du phagosome en une organelle perfectionnée pour l’apprêtement et la présentation de peptides antigéniques place cette organelle au centre de l’immunité innée et de l’immunité acquise. Malgré le rôle crucial auquel participe cette organelle dans la réponse immunitaire, il existe peu de détails sur la composition protéique et l’organisation fonctionnelles du phagosome. Afin d’approfondir notre compréhension des divers aspects qui relient l’immunité innée et l’immunité acquise, il devient essentiel d’élargir nos connaissances sur les fonctions moléculaire qui sont recrutées au phagosome. Le profilage par protéomique à haut débit de phagosomes isolés fut extrêmement utile dans la détermination de la composition moléculaire de cette organelle. Des études provenant de notre laboratoire ont révélé les premières listes protéiques identifiées à partir de phagosomes murins sans toutefois déterminer le ou les rôle(s) de ces protéines lors du processus de la phagocytose (Brunet et al, 2003; Garin et al, 2001). Au cours de la première étude de cette thèse (Stuart et al, 2007), nous avons entrepris la caractérisation fonctionnelle du protéome entier du phagosome de la drosophile en combinant diverses techniques d’analyses à haut débit (protéomique, réseaux d’intéractions protéique et ARN interférent). En utilisant cette stratégie, nous avons identifié 617 protéines phagosomales par spectrométrie de masse à partir desquelles nous avons accru cette liste en construisant des réseaux d’interactions protéine-protéine. La contribution de chaque protéine à l’internalisation de bactéries fut ensuite testée et validée par ARN interférent à haut débit et nous a amené à identifier un nouveau régulateur de la phagocytose, le complexe de l’exocyst. En appliquant ce modèle combinatoire de biologie systémique, nous démontrons la puissance et l’efficacité de cette approche dans l’étude de processus cellulaire complexe tout en créant un cadre à partir duquel il est possible d’approfondir nos connaissances sur les différents mécanismes de la phagocytose. Lors du 2e article de cette thèse (Boulais et al, 2010), nous avons entrepris la caractérisation moléculaire des étapes évolutives ayant contribué au remodelage des propriétés fonctionnelles de la phagocytose au cours de l’évolution. Pour ce faire, nous avons isolé des phagosomes à partir de trois organismes distants (l’amibe Dictyostelium discoideum, la mouche à fruit Drosophila melanogaster et la souris Mus musculus) qui utilisent la phagocytose à des fins différentes. En appliquant une approche protéomique à grande échelle pour identifier et comparer le protéome et phosphoprotéome des phagosomes de ces trois espèces, nous avons identifié un cœur protéique commun à partir duquel les fonctions immunitaires du phagosome se seraient développées. Au cours de ce développement fonctionnel, nos données indiquent que le protéome du phagosome fut largement remodelé lors de deux périodes de duplication de gènes coïncidant avec l’émergence de l’immunité innée et acquise. De plus, notre étude a aussi caractérisée en détail l’acquisition de nouvelles protéines ainsi que le remodelage significatif du phosphoprotéome du phagosome au niveau des constituants du cœur protéique ancien de cette organelle. Nous présentons donc la première étude approfondie des changements qui ont engendré la transformation d’un compartiment phagotrophe à une organelle entièrement apte pour la présentation antigénique.
Resumo:
This paper presents a Reinforcement Learning (RL) approach to economic dispatch (ED) using Radial Basis Function neural network. We formulate the ED as an N stage decision making problem. We propose a novel architecture to store Qvalues and present a learning algorithm to learn the weights of the neural network. Even though many stochastic search techniques like simulated annealing, genetic algorithm and evolutionary programming have been applied to ED, they require searching for the optimal solution for each load demand. Also they find limitation in handling stochastic cost functions. In our approach once we learn the Q-values, we can find the dispatch for any load demand. We have recently proposed a RL approach to ED. In that approach, we could find only the optimum dispatch for a set of specified discrete values of power demand. The performance of the proposed algorithm is validated by taking IEEE 6 bus system, considering transmission losses