981 resultados para Portable.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reviews computational reliability, computer algebra, stochastic stability and rotating frame turbulence (RFT) in the context of predicting the blade inplane mode stability, a mode which is at best weakly damped. Computational reliability can be built into routine Floquet analysis involving trim analysis and eigenanalysis, and a highly portable special purpose processor restricted to rotorcraft dynamics analysis is found to be more economical than a multipurpose processor. While the RFT effects are dominant in turbulence modeling, the finding that turbulence stabilizes the inplane mode is based on the assumption that turbulence is white noise.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Even research models of helicopter dynamics often lead to a large number of equations of motion with periodic coefficients; and Floquet theory is a widely used mathematical tool for dynamic analysis. Presently, three approaches are used in generating the equations of motion. These are (1) general-purpose symbolic processors such as REDUCE and MACSYMA, (2) a special-purpose symbolic processor, DEHIM (Dynamic Equations for Helicopter Interpretive Models), and (3) completely numerical approaches. In this paper, comparative aspects of the first two purely algebraic approaches are studied by applying REDUCE and DEHIM to the same set of problems. These problems range from a linear model with one degree of freedom to a mildly non-linear multi-bladed rotor model with several degrees of freedom. Further, computational issues in applying Floquet theory are also studied, which refer to (1) the equilibrium solution for periodic forced response together with the transition matrix for perturbations about that response and (2) a small number of eigenvalues and eigenvectors of the unsymmetric transition matrix. The study showed the following: (1) compared to REDUCE, DEHIM is far more portable and economical, but it is also less user-friendly, particularly during learning phases; (2) the problems of finding the periodic response and eigenvalues are well conditioned.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bad breath or oral malodour can be related to gingival diseases, trimethylaminuria, various inflammation diseases of upper respiratory tract, foreign bodies in nasal cavity etc. Bad breath is usually, in 85 % to 95 % of cases, inflicted by gram negative anaerobic bacteria in tongue coating. These bacteria have a tendency of producing foul-smelling sulphur containing gases called volatile sulphur compounds or VSC. Main cause of bad breath is parodontitis or postnasal drip into posterior part of the tongue. Detecting bad breath is most efficiently done by organoleptic method. By skilled analyser the reason for oral malodour can be determined with great accuracy. For scientific study the most effective method is gas chromatography (GC) with flame photometric detector (FPD). With it almost every component of exhaled air can be detected both quantitative and qualitative. Effective chairside methods include portable sulphur monitors and saliva tests.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Beginning with the ‘frog-leg experiment’ by Galvani (1786), followed by the demonstrations of Volta pile by Volta (1792) and lead-acid accumulator by Plante´ (1859), several battery chemistries have been developed and realized commercially. The development of lithium-ion rechargeable battery in the early 1990s is a breakthrough in the science and technology of batteries. Owing to its high energy density and high operating voltage, the Li-ion battery has become the battery of choice for various portable applications such as note-book computers, cellular telephones, camcorders, etc. Huge efforts are underway in succeeding the development of large size batteries for electric vehicle applications. The origin of lithium-ion battery lies in the discovery that Li+-ions can reversibly be intercalated into/de-intercalated from the Van der Walls gap between graphene sheets of carbon materials at a potential close to the Li/Li+ electrode. By employing carbon as the negative electrode material in rechargeable lithium-ion batteries, the problems associated with metallic lithium in rechargeable lithium batteries have been mitigated. Complimentary investigations on intercalation compounds based on transition metals have resulted in establishing LiCoO2 as the promising cathode material. By employing carbon and LiCoO2, respectively, as the negative and positive electrodes in a non-aqueous lithium-salt electrolyte,a Li-ion cell with a voltage value of about 3.5 V has resulted.Subsequent to commercialization of Li-ion batteries, a number of research activities concerning various aspects of the battery components began in several laboratories across the globe. Regarding the positive electrode materials, research priorities have been to develop different kinds of active materials concerning various aspects such as safety, high capacity, low cost, high stability with long cycle-life, environmental compatibility,understanding relationships between crystallographic and electrochemical properties. The present review discusses the published literature on different positive electrode materials of Li-ion batteries, with a focus on the effect of particle size on electrochemical performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Direct borohydride fuel cells (DBFC) use aqueous alkaline sodium borohydride(NaBH4) as anode fuel to generate electric power with either oxygen or hydrogen peroxide as oxidant. The DBFCs are projected to be very handy for portable power appliances such as laptops and mobile phones in addition to their use in extreme conditions such as underwater and portable military applications. This short review discusses the progress in DBFC research based on electrode materials and membranes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Herein we report a novel fluoranthene-based fluorescent fluorophore 7,10-bis(4-bromophenyl)-8,9-bis4-(hexyloxy)phenyl]fluoranthene (S-3) and its remarkable properties in applications of explosive detection. The sensitivity towards the detection of nitroaromatics (NACs) was evaluated through fluorescence quenching in solution, vapor, and contact mode approaches. The contact mode approach using thin-layer silica chromatograp- hic plates exhibited a femtogram (1.15 fg cm(-2)) detection limit for trinitrotoluene (TNT) and picric acid (PA), whereas the solution-phase quenching showed PA detection at the 2-20 ppb level. Fluorescence lifetime measurements revealed that the quenching is static in nature and the quenching process is fully reversible. Binding energies between model binding sites of the S-3 and analyte compounds reveal that analyte molecules enter into the cavity created by substituted phenyl rings of fluoranthene and are stabilized by strong intermolecular interactions with alkyl chains. It is anticipated that the sensor S-3 could be a promising material for the construction of portable optical devices for the detection of onsite explosive nitroaromatics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cation sensing properties of the three positional isomers of rhodamine based sensors (1-3) are studied in water. The sensors differ only in the position of pyridine's nitrogen. The chemosensor 1, with pyridine nitrogen at ortho-position, showed a selective colorimetric detection of Cu(II) ions in water, at physiological pH 7.4 and also in medium containing BSA (bovine serum albumin) and blood serum. Notably the compound 2 and 3, with pyridine end located at meta-and para-positions did not show any color change with Cu(II) ions, although both the compounds showed turn-on change both in color and fluorescence with Hg(II) ions specifically. All the probes showed ratiometric changes with the specific metal ions. The changing position of nitrogen also changed the complexation pattern of the sensors with the metal ions. Probe 1 showed 2 : 1 complexation with Cu(II), whereas 2 and 3 showed 1 : 1 complexation with Hg(II) ions. The mechanism investigation showed that the change in color upon addition of metal ions is due to the ring-opening of the spirolactam ring of the probes. Cu(II) interacted with ligand 1 through a three-point interaction mode comprising carbonyl oxygen, amido nitrogen and pyridine nitrogen end. But in case of 2 and 3, Hg2+ only interacted through pyridine nitrogen ends. Quantitative estimation of Cu2+ and Hg2+ in complex biological media such as bovine albumin protein (BSA) and human blood serum were performed using these sensors. Rapid on-site detection as well as discrimination of these toxic ions was demonstrated using easily prepared portable test-strips.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Selective detection of nitro-aromatic compounds (NACs) at nanomolar concentration is achieved for the first time in multiple media including water, micelles or in organogels as well as using test strips. Mechanism of interaction of NACs with highly fluorescent p-phenylenevinylene-based molecules has been described as the electron transfer phenomenon from the electron-rich chromophoric probe to the electron deficient NACs. The selectivity in sensing is guided by the pK(a) of the probes as well as the NACs under consideration. TNP-induced selective gel-to-sol transition in THF medium is also observed through the reorganization of molecular self-assembly and the portable test trips are made successfully for rapid on-site detection purpose.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Deviated nasal septum (DNS) is one of the major causes of nasal obstruction. Polyvinylidene fluoride (PVDF) nasal sensor is the new technique developed to assess the nasal obstruction caused by DNS. This study evaluates the PVDF nasal sensor measurements in comparison with PEAK nasal inspiratory flow (PNIF) measurements and visual analog scale (VAS) of nasal obstruction. Methods: Because of piezoelectric property, two PVDF nasal sensors provide output voltage signals corresponding to the right and left nostril when they are subjected to nasal airflow. The peak-to-peak amplitude of the voltage signal corresponding to nasal airflow was analyzed to assess the nasal obstruction. PVDF nasal sensor and PNIF were performed on 30 healthy subjects and 30 DNS patients. Receiver operating characteristic was used to analyze the DNS of these two methods. Results: Measurements of PVDF nasal sensor strongly correlated with findings of PNIF (r = 0.67; p < 0.01) in DNS patients. A significant difference (p < 0.001) was observed between PVDF nasal sensor measurements and PNIF measurements of the DNS and the control group. A cutoff between normal and pathological of 0.51 Vp-p for PVDF nasal sensor and 120 L/min for PNIF was calculated. No significant difference in terms of sensitivity of PVDF nasal sensor and PNIF (89.7% versus 82.6%) and specificity (80.5% versus 78.8%) was calculated. Conclusion: The result shows that PVDF measurements closely agree with PNIF findings. Developed PVDF nasal sensor is an objective method that is simple, inexpensive, fast, and portable for determining DNS in clinical practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the design technique that has been adopted for packaging of Polyvinylidene fluoride (PVDF) nasal sensor for biomedical applications. The PVDF film with the dimension of length 10mm, width 5mm and thickness 28 mu m was firmly adhered on one end of plastic base (8mmx5mmx30 mu m) in such a way that it forms a cantilever configuration leaving the other end free for deflection. Now with the leads attached on the surface of the PVDF film, the cantilever configuration becomes the PVDF nasal sensor. For mounting a PVDF nasal sensor, a special headphone was designed, that can fit most of the human head sizes. Two flexible strings are soldered on either side of the headphone. Two identical PVDF nasal sensors were then connected to either side of flexible string of the headphone in such a way that they are placed below the right and left nostrils respectively without disturbing the normal breathing. When a subject wares headphone along with PVDF nasal sensors, two voltage signals due to the piezoelectric property of the PVDF film were generated corresponding to his/her nasal airflow from right and left nostril. The entire design was made compact, so that PVDF nasal sensors along with headphone can be made portable. No special equipment or machines are needed for mounting the PVDF nasal sensors. The time required for packaging of PVDF nasal sensors was less and the approximate cost of the entire assembly (PVDF nasal sensors + headphone) was very nominal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There are two major theories that attempt to explain hand preference in non-human primates-the `task complexity' theory and the `postural origins' theory. In the present study, we proposed a third hypothesis to explain the evolutionary origin of hand preference in non-human primates, stating that it could have evolved owing to structural and functional adaptations to feeding, which we refer to as the `niche structure' hypothesis. We attempted to explore this hypothesis by comparing hand preference across species that differ in the feeding ecology and niche structure: red howler monkeys, Alouatta seniculus and yellow-breasted capuchin monkeys, Sapajus xanthosternos. The red howler monkeys used the mouth to obtain food more frequently than the yellow-breasted capuchin monkeys. The red howler monkeys almost never reached for food presented on the opposite side of a wire mesh or inside a portable container, whereas the yellow-breasted capuchin monkeys reached for food presented in all four spatial arrangements (scattered, on the opposite side of a wire mesh, inside a suspended container, and inside a portable container). In contrast to the red howler monkeys that almost never acquired bipedal and clinging posture, the yellow-breasted capuchin monkeys acquired all five body postures (sitting, bipedal, tripedal, clinging, and hanging). Although there was no difference between the proportion of the red howler monkeys and the yellow-breasted capuchin monkeys that preferentially used one hand, the yellow-breasted capuchin monkeys exhibited an overall weaker hand preference than the red howler monkeys. Differences in hand preference diminished with the increasing complexity of the reaching-for-food tasks, i.e., the relatively more complex tasks were perceived as equally complex by both the red howler monkeys and the yellow-breasted capuchin monkeys. These findings suggest that species-specific differences in feeding ecology and niche structure can influence the perception of the complexity of the task and, consequently, hand preference.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

All solid state batteries are essential candidate for miniaturizing the portable electronics devices. Thin film batteries are constructed by layer by layer deposition of electrode materials by physical vapour deposition method. We propose a promising novel method and unique architecture, in which highly porous graphene sheet embedded with SnO2 nanowire could be employed as the anode electrode in lithium ion thin film battery. The vertically standing graphene flakes were synthesized by microwave plasma CVD and SnO2 nanowires based on a vapour-liquid-solid (VLS) mechanism via thermal evaporation at low synthesis temperature (620 degrees C). The graphene sheet/SnO2 nanowire composite electrode demonstrated stable cycling behaviours and delivered a initial high specific discharge capacity of 1335 mAh g(-1) and 900 mAh g(-1) after the 50th cycle. Furthermore, the SnO2 nanowire electrode displayed superior rate capabilities with various current densities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rechargeable batteries based on Li and Na ions have been growing leaps and bounds since their inception in the 1970s. They enjoy significant attention from both the fundamental science point of view and practical applications ranging from portable electronics to hybrid vehicles and grid storage. The steady demand for building better batteries calls for discovery, optimisation and implementation of novel positive insertion (cathode) materials. In this quest, chemists have tried to unravel many future cathode materials by taking into consideration their eco-friendly synthesis, material/process economy, high energy density, safety, easy handling and sustainability. Interestingly, sulfate-based cathodes offer a good combination of sustainable syntheses and high energy density owing to their high-voltage operation, stemming from electronegative SO42- units. This review delivers a sneak peak at the recent advances in the discovery and development of sulfate-containing cathode materials by focusing on their synthesis, crystal structure and electrochemical performance. Several family of cathodes are independently discussed. They are 1) fluorosulfates AMSO(4)F], 2) bihydrated fluorosulfates AMSO(4)F2H(2)O], 3) hydroxysulfate AMSO(4)OH], 4) bisulfates A(2)M(SO4)(2)], 5) hydrated bisulfates A(2)M(SO4)(2)nH(2)O], 6) oxysulfates Fe-2(SO4)(2)O] and 7) polysulfates A(2)M(2)(SO4)(3)]. A comparative study of these sulfate-based cathodes has been provided to offer an outlook on the future development of high-voltage polyanionic cathode materials for next-generation batteries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A robust, compact optical measurement unit for motion measurement in micro-cantilever arrays enables development of portable micro-cantilever sensors. This paper reports on an optical beam deflection-based system to measure the deflection of micro-cantilevers in an array that employs a single laser source, a single detector, and a resonating reflector to scan the measurement laser across the array. A strategy is also proposed to extract the deflection of individual cantilevers from the acquired data. The proposed system and measurement strategy are experimentally evaluated and demonstrated to measure motion of multiple cantilevers in an array. (C) 2015 AIP Publishing LLC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Peristaltic pumps were normally used to pump liquids in several chemical and biological applications. In the present study, a peristaltic pump was used to pressurize the chamber (positive as well negative pressures) using atmospheric air. In the present paper, we discuss the development and performance study of an automatic pressurization system to calibrate low range (millibar) pressure sensors. The system includes a peristaltic pump, calibrated pressure sensor (master sensor), pressure chamber, and the control electronics. An in-house developed peristaltic pump was used to pressurize the chamber. A closed loop control system has been developed to detect and adjust the pressure leaks in the chamber. The complete system has been integrated into a portable product. The system performance has been studied for a step response and steady state errors. The system is portable, free from oil contaminants, and consumes less power compared to existing pressure calibration systems. The veracity of the system was verified by calibrating an unknown diaphragm based pressure sensor and the results obtained were satisfactory. (C) 2015 AIP Publishing LLC.