963 resultados para Performance Reference Compounds
Resumo:
A large number of studies utilize animal models to investigate therapeutic angiogenesis. However, the lack of a standardized experimental model leaves the comparison of different studies problematic. To establish a reference model of prolonged moderate tissue ischemia, we created unilateral hind limb ischemia in athymic rnu-rats by surgical excision of the femoral vessels. Blood flow of the limb was monitored for 60 days by laser Doppler imaging. Following a short postoperative period of substantially depressed perfusion, the animals showed a status of moderate hind limb ischemia from day 14 onwards. Thereafter, the perfusion remained at a constant level (55.5% of normal value) until the end of the observation period. Histopathological assessment of the ischemic musculature on postoperative days 28 and 60 showed essentially no inflammatory cell infiltrate or fibrosis. However, the mitochondrial activity and capillary-to-fiber ratio of the muscular tissue was reduced to 52.7% of normal, presenting with a significant weakness of the ischemic limb evidenced by a progressive decline in performance. Intramuscular injection of culture-expanded human endothelial progenitor cells (EPC) resulted in a significant increase in blood flow (82.0+/-3.5% of normal), capillary density (1.60+/-0.08/muscle fiber) and smooth muscle covered arterioles (8.0+/-0.6/high power field) in the ischemic hind limb as compared to controls (55.0+/-3.1%; 0.99+/-0.03; 5.0+/-0.2). In conclusion, chronic, moderate hind limb ischemia with consistently reduced perfusion levels persisting over a prolonged period can be established reliably in rnu athymic nude rats and is responsive to pro-angiogenic treatments such as EPC transplantation. This study provides a detailed protocol of a highly reproducible reference model to test novel therapeutic options for limb ischemia.
Resumo:
Ventricular assist devices (VADs) are blood pumps that offer an option to support the circulation of patients with severe heart failure. Since a failing heart has a remaining pump function, its interaction with the VAD influences the hemodynamics. Ideally, the heart's action is taken into account for actuating the device such that the device is synchronized to the natural cardiac cycle. To realize this in practice, a reliable real-time algorithm for the automatic synchronization of the VAD to the heart rate is required. This paper defines the tasks such an algorithm needs to fulfill: the automatic detection of irregular heart beats and the feedback control of the phase shift between the systolic phases of the heart and the assist device. We demonstrate a possible solution to these problems and analyze its performance in two steps. First, the algorithm is tested using the MIT-BIH arrhythmia database. Second, the algorithm is implemented in a controller for a pulsatile and a continuous-flow VAD. These devices are connected to a hybrid mock circulation where three test scenarios are evaluated. The proposed algorithm ensures a reliable synchronization of the VAD to the heart cycle, while being insensitive to irregularities in the heart rate.
Resumo:
OBJECTIVE: We sought to evaluate the performance of the human papillomavirus high-risk DNA test in patients 30 years and older. MATERIALS AND METHODS: Screening (n=835) and diagnosis (n=518) groups were defined based on prior Papanicolaou smear results as part of a clinical trial for cervical cancer detection. We compared the Hybrid Capture II (HCII) test result with the worst histologic report. We used cervical intraepithelial neoplasia (CIN) 2/3 or worse as the reference of disease. We calculated sensitivities, specificities, positive and negative likelihood ratios (LR+ and LR-), receiver operating characteristic (ROC) curves, and areas under the ROC curves for the HCII test. We also considered alternative strategies, including Papanicolaou smear, a combination of Papanicolaou smear and the HCII test, a sequence of Papanicolaou smear followed by the HCII test, and a sequence of the HCII test followed by Papanicolaou smear. RESULTS: For the screening group, the sensitivity was 0.69 and the specificity was 0.93; the area under the ROC curve was 0.81. The LR+ and LR- were 10.24 and 0.34, respectively. For the diagnosis group, the sensitivity was 0.88 and the specificity was 0.78; the area under the ROC curve was 0.83. The LR+ and LR- were 4.06 and 0.14, respectively. Sequential testing showed little or no improvement over the combination testing. CONCLUSIONS: The HCII test in the screening group had a greater LR+ for the detection of CIN 2/3 or worse. HCII testing may be an additional screening tool for cervical cancer in women 30 years and older.
Resumo:
Oxygenated polycyclic aromatic hydrocarbons (oxy-PAHs) and nitrogen heterocyclic polycyclic aromatic compounds (N-PACs) are toxic, highly leachable and often abundant at sites that are also contaminated with PAHs. However, due to lack of regulations and standardized methods for their analysis, they are seldom included in monitoring and risk-assessment programs. This intercomparison study constitutes an important step in the harmonization of the analytical methods currently used, and may also be considered a first step towards the certification of reference materials for these compounds. The results showed that the participants were able to determine oxy-PAHs with accuracy similar to PAHs, with average determined mass fractions agreeing well with the known levels in a spiked soil and acceptable inter- and intra-laboratory precisions for all soils analyzed. For the N-PACs, the results were less satisfactory, and have to be improved by using analytical methods more specifically optimized for these compounds.
Resumo:
BACKGROUND Drug eluting stents for the treatment of small vessel coronary artery disease have traditionally yielded inferior clinical outcomes compared to the use of DES in large vessels. The benefit of the second-generation Resolute zotarolimus-eluting stent (R-ZES) in small vessels was examined. METHODS Two-year clinical outcomes from five combined R-ZES studies were compared between patients with small (reference vessel diameter [RVD] ≤2.5 mm; n = 1,956) and large (RVD >2.5 mm; n = 3174) vessels. RESULTS Despite a higher incidence of comorbidities in the small vessel group, there was no significant difference in target lesion failure (TLF) (10.1% vs. 8.7%; P = 0.54) at 2 years. When the subgroup of patients with diabetes was examined (n = 1,553) there was no significant difference in 2-year TLF in small compared to large vessels (11.2% vs. 11.1%; P = 0.17). Similarly, within the small vessel cohort, no significant difference was seen regarding TLF at 2 years between people with and without diabetes (11.2% vs 9.6%; P = 0.28). CONCLUSION When used for the treatment of small vessels, the R-ZES appears to provide acceptable clinical results at 2 years when compared to its performance in large vessels.
Resumo:
Humans often evaluate their abilities by comparing their personal performance with that of others. For this process, it is critical whether the comparison turns out in one's favor or against it. Here, we investigate how social comparisons of performance are encoded and integrated on the neural level. We collected functional magnetic resonance images while subjects answered questions in a knowledge quiz that was related to their profession. After each question, subjects received a feedback about their personal performance, followed by a feedback about the performance of a reference group who had been quizzed beforehand. Based on the subjects' personal performance, we divided trials in downward and upward comparisons. We found that upward comparisons correlated with activity in the dorsolateral prefrontal cortex and the anterior insula. Downward comparisons were associated with increased activation in the ventral striatum (VS), the medial orbitofrontal cortex and the ventral anterior cingulate cortex (ACC). The extent to which subjects outperformed the reference group modulated the activity in the VS and in the dorsal ACC. We suggest that the co-activation of the VS and the dorsal ACC contributes to the integration of downward comparisons into the evaluation of personal performance.
Resumo:
AIM To evaluate the performance of a pen‑type laser fluorescence device (DIAGNOdent 2190; LFpen, KaVo, Germany) and bitewing radiographs (BW) for approximal caries detection in permanent and primary teeth. MATERIALS AND METHODS A total of 246 anterior approximal surfaces (102 permanent and 144 primary) were selected. Contact points were simulated using sound teeth. Two examiners assessed all approximal surfaces using LFpen and BW. The teeth were histologically assessed for the reference standard. Optimal cut‑off limits were calculated for LFpen for primary and permanent teeth. Sensitivity, specificity, accuracy and area under the receiver operating characteristic curve (Az) were calculated for D1 (enamel and dentin lesions) and D3 (dentin lesions) thresholds. The reproducibility was assessed by intraclass correlation coefficient (ICC) and Cohen's weighted kappa values. RESULTS For permanent teeth, the LFpen cut‑off were 0- 27 (sound), 28- 33 (enamel caries) and >33 (dentin caries). For primary teeth, the LFpen cut‑off were 0- 7 (sound), 8- 32 (enamelcaries) and >32 (dentin caries). The LFpen presented higher sensitivity values than BW for primary teeth (0.58 vs. 0.32 at D1 and 0.80 vs. 0.47 at D3) and permanent teeth (0.80 vs. 0.57 at D1 and 0.94 vs. 0.51 at D3). Specificity did not show a significant difference between the methods. Rank correlations with histology were 0.59 and 0.83 (LFpen) and 0.36 and 0.70 (BW) for primary and permanent teeth, respectively, considering all lesions. ICC values for LFpen were 0.71 (inter) and 0.86 (intra) for permanent teeth and 0.94 (inter) and 0.90/0.99 for primary teeth. Kappa values for BW were 0.69 (inter) and 0.68/0.90 (intra) for permanent teeth and 0.64 (inter) and 0.89/0.89 for primary teeth. CONCLUSION LFpen presented better reproducibility for primary and permanent teeth and higher accuracy in detecting caries lesions at D1 threshold than BW for permanent teeth. LFpen should be used as an adjunct method for approximal caries detection.
Resumo:
The efficacy and tolerance of a novel microbial 6-phytase were investigated in rainbow trout, Oncorhynchus mykiss, and Nile tilapia, Oreochromis niloticus. Reference diets were sufficient in available phosphorus (P). The test diet limiting in available P was supplemented with phytase at 500, 1000, or 2000 phytase units/kg feed. The enzyme was effective in increasing total P apparent digestibility coefficient in relation to increasing the dose of phytase in rainbow trout and Nile tilapia. Zinc apparent digestibility improved in relation to phytase supplementation in rainbow trout. P release due to phytase supplementation ranged from 0.06 to 0.18% P/kg feed in rainbow trout and from 0.13 to 0.26% P/kg feed in Nile tilapia. A 58-d performance trial was conducted to evaluate tolerance of fish to phytase supplementation. Dietary treatments consisted of a basal diet without phytase or supplemented with 2000 and 200,000 phytase units/kg feed. Results indicate that this novel microbial 6-phytase is well tolerated by fish. Significant improvements for growth as well as feed conversion ratio were observed when the phytase was fed at 2000 phytase units/kg feed. This phytase is proven efficient in releasing P from phytate and could be added when plants are used for fish meal replacement in diets for salmonid and omnivorous fish.
Resumo:
This paper presents the performance of the ATLAS muon reconstruction during the LHC run with pp collisions at √s = 7–8 TeV in 2011–2012, focusing mainly on data collected in 2012. Measurements of the reconstruction efficiency and of the momentum scale and resolution, based on large reference samples of J/ψ → μμ, Z → μμ and ϒ → μμ decays, are presented and compared to Monte Carlo simulations. Corrections to the simulation, to be used in physics analysis, are provided. Over most of the covered phase space (muon |η| < 2.7 and 5 ≲ pT ≲ 100 GeV) the efficiency is above 99% and is measured with per-mille precision. The momentum resolution ranges from 1.7% at central rapidity and for transverse momentum pT ≅ 10 GeV, to 4% at large rapidity and pT ≅ 100 GeV. The momentum scale is known with an uncertainty of 0.05% to 0.2% depending on rapidity. A method for the recovery of final state radiation from the muons is also presented.
Resumo:
Background Tools to explore large compound databases in search for analogs of query molecules provide a strategically important support in drug discovery to help identify available analogs of any given reference or hit compound by ligand based virtual screening (LBVS). We recently showed that large databases can be formatted for very fast searching with various 2D-fingerprints using the city-block distance as similarity measure, in particular a 2D-atom pair fingerprint (APfp) and the related category extended atom pair fingerprint (Xfp) which efficiently encode molecular shape and pharmacophores, but do not perceive stereochemistry. Here we investigated related 3D-atom pair fingerprints to enable rapid stereoselective searches in the ZINC database (23.2 million 3D structures). Results Molecular fingerprints counting atom pairs at increasing through-space distance intervals were designed using either all atoms (16-bit 3DAPfp) or different atom categories (80-bit 3DXfp). These 3D-fingerprints retrieved molecular shape and pharmacophore analogs (defined by OpenEye ROCS scoring functions) of 110,000 compounds from the Cambridge Structural Database with equal or better accuracy than the 2D-fingerprints APfp and Xfp, and showed comparable performance in recovering actives from decoys in the DUD database. LBVS by 3DXfp or 3DAPfp similarity was stereoselective and gave very different analogs when starting from different diastereomers of the same chiral drug. Results were also different from LBVS with the parent 2D-fingerprints Xfp or APfp. 3D- and 2D-fingerprints also gave very different results in LBVS of folded molecules where through-space distances between atom pairs are much shorter than topological distances. Conclusions 3DAPfp and 3DXfp are suitable for stereoselective searches for shape and pharmacophore analogs of query molecules in large databases. Web-browsers for searching ZINC by 3DAPfp and 3DXfp similarity are accessible at www.gdb.unibe.ch webcite and should provide useful assistance to drug discovery projects.
Resumo:
This in vivo study aimed to evaluate the influence of contact points on the approximal caries detection in primary molars, by comparing the performance of the DIAGNOdent pen and visual-tactile examination after tooth separation to bitewing radiography (BW). A total of 112 children were examined and 33 children were selected. In three periods (a, b, and c), 209 approximal surfaces were examined: (a) examiner 1 performed visual-tactile examination using the Nyvad criteria (EX1); examiner 2 used DIAGNOdent pen (LF1) and took BW; (b) 1 week later, after tooth separation, examiner 1 performed the second visual-tactile examination (EX2) and examiner 2 used DIAGNOdent again (LF2); (c) after tooth exfoliation, surfaces were directly examined using DIAGNOdent (LF3). Teeth were examined by computed microtomography as a reference standard. Analyses were based on diagnostic thresholds: D1: D 0 = health, D 1 –D 4 = disease; D2: D 0 , D 1 = health, D 2 –D 4 = disease; D3: D 0 –D 2 = health, D 3 , D 4 = disease. At D1, the highest sensitivity/specificity were observed for EX1 (1.00)/LF3 (0.68), respectively. At D2, the highest sensitivity/ specificity were observed for LF3 (0.69)/BW (1.00), respectively. At D3, the highest sensitivity/specificity were observed for LF3 (0.78)/EX1, EX2 and BW (1.00). EX1 showed higher accuracy values than LF1, and EX2 showed similar values to LF2. We concluded that the visual-tactile examination showed better results in detecting sound surfaces and approximal caries lesions without tooth separation. However, the effectiveness of approximal caries lesion detection of both methods was increased by the absence of contact points. Therefore, regardless of the method of detection, orthodontic separating elastics should be used as a complementary tool for the diagnosis of approximal noncavitated lesions in primary molars.
Resumo:
The ratio of cystatin C (cysC) to creatinine (crea) is regarded as a marker of glomerular filtration quality associated with cardiovascular morbidities. We sought to determine reference intervals for serum cysC-crea ratio in seniors. Furthermore, we sought to determine whether other low-molecular weight molecules exhibit a similar behavior in individuals with altered glomerular filtration quality. Finally, we investigated associations with adverse outcomes. A total of 1382 subjectively healthy Swiss volunteers aged 60 years or older were enrolled in the study. Reference intervals were calculated according to Clinical & Laboratory Standards Institute (CLSI) guideline EP28-A3c. After a baseline exam, a 4-year follow-up survey recorded information about overall morbidity and mortality. The cysC-crea ratio (mean 0.0124 ± 0.0026 mg/μmol) was significantly higher in women and increased progressively with age. Other associated factors were hemoglobin A1c, mean arterial pressure, and C-reactive protein (P < 0.05 for all). Participants exhibiting shrunken pore syndrome had significantly higher ratios of 3.5-66.5 kDa molecules (brain natriuretic peptide, parathyroid hormone, β2-microglobulin, cystatin C, retinol-binding protein, thyroid-stimulating hormone, α1-acid glycoprotein, lipase, amylase, prealbumin, and albumin) and creatinine. There was no such difference in the ratios of very low-molecular weight molecules (urea, uric acid) to creatinine or in the ratios of molecules larger than 66.5 kDa (transferrin, haptoglobin) to creatinine. The cysC-crea ratio was significantly predictive of mortality and subjective overall morbidity at follow-up in logistic regression models adjusting for several factors. The cysC-crea ratio exhibits age- and sex-specific reference intervals in seniors. In conclusion, the cysC-crea ratio may indicate the relative retention of biologically active low-molecular weight compounds and can independently predict the risk for overall mortality and morbidity in the elderly.
Resumo:
The purpose of this study was to assess the accuracy and precision of airborne volatile organic compound (VOC) concentrations measured using passive air samplers (3M 3500 organic vapor monitors) over extended sampling durations (9 and 15 days). A total of forty-five organic vapor monitor samples were collected at a State of Texas air monitoring site during two different sampling periods (July/August and November 2008). The results of this study indicate that for most of the tested compounds, there was no significant difference between long-term (9 or 15 days) sample concentrations and the means of parallel consecutive short-term (3 days) sample concentrations. Biases of 9 or 15-day measurements vs. consecutive 3-day measurements showed considerable variability. Those compounds that had percent bias values of <10% are suggested as acceptable for long-term sampling (9 and 15 days). Of the twenty-one compounds examined, 10 compounds are classified as acceptable for long-term sampling; these include m,p-xylene, 1,2,4-trimethylbenzene, n-hexane, ethylbenzene, benzene, toluene, o-xylene, d-limonene, dimethylpentane and methyl tertbutyl ether. The ratio of sampling procedure variability relative to variability within days was approximately 1.89 for both sampling periods for the 3-day vs. 9-day comparisons and approximately 2.19 for both sampling periods for the 3-day vs. 15-day comparisons. Considerably higher concentrations of most VOCs were measured during the November sampling period compared to the July/August period. These differences may be a result of varying meteorological conditions during these two time periods, e.g., the differences in wind direction, and wind speed. Further studies are suggested to further evaluate the accuracy and precision of 3M 3500 organic vapor monitors over extended sampling durations. ^
Resumo:
Evaluation methods for assessing the performance of non-profit funders are lacking. The purpose of the research was to create a comprehensive framework that systematically assesses the goals and objectives of a funder, how these relate to the funder's allocation of resources, and the potential impact of programs and services selected by the funder for resource allocation to address organizational goals and objectives. The Houston Affiliate of Susan G. Komen for the Cure, a local chapter of a national breast cancer awareness advocacy organization, was selected as the funding agency whose performance assessment was to assist in the creation of this framework. Evaluation approaches from the government sector were adapted and incorporated into the research to guide the methods used to answer the three research questions corresponding to the three phases of research within the study: (1) what are the funding goals and objectives of the Affiliate?; (2) what allocation scheme does the organization use to address these goals and objectives and select programs for funding?; and, (3) to what extent do the programs funded by the Affiliate have potential long-term impact? ^ Within the first stage of the research, document reviews of the Affiliate's mission-based documents and bylaws and interviews with organizational and community informants revealed a highly latent constellation of broad objectives that were not formalized into one guiding document, thus creating gaps in management and governance. Within the second phase of the research, reviews of grant applications from the 2008-2009 funding cycle and interviews with employees and volunteers familiar with the funding process revealed competing ideas regarding resource allocation in light of vague organizational documents describing funding goals and objectives. Within the final stage of the research, these findings translated to the Affiliate selecting programs with highly varying potential long-term impact with regards to addressing goals and objectives relating to breast cancer education, screening, diagnostics, treatment, and support. The resulting performance assessment framework, consisting of three phases of research utilizing organizational documents and key informant interviews, demonstrated the importance of clearly defined funding goals and objectives, reference documents and committee participation within the funding process, and regular reviews of potential long-term impact for selected programs, all supported by the active participation and governance of a funder's Board of Directors.^
Resumo:
Considerable evidence suggests that central cholinergic neurons participate in either acquisition, storage or retrieval of information. Experiments were designed to evaluate information processing in mice following either reversible or irreversible impairment in central cholinergic activity. The cholinergic receptor antagonists, atropine and methylatropine were used to reversibly inhibit cholinergic transmission. Irreversible impairment in central cholinergic function was achieved by central administration of the cholinergic-specific neurotoxins, N-ethyl-choline aziridinium (ECA) and N-ethyl-acetylcholine aziridinium (EACA).^ ECA and EACA appear to act by irreversible inhibition of high affinity choline uptake (proposed rate-limiting step in acetylcholine synthesis). Intraventricular administration of ECA or EACA produced persistent reduction in hippocampal choline acetyltransferase activity. Other neuronal systems and brain regions showed no evidence of toxicity.^ Mice treated with either ECA or EACA showed behavioral deficits associated with cholinergic dysfunction. Passive avoidance behavior was significantly impaired by cholinotoxin treatment. Radial arm maze performance was also significantly impaired in cholinotoxin-treated animals. Deficits in radial arm maze performance were transient, however, such that rapid and apparent complete behavioral recovery was seen during retention testing. The centrally active cholinergic receptor antagonist atropine also caused significant impairment in radial arm maze behavior, while equivalent doses of methylatropine were without effect.^ The relative effects of cholinotoxin and receptor antagonist treatment on short-term (working) memory and long-term (reference) memory in radial arm maze behavior were examined. Maze rotation studies indicated that there were at least two different response strategies which could result in accurate maze performance. One strategy involved the use of response algorithms and was considered to be a function of reference memory. Another strategy appeared to be primarily dependent on spatial working memory. However, all behavioral paradigms with multiple trails have reference memory requirements (i.e. information useful over all trials). Performance was similarly affected following either cholinotoxin or anticholinergic treatment, regardless of the response strategy utilized. In addition, rates of behavioral recovery following cholinotoxin treatment were similar between response groups. It was concluded that both cholinotoxin and anticholinergic treatment primarily resulted in impaired reference memory processes. ^