988 resultados para Passive solar techniques
Resumo:
To comply with natural gas demand growth patterns and Europe´s import dependency, the gas industry needs to organize an efficient upstream infrastructure. The best location of Gas Supply Units – GSUs and the alternative transportation mode – by phisical or virtual pipelines, are the key of a successful industry. In this work we study the optimal location of GSUs, as well as determining the most efficient allocation from gas loads to sources, selecting the best transportation mode, observing specific technical restrictions and minimizing system total costs. For the location of GSUs on system we use the P-median problem, for assigning gas demands nodes to source facilities we use the classical transportation problem. The developed model is an optimisation-based approach, based on a Lagrangean heuristic, using Lagrangean relaxation for P-median problems – Simple Lagrangean Heuristic. The solution of this heuristic can be improved by adding a local search procedure - the Lagrangean Reallocation Heuristic. These two heuristics, Simple Lagrangean and Lagrangean Reallocation, were tested on a realistic network - the primary Iberian natural gas network, organized with 65 nodes, connected by physical and virtual pipelines. Computational results are presented for both approaches, showing the location gas sources and allocation loads arrangement, system total costs and gas transportation mode.
Resumo:
In recent years, Power Systems (PS) have experimented many changes in their operation. The introduction of new players managing Distributed Generation (DG) units, and the existence of new Demand Response (DR) programs make the control of the system a more complex problem and allow a more flexible management. An intelligent resource management in the context of smart grids is of huge important so that smart grids functions are assured. This paper proposes a new methodology to support system operators and/or Virtual Power Players (VPPs) to determine effective and efficient DR programs that can be put into practice. This method is based on the use of data mining techniques applied to a database which is obtained for a large set of operation scenarios. The paper includes a case study based on 27,000 scenarios considering a diversity of distributed resources in a 32 bus distribution network.
Resumo:
The growing importance and influence of new resources connected to the power systems has caused many changes in their operation. Environmental policies and several well know advantages have been made renewable based energy resources largely disseminated. These resources, including Distributed Generation (DG), are being connected to lower voltage levels where Demand Response (DR) must be considered too. These changes increase the complexity of the system operation due to both new operational constraints and amounts of data to be processed. Virtual Power Players (VPP) are entities able to manage these resources. Addressing these issues, this paper proposes a methodology to support VPP actions when these act as a Curtailment Service Provider (CSP) that provides DR capacity to a DR program declared by the Independent System Operator (ISO) or by the VPP itself. The amount of DR capacity that the CSP can assure is determined using data mining techniques applied to a database which is obtained for a large set of operation scenarios. The paper includes a case study based on 27,000 scenarios considering a diversity of distributed resources in a 33 bus distribution network.
Resumo:
Important research effort has been devoted to the topic of optimal planning of distribution systems. The non linear nature of the system, the need to consider a large number of scenarios and the increasing necessity to deal with uncertainties make optimal planning in distribution systems a difficult task. Heuristic techniques approaches have been proposed to deal with these issues, overcoming some of the inherent difficulties of classic methodologies. This paper considers several methodologies used to address planning problems of electrical power distribution networks, namely mixedinteger linear programming (MILP), ant colony algorithms (AC), genetic algorithms (GA), tabu search (TS), branch exchange (BE), simulated annealing (SA) and the Bender´s decomposition deterministic non-linear optimization technique (BD). Adequacy of theses techniques to deal with uncertainties is discussed. The behaviour of each optimization technique is compared from the point of view of the obtained solution and of the methodology performance. The paper presents results of the application of these optimization techniques to a real case of a 10-kV electrical distribution system with 201 nodes that feeds an urban area.
Resumo:
O presente trabalho tem como objectivo efectuar a avaliação económica e determinar a viabilidade com e sem os incentivos fiscais de duas tecnologias de conversão de duas fontes distinta e emergentes de energia renovável, o Concentrador Cilindro-parabólico e a Torre Solar para a energia solar termoeléctrica e a Coluna de Água Oscilante e o Pelamis para a energia das ondas. Realiza-se uma curta abordagem à energia Solar e à energia dos Oceanos, e às tecnologias existentes para estes tipos de energia renovável. Apresenta-se um estudo do potencial em Portugal e no Mindo, das tecnologias abordadas neste trabalho. É desenvolvido o modelo de conversão de energia para as centrais solares termoeléctricas e utilizado o modelo de superfície de potência para as centrais de energia das ondas adaptado de António Falcão. As centrais são modeladas por meio de uma folha de cálculo, onde é calculada a energia produzida em Mértola e São Pedro de Moel (energia solar termoeléctrica e das ondas respectivamente) consoante o recurso do local. É feita a avaliação económica para quatro cenários designados como optimista, base, pessimista e base sem aplicação da tarifa bonificada, e é realizada uma análise de sensibilidade do VAL a diversas variáveis. Conclui-se sobre a viabilidade dos vários cenários e sobre possíveis alterações à tarifa binificada en consequência dos resultados obtidos. Segundo os pressupostos deste trabalho concluíu-se que a tarifa bonificada é demasiado elevada para os projectos em energia solar de concentração e demasiado baixa para projectos em energia das ondas.
Resumo:
This paper consist in the establishment of a Virtual Producer/Consumer Agent (VPCA) in order to optimize the integrated management of distributed energy resources and to improve and control Demand Side Management DSM) and its aggregated loads. The paper presents the VPCA architecture and the proposed function-based organization to be used in order to coordinate the several generation technologies, the different load types and storage systems. This VPCA organization uses a frame work based on data mining techniques to characterize the costumers. The paper includes results of several experimental tests cases, using real data and taking into account electricity generation resources as well as consumption data.
Resumo:
Control Centre operators are essential to assure a good performance of Power Systems. Operators’ actions are critical in dealing with incidents, especially severe faults, like blackouts. In this paper we present an Intelligent Tutoring approach for training Portuguese Control Centre operators in incident analysis and diagnosis, and service restoration of Power Systems, offering context awareness and an easy integration in the working environment.
Resumo:
O presente documento tem como principal objectivo efectuar o projecto de dimensionamento de um sistema de águas quentes sanitárias para uma escola. Numa primeira fase foi elaborado uma pesquisa sobre o contexto energético, a nível mundial, europeu e nacional, bem como o seu contexto jurídico a nível europeu e nacional, e uma explicação superficial sobre os fundamentos da energia solar, onde se foca a importância da radiação solar e os vários tipos de sistemas solares térmicos, bem como os seus constituintes. Segue-se a abordagem ao caso de estudo onde foram efectuados inicialmente inquéritos como forma de determinar os consumos de água quente utilizada nessa escola. Continuou-se o estudo efectuando-se a variação de duas características do sistema solar: o tamanho dos depósitos e o tipo de colectores solares a aplicar. Após as simulações efectuadas para a determinação das soluções a aplicar ao sistemasolar e apresentadas ao longo do presente documento, foram efectuadas análises económicas como forma de se verificar a viabilidade do sistema a aplicar. Por último foram elaboradas conclusões sobre o sistema a aplicar e apresentados alguns cenários financeiros do mesmo.
Resumo:
Titanium films have been deposited on stainless steel metal sheets using dc magnetron sputtering technique at different substrate temperatures. The structure of the titanium films strongly depend on the substrate temperature. The titanium film deposited at the substrate temperature lower than 300 ◦C has a loose flat sheet grains structure and the titanium film prepared at the substrate temperature higher than 500 ◦C has a dense nubby grains structure. The DSSC assembled using stainless steel sheet coated with titanium film deposited at high substrate temperature has a low charge transfer resistance in the TiO2/Ti interface and results in a high conversion efficiency. The DSSC assembled using stainless steel sheet coated with titanium film deposited at temperature higher than 500 ◦C has higher conversion efficiency than that assembled using titanium metal sheet as the substrate. The maximum conversion efficiency, 2.26% is obtained for DSSC assembled using stainless steel sheet coated with titanium film deposited at 700 ◦C substrate temperature, which is about 70% of the conversion efficiency of the FTO reference cell used in this study.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde.
Resumo:
Amorphous SiC tandem heterostructures are used to filter a specific band, in the visible range. Experimental and simulated results are compared to validate the use of SiC multilayered structures in applications where gain compensation is needed or to attenuate unwanted wavelengths. Spectral response data acquired under different frequencies, optical wavelength control and side irradiations are analyzed. Transfer function characteristics are discussed. Color pulsed communication channels are transmitted together and the output signal analyzed under different background conditions. Results show that under controlled wavelength backgrounds, the device sensitivity is enhanced in a precise wavelength range and quenched in the others, tuning or suppressing a specific band. Depending on the background wavelength and irradiation side, the device acts either as a long-, a short-, or a band-rejection pass filter. An optoelectronic model supports the experimental results and gives insight on the physics of the device.
Resumo:
Introdução: As teorias etiológicas recíprocas que relacionam as disfunções da articulação temporo mandibular (ATM) com as disfunções da coluna cervical, os seus critérios de diagnóstico e formas de tratamento, não reúnem consenso, constituindo, actualmente, uma temática de debate e investigação. Objectivo: Descrever a avaliação e intervenção em fisioterapia, e os seus resultados numa utente com disfunção do complexo crânio-cervico-mandibular. Métodos: Foi realizado um estudo observacional descritivo, do tipo estudo de caso, reportando-se a uma enfermeira, de 28 anos, com quadro sintomatológico compatível com disfunção crânio-cervico-mandibular, com antecedentes de condilectomia e artroplastia da ATM, aos 14 anos. Inicialmente a utente apresentava dor irradiada na região cervical (7/10) e limitação dos movimentos articulares da coluna cervical. Referia, também, dor na região do ptérion direito (6/10), limitação dos movimentos da mandíbula, desvio lateral na abertura da boca e dificuldades funcionais na mastigação. A avaliação inicial e final (após tratamento), foi efectuada recorrendo-se à utilização do Goniometro CROM e da Therabite Range of Motion Scale, para medição das amplitudes articulares da cervical e ATM, respectivamente; Estetoscópio, para avaliação dos sons articulares da ATM; Escala Visual Analógica para graduação da dor. A intervenção decorreu ao longo de 10 sessões, bissemanais. No tratamento, foram aplicadas técnicas sobre os trigers points da musculatura cervical e músculos da mastigação; Mobilização passiva da cervical e ATM; Manipulação dos segmentos vertebrais cervicais e torácicos; Streching e técnicas de energia muscular; Técnicas funcionais para a ATM; Técnicas miofasciais para a coluna cervical e ATM; Exercícios de controlo motor da coluna cervical. Resultados: No final do tratamento, as amplitudes dos movimentos cervicais estavam completas e sem dor (0/10), mantendo, sensibilidade dolorosa à palpação das espinhosas de C5-C6 (1/10). Relativamente à ATM, verifica-se a abolição da dor (0/10) e a ausência do desvio lateral da mandíbula na abertura da boca, bem como, o aumento das amplitudes de movimento na abertura da boca (33 para 36 mm), e no desvio lateral esquerdo (2 para 2,8 mm). Conclusão: os resultados sugerem que a intervenção, com recurso a técnicas de terapia manual, no caso em estudo, parecem surtir efeitos positivos no quadro sintomatológico e funcional da utente.
Resumo:
Throughout the world, epidemiological studies were established to examine the relationship between air pollution and mortality rates and adverse respiratory health effects. However, despite the years of discussion the correlation between adverse health effects and atmospheric pollution remains controversial, partly because these studies are frequently restricted to small and well-monitored areas. Monitoring air pollution is complex due to the large spatial and temporal variations of pollution phenomena, the high costs of recording instruments, and the low sampling density of a purely instrumental approach. Therefore, together with the traditional instrumental monitoring, bioindication techniques allow for the mapping of pollution effects over wide areas with a high sampling density. In this study, instrumental and biomonitoring techniques were integrated to support an epidemiological study that will be developed in an industrial area located in Gijon in the coastal of central Asturias, Spain. Three main objectives were proposed to (i) analyze temporal patterns of PM10 concentrations in order to apportion emissions sources, (ii) investigate spatial patterns of lichen conductivity to identify the impact of the studied industrial area in air quality, and (iii) establish relationships amongst lichen conductivity with some site-specific characteristics. Samples of the epiphytic lichen Parmelia sulcata were transplanted in a grid of 18 by 20 km with an industrial area in the center. Lichens were exposed for a 5-mo period starting in April 2010. After exposure, lichen samples were soaked in 18-MΩ water aimed at determination of water electrical conductivity and, consequently, lichen vitality and cell damage. A marked decreasing gradient of lichens conductivity relative to distance from the emitting sources was observed. Transplants from a sampling site proximal to the industrial area reached values 10-fold higher than levels far from it. This finding showed that lichens reacted physiologically in the polluted industrial area as evidenced by increased conductivity correlated to contamination level. The integration of temporal PM10 measurements and analysis of wind direction corroborated the importance of this industrialized region for air quality measurements and identified the relevance of traffic for the urban area.
Resumo:
This work aims at investigating the impact of treating breast cancer using different radiation therapy (RT) techniques – forwardly-planned intensity-modulated, f-IMRT, inversely-planned IMRT and dynamic conformal arc (DCART) RT – and their effects on the whole-breast irradiation and in the undesirable irradiation of the surrounding healthy tissues. Two algorithms of iPlan BrainLAB treatment planning system were compared: Pencil Beam Convolution (PBC) and commercial Monte Carlo (iMC). Seven left-sided breast patients submitted to breast-conserving surgery were enrolled in the study. For each patient, four RT techniques – f-IMRT, IMRT using 2-fields and 5-fields (IMRT2 and IMRT5, respectively) and DCART – were applied. The dose distributions in the planned target volume (PTV) and the dose to the organs at risk (OAR) were compared analyzing dose–volume histograms; further statistical analysis was performed using IBM SPSS v20 software. For PBC, all techniques provided adequate coverage of the PTV. However, statistically significant dose differences were observed between the techniques, in the PTV, OAR and also in the pattern of dose distribution spreading into normal tissues. IMRT5 and DCART spread low doses into greater volumes of normal tissue, right breast, right lung and heart than tangential techniques. However, IMRT5 plans improved distributions for the PTV, exhibiting better conformity and homogeneity in target and reduced high dose percentages in ipsilateral OAR. DCART did not present advantages over any of the techniques investigated. Differences were also found comparing the calculation algorithms: PBC estimated higher doses for the PTV, ipsilateral lung and heart than the iMC algorithm predicted.