450 resultados para POLIETILENO


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciência Odontólogica - FOA

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Ciência do Solo) - FCAV

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciência Odontólogica - FOA

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Química - IQ

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sealer 26® cement contains bisphenol epoxy resin associated with calcium hydroxide, presenting smaller radiopacity than other endodontic cements. Aiming to improve this property, iodoform has been added in its composition. However, this addition's possible changes in physical and chemical properties still need to be studied. OBJECTIVE: To evaluate the apical sealing ability, solubility, and pH of Sealer 26® alone or with iodoform, at several proportions. MATERIAL AND METHODS: Three experimental mixtures of Sealer 26®, alone or with iodoform, were prepared and subjected to solubility test. Additionally, these combinations were inserted into polyethylene tubes and immersed in distilled water, and, their pH was evaluated after 24-h and 7-day periods. Subsequently, forty roots of extracted lower incisors subdivided into four groups of 10 specimens each, were retrograde filled with one of the previously described mixtures and gutta-percha points. The roots were immersed in Rhodamine B, under vacuum, for 72 hours. After this period, the specimens were longitudinally sectioned, root fragments photographed, these images scanned, and apical infiltration measured by Image tool software. The obtained data were subjected to statistical analysis, at a significance level of 5%. RESULTS: Marginal leakage and solubility tests did not show any difference among the experimental groups (p > 0.05). pH analysis was only statistically different at 24-h period and between Sealer 26® alone and 1.1g iodoform group (p < 0.05). CONCLUSION: The presence of iodoform in Sealer 26®, at the used proportions, did not alter the solubility, apical marginal leakage and pH properties of the original cement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to develop, implement and evaluate the performance of a new type of bioreactor for anaerobic treatment of wastewater using different filling materials like trickling filters post-reactor. This bioreactor has mixed characteristics of the UASB reactors and horizontal flow from the point of view of removal of BOD (Biochemical Oxygen Demand) ssed (settled solids), TS (Total Solids), SS (Suspended Solid), SD (Dissolved Solids) and turbidity. The experimental model consists of a bioreactor with a volume of 12 m³, 2/3 filled by fluidized bed and 1/3 for fixed. The fluidized bed is made of polystyrene plates used as a system percolation and compartmentalized trickling filters, where each compartment was filled with a support medium with different characteristics (gravel number 4, plastic rings of polystyrene, PET and HDPE) . In addition, the output of a filter system was installed three entries filled with activated carbon. The bioreactor was installed in private residence in the city of Igarapava-SP (20° 02'40.18"S and 47° 45'01.36" W). The system was highly efficient as the removal of organic contaminant load 92% on average reducing the BOD, a significant result when compared to other anaerobic systems. For the other parameters, the mean reduction was 96% for turbidity, 99% ssed, 67.5% ST, 57% SD and 88% of SS. As for its operation the system was capable of operating in continuous flow without the need for maintenance during the entire period of evaluation and without energy, as it operates taking advantage of the natural slope of the terrain where it is installed. The environmental impacts were minimized due to the preservation of local vegetation allowing the ecosystem to remain unchanged beyond the prototype was completely sealed preventing exhalation of odors and therefore not causing inconvenience to neighboring populations. Given these facts it was concluded that the prototype is shown to be highly feasible deployed as a new alternative for treatment of sewage in rural and urban settings (individual homes, condos, farms, ranches, etc.) Due to ease of design and operability, and sustainability at all stages of execution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the in vivo Bronchoalveolar lavage (BAL)technique by endoscopy in tapirs (Tapirus terrestris) with clinicalsigns of tuberculosis. The technique was performed in two tapirs, male and female,from Curitiba Zoo, Paraná, Brazil. A flexible endoscope and a polyethylene catheterwere used after the chemical restraint of the animals. For BAL technique, 60mL ofsaline 0.9% were infused with a polyethylene catheter, introduced by the endoscope'working channel, and 15mL of BAL were recovered, analyzed and submitted tocytocentrifugation. Slides were stained by Papanicolaou, periodic acid-Schiff (PAS)and Ziehl-Neelsen methods contained high quantity of inflammatory cells on lightmicroscopy (macrophages 27.5%, lymphocytes 0.5%, neutrophis 67% and eosinophis 5%).BAL samples were submitted to culture, bacilloscopy and PCR and were negative forboth animals. Based on this study, it was concluded that the bronchoalveolar lavagetechnique in tapirs is feasible, simple, noninvasive, practical and fast, providingan important clinical information in vivo regarding the functionalstatus of the lower respiratory tract.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O caqui apresenta uma safra curta, sendo necessário estender seu período de comercialização utilizando técnicas adequadas de armazenamento. O objetivo deste trabalho foi avaliar o uso da radiação gama na qualidade pós-colheita de caquis 'Giombo' destanizados. Frutos colhidos meio-maduros e com aproximadamente 50 % da coloração verde, foram destanizados, acondicionados em bandejas de poliestireno expandido (EPS), revestidas por filme plástico de polietileno de baixa densidade (PEBD) e submetidos à radiação gama (60Co). Os frutos foram armazenados durante 35 dias, sob refrigeração (0±0,5 ºC e 85 ± 0,5% UR). Os tratamentos realizados foram: T1 - 0,0 kGy; T2 - 0,3 kGy; T3 - 0,6 kGy; T4 - 0,9 kGy; T5 - 1,2 kGy. As análises realizadas a cada 7 dias foram: perda de massa, atividade respiratória, teores de sólidos solúveis (SS), ácido ascórbico, acidez titulável (AT) e relação SS/AT. Os frutos submetidos à dose de 0,6 kGy apresentaram o menor percentual de perda de massa e produção de CO2 ao longo do período experimental. Os teores de SS e AT permaneceram estáveis e sem diferenças devido às doses de irradiação aplicadas. Os tratamentos com 0,3 KGy e 0,6 KGy foram os mais eficazes na manutenção da firmeza nos caquis. Nos teores de ácido ascórbico, observou-se redução ao longo do período experimental, sendo os menores valores apresentados para a maior dose de irradiação (1,2 KGy).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this work was to evaluate the biological compatibility of the Sealapex, Apexit, Sealer 26 and Ketac Endo endodontic cements. Polyethylene tubes containing these cements were implanted in the subcutaneous tissue of 40 (forty) rats. The animals were sacrificed after 14 and 90 days. A descriptive analysis of the reactions found in the connective tissue by contact with the cements was performed. The magnitude of inflammatory infiltrate, the presence and predominance of cell types and their distribution as to the filling material and reparative phenomena, such as fibroblastic and angioblastic proliferation and formation of fibrous capsules, were subjectively measured. After 90 days, all cements presented statistically significant reduction of the inflammatory reaction, presence of a fibrous tissue capsule in contact with the opening of the tubes containing the filling materials, and reduction of fibroblastic proliferation. Angioblastic proliferation decreased only for the Sealer 26 and Ketac Endo groups. All cements tested were either partially or totally phagocyted, and the mildest inflammatory response was found for the Sealer 26 group at both evaluation periods.