964 resultados para Noninvasive electrocardiography


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Catecholaminergic polymorphic ventricular tachycardia (CPVT) is an inherited arrhythmia syndrome associated with mutations in the cardiac ryanodine receptor gene (Ryr2) in the majority of patients. Previous studies of CPVT patients mainly involved probands, so current insight into disease penetrance, expression, genotype-phenotype correlations, and arrhythmic event rates in relatives carrying the Ryr2 mutation is limited. METHODS AND RESULTS: One-hundred sixteen relatives carrying the Ryr2 mutation from 15 families who were identified by cascade screening of the Ryr2 mutation causing CPVT in the proband were clinically characterized, including 61 relatives from 1 family. Fifty-four of 108 antiarrhythmic drug-free relatives (50%) had a CPVT phenotype at the first cardiological examination, including 27 (25%) with nonsustained ventricular tachycardia. Relatives carrying a Ryr2 mutation in the C-terminal channel-forming domain showed an increased odds of nonsustained ventricular tachycardia (odds ratio, 4.1; 95% CI, 1.5-11.5; P=0.007, compared with N-terminal domain) compared with N-terminal domain. Sinus bradycardia was observed in 19% of relatives, whereas other supraventricular dysrhythmias were present in 16%. Ninety-eight (most actively treated) relatives (84%) were followed up for a median of 4.7 years (range, 0.3-19.0 years). During follow-up, 2 asymptomatic relatives experienced exercise-induced syncope. One relative was not being treated, whereas the other was noncompliant. None of the 116 relatives died of CPVT during a 6.7-year follow-up (range, 1.4-20.9 years). CONCLUSIONS: Relatives carrying an Ryr2 mutation show a marked phenotypic diversity. The vast majority do not have signs of supraventricular disease manifestations. Mutation location may be associated with severity of the phenotype. The arrhythmic event rate during follow-up was low.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Black-blood MR coronary vessel wall imaging may become a powerful tool for the quantitative and noninvasive assessment of atherosclerosis and positive arterial remodeling. Although dual-inversion recovery is currently the gold standard, optimal lumen-to-vessel wall contrast is sometimes difficult to obtain, and the time window available for imaging is limited due to competing requirements between blood signal nulling time and period of minimal myocardial motion. Further, atherosclerosis is a spatially heterogeneous disease, and imaging at multiple anatomic levels of the coronary circulation is mandatory. However, this requirement of enhanced volumetric coverage comes at the expense of scanning time. Phase-sensitive inversion recovery has shown to be very valuable for enhancing tissue-tissue contrast and for making inversion recovery imaging less sensitive to tissue signal nulling time. This work enables multislice black-blood coronary vessel wall imaging in a single breath hold by extending phase-sensitive inversion recovery to phase-sensitive dual-inversion recovery, by combining it with spiral imaging and yet relaxing constraints related to blood signal nulling time and period of minimal myocardial motion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coronary magnetic resonance angiography (MRA) is a powerful noninvasive technique with high soft-tissue contrast for the visualization of the coronary anatomy without X-ray exposure. Due to the small dimensions and tortuous nature of the coronary arteries, a high spatial resolution and sufficient volumetric coverage have to be obtained. However, this necessitates scanning times that are typically much longer than one cardiac cycle. By collecting image data during multiple RR intervals, one can successfully acquire coronary MR angiograms. However, constant cardiac contraction and relaxation, as well as respiratory motion, adversely affect image quality. Therefore, sophisticated motion-compensation strategies are needed. Furthermore, a high contrast between the coronary arteries and the surrounding tissue is mandatory. In the present article, challenges and solutions of coronary imaging are discussed, and results obtained in both healthy and diseased states are reviewed. This includes preliminary data obtained with state-of-the-art techniques such as steady-state free precession (SSFP), whole-heart imaging, intravascular contrast agents, coronary vessel wall imaging, and high-field imaging. Simultaneously, the utility of electron beam computed tomography (EBCT) and multidetector computed tomography (MDCT) for the visualization of the coronary arteries is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ECG criteria for left ventricular hypertrophy (LVH) have been almost exclusively elaborated and calibrated in white populations. Because several interethnic differences in ECG characteristics have been found, the applicability of these criteria to African individuals remains to be demonstrated. We therefore investigated the performance of classic ECG criteria for LVH detection in an African population. Digitized 12-lead ECG tracings were obtained from 334 African individuals randomly selected from the general population of the Republic of Seychelles (Indian Ocean). Left ventricular mass was calculated with M-mode echocardiography and indexed to body height. LVH was defined by taking the 95th percentile of body height-indexed LVM values in a reference subgroup. In the entire study sample, 16 men and 15 women (prevalence 9.3%) were finally declared to have LVH, of whom 9 were of the reference subgroup. Sensitivity, specificity, accuracy, and positive and negative predictive values for LVH were calculated for 9 classic ECG criteria, and receiver operating characteristic curves were computed. We also generated a new composite time-voltage criterion with stepwise multiple linear regression: weighted time-voltage criterion=(0.2366R(aVL)+0.0551R(V5)+0.0785S(V3)+ 0.2993T(V1))xQRS duration. The Sokolow-Lyon criterion reached the highest sensitivity (61%) and the R(aVL) voltage criterion reached the highest specificity (97%) when evaluated at their traditional partition value. However, at a fixed specificity of 95%, the sensitivity of these 10 criteria ranged from 16% to 32%. Best accuracy was obtained with the R(aVL) voltage criterion and the new composite time-voltage criterion (89% for both). Positive and negative predictive values varied considerably depending on the concomitant presence of 3 clinical risk factors for LVH (hypertension, age >/=50 years, overweight). Median positive and negative predictive values of the 10 ECG criteria were 15% and 95%, respectively, for subjects with none or 1 of these risk factors compared with 63% and 76% for subjects with all of them. In conclusion, the performance of classic ECG criteria for LVH detection was largely disparate and appeared to be lower in this population of East African origin than in white subjects. A newly generated composite time-voltage criterion might provide improved performance. The predictive value of ECG criteria for LVH was considerably enhanced with the integration of information on concomitant clinical risk factors for LVH.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The early detection of cardiac organ damage in clinical practice is primordial for cardiovascular risk profiling of patients with hypertension. In this respect the determination of microalbuminuria is very appealing because it increasingly appears to be the most cost-effective means to identify cardiovascular and renal complications. Considering the treatment of patients with target organ damage, blockers of the renin-angiotensin system have a key position as they are very effective in regressing left ventricular hypertrophy, lowering urinary albumin excretion and delaying the progression of nephropathy. In high-risk patients with atherosclerosis, the use of a blocker of the renin-angiotensin system is also appealing, and it appears increasingly judicious to combine such a blocker with a calcium antagonist whenever required to control blood pressure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: On September 11, 2001, terrorists attacked the United States. By coincidence, a North Carolina highway patrol trooper was wearing an ambulatory ECG Holter monitor at this time as part of an air pollution study. METHODS: Heart rate variability parameters were analyzed: standard deviation of normal to normal beat intervals (SDNN) and percentage of interval differences >50 ms (PNN50). RESULTS: The trooper's heart rate variability changed immediately after learning about the terrorist attacks. Heart rate increased and PNN50 decreased, while SDNN increased strongly. CONCLUSIONS: These changes suggest strong emotional sympathetic stress associated with parasympathetic withdrawal in response to the news about the terrorist attack. [Authors]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

IMPLICATIONS: A new combined ear sensor was tested for accuracy in 20 critically ill children. It provides noninvasive and continuous monitoring of arterial oxygen saturation, arterial carbon dioxide tension, and pulse rate. The sensor proved to be clinically accurate in the tested range.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: Brugada syndrome (BrS) is characterized by arrhythmias leading to sudden cardiac death. BrS is caused, in part, by mutations in the SCN5A gene, which encodes the sodium channel alpha-subunit Na(v)1.5. Here, we aimed to characterize the biophysical properties and consequences of a novel BrS SCN5A mutation. METHODS AND RESULTS: SCN5A was screened for mutations in a male patient with type-1 BrS pattern ECG. Wild-type (WT) and mutant Na(v)1.5 channels were expressed in HEK293 cells. Sodium currents (I(Na)) were analysed using the whole-cell patch-clamp technique at 37 degrees C. The electrophysiological effects of the mutation were simulated using the Luo-Rudy model, into which the transient outward current (I(to)) was incorporated. A new mutation (C1850S) was identified in the Na(v)1.5 C-terminal domain. In HEK293 cells, mutant I(Na) density was decreased by 62% at -20 mV. Inactivation of mutant I(Na) was accelerated in a voltage-dependent manner and the steady-state inactivation curve was shifted by 11.6 mV towards negative potentials. No change was observed regarding activation characteristics. Altogether, these biophysical alterations decreased the availability of I(Na). In the simulations, the I(to) density necessary to precipitate repolarization differed minimally between the two genotypes. In contrast, the mutation greatly affected conduction across a structural heterogeneity and precipitated conduction block. CONCLUSION: Our data confirm that mutations of the C-terminal domain of Na(v)1.5 alter the inactivation of the channel and support the notion that conduction alterations may play a significant role in the pathogenesis of BrS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Human arteries affected by atherosclerosis are characterized by altered wall viscoelastic properties. The possibility of noninvasively assessing arterial viscoelasticity in vivo would significantly contribute to the early diagnosis and prevention of this disease. This paper presents a noniterative technique to estimate the viscoelastic parameters of a vascular wall Zener model. The approach requires the simultaneous measurement of flow variations and wall displacements, which can be provided by suitable ultrasound Doppler instruments. Viscoelastic parameters are estimated by fitting the theoretical constitutive equations to the experimental measurements using an ARMA parameter approach. The accuracy and sensitivity of the proposed method are tested using reference data generated by numerical simulations of arterial pulsation in which the physiological conditions and the viscoelastic parameters of the model can be suitably varied. The estimated values quantitatively agree with the reference values, showing that the only parameter affected by changing the physiological conditions is viscosity, whose relative error was about 27% even when a poor signal-to-noise ratio is simulated. Finally, the feasibility of the method is illustrated through three measurements made at different flow regimes on a cylindrical vessel phantom, yielding a parameter mean estimation error of 25%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

NovoTTF-100A (TTF) is a portable device delivering low-intensity, intermediate-frequency, alternating electric fields using noninvasive, disposable scalp electrodes. TTF interferes with tumor cell division, and it has been approved by the US Food and Drug Administration (FDA) for the treatment of recurrent glioblastoma (rGBM) based on data from a phase III trial. This presentation describes the updated survival data 2 years after completing recruitment. Adults with rGBM (KPS ≥ 70) were randomized (stratified by surgery and center) to either continuous TTF (20-24 h/day, 7 days/week) or efficacious chemotherapy based on best physician choice (BPC). The primary endpoint was overall survival (OS), and secondary endpoints were PFS6, 1-year survival, and QOL. Patients were randomized (28 US and European centers) to either TTF alone (n ¼ 120) or BPC (n ¼ 117). Patient characteristics were balanced, median age was 54 years (range, 23-80 years), and median KPS was 80 (range, 50-100). One quarter of the patients had debulking surgery, and over half of the patients were at their second or later recurrence. OS in the intent-to-treat (ITT) population was equivalent in TTF versus BPC patients (median OS, 6.6vs. 6.0 months; n ¼ 237; p ¼ 0.26; HR ¼ 0.86). With a median follow-up of 33.6 months, long-term survival in the TTF group was higher than that in the BPC group at 2, 3, and 4 years of follow-up (9.3% vs. 6.6%; 8.4% vs. 1.4%; 8.4% vs. 0.0%, respectively). Analysis of patients who received at least one treatment course demonstrated a survival benefit for TTF patients compared to BPC patients (median OS, 7.8 vs. 6.0 months; n ¼ 93 vs. n ¼ 117; p ¼ 0.012; HR ¼ 0.69). In this group, 1-year survival was 28% vs. 20%, and PFS6 was 26.2% vs. 15.2% (p ¼ 0.034). TTF, a noninvasive, novel cancer treatment modality shows significant therapeutic efficacy with promising long-term survival results. The impact of TTF was more pronounced when comparing only patients who received the minimal treatment course. A large-scale phase III trial in newly diagnosed GBM is ongoing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Idiopathic premature ventricular complexes originating from the ventricular outflow tract: evaluation, prognosis and management The prognosis of ventricular premature complexes (VPC) in the absence of heart disease is considered benign. VPC usually originate from the right or, less commonly, left ventricular outflow tract. QRS complexes therefore usually assume a left bundle branch block and inferior axis morphology. These VPC, particularly if very frequent (> 20,000 per day), may adversely affect left ventricular function and their suppression can restore normal function. Moreover, there is a clinical overlap with arrhythmogenic right ventricular dysplasia and this diagnosis should be considered when facing a left bundle branch block shaped VPC. However, the prognosis of outflow tract VPC is good for appropriately selected patients with normal left ventricular function, absence of syncope or ventricular tachycardia, and no evidence of cardiac disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Myocardial tagging has shown to be a useful magnetic resonance modality for the assessment and quantification of local myocardial function. Many myocardial tagging techniques suffer from a rapid fading of the tags, restricting their application mainly to systolic phases of the cardiac cycle. However, left ventricular diastolic dysfunction has been increasingly appreciated as a major cause of heart failure. Subtraction based slice-following CSPAMM myocardial tagging has shown to overcome limitations such as fading of the tags. Remaining impediments to this technique, however, are extensive scanning times (approximately 10 min), the requirement of repeated breath-holds using a coached breathing pattern, and the enhanced sensitivity to artifacts related to poor patient compliance or inconsistent depths of end-expiratory breath-holds. We therefore propose a combination of slice-following CSPAMM myocardial tagging with a segmented EPI imaging sequence. Together with an optimized RF excitation scheme, this enables to acquire as many as 20 systolic and diastolic grid-tagged images per cardiac cycle with a high tagging contrast during a short period of sustained respiration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Digital holographic microscopy (DHM) is a noninvasive optical imaging technique that provides quantitative phase images of living cells. In a recent study, we showed that the quantitative monitoring of the phase signal by DHM was a simple label-free method to study the effects of glutamate on neuronal optical responses (Pavillon et al., 2010). Here, we refine these observations and show that glutamate produces the following three distinct optical responses in mouse primary cortical neurons in culture, predominantly mediated by NMDA receptors: biphasic, reversible decrease (RD) and irreversible decrease (ID) responses. The shape and amplitude of the optical signal were not associated with a particular cellular phenotype but reflected the physiopathological status of neurons linked to the degree of NMDA activity. Thus, the biphasic, RD, and ID responses indicated, respectively, a low-level, a high-level, and an "excitotoxic" level of NMDA activation. Moreover, furosemide and bumetanide, two inhibitors of sodium-coupled and/or potassium-coupled chloride movement strongly modified the phase shift, suggesting an involvement of two neuronal cotransporters, NKCC1 (Na-K-Cl) and KCC2 (K-Cl) in the genesis of the optical signal. This observation is of particular interest since it shows that DHM is the first imaging technique able to monitor dynamically and in situ the activity of these cotransporters during physiological and/or pathological neuronal conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

QUESTION UNDER STUDY: Emergency room (ER) interpretation of the ECG is critical to assessment of patients with acute coronary syndromes (ACS). Our aim was to assess its reliability in our institution, a tertiary teaching hospital. METHODS: Over a 6-month period all consecutive patients admitted for ACS were included in the study. ECG interpretation by emergency physicians (EPs) was recorded on a preformatted sheet and compared with the interpretation of two specialist physicians (SPs). Discrepancies between the 2 specialists were resolved by an ECG specialist. RESULTS: Over the 6-month period, 692 consecutive patients were admitted with suspected ACS. ECG interpretation was available in 641 cases (93%). Concordance between SPs was 87%. Interpretation of normality or abnormality of the ECG was concordant between EPs and SPs in 475 cases (74%, kappa = 0.51). Interpretation of ischaemic modifications was concordant in 69% of cases, and as many ST segment elevations were unrecognised as overdiagnosed (5% each). The same findings occurred for ST segment depressions and negative T waves (12% each). CONCLUSIONS: Interpretation of the ECG recorded during ACS by 2 SPs was discrepant in 13% of cases. Similarly, EP interpretation was discrepant from SP interpretation in 25% of cases, equally distributed between over- and underdiagnosing of ischaemic changes. The clinical implications and impact of medical education on ECG interpretation require further study.