946 resultados para Non invasive methods


Relevância:

90.00% 90.00%

Publicador:

Resumo:

AIMS: Although the coronary artery vessel wall can be imaged non-invasively using magnetic resonance imaging (MRI), the in vivo reproducibility of wall thickness measures has not been previously investigated. Using a refined magnetization preparation scheme, we sought to assess the reproducibility of three-dimensional (3D) free-breathing black-blood coronary MRI in vivo. METHODS AND RESULTS: MRI vessel wall scans parallel to the right coronary artery (RCA) were obtained in 18 healthy individuals (age range 25-43, six women), with no known history of coronary artery disease, using a 3D dual-inversion navigator-gated black-blood spiral imaging sequence. Vessel wall scans were repeated 1 month later in eight subjects. The visible vessel wall segment and the wall thickness were quantitatively assessed using a semi-automatic tool and the intra-observer, inter-observer, and inter-scan reproducibilities were determined. The average imaged length of the RCA vessel wall was 44.5+/-7 mm. The average wall thickness was 1.6+/-0.2 mm. There was a highly significant intra-observer (r=0.97), inter-observer (r=0.94), and inter-scan (r=0.90) correlation for wall thickness (all P<0.001). There was also a significant agreement for intra-observer, inter-observer, and inter-scan measurements on Bland-Altman analysis. The intra-class correlation coefficients for intra-observer (r=0.97), inter-observer (r=0.92), and inter-scan (r=0.86) analyses were also excellent. CONCLUSION: The use of black-blood free-breathing 3D MRI in conjunction with semi-automated analysis software allows for reproducible measurements of right coronary arterial vessel-wall thickness. This technique may be well-suited for non-invasive longitudinal studies of coronary atherosclerosis.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Pioglitazone, an oral anti-diabetic that stimulates the PPAR-gamma transcription factor, increased survival of mice with amyotrophic lateral sclerosis (ALS). METHODS/PRINCIPAL FINDINGS: We performed a phase II, double blind, multicentre, placebo controlled trial of pioglitazone in ALS patients under riluzole. 219 patients were randomly assigned to receive 45 mg/day of pioglitazone or placebo (one: one allocation ratio). The primary endpoint was survival. Secondary endpoints included incidence of non-invasive ventilation and tracheotomy, and slopes of ALS-FRS, slow vital capacity, and quality of life as assessed using EUROQoL EQ-5D. The study was conducted under a two-stage group sequential test, allowing to stop for futility or superiority after interim analysis. Shortly after interim analysis, 30 patients under pioglitazone and 24 patients under placebo had died. The trial was stopped for futility; the hazard ratio for primary endpoint was 1.21 (95% CI: 0.71-2.07, p = 0.48). Secondary endpoints were not modified by pioglitazone treatment. Pioglitazone was well tolerated. CONCLUSION/SIGNIFICANCE: Pioglitazone has no beneficial effects on the survival of ALS patients as add-on therapy to riluzole. TRIAL REGISTRATION: Clinicaltrials.gov NCT00690118.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Non-invasive visualization of the coronary arteries represents a major challenge in modern cardiology, but this goal may be achieved in the near future by MR angiography. Possible applications are non-invasive diagnosis of coronary artery disease, and follow-up examinations for therapy control after PTCA, in order to detect restenosis at an early stage. A multiple slice technique (2 mm slice thickness, with a spatial resolution of 1 x 1 mm, Philips Gyroscan ACS-II, 1.5 Tesla) was used. Ten volunteers were imaged and 10 patients with coronary artery disease were examined before and after PTCA. MR measurements were validated by quantitative coronary angiography. The diameters of the proximal coronary arteries as measured by both methods were compared, and a good correlation was found (r = 0.76). Thus, it is concluded that non-invasive visualization of the coronary arteries is possible before and after PTCA and allows to determine potential restenoses. However, patient cooperation is essential for good image quality. Moreover, limited spatial image resolution and breathing artifacts restrict MR coronary angiography today to be used as a routine diagnostic tool for the diagnosis of coronary artery disease.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Sophisticated magnetic resonance tagging techniques provide powerful tools for the non-invasive assessment of the local heartwall motion towards a deeper fundamental understanding of local heart function. For the extraction of motion data from the time series of magnetic resonance tagged images and for the visualization of the local heartwall motion a new image analysis procedure has been developed. New parameters have been derived which allows quantification of the motion patterns and are highly sensitive to any changes in these patterns. The new procedure has been applied for heart motion analysis in healthy volunteers and in patient collectives with different heart diseases. The achieved results are summarized and discussed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Aim: Gamma Knife surgery (GKS) is a non-invasive neurosurgical stereotactic procedure, increasingly used as an alternative to open functional procedures. This includes the targeting of the ventro-intermediate (Vim) nucleus of the thalamus for tremor. We currently perform an indirect targeting, using the "quadrilatere of Guyot," as the Vim nucleus is not visible on current 3 Tesla (T) MRI acquisitions. The primary objective of the current study was to enhance anatomic imaging for Vim GKS using high-field (7 T) MRI, with the aim of refining the visualization and precision of anatomical targeting. Method: Five young healthy subjects (mean age 23 years) were scanned both on 3 and 7 T MRI in Lausanne University Hospital (CHUV) and Center for Biomedical Imaging (CIBM). Classical T1-weighted MPRAGE, T2 CISS sequences (replacing former ventriculography) and diffusion tensor imaging were acquired at 3T. We obtained high-resolution susceptibility weighted images (SWI) at 7T for the visualization of thalamic subparts. SWI was further integrated for the first time into Leksell Gamma Plan® (LGP) software and co-registered with the 3T images. A simulation of targeting of the Vim was done using the "quadrilatere of Guyot" methodology on the 3T images. Furthermore, a correlation with the position of the found target on SWI was performed. The atlas of Morel et al. was used to confirm the findings on a detailed computer analysis outside LGP. Also, 3T and 7T MRI of one patient undergoing GKS Vim thalamotomy, were obtained before and 2 years after the procedure, and studied similarly. Results: The use of SWI provided a superior resolution and improved image contrast within the central gray matter. This allowed visualization and direct delineation of groups of thalamic nuclei in vivo, including the Vim. The position of the target, as assessed with the "quadrilatere of Guyot" method on 3 T, perfectly matched with the supposed one of the Vim on the SWI. Furthermore, a 3-dimensional model of the Vim target area was created on the basis of 3T and 7T images. Conclusion: This is the first report of the integration of SWI high-field MRI into the LGP in healthy subjects and in one patient treated GKS Vim thalamotomy. This approach aims at the improvement of targeting validation and further direct targeting of the Vim in tremor. The anatomical correlation between the direct visualization on 7T and the current targeting methods on 3T seems to show a very good anatomical matching.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pendant la grossesse, la pression artérielle reste stable malgré une nette augmentation du volume d'éjection systolique et du débit cardiaque. Cette stabilité vient d'un côté d'une vasodilatation périphérique entraînant une diminution des résistances périphériques et d'un autre côté d'une moindre rigidité des principales artères notamment l'aorte. En conséquence, l'amplitude des ondes de pouls est atténuée, de même que leur vitesse de propagation dans le sens tant antérogade que rétrograde (ondes réfléchies). Les ondes réfléchies tendent ainsi à atteindre l'aorte ascendante plus tard durant la systole, voire durant la diastole, ce qui peut contribuer à diminuer la pression puisée. La prééclampsie perturbe massivement ce processus d'adaptation. Il s'agit d'une maladie hypertensive de la grossesse engendrant une importante morbidité et mortalité néonatale et maternelle. Il est à remarquer que la diminution de la rigidité artérielle n'est pas observée chez les patientes atteintes avec pour conséquence une forte augmentation de la pression systolique centrale (aortique) par les ondes réfléchies. Ce fait a été établi grâce à l'existence de la tonométrie d'aplanation, une méthode permettant l'évaluation non invasive de l'onde de pouls centrale. Dans cette méthode, un senseur de pression piézo-électrique permet de capter l'onde de pouls périphérique, le plus souvent sur l'artère radiale. Par la suite, un algorithme validé permet d'en déduire la forme de l'onde de pouls centrale et de visualiser à quel moment du cycle cardiaque s'y ajoutent les ondes réfléchies. Plusieurs études font état d'une forte augmentation de la pression systolique centrale par les ondes réfléchies chez les patientes atteintes de prééclampsie, suggérant l'utilisation de cette méthode pour le diagnostic et le monitoring voire pour le dépistage de ces patientes. Pour atteindre ce but, il est nécessaire d'établir des normes en rapport notamment avec l'âge gestationnel. Dans la littérature, les données pertinentes actuellement disponibles sont variables, voire contradictoires. Par exemple, les ondes réfléchies proéminentes dans la partie diastolique de l'onde de pouls centrale disparaissaient chez des patientes enceintes au 3eme trimestre comparées à des contrôles non enceintes dans une étude lausannoise, alors que deux autres études présentent l'observation contraire. Autre exemple, certains auteurs décrivent une diminution progressive de l'augmentation systolique jusqu'à l'accouchement alors que d'autres rapportent un nadir aux environs du 6ème mois, suivi d'un retour à des valeurs plus élevées en fin de grossesse. Les mesures effectuées dans toutes ces études différaient dans leur exécution, les patientes étant notamment dans des postions corporelles différentes (couchées, semi-couchées, assises, en décubitus latéral). Or nous savons que le status hémodynamique est très sensible aux changements de position, particulièrement durant la grossesse où l'utérus gravide est susceptible d'avoir des interactions mécaniques avec les veines et possiblement les artères abdominales. Ces différences méthodologiques pourraient donc expliquer, au moins en partie, l'hétérogénéité des résultats concernant l'onde de pouls chez la femme enceinte, ce qui à notre connaissance n'a jamais été exploré. Nous avons mesuré l'onde de pouls dans les positions assise et couchée chez des femmes enceintes, au 3eme trimestre d'une grossesse non compliquée, et nous avons effectué une comparaison avec des données similaire obtenues chez des femmes non enceintes en bonne santé habituelle. Les résultats montrent que la position du corps a un impact majeur sur la forme de l'onde de pouls centrale. Comparée à la position assise, la position couchée se caractérise par une moindre augmentation systolique et, par contraste, une augmentation diastolique plus marquée. De manière inattendue, cet effet s'observe aussi bien en présence qu'en l'absence de grossesse, suggérant que la cause première n'en réside pas dans les interactions mécaniques de l'utérus gravide avec les vaisseaux sanguins abdominaux. Nos observations pourraient par contre être expliquées par l'influence de la position du corps, via un phénomène hydrostatique simple, sur la pression transmurale des artères éloignées du coeur, tout particulièrement celles des membres inférieurs et de l'étage abdominal. En position verticale, ces vaisseaux augmenteraient leur rigidité pour résister à la distension de leur paroi, ce qui y accroîtrait la vitesse de propagation des ondes de pression. En l'état, cette explication reste hypothétique. Mais quoi qu'il en soit, nos résultats expliquent certaines discordances entre les études conduites à ce jour pour caractériser l'influence de la grossesse physiologique sur la forme de l'onde de pouls central. De plus, ils indiquent que la position du corps doit être prise en compte lors de toute investigation utilisant la tonométrie d'applanation pour déterminer la rigidité des artères chez les jeunes femmes enceintes ou non. Il sera aussi nécessaire d'en tenir compte pour établir des normes en vue d'une utilisation de la tonométrie d'aplanation pour dépister ou suivre les patientes atteintes de prééclampsie. Il serait enfin intéressant d'évaluer si l'effet de la position sur la forme de l'onde de pouls central existe également dans l'autre sexe et chez des personnes plus âgées.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this study was to compare our experience with minimally invasive transforaminal lumbar interbody fusion (MITLIF) and open midline transforaminal lumbar interbody fusion (TLIF). A total of 36 patients suffering from isthmic spondylolisthesis or degenerative disc disease were operated with either a MITLIF (n = 18) or an open TLIF technique (n = 18) with an average follow-up of 22 and 24 months, respectively. Clinical outcome was assessed using the visual analogue scale (VAS) and the Oswestry disability index (ODI). There was no difference in length of surgery between the two groups. The MITLIF group resulted in a significant reduction of blood loss and had a shorter length of hospital stay. No difference was observed in postoperative pain, initial analgesia consumption, VAS or ODI between the groups. Three pseudarthroses were observed in the MITLIF group although this was not statistically significant. A steeper learning effect was observed for the MITLIF group.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We conducted a molecular study of MRSA isolated in Swiss hospitals, including the first five consecutive isolates recovered from blood cultures and the first ten isolates recovered from other sites in newly identified carriers. Among 73 MRSA isolates, 44 different double locus sequence typing (DLST) types and 32 spa types were observed. Most isolates belonged to the NewYork/Japan, the UK-EMRSA-15, the South German and the Berlin clones. In a country with a low to moderate MRSA incidence, inclusion of non-invasive isolates allowed a more accurate description of the diversity.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Nonalcoholic fatty liver disease (NAFLD) clusters in families, but the only known common genetic variants influencing risk are near PNPLA3. We sought to identify additional genetic variants influencing NAFLD using genome-wide association (GWA) analysis of computed tomography (CT) measured hepatic steatosis, a non-invasive measure of NAFLD, in large population based samples. Using variance components methods, we show that CT hepatic steatosis is heritable (∼26%-27%) in family-based Amish, Family Heart, and Framingham Heart Studies (n = 880 to 3,070). By carrying out a fixed-effects meta-analysis of genome-wide association (GWA) results between CT hepatic steatosis and ∼2.4 million imputed or genotyped SNPs in 7,176 individuals from the Old Order Amish, Age, Gene/Environment Susceptibility-Reykjavik study (AGES), Family Heart, and Framingham Heart Studies, we identify variants associated at genome-wide significant levels (p<5×10(-8)) in or near PNPLA3, NCAN, and PPP1R3B. We genotype these and 42 other top CT hepatic steatosis-associated SNPs in 592 subjects with biopsy-proven NAFLD from the NASH Clinical Research Network (NASH CRN). In comparisons with 1,405 healthy controls from the Myocardial Genetics Consortium (MIGen), we observe significant associations with histologic NAFLD at variants in or near NCAN, GCKR, LYPLAL1, and PNPLA3, but not PPP1R3B. Variants at these five loci exhibit distinct patterns of association with serum lipids, as well as glycemic and anthropometric traits. We identify common genetic variants influencing CT-assessed steatosis and risk of NAFLD. Hepatic steatosis associated variants are not uniformly associated with NASH/fibrosis or result in abnormalities in serum lipids or glycemic and anthropometric traits, suggesting genetic heterogeneity in the pathways influencing these traits.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction: Smuggling dissolved drugs, especially cocaine, in bottled liquids is a problem at borders nowadays. Common fluoroscopy of packages at the border cannot detect contaminated liquids. To find a dissolved drug, an immunological test using a drug-test panel has to be performed. This means that a control sample of the cargo must be opened to perform the test. As it is not possible to open all boxes, and as smugglers hide the drugcontaining boxes between regularly filled boxes, contaminated cargos can be overlooked. Investigators sometimes cannot perform the drug-test panel because they try not to arouse the smugglers' suspicion in order to follow the cargo and to find the recipient. Aims: The objective of our studies was to define non-invasive examination techniques to investigate cargos that are suspicions to contain dissolved cocaine without leaving traces on the samples. We examined vessels containing cocaine by radiological cross-section techniques such as multidetector computed tomography (MDCT) and magnetic resonance spectroscopy (MRS). Methods: In a previous study, we examined bottles of wine containing dissolved cocaine in different quantities using an MDCT unit. To distinguish between bottles containing red wine and those where cocaine was solved in the wine, cross sectional 2D-images have been reconstructed and the absorption of X-rays was quantified by measuring the mean density of the liquid inside the bottles. In our new study, we investigated phantoms containing cocaine dissolved in water with or without ethanol as well as cocaine dissolved in different sorts of commercially available wine by the use of a clinical magnetic resonance unit (3 tesla). To find out if dissolved cocaine could be detected, magnetic resonance spectroscopy (1H MRS) was performed. Results: By using a MDCT-unit and measuring the mean attenuation of X-rays, it is possible to distinguish weather substances are dissolved in a liquid or not, if a comparative liquid without any solutions is available. The increase of the mean density indicates the presence of dissolved substances without the possibility to identify the substance. By using magnetic resonance spectroscopy, dissolved cocaine can be clearly identified because it produces distinctive resonances in the spectrum. In contrast to MDCT, this technique shows a high sensitivity (detection of 1 mM cocaine in wine). Conclusions: Cross-sectional imaging techniques such as MDCT and MRS appropriated to examine cargos that are suspicious to contain dissolved cocaine. They allow to perform non-invasive investigations without leaving any trace on the cargo. While an MDCT scan can detect dissolved substances in liquids, identification of cocaine can be obtained by MR-spectroscopy. Acknowledgment: This work was supported by the Centre d'Imagerie BioMédicale (CIBM) of the University of Lausanne (UNIL), the Swiss Federal Institute of Technology Lausanne (EPFL), the University of Geneva (UniGe), the Centre Hospitalier Universitaire Vaudois (CHUV), the Hôpitaux Universitaire de Genève (HUG) and the Leenaards and the Jeantet Foundations.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

INTRODUCTION. A two-step assessment (readiness to wean (RW) followed by spontaneousbreathing trial (SBT)) of predefined criteria is recommended before planned extubation(PE)1.OBJECTIVES. We aimed to evaluate if compliance to all guideline criteria was associatedwith better respiratory outcome within 48 h after PE.METHODS. The data (extracted from our clinical information system) of 458 consecutivepatients who underwent PE after C48 h of invasive ventilation in our medico-surgical ICUwere analyzed. We evaluated compliance with guidelines [1] regarding respiratory rate, tidalvolume, PaO2, FiO2, PEEP, PaCO2, pH, heart rate, systolic arterial pressure and arrhythmiaduringRWand SBT assessment (RW and SBT within 2 h). A patient was classified as RW+ ifallRWcriteria were fulfilled andRW-if at least 1 criterion was violated. The same approachwas used to define SBT+ and SBT- patients. During the 48 h following PE, we assessed theoccurrence of post-PE respiratory failure (PRF) (defined as the presence of at least 1 consensuscriterion of respiratory failure [1]), reintubation (after NIV failure or because of immediateintubation criteria) and cumulative duration of post-PE ventilation (PPEV = Post-PE invasive+ non-invasive ventilation). ICU mortality was recorded. Comparisons for variousoutcomes were performed by Chi-square and t tests.RESULTS. All consensus criteria were fulfilled in 77.3% of the patients during RW and in68.1% of the patients during SBT.[Compliance to weaning criteria and outcome]N = 458 PRF (%) Reintubation (%) PPEV (min) ICU mortality (%)All patients 53.5 10.0 542 ± 664 6.1RW+ 50.0 9.3 490 ± 626 5.4RW- 65.4* 12.5 718 ± 757** 8.7SBT+ 52.6 8.0 498 ± 594 6.7SBT- 55.5 14.4*** 637 ± 788**** 4.8Occurrence of PRF only was not associated with increased ICU mortality: 4.2 versus 7.8%,p = 0.11. By contrast, ICU mortality was significantly increased in patients requiring reintubation:21.7 versus 4.4%. p\0.001; * p = 0.006 RW+ versus RW-; ** p = 0.003RW+ versus RW-; *** p = 0.035 SBT+ versus SBT-; **** p = 0.030 SBT+ versusSBTCONCLUSIONS.In our ICU, compliance to all criteria of the two-step published approach ofrespiratory weaning was not optimal but reintubation rate was comparable to published data.Compliance with consensus conference guidelines was associated with lower reintubation rateand shorter PPEV but not with ICU mortality. As mortality was increased by reintubation,more sensitive and specific criteria to predict the risk of reintubation are probably needed.REFERENCE. Boles JM, et al. Eur Respir J 2007;29:1033-56.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: The objective is to develop a cost-effective, reliable and non invasive screening test able to detect early CRCs and adenomas. This is done on a nucleic acids multigene assay performed on peripheral blood mononuclear cells (PBMCs). METHODS: A colonoscopy-controlled study was conducted on 179 subjects. 92 subjects (21 CRC, 30 adenoma >1 cm and 41 controls) were used as training set to generate a signature. Other 48 subjects kept blinded (controls, CRC and polyps) were used as a test set. To determine organ and disease specificity 38 subjects were used: 24 with inflammatory bowel disease (IBD),14 with other cancers (OC). Blood samples were taken and PBMCs were purified. After the RNA extraction, multiplex RT-qPCR was applied on 92 different candidate biomarkers. After different univariate and multivariate analysis 60 biomarkers with significant p-values (<0.01) were selected. 2 distinct biomarker signatures are used to separate patients without lesion from those with CRC or with adenoma, named COLOX CRC and COLOX POL. COLOX performances were validated using random resampling method, bootstrap. RESULTS: COLOX CRC and POL tests successfully separate patients without lesions from those with CRC (Se 67%, Sp 93%, AUC 0.87), and from those with adenoma > 1cm (Se 63%, Sp 83%, AUC 0.77). 6/24 patients in the IBD group and 1/14 patients in the OC group have a positive COLOX CRC. CONCLUSION: The two COLOX tests demonstrated a high Se and Sp to detect the presence of CRCs and adenomas > 1 cm. A prospective, multicenter, pivotal study is underway in order to confirm these promising results in a larger cohort.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We present a new lab-on-a-chip system for electrophysiological measurements on Xenopus oocytes. Xenopus oocytes are widely used host cells in the field of pharmacological studies and drug development. We developed a novel non-invasive technique using immobilized non-devitellinized cells that replaces the traditional "two-electrode voltage-clamp" (TEVC) method. In particular, rapid fluidic exchange was implemented on-chip to allow recording of fast kinetic events of exogenous ion channels expressed in the cell membrane. Reducing fluidic exchange times of extracellular reagent solutions is a great challenge with these large millimetre-sized cells. Fluidic switching is obtained by shifting the laminar flow interface in a perfusion channel under the cell by means of integrated poly-dimethylsiloxane (PDMS) microvalves. Reagent solution exchange times down to 20 ms have been achieved. An on-chip purging system allows to perform complex pharmacological protocols, making the system suitable for screening of ion channel ligand libraries. The performance of the integrated rapid fluidic exchange system was demonstrated by investigating the self-inhibition of human epithelial sodium channels (ENaC). Our results show that the response time of this ion channel to a specific reactant is about an order of magnitude faster than could be estimated with the traditional TEVC technique.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Postoperative care of major neurosurgical procedures is aimed at the prevention, detection and treatment of secondary brain injury. This consists of a series of pathological events (i.e. brain edema and intracranial hypertension, cerebral hypoxia/ischemia, brain energy dysfunction, non-convulsive seizures) that occur early after the initial insult and surgical intervention and may add further burden to primary brain injury and thus impact functional recovery. Management of secondary brain injury requires specialized neuroscience intensive care units (ICU) and continuous advanced monitoring of brain physiology. Monitoring of intracranial pressure (ICP) is a mainstay of care and is recommended by international guidelines. However, ICP monitoring alone may be insufficient to detect all episodes of secondary brain insults. Additional invasive (i.e. brain tissue PO2, cerebral microdialysis, regional cerebral blood flow) and non-invasive (i.e. transcranial doppler, near-infrared spectroscopy, EEG) brain monitoring devices might complement ICP monitoring and help clinicians to target therapeutic interventions (e.g. management of cerebral perfusion pressure, blood transfusion, glucose control) to patient-specific pathophysiology. Several independent studies demonstrate such multimodal approach may optimize patient care after major neurosurgical procedures. The aim of this review is to evaluate some of the available monitoring systems and summarize recent important data showing the clinical utility of multimodal neuromonitoring for the management of main acute neurosurgical conditions, including traumatic brain injury, subarachnoid hemorrhage and stroke.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

AIMS: The time course of atherosclerosis burden in distinct vascular territories remains poorly understood. We longitudinally evaluated the natural history of atherosclerotic progression in two different arterial territories using high spatial resolution magnetic resonance imaging (HR-MRI), a powerful, safe, and non-invasive tool. METHODS AND RESULTS: We prospectively studied a cohort of 30 patients (mean age 68.3, n = 9 females) with high Framingham general cardiovascular disease 10-year risk score (29.5%) and standard medical therapy with mild-to-moderate atherosclerosis intra-individually at the level of both carotid and femoral arteries. A total of 178 HR-MRI studies of carotid and femoral arteries performed at baseline and at 1- and 2-year follow-up were evaluated in consensus reading by two experienced readers for lumen area (LA), total vessel area (TVA), vessel wall area (VWA = TVA - LA), and normalized wall area index (NWI = VWA/TVA). At the carotid level, LA decreased (-3.19%/year, P = 0.018), VWA increased (+3.83%/year, P = 0.019), and TVA remained unchanged. At the femoral level, LA remained unchanged, VWA and TVA increased (+5.23%/year and +3.11%/year, both P < 0.01), and NWI increased for both carotid and femoral arteries (+2.28%/year, P = 0.01, and +1.8%/year, P = 0.033). CONCLUSION: The atherosclerotic burden increased significantly in both carotid and femoral arteries. However, carotid plaque progression was associated with negative remodelling, whereas the increase in femoral plaque burden was compensated by positive remodelling. This finding could be related to anatomic and flow differences and/or to the distinct degree of obstruction in the two arterial territories.