994 resultados para Nasal prostheses
Resumo:
Alzheimer's disease (AD) is a fatal neurodegenerative condition characterized clinically by progressive memory loss and irreversible cognitive deterioration. It has been shown that there is a progressive degeneration of the brain cholinergic neurons which leads to the appearance of cognitive symptoms of the disease. The aim of this work was the formulation of multifunctional nanocarriers for nasal administration of tacrine-HCl (THA). This route has many advantages; in particular is possible to convey the drug directly to the Central Nervous System, through the olfactory bulb. In particular, were prepared Albumin nanoparticles carrying beta cyclodextrin and two different beta cyclodextrin derivatives (hydroxypropyl beta cyclodextrin and sulphobutylether beta cyclodextrin), and Multifunctional liposomes, prepared using traditional excipients (cholesterol and phosphatidylcholine), partly enriched with α-tocopherol (Toc) and/or polyunsaturated fatty acids (eicosapentaenoic acid and docosahexaenoic acid) (Ω3). Both nanosystems were characterized in terms of size, Zeta potential and encapsulation efficiency. Were also evaluated their functional properties such as mucoadhesion and permeability, using an ex-vivo assay based on nasal sheep mucosa. On Liposomes were also assessed drug neuronal uptake, cell toxicity, antioxidant and, cytoprotective activity in the human neuronal cell line SH-SY5Y and finally tocopherol trans-membrane diffusion. Both the nanocarriers produced presented excellent properties and a high potential as new systems for CNS-delivery of anti-Alzheimer drugs via the nasal route.
Resumo:
In the last years the number of shoulder arthroplasties has been increasing. Simultaneously the study of their shape, size and strength and the reasons that bring to a possible early explantation have not yet been examined in detail. The research carried out directly on explants is practically nonexistent, this means a poor understanding of the mechanisms leading the patient and so the surgeon, to their removal. The analysis of the mechanisms which are the cause of instability, dislocation, broken, fracture, etc, may lead to a change in the structure or design of the shoulder prostheses and lengthen the life of the implant in situ. The idea was to analyze 22 explants through three methods in order to find roughness, corrosion and surface wear. In the first method, the humeral heads and/or the glenospheres were examined with the interferometer, a machine that through electromagnetic waves gives information about the roughness of the surfaces under examination. The output of the device was a total profile containing both roughness and information on the waves (representing the spatial waves most characteristic on the surface). The most important value is called "roughness average" and brings the average value of the peaks found in the local defects of the surfaces. It was found that 42% of the prostheses had considerable peak values in the area where the damage was caused by the implant and not only by external events, such as possibly the surgeon's hand. One of the problems of interest in the use of metallic biomaterials is their resistance to corrosion. The clinical significance of the degradation of metal implants has been the purpose of the second method; the interaction between human body and metal components is critical to understand how and why they arrive to corrosion. The percentage of damage in the joints of the prosthetic components has been calculated via high resolution photos and the software ImageJ. The 40% and 50% of the area appeared to have scratches or multiple lines due to mechanical artifacts. The third method of analysis has been made through the use of electron microscopy to quantify the wear surface in polyethylene components. Different joint movements correspond to different mechanisms of damage, which were imprinted in the parts of polyethylene examined. The most affected area was located mainly in the side edges. The results could help the manufacturers to modify the design of the prostheses and thus reduce the number of explants. It could also help surgeons in choosing the model of the prosthesis to be implanted in the patient.
Resumo:
Nasal carriage of Staphylococcus aureus contributes to an increased risk of developing an infection with the same bacterial strain. Genetic regulatory elements and toxin-expressing genes are virulence factors associated with the pathogenic potential of S. aureus. We undertook an extensive molecular characterization of methicillin-susceptible S. aureus (MSSA) carried by children. MSSA were recovered from the nostrils of children. The presence of Panton-Valentine leukocidin (PVL), exfoliatins A and B (exfoA and exfoB), and the toxic-shock staphylococcal toxin (TSST-1) and agr group typing were determined by quantitative PCR. A multiple-locus variable-number of tandem repeat analysis (MLVA) assay was also performed for genotyping. Five hundred and seventy-two strains of MSSA were analysed. Overall, 30% were positive for toxin-expressing genes: 29% contained one toxin and 1.6% two toxins. The most commonly detected toxin gene was tst, which was present in 145 (25%) strains. The TSST-1 gene was significantly associated with the agr group 3 (OR 56.8, 95% CI 32.0-100.8). MLVA analysis revealed a large diversity of genetic content and no clonal relationship was demonstrated among the analysed MSSA strains. Multilocus sequence typing confirmed this observation of diversity and identified ST45 as a frequent colonizer. This broad diversity in MSSA carriage strains suggests a limited selection pressure in our geographical area.
Resumo:
Prospective multicenter observational case-series.
Resumo:
The SWISSspine registry is the first mandatory registry of its kind in the history of Swiss orthopaedics and it follows the principle of "coverage with evidence development". Its goal is the generation of evidence for a decision by the Swiss federal office of health about reimbursement of the concerned technologies and treatments by the basic health insurance of Switzerland. Recently, developed and clinically implemented, the Dynardi total disc arthroplasty (TDA) accounted for 10% of the implanted lumbar TDAs in the registry. We compared the outcomes of patients treated with Dynardi to those of the recipients of the other TDAs in the registry. Between March 2005 and October 2009, 483 patients with single-level TDA were documented in the registry. The 52 patients with a single Dynardi lumbar disc prosthesis implanted by two surgeons (CE and OS) were compared to the 431 patients who received one of the other prostheses. Data were collected in a prospective, observational multicenter mode. Surgery, implant, 3-month, 1-year, and 2-year follow-up forms as well as comorbidity, NASS and EQ-5D questionnaires were collected. For statistical analyses, the Wilcoxon signed-rank test and chi-square test were used. Multivariate regression analyses were also performed. Significant and clinically relevant reduction of low back pain and leg pain as well as improvement in quality of life was seen in both groups (P < 0.001 postop vs. preop). There were no inter-group differences regarding postoperative pain levels, intraoperative and follow-up complications or revision procedures with a new hospitalization. However, significantly more Dynardi patients achieved a minimum clinically relevant low back pain alleviation of 18 VAS points and a quality of life improvement of 0.25 EQ-5D points. The patients with Dynardi prosthesis showed a similar outcome to patients receiving the other TDAs in terms of postoperative low back and leg pain, complications, and revision procedures. A higher likelihood for achieving a minimum clinically relevant improvement of low back pain and quality of life in Dynardi patients was observed. This difference might be due to the large number of surgeons using other TDAs compared to only two surgeons using the Dynardi TDA, with corresponding variations in patient selection, patient-physician interaction and other factors, which cannot be assessed in a registry study.
Resumo:
We report a series of 16 consecutive total knee arthroplasty (TKA) revision procedures for deep infection, treated with a newly developed intraoperatively moulded PMMA cement-prostheses-like spacer (CPLS). The standard treatment consisted of a two-stage protocol with initial explantation of the infected components combined with radical debridement, followed by implantation of a temporary cement spacer and final reimplantation of a new TKA. A sterilizeable Teflon tapered aluminium mould was developed for production of a custom made CPLS during the intervention. Stable implantation of the CPLS was achieved with a second cementation, allowing for correct alignment and ligament balancing. The spacer remained 3.5 months on average until reimplantation of a TKA occurred. At time of reimplantation, patients had an average KSS score of 84.44 points with an average flexion capacity of 102°. There was no recurrent infection during the study period of minimum 2 years. With this new technique, a low friction articulation with good stability, high comfort and a better range of motion compared to handcrafted spacers was achieved. The use of this spacer is a time sparing, cheap and convenient option in 2-stage TKA revision.
Resumo:
This study sought to assess post-procedural and mid-term outcome of patients, in which a second "in-series" CoreValve prosthesis (Medtronic, Minneapolis, Minnesota) was implanted during the same procedure.
Resumo:
Background: After oral tumor resection, structural and functional rehabilitation by means of dental prostheses is complex, and positive treatment outcome is not always predictable. Purpose: The objective of the study was to report on oral rehabilitation and quality of life 2-5 years after resection of malignant oral tumors. Materials and Methods: Data of 46 patients (57 ± 7 years) who underwent oral tumor surgery were available. More than 50% of tumors were classified T3 or T4. Open oro-nasal defects resulted in 12 patients and full mandibulary block resections in 23 patients. Comprehensive planning, implant placement, and prosthetic rehabilitation followed an interdisciplinary protocol. Analysis comprised tumor location, type of prostheses, implant survival, and quality of life. Results: Because of advanced tumor status, resections resulted in marked alteration of the oral anatomy requiring complex treatment procedures. Prosthetic rehabilitation comprised fixed and removable prostheses, with 104 implants placed in 28 patients (60%). Early implant loss was high (13%) and cumulative survival rate of loaded implants was <90% after 5 years. Prosthetic plans had to be modified because of side effects of tumor therapy, complications with implants and tumor recurrence. The majority of patients rated quality of life favorable, but some experienced impaired swallowing, dry mouth, limited mouth opening, appearance, and soreness. Conclusions: Some local effects of tumor therapy could not be significantly improved by prosthetic rehabilitation leading to functional and emotional disability. Many patients had passed away or felt too ill to fill the questionnaires. This case series confirms the complex anatomic alterations after tumor resection and the need for individual treatment approaches especially regarding prosthesis design. In spite of disease-related local and general restrictions, most patients gave a positive assessment of quality of life.
Resumo:
The nasopalatine duct cyst (NPDC) is the most frequent nonodontogenic cyst of the jaws and can be misinterpreted as an apical lesion of endodontic origin.
Resumo:
Objectives: To evaluate the biological and technical complication rates of fixed dental prostheses (FDP) with end abutments or cantilever extensions on teeth (FDP-tt/cFDP-tt) on implants (FDP-ii/cFDP-ii) and tooth-implant-supported (FDP-ti/cFDP-ti) in patients treated for chronic periodontitis. Material and methods: From a cohort of 392 patients treated between 1978 and 2002 by graduate students, 199 were re-examined in 2005. Of these, 84 patients had received ceramo-metal FDPs (six groups). Results: At the re-evaluation, the mean age of the patients was 62 years (36.2–83.4). One hundred and seventy-five FDPs were seated (82 FDP-tt, 9 FDP-ii, 20 FDP-ti, 39 cFDP-tt, 15 cFDP-ii, 10 cFDP-ti). The mean observation time was 11.3 years; 21 FDPs were lost, and 46 technical and 50 biological complications occurred. Chances for the survival of the three groups of FDPs with end abutments were very high (risk for failure 2.8%, 0%, 5.6%). The probability to remain without complications and/or failure was 70.3%, 88.9% and 74.7% in FDPs with end abutments, but 49.8–25% only in FDPs with extensions at 10 years. Conclusions: In patients treated for chronic periodontitis and provided with ceramo-metal FDPs, high survival rates, especially for FDPs with end abutments, can be expected. The incidence rates of any negative events were increased drastically in the three groups with extension cFDPs (tt, ii, ti). Strategic decisions in the choice of a particular FDP design and the choice of teeth/implants as abutments appear to influence the risks for complications to be expected with fixed reconstruction. If possible, extensions on tooth abutments should be avoided or used only after a cautious clinical evaluation of all options.
Resumo:
To analyze maintenance service of fixed maxillary prostheses and overdentures based on conventional gold bars or titanium bars and frameworks fabricated with computer-aided design/computer-assisted manufacture (CAD/CAM) technology.
Resumo:
Excessive cantilever lengths of fixed implant-supported prostheses may have functional and biomechanical disadvantages. This study reports the clinical outcomes of unconventional implants placed for distal support of a fixed implant-supported prostheses. Seven extraoral implants with intraosseous lengths of 2.5 to 4.0 mm were placed in four patients. Distal cantilevers had a mean length of 29.8 mm (range, 18.6 to 39.3 mm). No bone loss or other adverse events were found. The prosthetic plan was maintained in all patients. Within the limits of the employed research design, this concept seems to be a successful option for fixed complete implant-supported prosthesis treatment.
Resumo:
Aortic valve replacement using a tissue valve is controversial for patients younger than 60 years old. The long-term survival in this age group, the expected event rates during long-term follow-up, and valve-related complications are not clearly determined.