893 resultados para Musculoskeletal ultrasound


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Arthropathy that mimics osteoarthritis (OA) and osteoporosis (OP) is considered a complication of hereditary hemochromatosis (HH). We have limited data comparing OA and OP prevalence among HH patients with different hemochromatosis type 1 (HFE) genotypes. We investigated the prevalence of OA and OP in patients with HH by C282Y homozygosity and compound heterozygosity (C282Y/H63D) genotype. METHODS: A total of 306 patients with HH completed a questionnaire. Clinical and demographic characteristics and presence of OA, OP and related complications were compared by genotype, adjusting for age, sex, body mass index (BMI), current smoking and menopausal status. RESULTS: In total, 266 of the 306 patients (87%) were homozygous for C282Y, and 40 (13%) were compound heterozygous. The 2 groups did not differ by median age [60 (interquartile range [IQR] 53 to 68) vs. 61 (55 to 67) years, P=0.8], sex (female: 48.8% vs. 37.5%, P=0.18) or current smoking habits (12.4% vs. 10%, P=0.3). As compared with compound heterozygous patients, C282Y homozygous patients had higher median serum ferritin concentration at diagnosis [1090 (IQR 610 to 2210) vs. 603 (362 to 950) µg/L, P<0.001], higher median transferrin saturation [80% (IQR 66 to 91%) vs. 63% (55 to 72%), P<0.001]) and lower median BMI [24.8 (22.1 to 26.9) vs. 26.2 (23.5 to 30.3) kg/m2, P<0.003]. The overall prevalence of self-reported OA was significantly higher with C282Y homozygosity than compound heterozygosity (53.4% vs. 32.5%; adjusted odds ratio [aOR] 2.4 [95% confidence interval 1.2-5.0]), as was self-reported OP (25.6% vs. 7.5%; aOR 3.5 [1.1-12.1]). CONCLUSION: Patients with C282Y homozygosity may be at increased risk of musculoskeletal complications of HH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: Enthesitis is the hallmark of spondyloarthritis (SpA), and is observed in all subtypes. Wide information on SpA abnormalities, including synovitis, tendinitis and enthesitis, can be efficiently perceived by Doppler ultrasound. Furthermore, several studies on imaging of enthesis showed that imaging techniques are better than clinical examination to detect enthesis alterations; and vascularized enthesitis detected by Doppler ultrasound appears to be a valuable diagnostic tool to confirm SpA diagnosis. However, data published until now concerning entheseal elementary alterations that characterize SpA enthesitis (enthesis inflammatory activity) or enthesopathy (permanent structural changes) reflect rather the authors’ empiric opinion than a methodological validation process. In this sense it seems crucial to identify elementary entheseal lesions associated with activity or damage, in order to improve monitoring and treatment response in SpA patients. The development of better assessment tools is today a challenge and a need in SpA. The first study of this thesis focused on the analysis of the reliability of inter-lector and inter-ultrasonography equipment of Madrid sonography enthesitis index (MASEI). Fundamental data for the remaining unrolling project validity. In the second and third studies we concerned about two entheseal elemental lesions: erosions and bursa. In literature erosions represent a permanent structural damage, being useful for monitoring joint injury, disease activity and therapeutic response in many rheumatic diseases; and to date, this concept has been mostly applied in rheumatoid arthritis (RA). Unquestionably, erosion is a tissue-related damage and a structural change. However, the hypothesis that we decided to test was if erosions represent a permanent structural change that can only grow and worsen over time, as occurs in RA, or a transitory alteration. A longitudinal study of early SpA patients was undertaken, and the Achilles enthesis was used as a model. Our results strongly suggested that previously detected erosions could disappear during the course of the disease, being consistent with the dynamic behavior of erosion over time. Based on these striking results it seems reasonable to suggest that the new-bone formation process in SpA could be associated with the resolution of cortical entheseal erosion over time. These results could also be in agreement with the apparent failure of anti-tumor necrosis factor (TNF) therapies to control bone proliferation in SpA; and with the relation of TNF-α, Dickkopf-related protein 1 (Dkk-1) and the regulatory molecule of the Wnt signaling pathway in the bone proliferation in SpA. In the same model, we then proceeded to study the enthesis bursa. Interestingly, the Outcome Measures in Rheumatology Clinical Trials (OMERACT) enthesopathy definition does not include bursa as an elementary entheseal lesion. Nonetheless, bursa was included in 46% of the enthesis studies in a recently systematic literature review, being in agreement with the concept of “synovio-entheseal complex” that includes the link between enthesitis and osteitis in SpA. It has been clarified in recent data that there is not only a close functional integration of the enthesis with the neighboring bone, but also a connection between enthesitis and synovitis. Therefore, we tried to assess the prevalence and relevance of the bursa-synovial lesion in SpA. Our findings showed a significant increase of Achilles bursa presence and thickness in SpA patients compared to controls (healthy/mechanical controls and RA controls). These results raise awareness to the need to improve the enthesopathy ultrasonographic definition. In the final work of this thesis, we have explored new perspectives, not previously reported, about construct validity of enthesis ultrasound as a possible activity outcome in SpA. We performed a longitudinal Achilles enthesis ultrasound study in patients with early SpA. Achilles ultrasound examinations were performed at baseline, six- and twelve-month time periods and compared with clinical outcome measures collected at basal visit. Our results showed that basal erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP) are higher in patients with Doppler signal in enthesis, and even that higher basal ESR, CRP and Ankylosing Spondylitis Disease Activity Score (ASDAS) predicted a higher Doppler signal (an ultrasound alteration accepted as representative of inflammation) six months later. Patients with very high disease activity assessed by ASDAS (>3.5) at baseline had significantly higher Achilles total ultrasound score verified at the same time; and ASDAS <1.3 predicted no Doppler signal at six and twelve months. This seems to represent a connection between classical biomarkers and clinical outcomes associated with SpA activity and Doppler signal, not only at the same time, but also for the following months. Remarkably, patients with inactive disease (ASDAS < 1.3) at baseline had no Doppler signal at six and twelve months. These findings reinforce the potential use of ultrasound related techniques for disease progression assessment and prognosis purposes. Intriguingly, Ankylosing Spondylitis Disease Activity Index (BASDAI) didn’t show significant differences between different cut-offs concerning ultrasound lesions or Doppler signal, while verified with ASDAS. These results seem to indicate that ASDAS reflects better than BASDAI what happens in the enthesis. The work herein discussed clearly shows the potential utility of ultrasound in enthesis assessment in SpA patients, and can be important for the development of ultrasound activity and structural damage scores for diagnosis and monitoring purposes. Therefore, local promotion of this technique constitutes a medical intervention that is worth being tested in SpA patients for diagnosis, monitoring and prognosis purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate a diagnostic strategy for pulmonary embolism that combined clinical assessment, plasma D-dimer measurement, lower limb venous ultrasonography, and helical computed tomography (CT). METHODS: A cohort of 965 consecutive patients presenting to the emergency departments of three general and teaching hospitals with clinically suspected pulmonary embolism underwent sequential noninvasive testing. Clinical probability was assessed by a prediction rule combined with implicit judgment. All patients were followed for 3 months. RESULTS: A normal D-dimer level (&lt;500 microg/L by a rapid enzyme-linked immunosorbent assay) ruled out venous thromboembolism in 280 patients (29%), and finding a deep vein thrombosis by ultrasonography established the diagnosis in 92 patients (9.5%). Helical CT was required in only 593 patients (61%) and showed pulmonary embolism in 124 patients (12.8%). Pulmonary embolism was considered ruled out in the 450 patients (46.6%) with a negative ultrasound and CT scan and a low-to-intermediate clinical probability. The 8 patients with a negative ultrasound and CT scan despite a high clinical probability proceeded to pulmonary angiography (positive: 2; negative: 6). Helical CT was inconclusive in 11 patients (pulmonary embolism: 4; no pulmonary embolism: 7). The overall prevalence of pulmonary embolism was 23%. Patients classified as not having pulmonary embolism were not anticoagulated during follow-up and had a 3-month thromboembolic risk of 1.0% (95% confidence interval: 0.5% to 2.1%). CONCLUSION: A noninvasive diagnostic strategy combining clinical assessment, D-dimer measurement, ultrasonography, and helical CT yielded a diagnosis in 99% of outpatients suspected of pulmonary embolism, and appeared to be safe, provided that CT was combined with ultrasonography to rule out the disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to compare the plaque morphology between coronary and peripheral arteries using intravascular ultrasound (IVUS). Methods: IVUS was performed in 68 patients with coronary and 93 with peripheral artery lesions (29 carotid, 50 renal, and 14 iliac). Plaques were classified as fibroatheroma (VH-FA) (further subclassified as thin-capped [VH-TCFA] and thick-capped [VH-ThCFA]), fibrocalcific plaque (VH-FC) and pathological intimal thickening (VH-PIT). Results: Plaque rupture (13% of coronary, 7% of carotid, 6% of renal, and 7% of iliac arteries; P=NS) and VH-TCFA (37% of coronary, 24% of carotid, 16% of renal, and 7% of iliac arteries; P=0.02) was observed in all arteries. Compared to coronary arteries, VH-FA was less frequently observed in renal (P<0.001) and iliac arteries (P<0.006), while VH-PIT and VH-FC were prevalent in both of these peripheral arteries. Lesions with positive remodeling demonstrated more characteristics of VH-FA in coronary, carotid, and renal arteries compared to those with intermediate/negative remodeling (all P<0.01). There was positive relationship between RI and percent necrotic core area in all four arteries. Conclusions: Atherosclerotic plaque phenotypes were heterogeneous among four different arteries. In contrast, the associations of remodeling mode with plaque phenotype and composition were similar among the various arterial beds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Surgery remains the treatment of choice for localized renal neoplasms. While radical nephrectomy was long considered the gold standard, partial nephrectomy has equivalent oncological results for small tumors. The role of negative surgical margins continues to be debated. Intraoperative frozen section analysis is expensive and time-consuming. We assessed the feasibility of intraoperative ex vivo ultrasound of resection margins in patients undergoing partial nephrectomy and its correlation with margin status on definitive pathological evaluation.Materials and Methods: A study was done at 2 institutions from February 2008 to March 2011. Patients undergoing partial nephrectomy for T1-T2 renal tumors were included in analysis. Partial nephrectomy was done by a standardized minimal healthy tissue margin technique. After resection the specimen was kept in saline and tumor margin status was immediately determined by ex vivo ultrasound. Sequential images were obtained to evaluate the whole tumor pseudocapsule. Results were compared with margin status on definitive pathological evaluation.Results: A total of 19 men and 14 women with a mean +/- SD age of 62 +/- 11 years were included in analysis. Intraoperative ex vivo ultrasound revealed negative surgical margins in 30 cases and positive margins in 2 while it could not be done in 1. Final pathological results revealed negative margins in all except 1 case. Ultrasound sensitivity and specificity were 100% and 97%, respectively. Median ultrasound duration was 1 minute. Mean tumor and margin size was 3.6 +/- 2.2 cm and 1.5 +/- 0.7 mm, respectively.Conclusions: Intraoperative ex vivo ultrasound of resection margins in patients undergoing partial nephrectomy is feasible and efficient. Large sample studies are needed to confirm its promising accuracy to determine margin status.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasound detection of sub-clinical atherosclerosis (ATS) may help identify individuals at high cardiovascular risk. Most studies evaluated intima-media thickness (IMT) at carotid level. We compared the relationships between main cardiovascular risk factors (CVRF) and five indicators of ATS (IMT, mean and maximal plaque thickness, mean and maximal plaque area) at both carotid and femoral levels. Ultrasound was performed on 496 participants aged 45-64 years randomly selected from the general population of the Republic of Seychelles. 73.4 % participants had ≥ 1 plaque (IMT thickening ≥ 1.2 mm) at carotid level and 67.5 % at femoral level. Variance (adjusted R2) contributed by age, sex and CVRF (smoking, LDL-cholesterol, HDL-cholesterol, blood pressure, diabetes) in predicting any of the ATS markers was larger at femoral than carotid level. At both carotid and femoral levels, the association between CVRF and ATS was stronger based on plaque-based markers than IMT. Our findings show that the associations between CVRF and ATS markers were stronger at femoral than carotid level, and with plaque-based markers rather than IMT. Pending comparison of these markers using harder cardiovascular endpoints, our findings suggest that markers based on plaque morphology assessed at femoral artery level might be useful cardiovascular risk predictors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of the present work was assess the feasibility of using a pseudo-inverse and null-space optimization approach in the modeling of the shoulder biomechanics. The method was applied to a simplified musculoskeletal shoulder model. The mechanical system consisted in the arm, and the external forces were the arm weight, 6 scapulo-humeral muscles and the reaction at the glenohumeral joint, which was considered as a spherical joint. The muscle wrapping was considered around the humeral head assumed spherical. The dynamical equations were solved in a Lagrangian approach. The mathematical redundancy of the mechanical system was solved in two steps: a pseudo-inverse optimization to minimize the square of the muscle stress and a null-space optimization to restrict the muscle force to physiological limits. Several movements were simulated. The mathematical and numerical aspects of the constrained redundancy problem were efficiently solved by the proposed method. The prediction of muscle moment arms was consistent with cadaveric measurements and the joint reaction force was consistent with in vivo measurements. This preliminary work demonstrated that the developed algorithm has a great potential for more complex musculoskeletal modeling of the shoulder joint. In particular it could be further applied to a non-spherical joint model, allowing for the natural translation of the humeral head in the glenoid fossa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endorectal ultrasonography has become the preferred exam to assess the local extent of rectal cancers. From 1990 to 1992, we have examined 28 patients with a rectal cancer. The tumours were classified according to the TNM. The objective of this exam is to identify patients whose tumours have invaded the perirectal fat. These patients are first treated in our clinic by an accelerated hyperfractionated radiotherapy and then operated. The preoperative staging made with the endorectal ultrasound was then compared with the anatomopathologic staging. The depth of the invasion was assessed precisely in 78.5% of cases. The exam's sensitivity to detect the invasion of the perirectal fat was 96% and its specificity 75%. Lymph node involvement was accurately identified in 67.8% of cases with a sensitivity of 81% and a specificity of 50%. This short retrospective study confirms that endorectal ultrasonography is a highly accurate tool for the staging of rectal carcinoma prior to operation and hence to select the patients that can benefit from preoperative irradiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Several guidelines recommend computed tomography scans for populations with high-risk for lung cancer. The number of individuals evaluated for peripheral pulmonary lesions (PPL) will probably increase, and with it non-surgical biopsies. Associating a guidance method with a target confirmation technique has been shown to achieve the highest diagnostic yield, but the utility of bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy as guidance without a guide sheath has not been reported. METHODS: We conducted a retrospective analysis of bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy procedures for the investigation of PPL performed by experienced bronchoscopists with no specific previous training in this particular technique. Operator learning curves and radiological predictors were assessed for all consecutive patients examined during the first year of application of the technique. RESULTS: Fifty-one PPL were investigated. Diagnostic yield and visualization yield were 72.5 and 82.3% respectively. The diagnostic yield was 64.0% for PPL ≤20mm, and 80.8% for PPL>20mm. No false-positive results were recorded. The learning curve of all diagnostic tools showed a DY of 72.7% for the first sub-group of patients, 81.8% for the second, 72.7% for the third, and 81.8% for the last. CONCLUSION: Bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy as guidance is safe and simple to perform, even without specific prior training, and diagnostic yield is high for PPL>and ≤20mm. Based on these findings, this method could be introduced as a first-line procedure for the investigation of PPL, particularly in centers with limited resources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L’accident vasculaire cérébral (AVC) est une cause principale de décès et de morbidité dans le monde; une bonne partie des AVC est causée par la plaque d’athérosclérose carotidienne. La prévention de l’AVC chez les patients ayant une plaque carotidienne demeure controversée, vu les risques et bénéfices ambigus associés au traitement chirurgical ou médical. Plusieurs méthodes d’imagerie ont été développées afin d’étudier la plaque vulnérable (dont le risque est élevé), mais aucune n’est suffisamment validée ou accessible pour permettre une utilisation comme outil de dépistage. L’élastographie non-invasive vasculaire (NIVE) est une technique nouvelle qui cartographie les déformations (élasticité) de la plaque afin de détecter les plaque vulnérables; cette technique n’est pas encore validée cliniquement. Le but de ce projet est d’évaluer la capacité de NIVE de caractériser la composition de la plaque et sa vulnérabilité in vivo chez des patients ayant des plaques sévères carotidiennes, en utilisant comme étalon de référence, l’imagerie par résonance magnétique (IRM) à haute-résolution. Afin de poursuivre cette étude, une connaissance accrue de l’AVC, l’athérosclérose, la plaque vulnérable, ainsi que des techniques actuelles d’imagerie de la plaque carotidienne, est requise. Trente-et-un sujets ont été examinés par NIVE par ultrasonographie et IRM à haute-résolution. Sur 31 plaques, 9 étaient symptomatiques, 17 contenaient des lipides, et 7 étaient vulnérables selon l’IRM. Les déformations étaient significativement plus petites chez les plaques contenant des lipides, avec une sensibilité élevée et une spécificité modérée. Une association quadratique entre la déformation et la quantité de lipide a été trouvée. Les déformations ne pouvaient pas distinguer les plaques vulnérables ou symptomatiques. En conclusion, NIVE par ultrasonographie est faisable chez des patients ayant des sténoses carotidiennes significatives et peut détecter la présence d’un coeur lipidique. Des études supplémentaires de progression de la plaque avec NIVE sont requises afin d’identifier les plaques vulnérables.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les diagnostics cliniques des maladies cardio-vasculaires sont principalement effectués à l’aide d’échographies Doppler-couleur malgré ses restrictions : mesures de vélocité dépendantes de l’angle ainsi qu’une fréquence d’images plus faible à cause de focalisation traditionnelle. Deux études, utilisant des approches différentes, adressent ces restrictions en utilisant l’imagerie à onde-plane, post-traitée avec des méthodes de délai et sommation et d’autocorrélation. L’objectif de la présente étude est de ré-implémenté ces méthodes pour analyser certains paramètres qui affecte la précision des estimations de la vélocité du flux sanguin en utilisant le Doppler vectoriel 2D. À l’aide d’expériences in vitro sur des flux paraboliques stationnaires effectuées avec un système Verasonics, l’impact de quatre paramètres sur la précision de la cartographie a été évalué : le nombre d’inclinaisons par orientation, la longueur d’ensemble pour les images à orientation unique, le nombre de cycles par pulsation, ainsi que l’angle de l’orientation pour différents flux. Les valeurs optimales sont de 7 inclinaisons par orientation, une orientation de ±15° avec 6 cycles par pulsation. La précision de la reconstruction est comparable à l’échographie Doppler conventionnelle, tout en ayant une fréquence d’image 10 à 20 fois supérieure, permettant une meilleure caractérisation des transitions rapides qui requiert une résolution temporelle élevée.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dans le contexte de la caractérisation des tissus mammaires, on peut se demander ce que l’examen d’un attribut en échographie quantitative (« quantitative ultrasound » - QUS) d’un milieu diffusant (tel un tissu biologique mou) pendant la propagation d’une onde de cisaillement ajoute à son pouvoir discriminant. Ce travail présente une étude du comportement variable temporel de trois paramètres statistiques (l’intensité moyenne, le paramètre de structure et le paramètre de regroupement des diffuseurs) d’un modèle général pour l’enveloppe écho de l’onde ultrasonore rétrodiffusée (c.-à-d., la K-distribution homodyne) sous la propagation des ondes de cisaillement. Des ondes de cisaillement transitoires ont été générés en utilisant la mèthode d’ imagerie de cisaillement supersonique ( «supersonic shear imaging » - SSI) dans trois fantômes in-vitro macroscopiquement homogènes imitant le sein avec des propriétés mécaniques différentes, et deux fantômes ex-vivo hétérogénes avec tumeurs de souris incluses dans un milieu environnant d’agargélatine. Une comparaison de l’étendue des trois paramètres de la K-distribution homodyne avec et sans propagation d’ondes de cisaillement a montré que les paramètres étaient significativement (p < 0,001) affectès par la propagation d’ondes de cisaillement dans les expériences in-vitro et ex-vivo. Les résultats ont également démontré que la plage dynamique des paramétres statistiques au cours de la propagation des ondes de cisaillement peut aider à discriminer (avec p < 0,001) les trois fantômes homogènes in-vitro les uns des autres, ainsi que les tumeurs de souris de leur milieu environnant dans les fantômes hétérogénes ex-vivo. De plus, un modéle de régression linéaire a été appliqué pour corréler la plage de l’intensité moyenne sous la propagation des ondes de cisaillement avec l’amplitude maximale de déplacement du « speckle » ultrasonore. La régression linéaire obtenue a été significative : fantômes in vitro : R2 = 0.98, p < 0,001 ; tumeurs ex-vivo : R2 = 0,56, p = 0,013 ; milieu environnant ex-vivo : R2 = 0,59, p = 0,009. En revanche, la régression linéaire n’a pas été aussi significative entre l’intensité moyenne sans propagation d’ondes de cisaillement et les propriétés mécaniques du milieu : fantômes in vitro : R2 = 0,07, p = 0,328, tumeurs ex-vivo : R2 = 0,55, p = 0,022 ; milieu environnant ex-vivo : R2 = 0,45, p = 0,047. Cette nouvelle approche peut fournir des informations supplémentaires à l’échographie quantitative statistique traditionnellement réalisée dans un cadre statique (c.-à-d., sans propagation d’ondes de cisaillement), par exemple, dans le contexte de l’imagerie ultrasonore en vue de la classification du cancer du sein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Problématique : La quantification de l’intégrité du tendon d’Achille (TA) représente un défi en réadaptation. L’adoption de mesures quantitatives du TA, extraites à partir d’une image ultrasonographique (QUS), pourrait remédier à cette lacune. Objectifs : 1) Évaluer la fiabilité test-retest et la précision de mesures QUS du TA; 2) Déterminer le meilleur protocole de collecte de mesures QUS à employer en pratique clinique. Méthodologie : Un total de 23 TAs présentant des symptômes d’une tendinopathie achilléenne et 63 TAs asymptomatiques ont été évalués. Pour chaque TA, 8 images ont été enregistrées (2 visites * 2 évaluatrices * 2 images). Différents types de mesures QUS ont été prises : géométriques (épaisseur, largeur, aire), dérivées d’un histogramme des niveaux de gris et dérivées d’une matrice de co-occurrence. Une étude de généralisabilité a quantifié la fiabilité et la précision de chaque mesure QUS et une étude de décision a fait ressortir les meilleurs protocoles de prise de mesures. Résultats : Les mesures géométriques ont démontré une excellente fiabilité et précision. Les mesures dérivées de l’histogramme des niveaux de gris ont démontré une fiabilité et précision médiocres. Les mesures dérivées d’une matrice de co-occurrence ont démontré une fiabilité modérée à excellente et une précision variable. En pratique clinique, il est recommandé de moyenner les résultats de trois images collectées par un évaluateur lors d’une visite. Conclusion : L’utilisation des mesures QUS géométriques permet de quantifier l’intégrité du TA (clinique et recherche). Davantage d’études sur les mesures QUS dérivées d’une matrice de co-occurrence s’avèrent nécessaires.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poly(ethylene terephthalate) (PET) based nanocomposites have been prepared with single walled carbon nanotubes (SWNTs) through an ultrasound assisted dissolution-evaporation method. Differential scanning calorimetry studies showed that SWNTs nucleate crystallization in PET at weight fractions as low as 0.3%, as the nanocomposite melt crystallized during cooling at temperature 24 °C higher than neat PET of identical molecular weight. Isothermal crystallization studies also revealed that SWNTs significantly accelerate the crystallization process. Mechanical properties of the PETSWNT nanocomposites improved as compared to neat PET indicating the effective reinforcement provided by nanotubes in the polymer matrix. Electrical conductivity measurements on the nanocomposite films showed that SWNTs at concentrations exceeding 1 wt% in the PET matrix result in electrical percolation. Comparison of crystallization, conductivity and transmission electron microscopy studies revealed that ultrasound assisted dissolution-evaporation method enables more effective dispersion of SWNTs in the PET matrix as compared to the melt compounding method

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this modern complex world, stress at work is found to be increasingly a common feature in day to day life. For the same reason, job stress is one of the active areas in occupational health and safety research for over last four decades and is continuing to attract researchers in academia and industry. Job stress in process industries is of concern due to its influence on process safety, and worker‘s safety and health. Safety in process (chemical and nuclear material) industry is of paramount importance, especially in a thickly populated country like India. Stress at job is the main vector in inducing work related musculoskeletal disorders which in turn can affect the worker health and safety in process industries. In view of the above, the process industries should try to minimize the job stress in workers to ensure a safe and healthy working climate for the industry and the worker. This research is mainly aimed at assessing the influence of job stress in inducing work related musculoskeletal disorders in chemical process industries in India