981 resultados para Medical simulation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of air and bone interfaces makes the dose distribution for head and neck cancer treatments difficult to accurately predict. This study compared planning system dose calculations using the collapsed-cone convolution algorithm with EGSnrcMonte Carlo simulation results obtained using the Monte Carlo DICOMToolKit software, for one oropharynx, two paranasal sinus and three nodal treatment plans. The difference between median doses obtained from the treatment planning and Monte Carlo calculations was found to be greatest in two bilateral treatments: 4.8%for a retropharyngeal node irradiation and 6.7% for an ethmoid paranasal sinus treatment. These deviations in median dose were smaller for two unilateral treatments: 0.8% for an infraclavicular node irradiation and 2.8% for a cervical node treatment. Examination of isodose distributions indicated that the largest deviations between Monte Carlo simulation and collapsed-cone convolution calculations were seen in the bilateral treatments, where the increase in calculated dose beyond air cavities was most significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Although several validated nutritional screening tools have been developed to “triage” inpatients for malnutrition diagnosis and intervention, there continues to be debate in the literature as to which tool/tools clinicians should use in practice. This study compared the accuracy of seven validated screening tools in older medical inpatients against two validated nutritional assessment methods. Methods This was a prospective cohort study of medical inpatients at least 65 y old. Malnutrition screening was conducted using seven tools recommended in evidence-based guidelines. Nutritional status was assessed by an accredited practicing dietitian using the Subjective Global Assessment (SGA) and the Mini-Nutritional Assessment (MNA). Energy intake was observed on a single day during first week of hospitalization. Results In this sample of 134 participants (80 ± 8 y old, 50% women), there was fair agreement between the SGA and MNA (κ = 0.53), with MNA identifying more “at-risk” patients and the SGA better identifying existing malnutrition. Most tools were accurate in identifying patients with malnutrition as determined by the SGA, in particular the Malnutrition Screening Tool and the Nutritional Risk Screening 2002. The MNA Short Form was most accurate at identifying nutritional risk according to the MNA. No tool accurately predicted patients with inadequate energy intake in the hospital. Conclusion Because all tools generally performed well, clinicians should consider choosing a screening tool that best aligns with their chosen nutritional assessment and is easiest to implement in practice. This study confirmed the importance of rescreening and monitoring food intake to allow the early identification and prevention of nutritional decline in patients with a poor intake during hospitalization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Teleradiology allows medical images to be transmitted over electronic networks for clinical interpretation, and for improved healthcare access, delivery and standards. Although, such remote transmission of the images is raising various new and complex legal and ethical issues, including image retention and fraud, privacy, malpractice liability, etc., considerations of the security measures used in teleradiology remain unchanged. Addressing this problem naturally warrants investigations on the security measures for their relative functional limitations and for the scope of considering them further. In this paper, starting with various security and privacy standards, the security requirements of medical images as well as expected threats in teleradiology are reviewed. This will make it possible to determine the limitations of the conventional measures used against the expected threats. Further, we thoroughly study the utilization of digital watermarking for teleradiology. Following the key attributes and roles of various watermarking parameters, justification for watermarking over conventional security measures is made in terms of their various objectives, properties, and requirements. We also outline the main objectives of medical image watermarking for teleradiology, and provide recommendations on suitable watermarking techniques and their characterization. Finally, concluding remarks and directions for future research are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A breaker restrike is an abnormal arcing phenomenon, leading to a possible breaker failure. Eventually, this failure leads to interruption of the transmission and distribution of the electricity supply system until the breaker is replaced. Before 2008, there was little evidence in the literature of monitoring techniques based on restrike measurement and interpretation produced during switching of capacitor banks and shunt reactor banks in power systems. In 2008 a non-intrusive radiometric restrike measurement method and a restrike hardware detection algorithm were developed by M.S. Ramli and B. Kasztenny. However, the limitations of the radiometric measurement method are a band limited frequency response as well as limitations in amplitude determination. Current restrike detection methods and algorithms require the use of wide bandwidth current transformers and high voltage dividers. A restrike switch model using Alternative Transient Program (ATP) and Wavelet Transforms which support diagnostics are proposed. Restrike phenomena become a new diagnostic process using measurements, ATP and Wavelet Transforms for online interrupter monitoring. This research project investigates the restrike switch model Parameter „A. dielectric voltage gradient related to a normal and slowed case of the contact opening velocity and the escalation voltages, which can be used as a diagnostic tool for a vacuum circuit-breaker (CB) at service voltages between 11 kV and 63 kV. During current interruption of an inductive load at current quenching or chopping, a transient voltage is developed across the contact gap. The dielectric strength of the gap should rise to a point to withstand this transient voltage. If it does not, the gap will flash over, resulting in a restrike. A straight line is fitted through the voltage points at flashover of the contact gap. This is the point at which the gap voltage has reached a value that exceeds the dielectric strength of the gap. This research shows that a change in opening contact velocity of the vacuum CB produces a corresponding change in the slope of the gap escalation voltage envelope. To investigate the diagnostic process, an ATP restrike switch model was modified with contact opening velocity computation for restrike waveform signature analyses along with experimental investigations. This also enhanced a mathematical CB model with the empirical dielectric model for SF6 (sulphur hexa-fluoride) CBs at service voltages above 63 kV and a generalised dielectric curve model for 12 kV CBs. A CB restrike can be predicted if there is a similar type of restrike waveform signatures for measured and simulated waveforms. The restrike switch model applications are used for: computer simulations as virtual experiments, including predicting breaker restrikes; estimating the interrupter remaining life of SF6 puffer CBs; checking system stresses; assessing point-on-wave (POW) operations; and for a restrike detection algorithm development using Wavelet Transforms. A simulated high frequency nozzle current magnitude was applied to an Equation (derived from the literature) which can calculate the life extension of the interrupter of a SF6 high voltage CB. The restrike waveform signatures for a medium and high voltage CB identify its possible failure mechanism such as delayed opening, degraded dielectric strength and improper contact travel. The simulated and measured restrike waveform signatures are analysed using Matlab software for automatic detection. Experimental investigation of a 12 kV vacuum CB diagnostic was carried out for the parameter determination and a passive antenna calibration was also successfully developed with applications for field implementation. The degradation features were also evaluated with a predictive interpretation technique from the experiments, and the subsequent simulation indicates that the drop in voltage related to the slow opening velocity mechanism measurement to give a degree of contact degradation. A predictive interpretation technique is a computer modeling for assessing switching device performance, which allows one to vary a single parameter at a time; this is often difficult to do experimentally because of the variable contact opening velocity. The significance of this thesis outcome is that it is a non-intrusive method developed using measurements, ATP and Wavelet Transforms to predict and interpret a breaker restrike risk. The measurements on high voltage circuit-breakers can identify degradation that can interrupt the distribution and transmission of an electricity supply system. It is hoped that the techniques for the monitoring of restrike phenomena developed by this research will form part of a diagnostic process that will be valuable for detecting breaker stresses relating to the interrupter lifetime. Suggestions for future research, including a field implementation proposal to validate the restrike switch model for ATP system studies and the hot dielectric strength curve model for SF6 CBs, are given in Appendix A.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Australian e-Health Research Centre and Queensland University of Technology recently participated in the TREC 2011 Medical Records Track. This paper reports on our methods, results and experience using a concept-based information retrieval approach. Our concept-based approach is intended to overcome specific challenges we identify in searching medical records. Queries and documents are transformed from their term-based originals into medical concepts as de ned by the SNOMED-CT ontology. Results show our concept-based approach performed above the median in all three performance metrics: bref (+12%), R-prec (+18%) and Prec@10 (+6%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A number of groups around the world are working in the field of three dimensional(3D) ultrasound (US) in order to obtain higher quality diagnostic information. 3D US, in general, involves collecting a sequence of conventional 2D US images along with information on the position and orientation of each image plane. A transformation matrix is calculated relating image space to real world space. This allows image pixels and region of interest (ROI) points drawn on the image to be displayed in 3D. The 3D data can be used for the production of volume or surface rendered images, or for the direct calculation of ROI volumes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to investigate the effect of very small air gaps (less than 1 mm) on the dosimetry of small photon fields used for stereotactic treatments. Measurements were performed with optically stimulated luminescent dosimeters (OSLDs) for 6 MV photons on a Varian 21iX linear accelerator with a Brainlab μMLC attachment for square field sizes down to 6 mm × 6 mm. Monte Carlo simulations were performed using EGSnrc C++ user code cavity. It was found that the Monte Carlo model used in this study accurately simulated the OSLD measurements on the linear accelerator. For the 6 mm field size, the 0.5 mm air gap upstream to the active area of the OSLD caused a 5.3 % dose reduction relative to a Monte Carlo simulation with no air gap. A hypothetical 0.2 mm air gap caused a dose reduction > 2 %, emphasizing the fact that even the tiniest air gaps can cause a large reduction in measured dose. The negligible effect on an 18 mm field size illustrated that the electronic disequilibrium caused by such small air gaps only affects the dosimetry of the very small fields. When performing small field dosimetry, care must be taken to avoid any air gaps, as can be often present when inserting detectors into solid phantoms. It is recommended that very small field dosimetry is performed in liquid water. When using small photon fields, sub-millimetre air gaps can also affect patient dosimetry if they cannot be spatially resolved on a CT scan. However the effect on the patient is debatable as the dose reduction caused by a 1 mm air gap, starting out at 19% in the first 0.1 mm behind the air gap, decreases to < 5 % after just 2 mm, and electronic equilibrium is fully re-established after just 5 mm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In microscopic traffic simulators, the interaction between vehicles is considered. The dynamics of the system then becomes an emergent property of the interaction between its components. Such interactions include lane-changing, car-following behaviours and intersection management. Although, in some cases, such simulators produce realistic prediction, they do not allow for an important aspect of the dynamics, that is, the driver-vehicle interaction. This paper introduces a physically sound vehicle-driver model for realistic microscopic simulation. By building a nanoscopic traffic simulation model that uses steering angle and throttle position as parameters, the model aims to overcome unrealistic acceleration and deceleration values, as found in various microscopic simulation tools. A physics engine calculates the driving force of the vehicle, and the preliminary results presented here, show that, through a realistic driver-vehicle-environment simulator, it becomes possible to model realistic driver and vehicle behaviours in a traffic simulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Physical inactivity is a modifiable risk factor for many chronic conditions and a leading cause of premature mortality. An increasing proportion of adults worldwide are not engaging in a level of physical activity sufficient to prevent or alleviate these adverse effects. Medical professionals have been identified as potentially powerful sources of influence for those who do not meet minimum physical activity guidelines. Health professionals are respected and expected sources of advice and they reach a large and relevant proportion of the population. Despite this potential, health professionals are not routinely practicing physical activity promotion. Discussion Medical professionals experience several known barriers to physical activity promotion including lack of time and lack of perceived efficacy in changing physical activity behaviour in patients. Furthermore, evidence for effective physical activity promotion by medical professionals is inconclusive. To address these problems, new approaches to physical activity promotion are being proposed. These include collaborating with community based physical activity behaviour change interventions, preparing patients for effective brief counselling during a consultation with the medical professional, and use of interactive behaviour change technology. Summary It is important that we recognise the latent risk of physical inactivity among patients presenting in clinical settings. Preparation for improving patient physical activity behaviours should commence before the consultation and may include physical activity screening. Medical professionals should also identify suitable community interventions to which they can refer physically inactive patients. Outsourcing the majority of a comprehensive physical activity intervention to community based interventions will reduce the required clinical consultation time for addressing the issue with each patient. Priorities for future research include investigating ways to promote successful referrals and subsequent engagement in comprehensive community support programs to increase physical activity levels of inactive patients. Additionally, future clinical trials of physical activity interventions should be evaluated in the context of a broader framework of outcomes to inform a systematic consideration of broad strengths and weaknesses regarding not only efficacy but cost-effectiveness and likelihood of successful translation of interventions to clinical contexts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sound knowledge of pathological disease processes is required for professional practice within health professions. The project described in this paper reviewed the resources currently available for the delivery of systematic pathology tutorials. Additional complementary resources were developed and the inclusion of these additional learning resources in practical tutorial sessions was evaluated for their impact on student learning. Student evaluation of the learning resources was undertaken across one semester with two different cohorts of health profession students using questionnaires and focus group discussion. Both cohorts reported an enhancement to their understanding of pathological disease processes through the use of the additional resources. Results indicate student perception of the value of the resources correlates with staff perception and is independent of prior experiences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The emergence of digital technologies has created enthusiasm for their application to student learning. An evolving issue in medical imaging is how these technologies might be implemented within programs. Method A review of the literature was performed to explore applications and issues of educational technology in medical imaging Results There are a range of applications for educational technology within medical imaging education however limitations do exist. Learners must be supported by the development of skills to utilize education technologies. The digital picture archival and communication environment presents an ideal opportunity to enhance student learning through interaction and engagement with images. Implementation of education technologies to support student placement activities is an area for future development provided equity of access is addressed. Conclusion Education technologies have specific application to medical imaging education as part of a blended curriculum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate the effects of adopting a pull system in assembly lines in contrast to a push system, simulation software called “ARENA” is used as a tool in order to present numerical results from both systems. Simulation scenarios are created to evaluate the effects of attributes changing in assembly systems, with influential factors including the change of manufacturing system (push system to pull system) and variation of demand. Moreover, pull system manufacturing consists of the addition attribute, which is the number of buffer storage. This paper will provide an analysis based on a previous case study, hence process time and workflow refer to the journal name “Optimising and simulating the assembly line balancing problem in a motorcycle manufacturing company: a case study” [2]. The implementation of the pull system mechanism is to produce a system improvement in terms of the number of Work-In-Process (WIP), total time of products in the system, and the number of finished product inventory, while retaining the same throughput.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To identify the factors associated with infertility, seeking advice and treatment with fertility hormones and/or in vitro fertilisation (IVF) among a general population of women. METHODS: Participants in the Australian Longitudinal Study on Women's Health aged 28-33 years in 2006 had completed up to four mailed surveys over 10 years (n=9,145). Parsimonious multivariate logistic regression was used to identify the socio-demographic, biological (including reproductive histories), and behavioural factors associated with infertility, advice and hormonal/IVF treatment. RESULTS: For women who had tried to conceive or had been pregnant (n=5,936), 17% reported infertility. Among women with infertility (n=1031), 72% (n=728) sought advice but only 50% (n=356) used hormonal/IVF treatment. Women had higher odds of infertility when: they had never been pregnant (OR=7.2, 95% CI 5.6-9.1) or had a history of miscarriage (OR range=1.5-4.0) than those who had given birth (and never had a miscarriage or termination). CONCLUSION: Only one-third of women with infertility used hormonal and/or IVF treatment. Women with PCOS or endometriosis were the most proactive in having sought advice and used hormonal/IVF treatment. IMPLICATIONS: Raised awareness of age-related declining fertility is important for partnered women aged approximately 30 years to encourage pregnancy during their prime reproductive years and reduce the risk of infertility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To investigate the mental and general health of infertile women who had not sought medical advice for their recognized infertility and were therefore not represented in clinical populations. Design: Longitudinal cohort study.Setting Population based.Patient(s) Participants in the Australian Longitudinal Study on Women's Health aged 28-33 years in 2006 who had ever tried to conceive or had been pregnant (n = 5,936).Intervention(s) None.Main Outcome Measure(s) Infertility, not seeking medical advice. Result(s): Compared with fertile women (n = 4,905), infertile women (n = 1,031) had higher odds of self-reported depression (odds ratio [OR] 1.20, 95% confidence interval [CI] 1.01-1.43), endometriosis (5.43, 4.01-7.36), polycystic ovary syndrome (9.52, 7.30-12.41), irregular periods (1.99, 1.68-2.36), type II diabetes (4.70, 1.79-12.37), or gestational diabetes (1.66, 1.12-2.46). Compared with infertile women who sought medical advice (n = 728), those who had not sought medical advice (n = 303) had higher odds of self-reported depression (1.67, 1.18-2.37), other mental health problems (3.14, 1.14-8.64), urinary tract infections (1.67, 1.12-2.49), heavy periods (1.63, 1.16-2.29), or a cancer diagnosis (11.33, 2.57-49.89). Infertile women who had or had not sought medical advice had similar odds of reporting an anxiety disorder or anxiety-related symptoms. Conclusion(s): Women with self-reported depression were unlikely to have sought medical advice for infertility. Depression and depressive symptoms may be barriers to seeking medical advice for infertility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STUDY QUESTION: What is the self-reported use of in vitro fertilization (IVF) and ovulation induction (OI) in comparison with insurance claims by Australian women aged 28–36 years? SUMMARY ANSWER: The self-reported use of IVF is quite likely to be valid; however, the use of OI is less well reported. WHAT IS KNOWN AND WHAT THIS PAPER ADDS: Population-based research often relies on the self-reported use of IVF and OI because access to medical records can be difficult and the data need to include sufficient personal identifying information for linkage to other data sources. There have been few attempts to explore the reliability of the self-reported use of IVF and OI using the linkage to medical insurance claims for either treatment. STUDY DESIGN: This prospective, population-based, longitudinal study included the cohort of women born during 1973–1978 and participating in the Australian Longitudinal Study on Women's Health (ALSWH) (n = 14247). From 1996 to 2009, participants were surveyed up to five times. PARTICIPANTS AND SETTING: Participants self-reported their use of IVF or OI in two mailed surveys when aged 28–33 and 31–36 years (n = 7280), respectively. This study links self-report survey responses and claims for treatment or medication from the universal national health insurance scheme (i.e. Medicare Australia). MAIN RESULTS AND THE ROLE OF CHANCE: Comparisons between self-reports and claims data were undertaken for all women consenting to the linkage (n = 3375). The self-reported use of IVF was compared with claims for OI for IVF (Kappa, K = 0.83), oocyte collection (K = 0.82), sperm preparation (K = 0.83), intracytoplasmic sperm injection (K = 0.40), fresh embryo transfers (K = 0.82), frozen embryo transfers (K = 0.64) and OI for IVF medication (K = 0.17). The self-reported use of OI was compared with ovulation monitoring (K = 0.52) and OI medication (K = 0.71). BIAS, CONFOUNDING AND OTHER REASONS FOR CAUTION: There is a possibility of selection bias due to the inclusion criteria for participants in this study: (1) completion of the last two surveys in a series of five and (2) consent to the linkage of their responses with Medicare data. GENERALIZABILITY TO OTHER POPULATIONS: The results are relevant to questionnaire-based research studies with infertile women in developed countries. STUDY FUNDING/COMPETING INTEREST(S): ALSWH is funded by the Australian Government Department of Health and Ageing. This research is funded by a National Health and Medical Research Council Centre of Research Excellence grant.