999 resultados para Mean values


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Statement of problem. Although most of the physical properties of denture base resin polymerized by microwave energy have been shown to be similar to resins polymerized by the conventional heat polymerization method, the presence of porosity is a problem.Purpose. This study evaluated the effect of different microwave polymerization cycles on the porosity of a denture base resin designed for microwave polymerization.Material and methods. Thirty-two rectangular resin specimens (65 X 40 X 5 mm) were divided into 3 experimental groups (A, B, and C; Onda-Cryl, microwave-polymerized resin) and I control group (T; Classico, heat-polymerized resin), according to the following polymerization cycles: (A) 500 W for 3 minutes, (B) 90 W for 13 minutes + 500 W for 90 seconds, (C) 320 W for 3 minutes + 0 W for 4 minutes + 720 W for 3 minutes, and (T) 74degreesC for 9 hours. Porosity was calculated by measurement of the specimen volume before and after its immersion in water. Data were analyzed using 1-way analysis of variance (alpha = .05).Results. The mean values and SDs of the percent mean porosity were: A = 1.05% +/- 0.28%, B = 0.91% +/- 0.15%, C = 0.88% +/- 0.23%, T = 0.93% +/- 0.23%. No significant differences were found in mean porosity among the groups evaluated.Conclusion. Within the limitations of this study, a denture base resin specifically designed for microwave Polymerization tested was not affected by different polymerization cycles. Porosity was similar to the conventional heat-polymerized denture base resin tested.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Statement of problem. Titanium has physical and mechanical properties, which have led to its increased use in dental prostheses despite casting difficulties due to high melting point and formation of oxide layers which affect the metal-ceramic bond strength.Purpose. This in vitro study evaluated the shear bond strength of the interface of 2 dental porcelains and pure titanium injected into a mold at 3 different temperatures.Material and methods. Using commercially pure (cp) titanium bars (Titanium, Grade I) melted at 1668degreesC and cast at mold temperatures of 430degreesC, 700degreesC or 900degreesC, 60 specimens were machined to 4 x 4 mm, with a base of 5 x 1 mm. The 4-mm surfaces were airborne-particle abraded with 100 mum aluminum oxide before applying and firing the bonding agent and evaluating the 2 porcelains (Triceram/Triline ti and Vita Titankeramik). Ten specimens were prepared for each temperature and porcelain combination Shear bond testing was performed in a universal testing machine, with a 500-kg load cell and crosshead speed of 0.5 mm/min. The specimens were loaded until failure. The interfaces of representative fractured specimens of each temperature were examined with a scanning electron microscope (SEM) and energy dispersive spectrometer (EDS). Data for shear bond strength (MPa) were statistically analyzed by 2-way ANOVA and the Tukey test (alpha = .05).Results. The results showed significant differences for the metal/porcelain interaction effect (P = .0464). There were no significant differences for the 2 porcelains (P = .4250). The Tukey test showed a significant difference between the pair cp Ti 430degreesC Triceram and cp Ti 900degreesC Triceram, with respective mean values and SDs of 59.74 +/- 11.62 and 34.03 +/- 10.35 MPa.Conclusion. Triceram porcelain showed a bond strength decrease with an increase in the mold temperature for casting titanium. The highest bond strength for Vita porcelain and the best metal-ceramic interface observed with the SEM were found with the mold temperature of 700degreesC.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objectives of this study were to evaluate, through panoramic radiographs, the mesiodistal axial inclinations of the maxillary anterior teeth at the beginning and end of nonextraction orthodontic treatment, and to compare the results with the mesiodistal axial inclinations of a control sample with normal (acceptable) occlusions. Methods: the experimental sample consisted of 40 white patients (20 male, 20 female; mean age, 14 years) with Class I maloccusions who were treated orthodontically with a standard edgewise (not preadjusted) technique without extractions. The mean treatment period was 1.6 years. The control sample comprised 42 white subjects (14 male, 28 female; age range, 12-17 years) with untreated normal (acceptable) occlusions. Panoramic radiographs were taken of the patients at the beginning (T1) and end (T2) of treatment. The mean values of the mesiodistal axial inclination at T1 were compared with the mean values at T2, and both were compared with the mesiodistal axial inclinations of the control sample. Results- the mesiodistal axial inclinations of the maxillary anterior teeth of the experimental group at T1 were different from those of the control group for 50% of the evaluated teeth. In contrast, the inclinations at T2 were consistent with the normal anatomical configuration of the controls. Conclusions: the panoramic radiograph is an effective tool for evaluating the mesiodistal axial inclinations of maxillary anterior teeth.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: To compare simulated periodontal bone defect depth measured in digital radiographs with dedicated and non-dedicated software systems and to compare the depth measurements from each program with the measurements in dry mandibles.Methods: Forty periodontal bone defects were created at the proximal area of the first premolar in dry pig mandibles. Measurements of the defects were performed with a periodontal probe in the dry mandible. Periapical digital radiographs of the defects were recorded using the Schick sensor in a standardized exposure setting. All images were read using a Schick dedicated software system (CDR DICOM for Windows v.3.5), and three commonly available non-dedicated software systems (Vix Win 2000 v.1.2; Adobe Photoshop 7.0 and Image Tool 3.0). The defects were measured three times in each image and a consensus was reached among three examiners using the four software systems. The difference between the radiographic measurements was analysed using analysis of variance (ANOVA) and by comparing the measurements from each software system with the dry mandibles measurements using Student's t-test.Results: the mean values of the bone defects measured in the radiographs were 5.07 rum, 5.06 rum, 5.01 mm and 5.11 mm for CDR Digital Image and Communication in Medicine (DICOM) for Windows, Vix Win, Adobe Photoshop, and Image Tool, respectively, and 6.67 mm for the dry mandible. The means of the measurements performed in the four software systems were not significantly different, ANOVA (P = 0.958). A significant underestimation of defect depth was obtained when we compared the mean depths from each software system with the dry mandible measurements (t-test; P congruent to 0.000).Conclusions: the periodontal bone defect measurements in dedicated and in three non-dedicated software systems were not significantly different, but they all underestimated the measurements when compared with the measurements obtained in the dry mandibles.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To evaluate the influence of different cross-head speeds on shear bond strength test on the dentin surface.Methods: One hundred and twenty extracted bovine incisors were embedded in polystyrene resin. The specimens were prepared by wet grinding with 320-, 400- and 600-grit Al2O3 paper exposing dentin. After the application of the adhesive system Single Bond (3M) to etched dentin, the composite resin Z-100 (3M) was applied and light cured. The specimens were randomly assigned to four groups (n = 30). The shear bond strength tests were performed with an EMIC DL 500 universal testing machine at four different cross-head speeds: 0.50 (A); 0.75 (B); 1.00 (C); and 5.00 mm/min (D).Results: the mean values of shear bond strength in MPa (SD) were: A, 11.78 (3.91); B, 11.82 (4.78); C, 16.32 (6.45); D, 15.46 (5.94). The data were analyzed with one-way ANOVA and Tukey's test (alpha = 0.05). The results indicated that A = B < C = D. The fracture pattern was evaluated by visual analysis in a stereomicroscope (25 x). The percentage of fractures that occurred at the adhesive interface were: A, 92.5%; B, 91.6%; C, 70.0%; D, 47.0%. The Student's t-test to percentages ( = 0.05) indicated that there were no significant differences among A, B and C; A and B differed from D, and there was no significant difference between C and D.Significance: Different cross-head speeds may influence the shear bond strength and the fracture pattern in dentin substrate. Shear bond strength using cross-head speeds of 0.50 and 0.75 mm/min should be preferred. (C) 2001 Academy of Dental Materials. published by Elsevier B.V. Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Genetic and environmental effects on parturition interval (PI) and duration of lactation (DL) were evaluated in 107 Jafarabadi, 98 Mediterranean, 1027 Murrah and 624 crossbred buffalo females (n=1856), based on data from the Buffalo Genetic Improvement Program-PROMEBUL from 1980 to 2003. The statistical model included effects of herd, parturition year and month, calf's sex, parturition order and genetic group, composing 11, 34, 12, 2, 12 and 4 classes, respectively. A significant effect over PI was observed (P<0.01) in all classes, excepting sex. Mean parturition intervals per genetic group presented significant differences through SNK test (P<0.05), with mean values of 451.29; 429.47; 406.97 and 389.78 days in Mediterranean, crossbred, Murrah and Jafarabadi, respectively. Mean DL values were 276.68; 270.33; 258.03 and 235.59 days for Mediterranean, Murrah, crossbred and Jafarabadi groups, respectively. No significant differences in DL were observed in relation to genetic groups. However, herd and parturition order, year and month significantly influenced DL (P<0.01). The herd was the main source of variation over DL, followed by parturition year and month. A regression based on parturition month in relation to PI and DL showed that females giving birth in the last months of the year presented higher PI and DL.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Statement of problem. Prosthetic restorations that fit poorly may affect periodontal health and occlusion. Studies that have evaluated the accuracy of fit of ceramic restorations before and after cementation assessed primarily intracoronal restorations.Purpose. This in vitro study evaluated the effect of different finish lines, ceramic manufacturing techniques, and luting agents on the vertical discrepancy of ceramic copings.Material and methods. Two stainless steel molars were prepared for complete crowns with 2 different finish lines (heavy chamfer and rounded shoulder); each molar was duplicated to fabricate 90 copings. A total of 180 copings generated 18 groups (n=10 for each finish line-coping material-luting agent combination). Luting agents tested included zinc phosphate, resin-modified glass ionomer (Fuji Plus), and resin composite cements (Panavia F). A metal frame was developed on which to screw the stainless steel model and a ceramic coping; the distance (mum) between 2 predetermined points was measured before and after cementation by a profile projector under a torquing force. A 4-way ANOVA with repeated measurements was performed to assess the influence of each factor in the vertical marginal discrepancy: 3 between-coping factors (finish line-coping material-luting agent) and 1 within-coping factor (before and after cementation) (alpha=.05).Results. Procera copings presented the lowest mean values (P<.05) of vertical marginal discrepancy before and after cementation (25/44 mum) when compared to Empress 2 (68/110 mum) and InCeram Alumina copings (57/117 mum), regardless of any combinations among all finish lines and luting agents tested.Conclusion. Considering each factor separately, the ceramic manufacturing technique appeared to be the most important factor tested for the definitive vertical discrepancy of all-ceramic copings, with lower mean values for Procera copings.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate the number and the diameter of dentin tubules in root canals, in the cervical, middle, and apical thirds, of human and bovine teeth. Twenty-four single-rooted, human premolars were divided into four groups (n = 6): GH1, 10 to 15 years; GH2, 16 to 30 years; GH3, 31 to 45 years; and GH4, 46 to 80 years; and 24 bovine incisors were divided into four groups (n = 6): GB1, central; GB2, lateral first; GB3, lateral second; and GB4, lateral third. The crowns were removed from the specimens, which were then debrided, sectioned longitudinally in the vestibular-lingual direction, and submitted to ultrasonic cleaning. Scanning electron microscopic evaluations were made with 1,000x and 5,000x magnification. According to the root thirds, statistically significant differences were found both for the number and the diameter of dentin tubules, with the cervical third presenting the highest mean values for both specimen types. As regards the number of dentin tubules, it was observed that the bovine specimens presented a significantly higher mean value than the human specimens; this difference was not observed when the diameters of the two types were compared.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To assess the effect of soy protein and progressive resistance training on body composition and lipids in postmenopausal women.Design: In a controlled trial, 46 postmenopausal women were randomized to one of four groups: 25 g of soy protein (SP, n = 10), 25 g of soy protein plus resistance exercise (SPE, n = 14), 25 g of maltodextrine (placebo) (PL, n = 11), or placebo plus resistance exercise (PLE, n = 11). Progressive resistance training was held three times a week for 16 weeks and included 8 exercises (3 series of 8-12 repetitions). At baseline and after 16 weeks, body mass index, waist circumference (WC), body fat, muscle mass and serum lipid levels were measured. To confirm isoflavone absorption, urinary concentrations were determined. The t-test of Student and ANOVA were used in the statistical analysis.Results: Subjects were classified as overweight and showed android fat distribution: Urinary isoflavone excretion indicated compliance to soy protein treatment. After 16 weeks of intervention, both SPE and PLE groups showed a significant increase of 1.3 kg in muscle mass and reduction in WC of -1.4 and -2.1 cm, respectively (p < 0.05). Significant decreases in the mean values of total cholesterol and LDL (-29.0 and -24.0 mg/dL, p < 0.001 and p < 0.006, respectively) were observed in the users of soy protein alone (SP).Conclusions: Soy protein supplementation did not influence the indicators of body composition. However, it exerted possible favorable effects on lipid profile in postmenopausal women. The increase in muscle mass and reduction in abdominal fat were correlated with resistance training. (c) 2006 Elsevier B.V.. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Granulocyte colony-stimulating factor (G-CSF) regulates granulocyte precursor cell proliferation, neutrophil survival, and activation. Cyclic hematopoiesis, a disease that occurs both in humans and grey collie dogs is characterized by cyclical variations in blood neutrophils. Although the underlying molecular defect is not known, long-term daily administration of recombinant G-CSF eliminates the severe recurrent neutropenia, indicating that expression of G-CSF by gene therapy would be beneficial. As a prelude to preclinical studies in affected collie dogs, we monitored hematopoiesis in rats receiving vascular smooth muscle cells transduced to express G-CSF. Cells transduced with LrGSN, a retrovirus expressing rat G-CSF, were implanted in the carotid artery and control animals received cells transduced with LASN, a retrovirus expressing human adenosine deaminase (ADA). Test animals showed significant increases in neutrophil counts for at least 7 weeks, with mean values of 3,670 +/- 740 cells/mu l in comparison to 1,870 +/- 460 cells/mu l in controls (p < 0.001). Thus, in rats G-CSF gene transfer targeted at vascular smooth muscle cells initiated sustained production of 1,800 neutrophils/mu l, a cell number that would provide clinical benefit to patients. Lymphocytes, red cells and platelets were not different between control and test animals (p > 0.05). These studies indicate that retrovirally transduced vascular smooth muscle cells can provide sustained clinically useful levels of neutrophils in vivo.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A lesion nematode population infecting citrus in the state of São Paulo, Brazil is described and named Pratylenchus jaehni sp. n. Biological, molecular and morphological characteristics of this new species are compared with those of the morphologically similar P. coffeae and P. loosi. Results of mating experiments showed that R jaehni is reproductively isolated from P coffeae. Molecular (D2/D3 DNA sequences) dissimilarities among P. jaehni sp, n., P. coffeae and P. loosi were documented in a previous study. The morphology of seven R coffeae populations from tropical America and eastern Java and a P loosi population from Sri Lanka is used for comparison with the morphology of P. jaehni sp. n. Pratylenchus jaehni differs from R coffeae and P. loosi by only a few morphological ;characters of the females. The mean values of stylet length, stylet knob height, and vulva position are smaller (less than or equal to15 vs greater than or equal to15 mum, less than or equal to2.7 vs greater than or equal to2.7 mum, less than or equal to79 vs greater than or equal to79%) than those in P coffeae and P loosi. The tail terminus is usually subhemispherical and smooth in P jaehni sp. n.. whereas it is commonly truncate and indented in most P. coffeae populations and bluntly or finely pointed in P. loosi. Because of the morphological similarities among P. jaehni sp. n., P. coffeae and P. loosi, examination of at least ten specimens is required to obtain a reliable diagnosis based on morphology. Nineteen morphometric parameters for P. jaehni sp. n. and P. coffeae ranged from 0-13% smaller in fixed than in live specimens.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Corn plants were ensiled at the milk, milk-early dough, medium dough, and semi-hard dough stages. The intake and digestibility trials showed that: a) silage DM and NFE contents increased and ADF, cellulose, and lignin contents decreased with plant maturity; b) corn plant maturity had little effect on the digestibility of the silages, but the milk and medium dough stages produced the best results; c) no consistent effect of maturity was observed in DM and CP daily intakes (mean values 41.86 and 26.77/g/kg(75), respectively). Nevertheless, daily digestible dry matter and digestible protein intakes (g/kg(75)) were higher with medium-dough grains (31.74 and 1.97g, respectively) than with the milk (23.27 and 1.45g, respectively) and the milk-early dough stages (22.60 and 1.28g, respectively). However, similar intakes were observed with the medium-dough and semi-hard dough stages. Total digestible nutrient contents of the silages were affected little by corn plant maturity. Nevertheless, statistical differences were Found between the medium dough (70.09%) and the milk-early dough stages (63.07%).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

About similar to 2.1 x 10(-3) Mol SiO2 cm(-3) and similar to 88%-volume liquid-phase silica wet gels were prepared from oxalic-acid-catalyzed tetraethoxysilane (TEOS) sonohydrolysis. Aerogels were obtained by supercritical CO2 extraction. The samples were analyzed by thermogravimetry, small-angle X-ray scattering and nitrogen adsorption. Wet gels can be described as mass fractal structures with fractal dimension D similar to 1.94 and structural characteristic length zeta changing between similar to 3.3 to similar to 3.0 nm in the studied range of the catalyst concentration. A fraction of the porosity is apparently eliminated in the supercritical process. The values of the BET specific surface S-BET, the total pore volume V-p and the mean pore size l(p) of the aerogels were found to change almost randomly around the mean values S-BET = 874 m(2) g(-1), V-p = 0.961 cm(3) g(-1) and l(p) = 4.4 nm with catalyst concentration variation. These values were not substantially different from those from an equivalent HCl-catalyzed aerogel. (c) 2007 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Statement of problem. Acrylic resin denture teeth soften upon immersion in water, and the heating generated during microwave sterilization may enhance this process.Purpose. Six brands of acrylic resin denture teeth were investigated with respect to the effect of microwave sterilization and water immersion on Vickers hardness (VHN).Material and Methods. The acrylic resin denture teeth (Dentron [D], Vipi Dent Plus [V], Postaris [P], Biolux [B], Trilux [T], and Artiplus [A]) were embedded in heat-polymerized acrylic resin within polyvinylchloride tubes. For each brand, the occlusal surfaces of 32 identical acrylic resin denture posterior teeth were ground flat with 1500-grit silicon carbide paper and polished on a wet polishing wheel with a slurry of tin oxide. Hardness tests were performed after polishing (control group, C) after polishing followed by 2 cycles of microwave sterilization at 650 W for 6 minutes (MwS group), after polishing followed by 90-day immersion in water (90-day Wim group), and after polishing followed by 90-day storage in water and 2 cycles of microwave sterilization (90-day Wim + MwS group). For each specimen, 8 hardness measurements were made and the mean was calculated. Data were analyzed with a 2-way analysis of variance followed by the Bonferroni procedure to determine any significance between pairs of mean values (alpha=.01).Results: Mircrowave sterilization of specimens significantly decreased (P <.001) the hardness of the acrylic resin denture tooth specimens P (17.8 to 16.6 VHN, V (18.3 to 15.8 VHN), T (17.4 to 15.3 VHN), B (16.8 to 15.7 VHN), and A (17.3 to 15.7 VHN). For all acrylic resin denture teeth, no significant differences in hardness were found between the groups Mws, 90-day Wim, and 90-day Wim + MwS, with the exception of the 90-day Wim + MwS tooth A specimens (14.4 VHN), which demonstrated significant lower mean values (P <.001) than the 90-day Wim (15.8 VHN) and MwS (15.7 VHN) specimens.Conclusions. For specimens immersed in water for 90 days, 2 cycles of microwave sterilization had no effect on the hardness of most of the acrylic resin denture teeth.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The study of the spatial variability of soil attributes under different crop helps the study of changes due the management. This research was carried out to determine spatial variability the particle-size distribution, using of the classic statistic and geostatistics, of a soil cultivated with pasture and native vegetation. Soil samples were collected in the layer 0-0.20m, at the crossing points of a regular grid with 10m-intervals, summing up 64 samples points in each area. In the pasture area the fractions of coarse and total sand presented larger mean values in relation to the native vegetation, and negative correlation with the altitude of the points samples in the two areas. All of the fractions presented moderate to high spatial dependence in the two areas and with the defined still, with exception of the fine sand and the silt in the pasture. Much of this variability occurs as a function of water erosion.