946 resultados para Mean square analysis
Resumo:
Background, Cardiac complications occur commonly in vascular surgery patients. Diagnosis of cardiac complications is difficult because of the inaccuracies associated with traditional cardiac enzyme measurements. CTi, a highly sensitive and specific marker of myocardial injury, may be able to detect cardiac complications with greater ease and accuracy. Methods. The study prospectively examined 100 consecutive patients who underwent major vascular surgery between 6/7/98 and 31/12/98 at the Royal Brisbane Hospital. Daily measurements of cTi, creatine kinase (CK), creatine kinase MB (CKMB), CKMB index, renal function and haemoglobin were taken for three postoperative days. One postoperative electrocardiograph (ECC) was taken. An extensive cardiac history was taken. Intraoperative and postoperative events were recorded. Findings. There were 100 patients, 18 patients (18%) had a cTi elevation. On the basis of classical diagnostic criteria, 15 patients (15%) suffered one or more cardiac complication (either myocardial infarction, congestive cardiac failure, unstable angina or atrial fibrillation), One patient (1%) who had a cTi elevation died. CTI elevation occurred in five patients (5%) who were not diagnosed with cardiac complications based on traditional criteria. Despite not meeting specific diagnostic criteria for cardiac complications, all patients showed signs and symptoms that could be attributed to myocardial ischaemia, Every patient who developed congestive cardiac failure or atrial fibrillation had a cTi elevation. A Chi-square analysis revealed a significant association between cTi elevation and postoperative cardiac complications. Four variables contributed small but significant amounts of unique variance to the prediction of peak cTi on linear regression analysis. These were peak CKMB index, postoperative congestive cardiac failure, postoperative chest pain and postoperative cardiac complications. Conclusions. Routine cTi monitoring of postoperative vascular patients would be an effective and inexpensive way to detect patients with cardiac complications. The relationship between postoperative cTi elevation and significant coronary artery disease remains to be shown, (C) 2001 The international Society for Cardiovascular Surgery. Published by Elsevier Science Ltd. All rights reserved.
Resumo:
Objective: To explore circadian variation in pain, stiffness, and manual dexterity inpatients with hand osteoarthritis (OA). Methods: Twenty one patients with hand OA, as defined by ACR criteria (17 women, four men, mean age 62.2 years, range 52-74 years) self rated pain and stiffness on separate 10 cm horizontal visual analogue scales and performed bead intubation coordinometry (BIC) six times each day (on waking up, at bedtime, and every four hours in between) for 10 consecutive days. Each series (using data with the trend removed if there was a significant trend) was analysed for circadian rhythmicity by a cosine. vector technique (single cosinor). With individual data expressed as the percentage of the mean, group rhythm characteristics at period 24 hours were summarised for each variable by population mean cosinor analysis. Results: Individual analyses identified significant circadian rhythms at pless than or equal to0.05 for pain (n=15/21), stiffness (n=16/20), and dexterity (n=18/21), and a significant circadian rhythm on a group basis was identified for pain (p=0.013), stiffness (p
Resumo:
The purpose of this study was to determine whether or not losses of strength or endurance following eccentric and concentric exercise are associated with reduced excitation. The effects of eccentric and concentric work on maximal voluntary isometric contraction (MVC) and surface electromyogram (EMG) of the quadriceps were studied in 10 healthy male subjects following bench-stepping for 20 min with a constant leading leg. Prior to stepping and at 0, 0.25, 0.50, 0.75, 1, 3. 24 and 48 h afterwards the subjects performed a 30 s leg extension MVC with each leg during which the isometric force and the root mean square voltage of the EMG were recorded. In the eccentrically exercised muscles (ECC), MVC0-3 (force during the first 3 s of contraction) fen immediately after the bench-stepping exercise to 88 +/- 2% (mean SE) of the pre-exercise value and remained significantly lower than the concentrically exercised muscles (p < 0.05). The muscle weakness in the ECC could not be attributed to central fatigue as surface EMG amplitude at MVC0-3 increased during the recovery period. Muscle weakness after eccentric exercise appears to be due to contractile failure, which is not associated with a reduction in excitation as assessed by surface EMG. Muscular fatigue over 30 s did not change in the two muscle groups after exercise (p = 0.79), indicating that the ECC were weaker but not more fatiguable after exercise.
Resumo:
In this paper we construct predictor-corrector (PC) methods based on the trivial predictor and stochastic implicit Runge-Kutta (RK) correctors for solving stochastic differential equations. Using the colored rooted tree theory and stochastic B-series, the order condition theorem is derived for constructing stochastic RK methods based on PC implementations. We also present detailed order conditions of the PC methods using stochastic implicit RK correctors with strong global order 1.0 and 1.5. A two-stage implicit RK method with strong global order 1.0 and a four-stage implicit RK method with strong global order 1.5 used as the correctors are constructed in this paper. The mean-square stability properties and numerical results of the PC methods based on these two implicit RK correctors are reported.
Resumo:
Purpose: The aims of the present study were to examine electromyographic (EMG) activity of six bilateral trunk muscles during maximal contraction in three cardinal planes, and to determine the direction of contraction that gives maximal activation for each muscle. both for healthy subjects and back-pain patients. Methods: Twenty-eight healthy subjects and 15 back-pain patients performed maximum voluntary contractions in three cardinal planes, Surface EMG signals were recorded from rectus abdominis, external oblique, internal oblique, latissimus dorsi, iliocostalis lumborum, and multifidus bilaterally. Root mean square values of the EMG data were calculated to quantify I the amplitude of EMG signals. Results: For both healthy subjects and back-pain patients. one single direction of contraction was found to give the maximum EMG signals for most muscles. Rectus abdominis demonstrated maximal activity in trunk flexion, external oblique in lateral flexion. internal oblique in axial rotation, and multifidus in extension. For the latissimus dorsi and iliocostalis lumborum. maximal activity was demonstrated in more than one cardinal plane. Conclusion: This study has implications for future research involving normalization of muscle activity to maximal levels required in many trunk EMG studies. As the latissimus dorsi and iliocostalis lumborum demonstrate individual differences in the plane that gives maximal activity, these muscles may require testing in more than one plane.
Resumo:
Although the 12-lead electrocardiogram has become an essential medical and research tool, many current and envisaged applications would benefit from simpler devices, using 3-lead ECG configuration. This is particularly true for Ambient Assisted Living (in a broad perspective). However, the chest anatomy of female patients, namely during pregnancy, can hamper the adequate placement of a 3-lead ECG device and, very often, electrodes are placed below the chest rather than at the precise thoracic landmarks. Thus, the aim of this study was to compare the effect of electrode positioning on the ECG signal of pregnant women and provide guidelines for device development. The effect of breast tissue on the ECG signal was investigated by relating breast size with the signal-to-noise ratio, root mean square and R-wave amplitude. Results show that the 3-lead ECG should be placed on the breast rather than under the breast and indicate positive correlation between breast size and signal-to-noise ratio.
Resumo:
Com o presente estudo pretendeu-se: (1) verificar se a ligadura funcional para a lesão da articulação Acrómio-Clavicular (AC), descrita por Chanussot e Danowski (2001), contribui para o restabelecimento da força muscular num paciente com lesão grau III; e, (2) observar se a ligadura funcional altera o padrão electromiográfico dos principais músculos superficiais do complexo articular do ombro: infra-espinhoso, deltóide anterior, grande peitoral, trapézio superior e trapézio inferior. Efectuou-se assim um estudo de caso do tipo observacional, descritivo transversal. Para avaliação da força muscular foi utilizado um dinamómetro isocinético e para a avaliação do nível de activação de fibras musculares foi utilizada a EMG de superfície. Os movimentos em análise foram os de rotação interna e externa, a 60º/s e 180º/s. Os resultados revelaram, na presença de ligadura, um aumento do Peak Torque dos rotadores internos, assim como da actividade do grande peitoral e trapézio inferior. Constatou-se ainda uma diminuição do Peak Torque e da percentagem do Root Mean Square do trapézio inferior, trapézio superior e grande peitoral, do ombro esquerdo, sem ligadura, quando comparado com o ombro contralateral. A ligadura funcional, numa entorse da acromio-clavicular grau III, poderá contribuir para a recuperação de força muscular e activação de fibras musculares.
Resumo:
Introdução: O declínio do equilíbrio, da força dos membros inferiores e o medo de cair são fatores de risco de queda associados ao envelhecimento e a sua avaliação pode ser realizada pelo teste One Leg Standing (OLS), Sit to Stand (STS) e pela Falls Eficacy Scale (FES), respetivamente. As aplicações para smartphone constituem uma alternativa para a avaliação dos fatores de risco de queda no envelhecimento. Objetivo: Analisar a capacidade de uma aplicação para smartphone na avaliação dos testes STS, OLS e FES. Metodologia: Realizou-se um estudo analítico numa amostra de 27 voluntários com idade ≥ 60 anos. Realizaram-se os testes STS, OLS e a FES (versão iconográfica, apresentada no smartphone). Os dados foram recolhidos simultaneamente por um smartphone e pelo Qualisys Motion Capture Systems associado a uma plataforma de forças. Foi utilizado o r de Pearson ou Spearman para analisar as possíveis correlações. Resultados: No STS obteve-se uma correlação muito forte (rp=0.97) no número de repetições de ciclos Sit Stand Sit (SLS) e forte na duração média do SLS (rp=0.85) e das subfases Sit to Stand (rp=0.69) e Stand to Sit (rp=0.778), com p<0.001. As medidas de inclinação do tronco apresentaram correlações fortes, com exceção do ângulo inicial (p≥0.05). No OLS, verificou-se uma correlação moderada entre o deslocamento do centro de pressão peak to peak médio-lateral (rs=0.45; p=0.017) e antero-posterior (rs=0.39; p=0.046), root mean square médio-lateral (rs=0.39; p=0.046) e antero-posterior (rs=0.46; p=0.017) e área do estatocinesiograma (rs=0.45; p=0.018). Na FES obteve-se uma correlação moderada em três categorias: ‘tomar banho/duche’ (rs=0.49; p=0.010), ‘deitar/levantar da cama (rs=0.43; p=0.024) e ‘chegar aos armários’ (rs=0.38; p=0.050). Conclusão: A aplicação para smartphone parece avaliar corretamente os ciclos e a variação da inclinação do tronco no STS, porém parece necessitar de ser reajustada na FES e na velocidade do deslocamento do centro de pressão, no OLS.
Resumo:
In distributed video coding, motion estimation is typically performed at the decoder to generate the side information, increasing the decoder complexity while providing low complexity encoding in comparison with predictive video coding. Motion estimation can be performed once to create the side information or several times to refine the side information quality along the decoding process. In this paper, motion estimation is performed at the decoder side to generate multiple side information hypotheses which are adaptively and dynamically combined, whenever additional decoded information is available. The proposed iterative side information creation algorithm is inspired in video denoising filters and requires some statistics of the virtual channel between each side information hypothesis and the original data. With the proposed denoising algorithm for side information creation, a RD performance gain up to 1.2 dB is obtained for the same bitrate.
Resumo:
An Electrocardiogram (ECG) monitoring system deals with several challenges related with noise sources. The main goal of this text was the study of Adaptive Signal Processing Algorithms for ECG noise reduction when applied to real signals. This document presents an adaptive ltering technique based on Least Mean Square (LMS) algorithm to remove the artefacts caused by electromyography (EMG) and power line noise into ECG signal. For this experiments it was used real noise signals, mainly to observe the di erence between real noise and simulated noise sources. It was obtained very good results due to the ability of noise removing that can be reached with this technique. A recolha de sinais electrocardiogr a cos (ECG) sofre de diversos problemas relacionados com ru dos. O objectivo deste trabalho foi o estudo de algoritmos adaptativos para processamento digital de sinal, para redu c~ao de ru do em sinais ECG reais. Este texto apresenta uma t ecnica de redu c~ao de ru do baseada no algoritmo Least Mean Square (LMS) para remo c~ao de ru dos causados quer pela actividade muscular (EMG) quer por ru dos causados pela rede de energia el ectrica. Para as experiencias foram utilizados ru dos reais, principalmente para aferir a diferen ca de performance do algoritmo entre os sinais reais e os simulados. Foram conseguidos bons resultados, essencialmente devido as excelentes caracter sticas que esta t ecnica tem para remover ru dos.
Resumo:
Signal subspace identification is a crucial first step in many hyperspectral processing algorithms such as target detection, change detection, classification, and unmixing. The identification of this subspace enables a correct dimensionality reduction, yielding gains in algorithm performance and complexity and in data storage. This paper introduces a new minimum mean square error-based approach to infer the signal subspace in hyperspectral imagery. The method, which is termed hyperspectral signal identification by minimum error, is eigen decomposition based, unsupervised, and fully automatic (i.e., it does not depend on any tuning parameters). It first estimates the signal and noise correlation matrices and then selects the subset of eigenvalues that best represents the signal subspace in the least squared error sense. State-of-the-art performance of the proposed method is illustrated by using simulated and real hyperspectral images.
Resumo:
OBJETIVO: Avaliar a validade fatorial e de construto da versão brasileira do "Cuestionario para la Evaluación del Síndrome de Quemarse por el Trabajo" (CESQT). MÉTODOS: O processo de versão do questionário original do espanhol para o português incluiu as etapas de tradução, retrotradução e equivalência semântica. Foi realizada análise fatorial confirmatória e utilizados modelos de equações estruturais de quatro fatores, similar ao da estrutura original do CESQT. A amostra foi constituida de 714 professores que trabalhavam em instituições de ensino da cidade de Porto Alegre, RS, e região metropolitana 2008. O questionário possui 20 itens distribuídos em quatro subescalas: Ilusão pelo trabalho (5 itens), Desgaste psíquico (4 itens), Indolência (6 itens) e Culpa (5 itens). O modelo foi analisado com base no programa LISREL 8. RESULTADOS: As medidas de ajuste indicaram adequação do modelo hipotetizado: χ2(164) = 605,86 (p < 0,000), Goodness Fit Index = 0,92, Adjusted Goodness Fit Index = 0,90, Root Mean Square Error of Approximation = 0,062, Non-Normed Fit Index = 0,91, Comparative Fit Index = 0,92, Parsimony Normed Fit Index = 0,77. O valor de alfa de Cronbach para todas as subescalas foi maior que 0,70. CONCLUSÕES: Os resultados indicam que o CESQT possui validade fatorial e consistência interna adequada para avaliar burnout em professores brasileiros.
Resumo:
The characteristic topographical features (crystallite dimensions, surface morphology and roughness) of bioceramics may influence the adsorption of proteins relevant to bone regeneration. This work aims at analyzing the influence of two distinct nanophased hydroxyapatite (HA) ceramics, HA725 and HA1000 on fibronectin (FN) and osteonectin (ON) adsorption and MC3T3-E1 osteoblast adhesion and morphology. Both substrates were obtained using the same hydroxyapatite nanocrystals aggregates and applying the sintering temperatures of 725ºC and 1000ºC, respectively. The two proteins used in this work, FN as an adhesive glycoprotein and ON as a counter-adhesive protein, are known to be involved in the early stages of osteogenesis (cell adhesion, mobility and proliferation). The properties of the nanoHA substrates had an important role in the adsorption behavior of the two studied proteins and clearly affected the MC3T3- E1 morphology, distribution and metabolic activity. HA1000 surfaces presenting slightly larger grain size, higher root-mean-square roughness (Rq), lower surface area and porosity, allowed for higher amounts of both proteins adsorbed. These substrates also revealed increased number of exposed FN cell-binding domains as well as higher affinity for osteonectin. Regarding the osteoblast adhesion results, improved viability and cell number were found for HA1000 surfaces as compared to HA725 ones, independently of the presence or type of adsorbed protein. Therefore the osteoblast adhesion and metabolic activity seemed to be more sensitive to surfaces morphology and roughness than to the type of adsorbed proteins.
Resumo:
OBJETIVO: Realizar a adaptação transcultural da versão em português do Inventário de Burnout de Maslach para estudantes e investigar sua confiabilidade, validade e invariância transcultural. MÉTODOS: A validação de face envolveu participação de equipe multidisciplinar. Foi realizada validação de conteúdo. A versão em português foi preenchida em 2009, pela internet, por 958 estudantes universitários brasileiros e 556 portugueses da zona urbana. Realizou-se análise fatorial confirmatória utilizando-se como índices de ajustamento o χ²/df, o comparative fit index (CFI), goodness of fit index (GFI) e o root mean square error of approximation (RMSEA). Para verificação da estabilidade da solução fatorial conforme a versão original em inglês, realizou-se validação cruzada em 2/3 da amostra total e replicada no 1/3 restante. A validade convergente foi estimada pela variância extraída média e confiabilidade composta. Avaliou-se a validade discriminante e a consistência interna foi estimada pelo coeficiente alfa de Cronbach. A validade concorrente foi estimada por análise correlacional da versão em português e dos escores médios do Inventário de Burnout de Copenhague; a divergente foi comparada à Escala de Depressão de Beck. Foi avaliada a invariância do modelo entre a amostra brasileira e a portuguesa. RESULTADOS: O modelo trifatorial de Exaustão, Descrença e Eficácia apresentou ajustamento adequado (χ²/df = 8,498; CFI = 0,916; GFI = 0,902; RMSEA = 0,086). A estrutura fatorial foi estável (λ: χ²dif = 11,383, p = 0,50; Cov: χ²dif = 6,479, p = 0,372; Resíduos: χ²dif = 21,514, p = 0,121). Observou-se adequada validade convergente (VEM = 0,45;0,64, CC = 0,82;0,88), discriminante (ρ² = 0,06;0,33) e consistência interna (α = 0,83;0,88). A validade concorrente da versão em português com o Inventário de Copenhague foi adequada (r = 0,21;0,74). A avaliação da validade divergente do instrumento foi prejudicada pela aproximação do conceito teórico das dimensões Exaustão e Descrença da versão em português com a Escala de Beck. Não se observou invariância do instrumento entre as amostras brasileiras e portuguesas (λ:χ²dif = 84,768, p < 0,001; Cov: χ²dif = 129,206, p < 0,001; Resíduos: χ²dif = 518,760, p < 0,001). CONCLUSÕES: A versão em português do Inventário de Burnout de Maslach para estudantes apresentou adequada confiabilidade e validade, mas sua estrutura fatorial não foi invariante entre os países, apontando ausência de estabilidade transcultural.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações