834 resultados para Joint replacement
Resumo:
Audit report on the Iowa Water Pollution Control Works Financing Program (Clean Water Program) and the Iowa Drinking Water Facilities Financing Program (Drinking Water Program), joint programs of the Iowa Finance Authority and the Iowa Department of Natural Resources for the year ended June 30, 2009
Resumo:
OBJECTIVES: Transcatheter aortic valve replacement (TAVR) provides good results in selected high-risk patients. However, it is unclear whether this procedure carries advantages in extreme-risk profile patients with logistic EuroSCORE above 35%. METHODS: From January 2009 to July 2011, of a total number of 92 transcatheter aortic valve procedures performed, 40 'extreme-risk' patients underwent transapical TAVR (TA-TAVR) (EuroSCORE above 35%). Variables were analysed as risk factors for hospital and mid-term mortality, and a 2-year follow-up (FU) was obtained. RESULTS: The mean age was: 81 ± 10 years. Twelve patients (30%) had chronic pulmonary disease, 32 (80%) severe peripheral vascular disease, 14 (35%) previous cardiac surgery, 19 (48%) chronic renal failure (2 in dialysis), 7 (17%) previous stroke (1 with disabilities), 3 (7%) a porcelain aorta and 12 (30%) were urgent cases. Mean left ventricle ejection fraction (LVEF) was 49 ± 13%, and mean logistic EuroSCORE was 48 ± 11%. Forty stent-valves were successfully implanted with six Grade-1 and one Grade-2 paravalvular leakages (success rate: 100%). Hospital mortality was 20% (8 patients). Causes of death following the valve academic research consortium (VARC) definitions were: life-threatening haemorrhage (1), myocardial infarction (1), sudden death (1), multiorgan failure (2), stroke (1) and severe respiratory dysfunction (2). Major complications (VARC definitions) were: myocardial infarction for left coronary ostium occlusion (1), life-threatening bleeding (2), stroke (2) and acute kidney injury with dialysis (2). Predictors for hospital mortality were: conversion to sternotomy, life-threatening haemorrhage, postoperative dialysis and long intensive care unit (ICU) stay. Variables associated with hospital mortality were: conversion to sternotomy (P = 0.03), life-threatening bleeding (P = 0.02), acute kidney injury with dialysis (P = 0.03) and prolonged ICU stay (P = 0.02). Mean FU time was 24 months: actuarial survival estimates for all-cause mortality at 6 months, 1 year, 18 months and 2 years were 68, 57, 54 and 54%, respectively. Patients still alive at FU were in good clinical condition, New York Heart Association (NYHA) class 1-2 and were never rehospitalized for cardiac decompensation. CONCLUSIONS: TA-TAVR in extreme-risk patients carries a moderate risk of hospital mortality. Severe comorbidities and presence of residual paravalvular leakages affect the mid-term survival, whereas surviving patients have an acceptable quality of life without rehospitalizations for cardiac decompensation.
Resumo:
Traditionally, the transcatheter aortic valve replacement is performed through a transapical, a transfemoral or a trans-subclavian approach. Recently, the transaortic approach for transcatheter aortic valve replacement through the distal part of the ascending aorta was successfully implemented in order to avoid peripheral vascular access-related complications and apical life-threatening haemorrhage. The Sapien? stent valve has great transaortic potential because it can be loaded 'upside down' in different generations of delivery systems. However, because of their health regulatory systems and despite the launch, in 2012, of the latest generation of the Ascendra? delivery system, the Ascendra+?, specifically designed for transapical and transaortic valve placements, several countries are still using the first generations of Ascendra? (Ascendra? 1 and 2). This device was specifically designed for transapical procedures, and retrograde stent-valve positioning through the stenotic aortic valve may be very challenging and risk the integrity of the aorta. We describe the manoeuvre required in order to pass the stenotic aortic valve safely in a retrograde direction using the Sapien? stent valve and the first generations of Ascendra?.
Resumo:
Els dies 11 i 12 d'agost va tenir lloc a Copenhaguen, Dinamarca, el seminari de treball Library and Information Science Education in Europe: ¿Issues in joint curriculum development and Bologna perspectives¿. Aquest seminari, que va estar coordinat per la Royal School of Library and Information Science de Dinamarca, amb la col·laboració de l'European Association for Library and Information Education and Research (EUCLID), es va organitzar en el marc d'un projecte europeu subvencionat pel programa Sòcrates. La Facultat de Biblioteconomia i Documentació de la Universitat de Barcelona, present entre 2001 i 2005 en la Junta de Govern de l'EUCLID, va participar-hi com a soci del projecte. L'objectiu del seminari era aplegar una cinquantena d'experts europeus de l'àrea de Biblioteconomia i Documentació ¿tots ells professors d'escoles i de facultats d'universitats europees¿ per discutir qüestions relacionades amb els plans d'estudis dels ensenyaments des de la perspectiva del procés de Bolonya. El seminari consistí en dues conferències i en les reunions de treball de dotze grups formats per experts que examinaren dotze grans temes ¿prèviament acordats pels organitzadors de l'esdeveniment¿ relacionats amb els plans d'estudis d'aquells ensenyaments.
Resumo:
Background: Oral valganciclovir (VGC) is hydrolysed into active ganciclovir (GCV) which is eliminated in the kidney by filtration and secretion. VGC dosage has to be adapted in renal failure with continuous renal replacement therapy (CRRT), a condition sometimes encountered early after solid organ transplantation. This investigation aimed to determine whether VGC 450 mg every 48 hours provides appropriate GCV exposure for cytomegalovirus (CMV) prophylaxis during CRRT. Methods: GCV pharmacokinetics were extensively studied during CRRT in two lung transplant recipients with acute renal failure receiving VGC 450 mg every 48 hours trough a nasogastric tube. In vitro experiments using blank whole blood spiked with GCV further investigated exchanges between plasma and erythrocytes. Results: GCV disposition was characterised by an area under the curve (AUC) of 98.0 and 55.4 mg h/L, resulting in trough concentrations of 0.7 and 0.2 mg/L, an apparent total body clearance of 3.3 and 5.8 L/h, a terminal half-life of 16.9 and 14.1 h, and an apparent volume of distribution of 60.3 and 104.9 L. The observed sieving coefficient (filtrate/plasma) was 1.05 and 0.96, and the hemofiltration clearance 3.3 and 3.1 L/h, respectively. High sieving values could be explained by an efflux of GCV from erythrocytes. In vitro experiments confirmed that erythrocytes are loaded with significant GCV amount and release it quickly into plasma, thus contributing to the apparent efficacy of hemofiltration. Conclusion: These results indicate that a VGC dosage of 450 mg every 48 hours was adequate for CMV prophylaxis during CRRT, providing GCV levels similar to those reported using 900 mg qd in transplant recipients with normal renal function.
Resumo:
OBJECTIVE: Hypopituitarism is associated with an increased mortality rate but the reasons underlying this have not been fully elucidated. The purpose of this study was to evaluate mortality and associated factors within a large GH-replaced population of hypopituitary patients. DESIGN: In KIMS (Pfizer International Metabolic Database) 13,983 GH-deficient patients with 69,056 patient-years of follow-up were available. METHODS: This study analysed standardised mortality ratios (SMRs) by Poisson regression. IGF1 SDS was used as an indicator of adequacy of GH replacement. Statistical significance was set to P<0.05. RESULTS: All-cause mortality was 13% higher compared with normal population rates (SMR, 1.13; 95% confidence interval, 1.04-1.24). Significant associations were female gender, younger age at follow-up, underlying diagnosis of Cushing's disease, craniopharyngioma and aggressive tumour and presence of diabetes insipidus. After controlling for confounding factors, there were statistically significant negative associations between IGF1 SDS after 1, 2 and 3 years of GH replacement and SMR. For cause-specific mortality there was a negative association between 1-year IGF1 SDS and SMR for deaths from cardiovascular diseases (P=0.017) and malignancies (P=0.044). CONCLUSIONS: GH-replaced patients with hypopituitarism demonstrated a modest increase in mortality rate; this appears lower than that previously published in GH-deficient patients. Factors associated with increased mortality included female gender, younger attained age, aetiology and lower IGF1 SDS during therapy. These data indicate that GH replacement in hypopituitary adults with GH deficiency may be considered a safe treatment.
Resumo:
Selostus: Rypsipuristeen asteittainen korvaaminen pellavapuristeella lypsylehmien säilörehuun perustuvassa ruokinnassa
Resumo:
Microcrystals associated with joint diseases, namely monosodium urate, calcium pyrophosphate and basic calcium phosphate, can be considered as 'danger signals' to the innate immune system and provoke inflammation through inflammasome-dependent as well as inflammasome-independent pathways. Direct crystal membrane interactions can also lead to cell activation. The result is the generation of IL-1β and other pro-inflammatory cytokines. The primacy of IL-1β in the case of gouty inflammation has been demonstrated by the efficacy of IL-1 inhibitors in clinical studies. These findings may be relevant to other diseases where crystal formation is found, such as OA and atherosclerosis.
Resumo:
Introduction and summary Iowa Code § 8D.10 requires certain state agencies to prepare an annual report to the General Assembly certifying the identified savings associated with that state agency’s use of the Iowa Communications Network (ICN). This report covers estimated cost savings related to video conferencing via ICN for the Iowa Department of Transportation (DOT). In FY 2010, the DOT did not conduct any sessions utilizing ICN’s video conferencing system. Therefore, no cost savings were calculated for this report.
Resumo:
PURPOSE: To compare the diagnostic performance of multi-detector CT arthrography (CTA) and 1.5-T MR arthrography (MRA) in detecting hyaline cartilage lesions of the shoulder, with arthroscopic correlation. PATIENTS AND METHODS: CTA and MRA prospectively obtained in 56 consecutive patients following the same arthrographic procedure were independently evaluated for glenohumeral cartilage lesions (modified Outerbridge grade ≥2 and grade 4) by two musculoskeletal radiologists. The cartilage surface was divided in 18 anatomical areas. Arthroscopy was taken as the reference standard. Diagnostic performance of CTA and MRA was compared using ROC analysis. Interobserver and intraobserver agreement was determined by κ statistics. RESULTS: Sensitivity and specificity of CTA varied from 46.4 to 82.4 % and from 89.0 to 95.9 % respectively; sensitivity and specificity of MRA varied from 31.9 to 66.2 % and from 91.1 to 97.5 % respectively. Diagnostic performance of CTA was statistically significantly better than MRA for both readers (all p ≤ 0.04). Interobserver agreement for the evaluation of cartilage lesions was substantial with CTA (κ = 0.63) and moderate with MRA (κ = 0.54). Intraobserver agreement was almost perfect with both CTA (κ = 0.94-0.95) and MRA (κ = 0.83-0.87). CONCLUSION: The diagnostic performance of CTA and MRA for the detection of glenohumeral cartilage lesions is moderate, although statistically significantly better with CTA. KEY POINTS: ? CTA has moderate diagnostic performance for detecting glenohumeral cartilage substance loss. ? MRA has moderate diagnostic performance for detecting glenohumeral cartilage substance loss. ? CTA is more accurate than MRA for detecting cartilage substance loss.