996 resultados para Implementation accuracy
Resumo:
In this paper we present a set of axioms guaranteeing that, in exchange economies with or without indivisible goods, the set of Nash, Strong and active Walrasian Equilibria all coincide in the framework of market games.
Resumo:
Paper presented at the 2000 seminar of the International Chair in Olympism. The main topic includes references to how the demand of public investment must be legitimized in terms of public benefits that can be vindicated. The author tries to review the values of this legitimation individually and closely.
Resumo:
Purpose: To investigate the accuracy of 4 clinical instruments in the detection of glaucomatous damage. Methods: 102 eyes of 55 test subjects (Age mean = 66.5yrs, range = [39; 89]) underwent Heidelberg Retinal Tomography (HRTIII), (disc area<2.43); and standard automated perimetry (SAP) using Octopus (Dynamic); Pulsar (TOP); and Moorfields Motion Displacement Test (MDT) (ESTA strategy). Eyes were separated into three groups 1) Healthy (H): IOP<21mmHg and healthy discs (clinical examination), 39 subjects, 78 eyes; 2) Glaucoma suspect (GS): Suspicious discs (clinical examination), 12 subjects, 15 eyes; 3) Glaucoma (G): progressive structural or functional loss, 14 subjects, 20 eyes. Clinical diagnostic precision was examined using the cut-off associated with the p<5% normative limit of MD (Octopus/Pulsar), PTD (MDT) and MRA (HRT) analysis. The sensitivity, specificity and accuracy were calculated for each instrument. Results: See table Conclusions: Despite the advantage of defining glaucoma suspects using clinical optic disc examination, the HRT did not yield significantly higher accuracy than functional measures. HRT, MDT and Octopus SAP yielded higher accuracy than Pulsar perimetry, although results did not reach statistical significance. Further studies are required to investigate the structure-function correlations between these instruments.
Resumo:
BACKGROUND: A reorganization of healthcare systems is required to meet the challenge of the increasing prevalence of chronic diseases, e.g. diabetes. In North-America and Europe, several countries have thus developed national or regional chronic disease management programs. In Switzerland, such initiatives have only emerged recently. In 2010, the canton of Vaud set up the "Diabetes Cantonal Program", within the framework of which we conducted a study designed to ascertain the opinions of both diabetic patients and healthcare professionals on the elements that could be integrated into this program, the barriers and facilitators to its development, and the incentives that could motivate these actors to participate. METHODS: We organized eight focus-groups: one with diabetic patients and one with healthcare professionals in the four sanitary areas of the canton of Vaud. The discussions were recorded, transcribed and submitted to a thematic content analysis. RESULTS: Patients and healthcare professionals were rather in favour of the implementation of a cantonal program, although patients were more cautious concerning its necessity. All participants envisioned a set of elements that could be integrated to this program. They also considered that the program could be developed more easily if it were adapted to patients' and professionals' needs and if it used existing structures and professionals. The difficulty to motivate both patients and professionals to participate was mentioned as a barrier to the development of this program however. Quality or financial incentives could therefore be created to overcome this potential problem. CONCLUSION: The identification of the elements to consider, barriers, facilitators and incentives to participate to a chronic disease management program, obtained by exploring the opinions of patients and healthcare professionals, should favour its further development and implementation.
Resumo:
BACKGROUND: Robot surgery is a further step towards new potential developments in minimally invasive surgery. Surgeons must keep abreast of these new technologies and learn their limits and possibilities. Robot-assisted laparoscopic cholecystectomy has not yet been performed in our institution. The purpose of this report is to present the pathway of implementation of robotic laparoscopic cholecystectomy in a university hospital. METHODS: The Zeus(R) robot system was used. Experimental training was performed on animals. The results of our experimental training allowed us to perform our first two clinical cases. RESULTS: Robot arm set-up and trocar placement required 53 and 35 minutes. Operative time were 59 and 45 minutes respectively. The overall operative time was 112 and 80 minutes, respectively. There were no intraoperative complications. Patients were discharged from the hospital after an overnight stay. CONCLUSION: Robotic laparoscopic cholecystectomy is safe and patient recovery similar to those of standard laparoscopy. At present, there are no advantages of robotic over conventional surgery. Nevertheless, robots have the potential to revolutionise the way surgery is performed. Robot surgery is not reserved for a happy few. This technology deserves more attention because it has the potential to change the way surgery is performed.
Resumo:
OBJECTIVE:: To examine the accuracy of brain multimodal monitoring-consisting of intracranial pressure, brain tissue PO2, and cerebral microdialysis-in detecting cerebral hypoperfusion in patients with severe traumatic brain injury. DESIGN:: Prospective single-center study. PATIENTS:: Patients with severe traumatic brain injury. SETTING:: Medico-surgical ICU, university hospital. INTERVENTION:: Intracranial pressure, brain tissue PO2, and cerebral microdialysis monitoring (right frontal lobe, apparently normal tissue) combined with cerebral blood flow measurements using perfusion CT. MEASUREMENTS AND MAIN RESULTS:: Cerebral blood flow was measured using perfusion CT in tissue area around intracranial monitoring (regional cerebral blood flow) and in bilateral supra-ventricular brain areas (global cerebral blood flow) and was matched to cerebral physiologic variables. The accuracy of intracranial monitoring to predict cerebral hypoperfusion (defined as an oligemic regional cerebral blood flow < 35 mL/100 g/min) was examined using area under the receiver-operating characteristic curves. Thirty perfusion CT scans (median, 27 hr [interquartile range, 20-45] after traumatic brain injury) were performed on 27 patients (age, 39 yr [24-54 yr]; Glasgow Coma Scale, 7 [6-8]; 24/27 [89%] with diffuse injury). Regional cerebral blood flow correlated significantly with global cerebral blood flow (Pearson r = 0.70, p < 0.01). Compared with normal regional cerebral blood flow (n = 16), low regional cerebral blood flow (n = 14) measurements had a higher proportion of samples with intracranial pressure more than 20 mm Hg (13% vs 30%), brain tissue PO2 less than 20 mm Hg (9% vs 20%), cerebral microdialysis glucose less than 1 mmol/L (22% vs 57%), and lactate/pyruvate ratio more than 40 (4% vs 14%; all p < 0.05). Compared with intracranial pressure monitoring alone (area under the receiver-operating characteristic curve, 0.74 [95% CI, 0.61-0.87]), monitoring intracranial pressure + brain tissue PO2 (area under the receiver-operating characteristic curve, 0.84 [0.74-0.93]) or intracranial pressure + brain tissue PO2+ cerebral microdialysis (area under the receiver-operating characteristic curve, 0.88 [0.79-0.96]) was significantly more accurate in predicting low regional cerebral blood flow (both p < 0.05). CONCLUSION:: Brain multimodal monitoring-including intracranial pressure, brain tissue PO2, and cerebral microdialysis-is more accurate than intracranial pressure monitoring alone in detecting cerebral hypoperfusion at the bedside in patients with severe traumatic brain injury and predominantly diffuse injury.
Resumo:
OBJECTIVE: To test the accuracy of a new pulse oximeter sensor based on transmittance and reflectance. This sensor makes transillumination of tissue unnecessary and allows measurements on the hand, forearm, foot, and lower limb. DESIGN: Prospective, open, nonrandomized criterion standard study. SETTING: Neonatal intensive care unit, tertiary care center. PATIENTS: Sequential sample of 54 critically ill neonates (gestational age 27 to 42 wks; postnatal age 1 to 28 days) with arterial catheters in place. MEASUREMENTS AND MAIN RESULTS: A total of 99 comparisons between pulse oximetry and arterial saturation were obtained. Comparison of femoral or umbilical arterial blood with transcutaneous measurements on the lower limb (n = 66) demonstrated an excellent correlation (r2 = .96). The mean difference was +1.44% +/- 3.51 (SD) % (range -11% to +8%). Comparison of the transcutaneous values with the radial artery saturation from the corresponding upper limb (n = 33) revealed a correlation coefficient of 0.94 with a mean error of +0.66% +/- 3.34% (range -6% to +7%). The mean difference between noninvasive and invasive measurements was least with the test sensor on the hand, intermediate on the calf and arm, and greatest on the foot. The mean error and its standard deviation were slightly larger for arterial saturation values < 90% than for values > or = 90%. CONCLUSION: Accurate pulse oximetry saturation can be acquired from the hand, forearm, foot, and calf of critically ill newborns using this new sensor.
Resumo:
Introduction: As part of the MicroArray Quality Control (MAQC)-II project, this analysis examines how the choice of univariate feature-selection methods and classification algorithms may influence the performance of genomic predictors under varying degrees of prediction difficulty represented by three clinically relevant endpoints. Methods: We used gene-expression data from 230 breast cancers (grouped into training and independent validation sets), and we examined 40 predictors (five univariate feature-selection methods combined with eight different classifiers) for each of the three endpoints. Their classification performance was estimated on the training set by using two different resampling methods and compared with the accuracy observed in the independent validation set. Results: A ranking of the three classification problems was obtained, and the performance of 120 models was estimated and assessed on an independent validation set. The bootstrapping estimates were closer to the validation performance than were the cross-validation estimates. The required sample size for each endpoint was estimated, and both gene-level and pathway-level analyses were performed on the obtained models. Conclusions: We showed that genomic predictor accuracy is determined largely by an interplay between sample size and classification difficulty. Variations on univariate feature-selection methods and choice of classification algorithm have only a modest impact on predictor performance, and several statistically equally good predictors can be developed for any given classification problem.
Predictors and accuracy of abnormal CT perfusion in 1296 consecutive acute ischemic stroke patients.
Resumo:
Freehand positioning of the femoral drill guide is difficult during hip resurfacing and the surgeon is often unsure of the implant position achieved peroperatively. The purpose of this study was to find out whether, by using a navigation system, acetabular and femoral component positioning could be made easier and more precise. Eighteen patients operated on by the same surgeon were matched by sex, age, BMI, diagnosis and ASA score (nine patients with computer assistance, nine with the regular ancillary). Pre-operative planning was done on standard AP and axial radiographs with CT scan views for the computer-assisted operations. The final position of implants was evaluated by the same radiographs for all patients. The follow-up was at least 1 year. No difference between both groups in terms of femoral component position was observed (p > 0.05). There was also no difference in femoral notching. A trend for a better cup position was observed for the navigated hips, especially for cup anteversion. There was no additional operating time for the navigated hips. Hip navigation for resurfacing surgery may allow improved visualisation and hip implant positioning, but its advantage probably will be more obvious with mini-incisions than with regular incision surgery.
Resumo:
OBJECTIVE: To elucidate the diagnostic accuracy of granulocyte colony-stimulating factor (G-CSF), interleukin-8 (IL-8), and interleukin-1 receptor antagonist (IL-1ra) in identifying patients with sepsis among critically ill pediatric patients with suspected infection. DESIGN AND SETTING: Nested case-control study in a multidisciplinary neonatal and pediatric intensive care unit (PICU) PATIENTS: PICU patients during a 12-month period with suspected infection, and plasma available from the time of clinical suspicion (254 episodes, 190 patients). MEASUREMENTS AND RESULTS: Plasma levels of G-CSF, IL-8, and IL-1ra. Episodes classified on the basis of clinical and bacteriological findings into: culture-confirmed sepsis, probable sepsis, localized infection, viral infection, and no infection. Plasma levels were significantly higher in episodes of culture-confirmed sepsis than in episodes with ruled-out infection. The area under the receiver operating characteristic curve was higher for IL-8 and G-CSF than for IL-1ra. Combining IL-8 and G-CSF improved the diagnostic performance, particularly as to the detection of Gram-negative sepsis. Sensitivity was low (<50%) in detecting Staphylococcus epidermidis bacteremia or localized infections. CONCLUSIONS: In this heterogeneous population of critically ill children with suspected infection, a model combining plasma levels of IL-8 and G-CSF identified patients with sepsis. Negative results do not rule out S. epidermidis bacteremia or locally confined infectious processes. The model requires validation in an independent data-set.
Implementation of IPM programs on European greenhouse tomato production areas: Tools and constraints
Resumo:
Whiteflies and whitefly-transmitted viruses are some of the major constraints on European tomato production. The main objectives of this study were to: identify where and why whiteflies are a major limitation on tomato crops; collect information about whiteflies and associated viruses; determine the available management tools; and identify key knowledge gaps and research priorities. This study was conducted within the framework of ENDURE (European Network for Durable Exploitation of Crop Protection Strategies). Two whitefly species are the main pests of tomato in Europe: Bemisia tabaci and Trialeurodes vaporariorum. Trialeurodes vaporariorum is widespread to all areas where greenhouse industry is present, and B. tabaci has invaded, since the early 1990’s, all the subtropical and tropical areas. Biotypes B and Q of B. tabaci are widespread and especially problematic. Other key tomato pests are Aculops lycopersici, Helicoverpa armigera, Frankliniella occidentalis, and leaf miners. Tomato crops are particularly susceptible to viruses causingTomato yellow leaf curl disease (TYLCD). High incidences of this disease are associated to high pressure of its vector, B. tabaci. The ranked importance of B. tabaci established in this study correlates with the levels of insecticide use, showing B. tabaci as one of the principal drivers behind chemical control. Confirmed cases of resistance to almost all insecticides have been reported. Integrated Pest Management based on biological control (IPM-BC) is applied in all the surveyed regions and identified as the strategy using fewer insecticides. Other IPM components include greenhouse netting and TYLCD-tolerant tomato cultivars. Sampling techniques differ between regions, where decisions are generally based upon whitefly densities and do not relate to control strategies or growing cycles. For population monitoring and control, whitefly species are always identified. In Europe IPM-BC is the recommended strategy for a sustainable tomato production. The IPM-BC approach is mainly based on inoculative releases of the parasitoids Eretmocerus mundus and Encarsia formosa and/or the polyphagous predators Macrolophus caliginosus and Nesidiocoris tenuis. However, some limitations for a wider implementation have been identified: lack of biological solutions for some pests, costs of beneficials, low farmer confidence, costs of technical advice, and low pest injury thresholds. Research priorities to promote and improve IPM-BC are proposed on the following domains: (i) emergence and invasion of new whitefly-transmitted viruses; (ii) relevance of B. tabaci biotypes regarding insecticide resistance; (iii) biochemistry and genetics of plant resistance; (iv) economic thresholds and sampling techniques of whiteflies for decision making; and (v) conservation and management of native whitefly natural enemies and improvement of biological control of other tomato pests.
Resumo:
BACKGROUND: Chest pain is a common complaint in primary care, with coronary heart disease (CHD) being the most concerning of many potential causes. Systematic reviews on the sensitivity and specificity of symptoms and signs summarize the evidence about which of them are most useful in making a diagnosis. Previous meta-analyses are dominated by studies of patients referred to specialists. Moreover, as the analysis is typically based on study-level data, the statistical analyses in these reviews are limited while meta-analyses based on individual patient data can provide additional information. Our patient-level meta-analysis has three unique aims. First, we strive to determine the diagnostic accuracy of symptoms and signs for myocardial ischemia in primary care. Second, we investigate associations between study- or patient-level characteristics and measures of diagnostic accuracy. Third, we aim to validate existing clinical prediction rules for diagnosing myocardial ischemia in primary care. This article describes the methods of our study and six prospective studies of primary care patients with chest pain. Later articles will describe the main results. METHODS/DESIGN: We will conduct a systematic review and IPD meta-analysis of studies evaluating the diagnostic accuracy of symptoms and signs for diagnosing coronary heart disease in primary care. We will perform bivariate analyses to determine the sensitivity, specificity and likelihood ratios of individual symptoms and signs and multivariate analyses to explore the diagnostic value of an optimal combination of all symptoms and signs based on all data of all studies. We will validate existing clinical prediction rules from each of the included studies by calculating measures of diagnostic accuracy separately by study. DISCUSSION: Our study will face several methodological challenges. First, the number of studies will be limited. Second, the investigators of original studies defined some outcomes and predictors differently. Third, the studies did not collect the same standard clinical data set. Fourth, missing data, varying from partly missing to fully missing, will have to be dealt with.Despite these limitations, we aim to summarize the available evidence regarding the diagnostic accuracy of symptoms and signs for diagnosing CHD in patients presenting with chest pain in primary care. REVIEW REGISTRATION: Centre for Reviews and Dissemination (University of York): CRD42011001170.
Resumo:
The purpose of this study was to determine the prognostic accuracy of perfusion computed tomography (CT), performed at the time of emergency room admission, in acute stroke patients. Accuracy was determined by comparison of perfusion CT with delayed magnetic resonance (MR) and by monitoring the evolution of each patient's clinical condition. Twenty-two acute stroke patients underwent perfusion CT covering four contiguous 10mm slices on admission, as well as delayed MR, performed after a median interval of 3 days after emergency room admission. Eight were treated with thrombolytic agents. Infarct size on the admission perfusion CT was compared with that on the delayed diffusion-weighted (DWI)-MR, chosen as the gold standard. Delayed magnetic resonance angiography and perfusion-weighted MR were used to detect recanalization. A potential recuperation ratio, defined as PRR = penumbra size/(penumbra size + infarct size) on the admission perfusion CT, was compared with the evolution in each patient's clinical condition, defined by the National Institutes of Health Stroke Scale (NIHSS). In the 8 cases with arterial recanalization, the size of the cerebral infarct on the delayed DWI-MR was larger than or equal to that of the infarct on the admission perfusion CT, but smaller than or equal to that of the ischemic lesion on the admission perfusion CT; and the observed improvement in the NIHSS correlated with the PRR (correlation coefficient = 0.833). In the 14 cases with persistent arterial occlusion, infarct size on the delayed DWI-MR correlated with ischemic lesion size on the admission perfusion CT (r = 0.958). In all 22 patients, the admission NIHSS correlated with the size of the ischemic area on the admission perfusion CT (r = 0.627). Based on these findings, we conclude that perfusion CT allows the accurate prediction of the final infarct size and the evaluation of clinical prognosis for acute stroke patients at the time of emergency evaluation. It may also provide information about the extent of the penumbra. Perfusion CT could therefore be a valuable tool in the early management of acute stroke patients.