921 resultados para Immediate loading


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recent likely extinction of the baiji (Chinese river dolphin [Lipotes vexillifer]) (Turvey et al. 2007) makes the vaquita (Gulf of California porpoise [Phocoena sinus]) the most endangered cetacean. The vaquita has the smallest range of any porpoise, dolphin, or whale and, like the baiji, has long been threatened primarily by accidental deaths in fishing gear (bycatch) (Rojas-Bracho et al. 2006). Despite repeated recommendations from scientific bodies and conservation organizations, no effective actions have been taken to remove nets from the vaquita’s environment. Here, we address three questions that are important to vaquita conservation: (1) How many vaquitas remain? (2) How much time is left to find a solution to the bycatch problem? and (3) Are further abundance surveys or bycatch estimates needed to justify the immediate removal of all entangling nets from the range of the vaquita? Our answers are, in short: (1) there are about 150 vaquitas left, (2) there are at most 2 years within which to find a solution, and (3) further abundance surveys or bycatch estimates are not needed. The answers to the first two questions make clear that action is needed now, whereas the answer to the last question removes the excuse of uncertainty as a delay tactic. Herein we explain our reasoning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sediments of the Lagoa Vermelha (Red Lake), situated in the Ribeira Valley, southeastern Brazil, are made of a homogeneous, organic-rich, black clay with no visible sedimentary structures. The inorganic geochemical record (Al, As, Ba, Br, Co,Cs, Cr, Fe, Mn, Ni, Rb, Sc, Sb, V, Zn, Hg and Pb) of the lake sediments was analyzed in a core spanning 2430 years. The largest temporal changes in trace metal contents occurred approximately within the last 180 years. Recent sediments were found to be enriched in Pb, Zn, Hg, Ni, Mn, Br and Sb (more than 2-fold increase with respect to the "natural background level"). The enhanced accumulation of Br, Sb, and Mn was attributed to biogeochemical processes and diagenesis. On the other hand, the anomalous concentrations of Pb, Zn, Hg and Ni were attributed to pollution. As Lagoa Vermelha is located in a relatively pristine area, far removed from direct contamination sources, the increased metal contents of surface sediments most likely resulted from atmospheric fallout. Stable Pb isotopes provided additional evidence for anthropogenic contamination. The shift of Pb-206/Pb-207 ratios toward decreasing values in the increasingly younger sediments is consistent with an increasing contribution of airborne anthropogenic lead. In the uppermost sediments (0-10 cm), the lowest values of the Pb-206/Pb-207 ratios may reflect the influence of the less radiogenic Pb from the Ribeira Valley District ores (Pb-206/Pb-207 between 1.04 and 1.10), emitted during the last 50 years. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the immediate bond strength of etch-and-rinse adhesives to demineralized dentin saturated with either water or absolute ethanol. The research hypothesis was that there would be no difference in bond strength to dentin between water or ethanol wet-bonding techniques. The medium dentin of 20 third molars was exposed (n = 5). The dentin surface was then acid-etched, left moist and randomly assigned to be saturated via either water wet-bonding (WBT) or absolute ethanol wet-bonding (EBT). The specimens were then treated with one of the following etch-and-rinse adhesive systems: a 3-step, water-based system (Adper Scotchbond Multipurpose, or SBMP) or a 2-step, ethanol/water-based system (Adper Single Bond 2, or SB). Resin composite build-ups were then incrementally constructed. After water storage for 24 h at 37 degrees C, the tensile strength of the specimens was tested in a universal testing machine (0.5 mm/min). Data were analyzed by two-way ANOVA and Tukey's test (alpha = 5%). The failure modes were verified using a stereomicroscope (40x). For both adhesives, no significant difference in bond strength was observed between WBT and EBT (p > 0.05). The highest bond strength was observed for SB, regardless of the bonding technique (p < 0.05). No significant interaction between adhesives and bonding techniques was noticed (p = 0.597). There was a predominance of adhesive failures for all tested groups. The EBT and WBT displayed similar immediate bond strength means for both adhesives. The SB adhesive exhibited higher means for all conditions tested. Further investigations are needed to evaluate long-term bonding to dentin mediated by commercial etch-and-rinse adhesives using the EBT approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent studies in animals have shown pronounced resorption of the buccal bone plate after immediate implantation. The use of flapless surgical procedures prior to the installation of immediate implants, as well as the use of synthetic bone graft in the gaps represent viable alternatives to minimize buccal bone resorption and to favor osseointegration. The aim of this study was to evaluate the healing of the buccal bone plate following immediate implantation using the flapless approach, and to compare this process with sites in which a synthetic bone graft was or was not inserted into the gap between the implant and the buccal bone plate. Lower bicuspids from 8 dogs were bilaterally extracted without the use of flaps, and 4 implants were installed in the alveoli in each side of the mandible and were positioned 2.0 mm from the buccal bone plate (gap). Four groups were devised: 2.0-mm subcrestal implants (3.3 x 8 mm) using bone grafts (SCTG), 2.0-mm subcrestal implants without bone grafts (SCCG), equicrestal implants (3.3 x 10 mm) with bone grafts (EGG), and equicrestal implants without bone grafts (ECCG). One week following the surgical procedures, metallic prostheses were installed, and within 12 weeks the dogs were sacrificed. The blocks containing the individual implants were turned sideways, and radiographic imaging was obtained to analyze the remodeling of the buccal bone plate. In the analysis of the resulting distance between the implant shoulder and the bone crest, statistically significant differences were found in the SCTG when compared to the ECTG (P = .02) and ECCG (P = .03). For mean value comparison of the resulting linear distance between the implant surface and the buccal plate, no statistically significant difference was found among all groups (P > .05). The same result was observed in the parameter for presence or absence of tissue formation between the implant surface and buccal plate. Equicrestally placed implants, in this methodology, presented little or no loss of the buccal bone. The subcrestally positioned implants presented loss of buccal bone, even though synthetic bone graft was used. The buccal bone, however, was always coronal to the implant shoulder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paulo CA, Roschel H, Ugrinowitsch C, Kobal R and Tricoli V. Influence of different resistance exercise loading schemes on mechanical power output in work to rest ratio-equated and -nonequated conditions. J Strength Cond Res 26(5): 1308-1312, 2012-It is well known that most sports are characterized by the performance of intermittent high-intensity actions, requiring high muscle power production within different intervals. In fact, the manipulation of the exercise to rest ratio in muscle power training programs may constitute an interesting strategy when considering the specific performance demand of a given sport modality. Thus, the aim of this study was to evaluate the influence of different schemes of rest intervals and number of repetitions per set on muscle power production in the squat exercise between exercise to rest ratio-equated and -nonequated conditions. Nineteen young males (age: 25.7 +/- 4.4 years; weight: 81.3 +/- 13.7 kg; height: 178.1 +/- 5.5 cm) were randomly submitted to 3 different resistance exercise loading schemes, as follows: short-set short-interval condition (SSSI; 12 sets of 3 repetitions with a 27.3-second interval between sets); short-set long-interval condition (SSLI; 12 sets of 3 repetitions with a 60-second interval between sets); long-set long-interval (LSLI; 6 sets of 6 repetitions with a 60-second rest interval between sets). The main finding of the present study is that the lower exercise to rest ratio protocol (SSLI) resulted in greater average power production (601.88 +/- 142.48 W) when compared with both SSSI and LSLI (581.86 +/- 113.18 W; 578 +/- 138.78 W, respectively). Additionally, both the exercise to rest ratio-equated conditions presented similar performance and metabolic results. In summary, these findings suggest that shorter rest intervals may fully restore the individual's ability to produce muscle power if a smaller exercise volume per set is performed and that lower exercise to rest ratio protocols result in greater average power production when compared with higher ratio ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Accelerating bone healing around dental implants can reduce the long-term period between the insertion of implants and functional rehabilitation. Objective: This in vivo study evaluated the effect of a constant electromagnetic field (CEF) on bone healing around dental implants in dogs. Materials and methods: Eight dental implants were placed immediately after extraction of the first premolar and molar teeth on the mandible of two male dogs and divided into experimental (CEF) and control groups. A CEF at magnetic intensity of 0.8 mT with a pulse width of 25 mu s and frequency of 1.5 MHz was applied on the implants for 20 min per day for 2 weeks. Result and conclusion: After qualitative histological analysis, a small quantity of newly formed bone was observed in the gap between the implant surface and alveolar bone in both groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To evaluate the effect of insertion torque on micromotion to a lateral force in three different implant designs. Material and methods: Thirty-six implants with identical thread design, but different cutting groove design were divided in three groups: (1) non-fluted (no cutting groove, solid screw-form); (2) fluted (901 cut at the apex, tap design); and (3) Blossomt (Patent pending) (non-fluted with engineered trimmed thread design). The implants were screwed into polyurethane foam blocks and the insertion torque was recorded after each turn of 901 by a digital torque gauge. Controlled lateral loads of 10N followed by increments of 5 up to 100N were sequentially applied by a digital force gauge on a titanium abutment. Statistical comparison was performed with two-way mixed model ANOVA that evaluated implant design group, linear effects of turns and displacement loads, and their interaction. Results: While insertion torque increased as a function of number of turns for each design, the slope and final values increased (Po0.001) progressively from the Blossomt to the fluted to the non-fluted design (M +/- standard deviation [SD] = 64.1 +/- 26.8, 139.4 +/- 17.2, and 205.23 +/- 24.3 Ncm, respectively). While a linear relationship between horizontal displacement and lateral force was observed for each design, the slope and maximal displacement increased (Po0.001) progressively from the Blossomt to the fluted to the non-fluted design (M +/- SD 530 +/- 57.7, 585.9 +/- 82.4, and 782.33 +/- 269.4 mm, respectively). There was negligible to moderate levels of association between insertion torque and lateral displacement in the Blossomt, fluted and non-fluted design groups, respectively. Conclusion: Insertion torque was reduced in implant macrodesigns that incorporated cutting edges, and lesser insertion torque was generally associated with decreased micromovement. However, insertion torque and micromotion were unrelated within implant designs, particularly for those designs showing the least insertion torque.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

von Walden F, Casagrande V, Ostlund Farrants AK, Nader GA. Mechanical loading induces the expression of a Pol I regulon at the onset of skeletal muscle hypertrophy. Am J Physiol Cell Physiol 302: C1523-C1530, 2012. First published March 7, 2012; doi:10.1152/ajpcell.00460.2011.-The main goal of the present study was to investigate the regulation of ribosomal DNA (rDNA) gene transcription at the onset of skeletal muscle hypertrophy. Mice were subjected to functional overload of the plantaris by bilateral removal of the synergist muscles. Mechanical loading resulted in muscle hypertrophy with an increase in rRNA content. rDNA transcription, as determined by 45S pre-rRNA abundance, paralleled the increase in rRNA content and was consistent with the onset of the hypertrophic response. Increased transcription and protein expression of c-Myc and its downstream polymerase I (Pol I) regulon (POL1RB, TIF-1A, PAF53, TTF1, TAF1C) was also consistent with the increase in rRNA. Similarly, factors involved in rDNA transcription, such as the upstream binding factor and the Williams syndrome transcription factor, were induced by mechanical loading in a corresponding temporal fashion. Chromatin immunoprecipitation revealed that these factors, together with Pol I, were enriched at the rDNA promoter. This, in addition to an increase in histone H3 lysine 9 acetylation, demonstrates that mechanical loading regulates rRNA synthesis by inducing a gene expression program consisting of a Pol I regulon, together with accessory factors involved in transcription and chromatin remodeling at the rDNA promoter. Altogether, these data indicate that transcriptional and epigenetic mechanisms take place in the regulation of ribosome production at the onset of muscle hypertrophy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Previous studies indicate that flexible footwear, which mimics the biomechanics of walking barefoot, results in decreased knee loads in patients with knee osteoarthritis (OA) during walking. However, the effect of flexible footwear on other activities of daily living, such as descending stairs, remains unclear. Our objective was to evaluate the influence of inexpensive and minimalist footwear (Moleca) on knee adduction moment (KAM) during stair descent of elderly women with and without knee OA. Methods. Thirty-four elderly women were equally divided into an OA group and a control group (CG). Stair descent was evaluated in barefoot condition, while wearing the Moleca, and while wearing heeled shoes. Kinematics and ground reaction forces were measured to calculate KAM by using inverse dynamics. Results. The OA group experienced a higher KAM during midstance under the barefoot condition (233.3%; P = 0.028), the Moleca (379.2%; P = 0.004), and heeled shoes (217.6%; P = 0.007). The OA group had a similar knee load during early, mid, and late stance with the Moleca compared with the barefoot condition. Heeled shoes increased the knee loads during the early-stance (versus barefoot [16.7%; P < 0.001] and versus the Moleca [15.5%; P < 0.001]), midstance (versus barefoot [8.6%; P = 0.014] and versus the Moleca [9.5%; P = 0.010]), and late-stance phase (versus barefoot [10.6%; P = 0.003] and versus the Moleca [9.2%; P < 0.001]). In the CG, the Moleca produced a knee load similar to the barefoot condition only during the early-stance phase. Conclusion. Besides the general foot protection, the inexpensive and minimalist footwear contributes to decreasing knee loads in elderly women with OA during stair descent. The loads are similar to the barefoot condition and effectively decreased when compared with heeled shoes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effects of the organic loading rate (OLR) and pH buffer addition on hydrogen production in two anaerobic fluidized bed reactors (AFBRs) operated simultaneously. The AFBRs were fed with glucose, and expanded clay was used as support material. The reactors were operated at a temperature of 30 degrees C, without the addition of a buffer (AFBR1) and with the addition of a pH buffer (AFBR2, sodium bicarbonate) for OLRs ranging from 19.0 to 140.6 kg COD m(-3) d(-1) (COD: chemical oxygen demand). The maximum hydrogen yields for AFBR1 and AFBR2 were 2.45 and 1.90 mol H-2 mol(-1) glucose (OLR of 84.3 kg COD m(-3) d(-1)), respectively. The highest hydrogen production rates were 0.95 and 0.76 L h(-1) L-1 for AFBR1 and AFBR2 (OLR of 140.6 kg COD m(-3) d(-1)), respectively. The operating conditions in AFBR1 favored the presence of such bacteria as Clostridium, while the bacteria in AFBR2 included Clostridium, Enterobacter, Klebsiella, Veillonellaceae, Chryseobacterium, Sporolactobacillus, and Burkholderiaceae. Copyright (C) 2012, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of the relationship between particle size (d), inter-particle distance (x(i)), and metal loading (y) of carbon supported fuel cell Pt or PtRu catalysts on their catalytic activity, based on the optimum d (2.5-3 nm) and x(i)/d (>5) values, was evaluated. It was found that for y < 30 wt%, the optimum values of both d and x(i)/d can be always obtained. For y >= 30 wt%, instead, the positive effect of a thinner catalyst layer of the fuel cell electrode than that using catalysts with y < 30 wt% is concomitant to a decrease of the effective catalyst surface area due to an increase of d and/or a decrease of x(i)/d compared to their optimum values, with in turns gives rise to a decrease in the catalytic activity. The effect of the x(i)/d ratio has been successfully verified by experimental results on ethanol oxidation on PtRu/C catalysts with same particle size and same degree of alloying but different metal loading. Tests in direct ethanol fuel cells showed that, compared to 20 wt% PtRu/C, the negative effect of the lower x(i)/d on the catalytic activity of 30 and 40 wt% PtRu/C catalysts was superior to the positive effect of the thinner catalyst layer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Field experiments have demonstrated that piles driven into sand can respond to axial cyclic loading in Stable, Unstable or Meta-Stable ways, depending on the combinations of mean and cyclic loads and the number of cycles. An understanding of the three styles of responses is provided by experiments involving a highly instrumented model displacement pile and an array of soil stress sensors installed in fine sand in a pressurised calibration chamber. The different patterns of effective stress developing on and around the shaft are reported, along with the results of static load tests that track the effects on shaft capacity. The interpretation links these observations to the sand's stress strain behaviour. The interface-shear characteristics, the kinematic yielding, the local densification, the growth of a fractured interface-shear zone and the restrained dilatancy at the pile soil interface are all found to be important. The model tests are shown to be compatible with the full-scale behaviour and to provide key information for improving the modelling and the design rules. (C) 2012 The Japanese Geotechnical Society. Production and hosting by Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new trend in cosmetic formulations is the use of biotechnological raw materials as the polysaccharides from Klebsiella pneumoniae, which are supposed to enhance cell renewal, improve skin hydration and micro-relief. Botanical extracts of Myrtus communis leaves contain different sugars, which may provide the same benefits. Thus, the objective of this study was to evaluate through objective and subjective analysis the immediate and long-term effects of cosmetic formulations containing polysaccharides biotechnologically-originated and / or the ones contained in Myrtus communis extracts. Three polysaccharide-based and placebo formulations were applied on the forearm skin of 40 volunteers. Skin hydration, transepidermal water loss (TEWL), viscoelasticity and skin micro-relief measurements were made before and 2 hours after a single application and after 15 and 30 day-periods of daily applications. Answers to a questionnaire about perceptions of formulation cosmetic features constituted the subjective analysis. All polysaccharide-based formulations enhanced skin hydration. Formulations with isolated or combined active substances improved skin barrier function as compared to placebo, in the short and long term studies. Formulations containing Myrtus communis extracts had the highest acceptance. Results suggest that daily use of formulations containing these substances is important for protection of the skin barrier function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Metronidazole is a BCS (Biopharmaceutics Classification System) class 1 drug, traditionally considered the choice drug in the infections treatment caused by protozoa and anaerobic microorganisms. This study aimed to evaluate bioequivalence between 2 different marketed 250 mg metronidazole immediate release tablets. A randomized, open-label, 2 x 2 crossover study was performed in healthy Brazilian volunteers under fasting conditions with a 7-day washout period. The formulations were administered as single oral dose and blood was sampled over 48 h. Metronidazole plasma concentrations were determined by a liquid chromatography mass spectrometry (LC-MS/MS) method. The plasma concentration vs. time profile was generated for each volunteer and the pharmacokinetic parameters C-max, T-max, AUC(0-t), AUC(0-infinity), k(e), and t(1/2) were calculated using a noncompartmental model. Bioequivalence between pharmaceutical formulations was determined by calculating 90% CIs (Confidence Intervall) for the ratios of C-max, AUC(0-t), and AUC(0-infinity) values for test and reference using log-transformed data. 22 healthy volunteers (11 men, 11 women; mean (SD) age, 28 (6.5) years [range, 21-45 years]; mean (SD) weight, 66 (9.3) kg [range, 51-81 kg]; mean (SD) height, 169 (6.5) cm [range, 156-186 cm]) were enrolled in and completed the study. The 90% CIs for C-max (0.92-1.06), AUC(0-t) (0.97-1.02), and AUC(0-infinity) (0.97-1.03) values for the test and reference products fitted in the interval of 0.80-1.25 proposed by most regulatory agencies, including the Brazilian agency ANVISA. No clinically significant adverse effects were reported. After pharmacokinetics analysis, it concluded that test 250 mg metronidazole formulation is bioequivalent to the reference product according to the Brazilian agency requirements.