812 resultados para INTERNAL FAULT
Resumo:
The paper is devoted to study specific aspects of heat transfer in the combustion chamber of compression ignited reciprocating internal combustion engines and possibility to directly measure the heat flux by means of Gradient Heat Flux Sensors (GHFS). A one – dimensional single zone model proposed by Kyung Tae Yun et al. and implemented with the aid of Matlab, was used to obtain approximate picture of heat flux behavior in the combustion chamber with relation to the crank angle. The model’s numerical output was compared to the experimental results. The experiment was accomplished by A. Mityakov at four stroke diesel engine Indenor XL4D. Local heat fluxes on the surface of cylinder head were measured with fast – response, high – sensitive GHFS. The comparison of numerical data with experimental results has revealed a small deviation in obtained heat flux values throughout the cycle and different behavior of heat flux curve after Top Dead Center.
Resumo:
This master’s thesis is devoted to study different heat flux measurement techniques such as differential temperature sensors, semi-infinite surface temperature methods, calorimetric sensors and gradient heat flux sensors. The possibility to use Gradient Heat Flux Sensors (GHFS) to measure heat flux in the combustion chamber of compression ignited reciprocating internal combustion engines was considered in more detail. A. Mityakov conducted an experiment, where Gradient Heat Flux Sensor was placed in four stroke diesel engine Indenor XL4D to measure heat flux in the combustion chamber. The results which were obtained from the experiment were compared with model’s numerical output. This model (a one – dimensional single zone model) was implemented with help of MathCAD and the result of this implementation is graph of heat flux in combustion chamber in relation to the crank angle. The values of heat flux throughout the cycle obtained with aid of heat flux sensor and theoretically were sufficiently similar, but not identical. Such deviation is rather common for this type of experiment.
Resumo:
The aim of this thesis research was to gain a better understanding of the emplacement of rapakivi granite intrusions, as well as the emplacement of gold-bearing hydrothermal fluids in structurally controlled mineralizations. Based on investigations of the magnetic fabric, the internal structures could be analysed and the intrusion mechanisms for rapakivi granite intrusions and respectively different deformation stages within gold-bearing shear and fault zones identified. Aeromagnetic images revealed circular structures within the rapakivi granite batholiths of Wiborg, Vehmaa and Åland. These circular structures represent intrusions that eventually build up these large batholiths. The rapakivi granite intrusions of Vehmaa, Ruotsinpyhtää within the Wiborg batholith and Saltvik intrusions within the Åland batholith all show bimodal magnetic susceptibilities with paramagnetic and ferromagnetic components. The distribution of the bimodality is related to different magma batches of the studied intrusions. The anisotropy of magnetic susceptibility (AMS) reveals internal structures that cannot be studied macroscopically or by microscope. The Ruotsinpyhtää and Vehmaa intrusions represent similar intrusion geometries, with gently to moderately outward dipping magnetic foliations. In the case of Vehmaa, the magnetic lineations are gently plunging and trend in the directions of the slightly elongated intrusion. The magnetic lineations represent magma flow. The shapes of the AMS ellipsoids are also more planar (oblate) in the central part of the intrusion, whereas they become more linear (prolate) near the margin. These AMS results, together with field observations, indicate that the main intrusion mechanism has involved the subsidence of older blocks with successive intrusion of fractionated magma during repeated cauldron subsidence. The Saltvik area within the Åland batholith consists of a number of smaller elliptical intrusions of different rapakivi types forming a multiple intrusive complex. The magnetic fabric shows a general westward dipping of the pyterlite and eastward dipping of the contiguous even-grained rapakivi granite, which indicates a central inflow of magma batches towards the east and west resulting from a laccolitic emplacement of magma batches, while the main mechanism for space creation was derived from subsidence. The magnetic fabric of structurally controlled gold potential shear and fault zones in Jokisivu, Satulinmäki and Koijärvi was investigated in order to describe the internal structures and define the deformation history and emplacement of hydrothermal fluids. A further aim of the research was to combine AMS studies with palaeomagnetic methods to constrain the timing for the shearing event relative to the precipitation of ferromagnetic minerals and gold. All of the studied formations are dominated by monoclinic pyrrhotite. The AMS directions generally follow the tectonic structures within the formations. However, internal variations in the AMS direction as well as the shapes of the AMS ellipsoids are observed within the shear zones. In Jokisivu and Satulinmäki in particular, the magnetic signatures of the shear zone core differ from the margins. Furthermore, the shape of the magnetic fabric in the shear zone core of Jokisivu is dominated by oblate shapes, whereas the margins exhibit prolate shapes. These variations indicate a later effect of the hydrothermal fluids on the general shear event. The palaeo-magnetic results reveal a deflection from the original Svecofennian age geomagnetic direction. These results, coupled with correlations between the orientation of the NRM vectors and the magnetic and rock fabrics, imply that the gold-rich hydrothermal fluids were emplaced pre/syntectonically during the late stages of the Svecofennian orogeny.
Resumo:
This bachelor's thesis is about to find out to what extent Finnish managers and small and medium sized organizations are willing and able to put employee empowerment into practice and what experiences they have got from employee empowerment as an approach towards job redesign. Some of the top enterprises in the world are known for their empowered employees as a single most important factor for their success and this thesis focuses on introducing the subject to Finnish managers and organizations to find out what benefits, barriers and other thoughts they have about the whole idea of empowered employees in Finnish organization culture. Most notable findings in this thesis are that Finnish managers do think that their organization's employees are capable to work efficiently if their job is extended and the organizations would perform better when right person's job is enriched and he/she is given more power to solve problems.
Resumo:
Erythrocytes are useful in evaluating K+ transport pathways involved in internal K+ balance. Several forms of H+,K+-ATPase have been described in nephron segments active in K+ transport. Furthermore, the activity of a ouabain-insensitive isoform of H+,K+-ATPase expressed in collecting duct cells may be modulated by acid-base status. Various assays were performed to determine if a ouabain-insensitive K+-ATPase is present in rat erythrocytes and, if so, whether it plays a role in internal K+ balance. Kinetic studies demonstrated that maximal stimulation of enzyme activity was achieved with 2.5 mM K+ at pH 7.4. Subsequent experiments were performed on erythrocyte membranes collected from animals submitted to varying degrees of K+ homeostasis: control rats, K+-depleted rats, K+-loaded rats, and rats rendered hyperkalemic due to acute renal failure. As observed in the collecting duct cell studies, there was a significant decrease in the activity of ouabain-insensitive K+-ATPase in the erythrocytes of both K+-loaded and metabolically alkalotic K+-depleted rats. However, this enzyme activity in erythrocyte membranes of rats with metabolic acidosis-related hyperkalemia was similar to that of control animals. This finding may be interpreted as resulting from two potentially modulating factors: the stimulating effect that metabolic acidosis has on K+-ATPase and the counteracting effect that hyperkalemia and uremia have on metabolic acidosis. In summary, we present evidence of a ouabain-insensitive K+-ATPase in erythrocytes, whose activity is modulated by acid-base status and K+ levels.
Resumo:
The bedrock of old crystalline cratons is characteristically saturated with brittle structures formed during successive superimposed episodes of deformation and under varying stress regimes. As a result, the crust effectively deforms through the reactivation of pre-existing structures rather than by through the activation, or generation, of new ones, and is said to be in a state of 'structural maturity'. By combining data from Olkiluoto Island, southwestern Finland, which has been investigated as the potential site of a deep geological repository for high-level nuclear waste, with observations from southern Sweden, it can be concluded that the southern part of the Svecofennian shield had already attained structural maturity during the Mesoproterozoic era. This indicates that the phase of activation of the crust, i.e. the time interval during which new fractures were generated, was brief in comparison to the subsequent reactivation phase. Structural maturity of the bedrock was also attained relatively rapidly in Namaqualand, western South Africa, after the formation of first brittle structures during Neoproterozoic time. Subsequent brittle deformation in Namaqualand was controlled by the reactivation of pre-existing strike-slip faults.In such settings, seismic events are likely to occur through reactivation of pre-existing zones that are favourably oriented with respect to prevailing stresses. In Namaqualand, this is shown for present day seismicity by slip tendency analysis, and at Olkiluoto, for a Neoproterozoic earthquake reactivating a Mesoproterozoic fault. By combining detailed field observations with the results of paleostress inversions and relative and absolute time constraints, seven distinctm superimposed paleostress regimes have been recognized in the Olkiluoto region. From oldest to youngest these are: (1) NW-SE to NNW-SSE transpression, which prevailed soon after 1.75 Ga, when the crust had sufficiently cooled down to allow brittle deformation to occur. During this phase conjugate NNW-SSE and NE-SW striking strike-slip faults were active simultaneous with reactivation of SE-dipping low-angle shear zones and foliation planes. This was followed by (2) N-S to NE-SW transpression, which caused partial reactivation of structures formed in the first event; (3) NW-SE extension during the Gothian orogeny and at the time of rapakivi magmatism and intrusion of diabase dikes; (4) NE-SW transtension that occurred between 1.60 and 1.30 Ga and which also formed the NW-SE-trending Satakunta graben located some 20 km north of Olkiluoto. Greisen-type veins also formed during this phase. (5) NE-SW compression that postdates both the formation of the 1.56 Ga rapakivi granites and 1.27 Ga olivine diabases of the region; (6) E-W transpression during the early stages of the Mesoproterozoic Sveconorwegian orogeny and which also predated (7) almost coaxial E-W extension attributed to the collapse of the Sveconorwegian orogeny. The kinematic analysis of fracture systems in crystalline bedrock also provides a robust framework for evaluating fluid-rock interaction in the brittle regime; this is essential in assessment of bedrock integrity for numerous geo-engineering applications, including groundwater management, transient or permanent CO2 storage and site investigations for permanent waste disposal. Investigations at Olkiluoto revealed that fluid flow along fractures is coupled with low normal tractions due to in-situ stresses and thus deviates from the generally accepted critically stressed fracture concept, where fluid flow is concentrated on fractures on the verge of failure. The difference is linked to the shallow conditions of Olkiluoto - due to the low differential stresses inherent at shallow depths, fracture activation and fluid flow is controlled by dilation due to low normal tractions. At deeper settings, however, fluid flow is controlled by fracture criticality caused by large differential stress, which drives shear deformation instead of dilation.
Resumo:
Leaf-cutting ants of the genera Atta and Acromyrmex (tribe Attini) are symbiotic with basidiomycete fungi of the genus Leucoagaricus (tribe Leucocoprineae), which they cultivate on vegetable matter inside their nests. We determined the variation of the 28S, 18S, and 5.8S ribosomal DNA (rDNA) gene loci and the rapidly evolving internal transcribed spacers 1 and 2 (ITS1 and ITS2) of 15 sympatric and allopatric fungi associated with colonies of 11 species of leafcutter ants living up to 2,600 km apart in Brazil. We found that the fungal rDNA and ITS sequences from different species of ants were identical (or nearly identical) to each other, whereas 10 GenBank Leucoagaricus species showed higher ITS variation. Our findings suggest that Atta and Acromyrmex leafcutters living in geographic sites that are very distant from each other cultivate a single fungal species made up of closely related lineages of Leucoagaricus gongylophorus. We discuss the strikingly high similarity in the ITS1 and ITS2 regions of the Atta and Acromyrmex symbiotic L. gongylophorus studied by us, in contrast to the lower similarity displayed by their non-symbiotic counterparts. We suggest that the similarity of our L. gongylophorus isolates is an indication of the recent association of the fungus with these ants, and propose that both the intense lateral transmission of fungal material within leafcutter nests and the selection of more adapted fungal strains are involved in the homogenization of the symbiotic fungal stock.
Resumo:
This thesis is made in cooperation with Laboratory of Steel Structures and the steel company SSAB. Maximization of the benefits of high-strength steel usually requires the usage of thin wall thicknesses. This means the failures related to buckling, distortion and warping stand out. One must be aware of these phenomena to design thin-walled structures stressed with forces such as torsional loading. It is also important to take into account small stress ranges when evaluating the accurate fatigue strength of structures. The objective of this thesis is to clarify the theory of the uniform and non-uniform torsion. This paper focuses on warping due to the non-uniform torsion in double symmetric box girder and structural hollow section. The arisen stress states are explained and researched using the finite element method. Another research target is the distortion in double symmetric box girder due to torsion, and the restraining effect of transverse diaphragms at the load end. Multiple transverse diaphragms are used to study more efficient restraining against warping and distortion than a common one end plate structure.
Resumo:
This thesis studies the advantages, disadvantages and possibilities of additive manufacturing in making components with internal flow channels. These include hydraulic components, components with cooling channels and heat exchangers. Processes studied in this work are selective laser sintering and selective laser melting of metallic materials. The basic principles of processes and parameters involved in the process are presented and different possibilities of internal channel manufacturing and flow improvement are introduced
Resumo:
The aim of this Master’s Thesis is to find applicable methods from process management literature for improving reporting and internal control in a multinational corporation. The method of analysis is qualitative and the research is conducted as a case study. Empirical data collection is carried out through interviews and participating observation. The theoretical framework is built around reporting and guidance between parent company and subsidiary, searching for means to improve them from process thinking and applicable frameworks. In the thesis, the process of intercompany reporting in the case company is modelled, and its weak points, risks, and development targets are identified. The framework of critical success factors in process improvement is utilized in assessing the development targets. Also internal control is analyzed with the tools of process thinking. As a result of this thesis, suggestions for actions improving the reporting process and internal control are made to the case company, the most essential of which are ensuring top management’s awareness and commitment to improvement, creating guidelines and tools for internal control and creating and implementing improved intercompany reporting process.
Resumo:
The aim of this study was to explore the clinical efficacy of a novel retrograde puncture approach to establish a preperitoneal space for laparoscopic direct inguinal hernia repair with inguinal ring suturing. Forty-two patients who underwent laparoscopic inguinal hernia repair with retrograde puncture for preperitoneal space establishment as well as inguinal ring suturing between August 2013 and March 2014 at our hospital were enrolled. Preperitoneal space was successfully established in all patients, with a mean establishment time of 6 min. Laparoscopic repairs were successful in all patients, with a mean surgical time of 26±15.1 min. Mean postoperative hospitalization duration was 3.0±0.7 days. Two patients suffered from postoperative local hematomas, which were relieved after puncturing and drainage. Four patients had short-term local pain. There were no cases of chronic pain. Patients were followed up for 6 months to 1 year, and no recurrence was observed. Our results demonstrate that preperitoneal space established by the retrograde puncture technique can be successfully used in adult laparoscopic hernioplasty to avoid intraoperative mesh fixation, and thus reduce medical costs.
Resumo:
Recent Storms in Nordic countries were a reason of long power outages in huge territories. After these disasters distribution networks' operators faced with a problem how to provide adequate quality of supply in such situation. The decision of utilization cable lines rather than overhead lines were made, which brings new features to distribution networks. The main idea of this work is a complex analysis of medium voltage distribution networks with long cable lines. High value of cable’s specific capacitance and length of lines determine such problems as: high values of earth fault currents, excessive amount of reactive power flow from distribution to transmission network, possibility of a high voltage level at the receiving end of cable feeders. However the core tasks was to estimate functional ability of the earth fault protection and the possibility to utilize simplified formulas for operating setting calculations in this network. In order to provide justify solution or evaluation of mentioned above problems corresponding calculations were made and in order to analyze behavior of relay protection principles PSCAD model of the examined network have been created. Evaluation of the voltage rise in the end of a cable line have educed absence of a dangerous increase in a voltage level, while excessive value of reactive power can be a reason of final penalty according to the Finish regulations. It was proved and calculated that for this networks compensation of earth fault currents should be implemented. In PSCAD models of the electrical grid with isolated neutral, central compensation and hybrid compensation were created. For the network with hybrid compensation methodology which allows to select number and rated power of distributed arc suppression coils have been offered. Based on the obtained results from experiments it was determined that in order to guarantee selective and reliable operation of the relay protection should be utilized hybrid compensation with connection of high-ohmic resistor. Directional and admittance based relay protection were tested under these conditions and advantageous of the novel protection were revealed. However, for electrical grids with extensive cabling necessity of a complex approach to the relay protection were explained and illustrated. Thus, in order to organize reliable earth fault protection is recommended to utilize both intermittent and conventional relay protection with operational settings calculated by the use of simplified formulas.