974 resultados para INCISIONAL HERNIA REPAIR
Resumo:
One case of transdiafragmatic intercostal hernia after intense coughing fit followed by rib fractures in patient with history of pneumonia is presented. He had a severe coughing fit, developed a right toracoabdominal hematoma and then a tumor that was gradually enlarging. Image exams confirmed the diagnosis. Treatment consisted of surgical repair with the use of a polypropylene prosthetic mesh. It is a rare type of hernia. Only four cases were found in literature. The sooner the disease is diagnosed and treated the better the prognoses will be since it will prevent hernia from strangulation and incarceration.
Resumo:
Petit's lumbar hernia is an uncommon defect of the posterior abdominal wall that represents less than 1% of all abdominal wall hernias. It is more often unilateral and founded in young females, rarely containing a real herniated sac. There are two different approaches to repair: laparoscopy and open surgery. The goal of this article is to report one case of spontaneous bilateral lumbar Petit's hernia treated with open surgery.
Resumo:
O achado de ossificação heterotópica (OH) sobre cicatriz cirúrgica abdominal é um evento raro, mas que soma morbidade ao paciente. Manifesta-se por dor, endurecimento ou desconforto na cicatriz, levando a novas abordagens cirúrgicas. Relatamos um caso de OH no saco herniário incisional com o objetivo precípuo de chamar a atenção para o potencial "totipotente" do fibroblasto, já que sua íntima relação com a OH é inegável. A partir dessa prerrogativa, qualquer forma de tratamento das hérnias incisionais deveria associar o reparo tecidual ao uso de prótese (tela), para enriquecê-lo com os fibroblastos e seus fatores de crescimento celular do próprio paciente, todos autólogos e prontos para uso. A tática é oferecer uma abordagem combinada ou mista, com menores chances de recidiva na correção dessas afecções.
Resumo:
OBJECTIVE: to evaluate the role of fibrillar extracellular matrix components in the pathogenesis of inguinal hernias. METHODS: samples of the transverse fascia and of the anterior sheath of the rectus abdominis muscle were collected from 40 men aged between 20 and 60 years with type II and IIIA Nyhus inguinal hernia and from 10 fresh male cadavers (controls) without hernia in the same age range. The staining technique was immunohistochemistry for collagen I, collagen III and elastic fibers; quantification of fibrillar components was performed with an image analysis processing software. RESULTS: no statistically significant differences were found in the amount of elastic fibers, collagen I and collagen III, and the ratio of collagen I / III among patients with inguinal hernia when compared with subjects without hernia. CONCLUSION: the amount of fibrillar extracellular matrix components did not change in patients with and without inguinal hernia.
Resumo:
OBJECTIVE: To standardize a technique for ventilating rat fetuses with Congenital Diaphragmatic Hernia (CDH) using a volume-controlled ventilator.METHODS: Pregnant rats were divided into the following groups: a) control (C); b) exposed to nitrofen with CDH (CDH); and c) exposed to nitrofen without CDH (N-). Fetuses of the three groups were randomly divided into the subgroups ventilated (V) and non-ventilated (N-V). Fetuses were collected on day 21.5 of gestation, weighed and ventilated for 30 minutes using a volume-controlled ventilator. Then the lungs were collected for histological study. We evaluated: body weight (BW), total lung weight (TLW), left lung weight (LLW), ratios TLW / BW and LLW / BW, morphological histology of the airways and causes of failures of ventilation.RESULTS: BW, TLW, LLW, TLW / BW and LLW / BW were higher in C compared with N- (p <0.05) and CDH (p <0.05), but no differences were found between the subgroups V and N-V (p> 0.05). The morphology of the pulmonary airways showed hypoplasia in groups N- and CDH, with no difference between V and N-V (p <0.05). The C and N- groups could be successfully ventilated using a tidal volume of 75 ìl, but the failure of ventilation in the CDH group decreased only when ventilated with 50 ìl.CONCLUSION: Volume ventilation is possible in rats with CDH for a short period and does not alter fetal or lung morphology.
Resumo:
Objective: To evaluate the effectiveness and safety of correction of pectus excavatum by the Nuss technique based on the available scientific evidence.Methods: We conducted an evidence synthesis following systematic processes of search, selection, extraction and critical appraisal. Outcomes were classified by importance and had their quality assessed by the Grading of Recommendations Assessment, Development and Evaluation (GRADE).Results: The process of selection of items led to the inclusion of only one systematic review, which synthesized the results of nine observational studies comparing the Nuss and Ravitch procedures. The evidence found was rated as poor and very poor quality. The Nuss procedure has increased the incidence of hemothorax (RR = 5.15; 95% CI: 1.07; 24.89), pneumothorax (RR = 5.26; 95% CI: 1.55; 17.92) and the need for reintervention (RR = 4.88; 95% CI: 2.41; 9.88) when compared to the Ravitch. There was no statistical difference between the two procedures in outcomes: general complications, blood transfusion, hospital stay and time to ambulation. The Nuss operation was faster than the Ravitch (mean difference [MD] = -69.94 minutes, 95% CI: -139.04, -0.83).Conclusion: In the absence of well-designed prospective studies to clarify the evidence, especially in terms of aesthetics and quality of life, surgical indication should be individualized and the choice of the technique based on patient preference and experience of the team.
Resumo:
OBJECTIVE: to present our experience with scheduled reoperations in 15 patients with intra-abdominal sepsis. METHODS: we have applied a more effective technique consisting of temporary abdominal closure with a nylon mesh sheet containing a zipper. We performed reoperations in the operating room under general anesthesia at an average interval of 84 hours. The revision consisted of debridement of necrotic material and vigorous lavage of the involved peritoneal area. The mean age of patients was 38.7 years (range, 15 to 72 years); 11 patients were male, and four were female. RESULTS: forty percent of infections were due to necrotizing pancreatitis. Sixty percent were due to perforation of the intestinal viscus secondary to inflammation, vascular occlusion or trauma. We performed a total of 48 reoperations, an average of 3.2 surgeries per patient. The mesh-zipper device was left in place for an average of 13 days. An intestinal ostomy was present adjacent to the zipper in four patients and did not present a problem for patient management. Mortality was 26.6%. No fistulas resulted from this technique. When intra-abdominal disease was under control, the mesh-zipper device was removed, and the fascia was closed in all patients. In three patients, the wound was closed primarily, and in 12 it was allowed to close by secondary intent. Two patients developed hernia; one was incisional and one was in the drain incision. CONCLUSION: the planned reoperation for manual lavage and debridement of the abdomen through a nylon mesh-zipper combination was rapid, simple, and well-tolerated. It permitted effective management of severe septic peritonitis, easy wound care and primary closure of the abdominal wall.
Resumo:
The Repair of segmental defects in load-bearing long bones is a challenging task because of the diversity of the load affecting the area; axial, bending, shearing and torsional forces all come together to test the stability/integrity of the bone. The natural biomechanical requirements for bone restorative materials include strength to withstand heavy loads, and adaptivity to conform into a biological environment without disturbing or damaging it. Fiber-reinforced composite (FRC) materials have shown promise, as metals and ceramics have been too rigid, and polymers alone are lacking in strength which is needed for restoration. The versatility of the fiber-reinforced composites also allows tailoring of the composite to meet the multitude of bone properties in the skeleton. The attachment and incorporation of a bone substitute to bone has been advanced by different surface modification methods. Most often this is achieved by the creation of surface texture, which allows bone growth, onto the substitute, creating a mechanical interlocking. Another method is to alter the chemical properties of the surface to create bonding with the bone – for example with a hydroxyapatite (HA) or a bioactive glass (BG) coating. A novel fiber-reinforced composite implant material with a porous surface was developed for bone substitution purposes in load-bearing applications. The material’s biomechanical properties were tailored with unidirectional fiber reinforcement to match the strength of cortical bone. To advance bone growth onto the material, an optimal surface porosity was created by a dissolution process, and an addition of bioactive glass to the material was explored. The effects of dissolution and orientation of the fiber reinforcement were also evaluated for bone-bonding purposes. The Biological response to the implant material was evaluated in a cell culture study to assure the safety of the materials combined. To test the material’s properties in a clinical setting, an animal model was used. A critical-size bone defect in a rabbit’s tibia was used to test the material in a load-bearing application, with short- and long-term follow-up, and a histological evaluation of the incorporation to the host bone. The biomechanical results of the study showed that the material is durable and the tailoring of the properties can be reproduced reliably. The Biological response - ex vivo - to the created surface structure favours the attachment and growth of bone cells, with the additional benefit of bioactive glass appearing on the surface. No toxic reactions to possible agents leaching from the material could be detected in the cell culture study when compared to a nontoxic control material. The mechanical interlocking was enhanced - as expected - with the porosity, whereas the reinforcing fibers protruding from the surface of the implant gave additional strength when tested in a bone-bonding model. Animal experiments verified that the material is capable of withstanding load-bearing conditions in prolonged use without breaking of the material or creating stress shielding effects to the host bone. A Histological examination verified the enhanced incorporation to host bone with an abundance of bone growth onto and over the material. This was achieved with minimal tissue reactions to a foreign body. An FRC implant with surface porosity displays potential in the field of reconstructive surgery, especially regarding large bone defects with high demands on strength and shape retention in load-bearing areas or flat bones such as facial / cranial bones. The benefits of modifying the strength of the material and adjusting the surface properties with fiber reinforcement and bone-bonding additives to meet the requirements of different bone qualities are still to be fully discovered.
Biópsia pulmonar incisional por toracoscopia paraxifoide transdiafragmática com dois portais em cães
Resumo:
As doenças respiratórias observadas na clínica médica de pequenos animais são numerosas, assim como as possibilidades diagnósticas, dentre as quais encontram-se os exames laboratoriais, os estudos radiográficos, os lavados broncoalveolares e as biópsias. Na presente pesquisa avaliaram-se os resultados da toracoscopia paraxifoide transdiafragmática para a realização de biópsia pulmonar em cães, sendo utilizados para tanto, 13 animais clinicamente sadios. Sob anestesia geral, produziu-se pneumotórax no volume de 30ml kg-1 de ar ambiente para cada hemitórax. O acesso foi obtido a partir de dois trocartes, posicionados entre o apêndice xifoide e o arco costal, os quais transfixaram o diafragma. O primeiro portal foi empregado para a passagem do endoscópio e o segundo para a utilização de pinça saca-bocado, empregada na obtenção de biópsia. Em seguida, a pinça foi removida e um dreno torácico foi posicionado através do portal. Durante os procedimentos, aferiram-se as frequências respiratória e cardíaca, a saturação de oxigênio, as pressões arterial média e venosa central e os parâmetros hemogasométricos. Os drenos foram removidos num período de até 48 horas de pós-operatório, verificando-se mínima produção de ar e/ou líquido. Concluiu-se se tratar de uma técnica rápida, segura e sem complicações trans e pós-operatórias, permitindo aquisição de material suficiente para a avaliação histológica do pulmão.
Resumo:
Factors affecting outcome after arthroscopic rotator cuff repair are unclear and there is still insufficient evidence of efficacy of any treatment modality for rotator cuff tears. The purpose of the current study was to determine in a prospective randomized multicenter trial whether there is a difference in clinical outcome between three different treatment modalities in the treatment of degenerative, atraumatic supraspinatus tendon tear in elderly patients. 180 shoulders were randomized into three treatment groups: 1) physiotherapy, 2) arthroscopic acromioplasty and physiotherapy, 3) arthroscopic rotator cuff reconstruction, acromioplasty and physiotherapy. The objective of this study was also to evaluate retrospectively the effect of trauma, the size of the rotator cuff tear, smoking habits and glenohumeral osteoarthritis on the clinical treatment outcome after arthroscopic rotator cuff repair in a consecutively prospectively collected series of patients. The patient data was gathered to the electronic database. The Constant score was used as a primary outcome measure. The follow‐up time was one year. The main finding was that operative treatment did not provide benefit over conservative regimen in elderly patients with atraumatic supraspinatus tear. Trauma did not affect on the clinical outcome and there was neither difference in the age of patients with traumatic vs. non‐traumatic rotator cuff tears. The size of the rotator cuff tear correlated significantly with the clinical results. The outcome was significantly poorer in tears with infraspinatus involvement compared to anterosuperior tears. Operatively treated rotator cuff tear patients who smoked were significantly younger than non‐smokers, and smoking was associated with poorer clinical outcome. Concomitant osteoarthritis of the glenohumeral joint was found to be a relatively common finding in supraspinatus tear patients. Osteoarthritis of the glenohumeral joint in operatively treated supraspinatus tear patients predicted poorer clinical results comparing to patients without osteoarthritis.
Resumo:
Several human genetic syndromes have long been recognized to be defective in DNA repair mechanisms. This was first discovered by Cleaver (1968), who showed that cells from patients with xeroderma pigmentosum (XP) were defective for the ability to remove ultraviolet (UV)-induced lesions from their genome. Since then, new discoveries have promoted DNA repair studies to one of the most exciting areas of molecular biology. The present work intends to give a brief summary of the main known human genetic diseases related to DNA repair and how they may be linked to acquired diseases such as cancer
Resumo:
We placed spheres of synthetic hydroxyapatite (calcium chloride combined with sodium phosphate) in the eviscerated or enucleated orbital cavity of rats in order to evaluate the biocompatibility of this material with the orbital cavity. The study was conducted on 50 albino rats, 25 of which were submitted to enucleation and 25 to evisceration of one eye. The animals were sacrificed 7, 15, 21, 30 and 60 days after surgery and the orbital content was submitted to histopathological examination. A reaction of the young granulation tissue type was observed first. The hydroxyapatite was gradually surrounded by a granulomatous macrophage inflammatory response and covered with dense connective tissue that formed a sort of" mesh" septating and supporting progressively smaller blocks of the substance. The same type of reaction was observed in the enucleated and eviscerated cavities. We conclude that synthetic hydroxyapatite is an inert nonallergenic material which is appropriate for volume replacement in the anophthalmic cavity
Resumo:
In the present study, we analyzed DNA damage induced by phycocyanin (PHY) in the presence of visible light (VL) using a set of repair endonucleases purified from Escherichia coli. We demonstrated that the profile of DNA damage induced by PHY is clearly different from that induced by molecules that exert deleterious effects on DNA involving solely singlet oxygen as reactive species. Most of PHY-induced lesions are single strand breaks and, to a lesser extent, base oxidized sites, which are recognized by Nth, Nfo and Fpg enzymes. High pressure liquid chromatography coupled to electrochemical detection revealed that PHY photosensitization did not induce 8-oxo-7,8-dihydro-2'-deoxyguanosine (8-oxodGuo) at detectable levels. DNA repair after PHY photosensitization was also investigated. Plasmid DNA damaged by PHY photosensitization was used to transform a series of Saccharomyces cerevisiae DNA repair mutants. The results revealed that plasmid survival was greatly reduced in rad14 mutants, while the ogg1 mutation did not modify the plasmid survival when compared to that in the wild type. Furthermore, plasmid survival in the ogg1 rad14 double mutant was not different from that in the rad14 single mutant. The results reported here indicate that lethal lesions induced by PHY plus VL are repaired differently by prokaryotic and eukaryotic cells. Morever, nucleotide excision repair seems to play a major role in the recognition and repair of these lesions in Saccharomyces cerevisiae.
Resumo:
Electroacupuncture has been proposed to be a low cost and practical method that allows effective pain management with minimal collateral effects. In this study we have examined the effect of electroacupuncture against the hyperalgesia developed in a model of post-incisional pain in rats. A 1-cm longitudinal incision was made through the skin and fascia of the plantar region of the animal hind paw. Mechanical hyperalgesia in the incision was evaluated 135 min after the surgery with von Frey filaments. The tension threshold was reduced from 75 g (upper limit of the test) to 1.36 ± 0.36 g (mean ± SEM) in control rats. It is shown that a 15-min period of electroacupuncture applied 120 min after surgery to the Zusanli (ST36) and Sanyinjiao (SP6) points, but not to non-acupoints, produces a significant and long-lasting reduction of the mechanical hyperalgesia induced by the surgical incision of the plantar surface of the ipsilateral hind paw. The tension threshold was reduced from 75 to 27.6 ± 4.2 g in animals soon after the end of electroacupuncture. The mechanical threshold in this group was about 64% less than in control. Electroacupuncture was ineffective in rats treated 10 min earlier with naloxone (1 mg/kg, ip), thus confirming the involvement of opioid mechanisms in the antinociceptive effects of such procedure. The results indicate that post-incisional pain is a useful model for studying the anti-hyperalgesic properties of electroacupuncture in laboratory animals.