782 resultados para HPLC protocol
Resumo:
R,S-sotalol, a ß-blocker drug with class III antiarrhythmic properties, is prescribed to patients with ventricular, atrial and supraventricular arrhythmias. A simple and sensitive method based on HPLC-fluorescence is described for the quantification of R,S-sotalol racemate in 500 µl of plasma. R,S-sotalol and its internal standard (atenolol) were eluted after 5.9 and 8.5 min, respectively, from a 4-micron C18 reverse-phase column using a mobile phase consisting of 80 mM KH2PO4, pH 4.6, and acetonitrile (95:5, v/v) at a flow rate of 0.5 ml/min with detection at lex = 235 nm and lem = 310 nm, respectively. This method, validated on the basis of R,S-sotalol measurements in spiked blank plasma, presented 20 ng/ml sensitivity, 20-10,000 ng/ml linearity, and 2.9 and 4.8% intra- and interassay precision, respectively. Plasma sotalol concentrations were determined by applying this method to investigate five high-risk patients with atrial fibrillation admitted to the Emergency Service of the Medical School Hospital, who received sotalol, 160 mg po, as loading dose. Blood samples were collected from a peripheral vein at zero, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 6.0, 8.0, 12.0 and 24.0 h after drug administration. A two-compartment open model was applied. Data obtained, expressed as mean, were: CMAX = 1230 ng/ml, TMAX = 1.8 h, AUCT = 10645 ng h-1 ml-1, Kab = 1.23 h-1, a = 0.95 h-1, ß = 0.09 h-1, t(1/2)ß = 7.8 h, ClT/F = 3.94 ml min-1 kg-1, and Vd/F = 2.53 l/kg. A good systemic availability and a fast absorption were obtained. Drug distribution was reduced to the same extent in terms of total body clearance when patients and healthy volunteers were compared, and consequently elimination half-life remained unchanged. Thus, the method described in the present study is useful for therapeutic drug monitoring purposes, pharmacokinetic investigation and pharmacokinetic-pharmacodynamic sotalol studies in patients with tachyarrhythmias.
Resumo:
Bioanalytical data from a bioequivalence study were used to develop limited-sampling strategy (LSS) models for estimating the area under the plasma concentration versus time curve (AUC) and the peak plasma concentration (Cmax) of 4-methylaminoantipyrine (MAA), an active metabolite of dipyrone. Twelve healthy adult male volunteers received single 600 mg oral doses of dipyrone in two formulations at a 7-day interval in a randomized, crossover protocol. Plasma concentrations of MAA (N = 336), measured by HPLC, were used to develop LSS models. Linear regression analysis and a "jack-knife" validation procedure revealed that the AUC0-¥ and the Cmax of MAA can be accurately predicted (R²>0.95, bias <1.5%, precision between 3.1 and 8.3%) by LSS models based on two sampling times. Validation tests indicate that the most informative 2-point LSS models developed for one formulation provide good estimates (R²>0.85) of the AUC0-¥ or Cmax for the other formulation. LSS models based on three sampling points (1.5, 4 and 24 h), but using different coefficients for AUC0-¥ and Cmax, predicted the individual values of both parameters for the enrolled volunteers (R²>0.88, bias = -0.65 and -0.37%, precision = 4.3 and 7.4%) as well as for plasma concentration data sets generated by simulation (R²>0.88, bias = -1.9 and 8.5%, precision = 5.2 and 8.7%). Bioequivalence assessment of the dipyrone formulations based on the 90% confidence interval of log-transformed AUC0-¥ and Cmax provided similar results when either the best-estimated or the LSS-derived metrics were used.
Resumo:
A procedure is described for the rapid determination of the intra-erythrocyte concentration of 6-mercaptopurine (6-MP) and its metabolites, 6-thioguanine nucleotides (6-TGN) and 6-methylmercaptopurine (6-MMP). Erythrocytes (8 x 10(8) cells) in 350 µl Hanks solution containing 7.5 mg dithiothreitol were treated with 50 µl 70% perchloric acid. The precipitate was removed by centrifugation (13,000 g) and the supernatant hydrolyzed at 100°C for 45 min. After cooling, 100 µl was analyzed directly by HPLC using a Radialpack Resolve C18 column eluted with methanol-water (7.5:92.5, v/v) containing 100 mM triethylamine. 6-TG, 6-MP and the hydrolysis product of 6-MMP, 4-amino-5-(methylthio)carbonyl imidazole, were monitored at 342, 322 and 303 nm using a Shimadzu SPD-M10A diode array UV detector. The analytes eluted at 5.3, 6.0 and 10.2 min, respectively. The calibration curves were linear (r² > 0.998), and the analytical recoveries were 73.2% for 6-TG, 119.1% for 6-MP and 97.4% for 6-MMP. The intra- and inter-assay variations were highest for 6-MP (9.6 and 14.3%, respectively). The lowest detectable concentrations were 3, 3 and 25 pmol/8 x 10(8) erythrocytes for 6-TG, 6-MP and 6-MMP, respectively. The quantification limits (coefficients of variation <15%) were 8, 10 and 70 pmol/8 x 10(8) erythrocytes for 6-TG, 6-MP and 6-MMP, respectively. The method was applied to the analysis of 183 samples from 36 children under chemotherapy for acute lymphoblastic leukemia. The concentrations of the metabolites in the red cells of the patients ranged from 0 to 1934 pmol/8 x 10(8) erythrocytes for 6-TGN, and from 0 to 105.8 and 0 to 45.9 nmol/8 x 10(8) erythrocytes for 6-MP and 6-MMP, respectively. The procedure gave results that were in agreement with those obtained with other methods designed to detect cases of non-compliance with treatment, including patient interviews and medical evaluation, among others, demonstrating its applicability to monitoring the treatment of leukemic children.
Resumo:
We studied the effects of ethanol on concentrations of noradrenaline (NE), dopamine (DA) and serotonin (5-HT) and their metabolites in rat hippocampus and striatum. Ethanol (2 or 4 g/kg, po, from a 20% aqueous solution) was administered daily to male Wistar rats (4-13 per group) for 30 days and animals were sacrificed 30 min or 48 h after the last administration. Monoamines were measured by HPLC and considered significant at P < 0.05. A 47% increase in 5-HT levels was observed in the hippocampus with 4 g/kg ethanol in the 30-min protocol. Ethanol (2 and 4 g/kg) decreased DA (2114.5 ± 126.4 and 1785.1 ± 234.2 ng/g wet tissue, respectively) and 3,4-dihydroxyphenylacetic acid (DOPAC, 1477.6 ± 132.1 and 1218.8 ± 271.7 ng/g wet tissue, respectively) levels, while the higher dose also decreased NE (159.8 ± 13.5), 5-HT (228.0 ± 46.8) and 5-hydroxy-3-indoleacetic acid (5-HIAA, 304.4 ± 37.2 ng/g wet tissue), in the striatum after a 48-h withdrawal as compared to controls (DA: 3063.9 ± 321.3; DOPAC: 2379.6 ± 256.0; NE: 292.8 ± 50.2; 5-HT: 412.4 ± 36.2; 5-HIAA: 703.9 ± 61.4 ng/g wet tissue). In the 30-min protocol, ethanol (2 or 4 g/kg) decreased striatal NE (66 and 70%) and DA (50 and 36%) levels. On the other hand, increases were seen in 5-HIAA (146 and 153%) and 5-HT (59 and 86%) levels. Ethanol (2 g/kg, po) increased the homovanillic acid (HVA)/DA ratio (129%) in the striatum in the 30-min protocol, while at the higher dose it increased the HVA/DA ratio in the 48-h protocol (61%). These results indicate alterations in monoamines, mainly in the striatum, after chronic ethanol, which are influenced by dose and by the length of time after the last drug administration.
Resumo:
Permanent bilateral occlusion of the common carotid arteries (2VO) in the rat has been established as a valid experimental model to investigate the effects of chronic cerebral hypoperfusion on cognitive function and neurodegenerative processes. Our aim was to compare the cognitive and morphological outcomes following the standard 2VO procedure, in which there is concomitant artery ligation, with those of a modified protocol, with a 1-week interval between artery occlusions to avoid an abrupt reduction of cerebral blood flow, as assessed by animal performance in the water maze and damage extension to the hippocampus and striatum. Male Wistar rats (N = 47) aged 3 months were subjected to chronic hypoperfusion by permanent bilateral ligation of the common carotid arteries using either the standard or the modified protocol, with the right carotid being the first to be occluded. Three months after the surgical procedure, rat performance in the water maze was assessed to investigate long-term effects on spatial learning and memory and their brains were processed in order to estimate hippocampal volume and striatal area. Both groups of hypoperfused rats showed deficits in reference (F(8,172) = 7.0951, P < 0.00001) and working spatial memory [2nd (F(2,44) = 7.6884, P < 0.001), 3rd (F(2,44) = 21.481, P < 0.00001) and 4th trials (F(2,44) = 28.620, P < 0.0001)]; however, no evidence of tissue atrophy was found in the brain structures studied. Despite similar behavioral and morphological outcomes, the rats submitted to the modified protocol showed a significant increase in survival rate, during the 3 months of the experiment (P < 0.02).
Resumo:
The Caco-2 cell line has been used as a model to predict the in vitro permeability of the human intestinal barrier. The predictive potential of the assay relies on an appropriate in-house validation of the method. The objective of the present study was to develop a single HPLC-UV method for the identification and quantitation of marker drugs and to determine the suitability of the Caco-2 cell permeability assay. A simple chromatographic method was developed for the simultaneous determination of both passively (propranolol, carbamazepine, acyclovir, and hydrochlorothiazide) and actively transported drugs (vinblastine and verapamil). Separation was achieved on a C18 column with step-gradient elution (acetonitrile and aqueous solution of ammonium acetate, pH 3.0) at a flow rate of 1.0 mL/min and UV detection at 275 nm during the total run time of 35 min. The method was validated and found to be specific, linear, precise, and accurate. This chromatographic system can be readily used on a routine basis and its utilization can be extended to other permeability models. The results obtained in the Caco-2 bi-directional transport experiments confirmed the validity of the assay, given that high and low permeability profiles were identified, and P-glycoprotein functionality was established.
Resumo:
Due to differences in study populations and protocols, the hemodynamic determinants of post-aerobic exercise hypotension (PAEH) are controversial. This review analyzed the factors that might influence PAEH hemodynamic determinants, through a search on PubMed using the following key words: “postexercise” or “post-exercise” combined with “hypotension”, “blood pressure”, “cardiac output”, and “peripheral vascular resistance”, and “aerobic exercise” combined only with “blood pressure”. Forty-seven studies were selected, and the following characteristics were analyzed: age, gender, training status, body mass index status, blood pressure status, exercise intensity, duration and mode (continuous or interval), time of day, and recovery position. Data analysis showed that 1) most postexercise hypotension cases are due to a reduction in systemic vascular resistance; 2) age, body mass index, and blood pressure status influence postexercise hemodynamics, favoring cardiac output decrease in elderly, overweight, and hypertensive subjects; 3) gender and training status do not have an isolated influence; 4) exercise duration, intensity, and mode also do not affect postexercise hemodynamics; 5) time of day might have an influence, but more data are needed; and 6) recovery in the supine position facilitates systemic vascular resistance decrease. In conclusion, many factors may influence postexercise hypotension hemodynamics, and future studies should directly address these specific influences because different combinations may explain the observed variability in postexercise hemodynamic studies.
Resumo:
Lophius gastrophysus has important commercial value in Brazil particularly for foreign trade. In this study, we described the optimization of Random Amplified Polymorphic DNA (RAPD) protocol for identification of L. gastrophysus. Different conditions (annealing temperatures, MgCl concentrations, DNA quantity) were tested to find reproducible and adequate profiles. Amplifications performed with primers A01, ² A02 and A03 generate the best RAPD profiles when the conditions were annealing temperature of 36ºC, 25 ng of DNA quantity and 2.5 mM MgCl2. Exact identification of the species and origin of marine products is necessary and RAPD could be used as an accurate, rapid tool to expose commercial fraud.
Resumo:
Tea has been considered a medicine and a healthy beverage since ancient times, but recently it has received a great deal of attention because of its antioxidant properties. Green tea polyphenols have demonstrated to be an effective chemopreventive agent. Recently, investigators have found that EGCG, one of the green tea catechins, could have anti-HIV effects when bound to CD4 receptor. Many factors can constitute important influences on the composition of tea, such as species, season, age of the leaf, climate, and horticultural practices (soil, water, minerals, fertilizers). This paper presents an HPLC analytical methodology development, using column RP-18 and mobile phase composed by water, acetonitrile, methanol, ethyl acetate, glacial acetic acid (89:6:1:3:1 v/v/v/v/v) for simultaneous determination and quantification of caffeine (CAF), catechin (C), epicatechin (EC) and epigallocatechin gallate (EGCG) in samples of Camellia sinensis (green tea) grown in Brazil and harvested in spring, in summer and in autumn, in comparison to Brazilian black tea, to samples of Japanese and Chinese green tea and to two standardized dry extracts of green tea. The method has been statistically evaluated and has proved to be adequate to qualitative and quantitative determination of the samples.
Resumo:
Availability of analytical standards is a critical aspect in developing methods for quantitative analysis of anthocyanins. The anthocyanins cyanidin-3-O-glucoside and cyanidin-3-O-rutinoside were isolated from samples of freeze-dried açaí (Euterpe oleraceae Mart.), which is a round and purple well-known palm fruit in Brazil, and then used as standards. The isolation of the anthocyanins was performed by High Performance Liquid Chromatography (HPLC), using an adapted six-channel selection valve. The identification of anthocyanin pigments in açaí was based on mass spectrometric data for molecular ions and MS-MS product ions and on previous published data. After the collection procedure, standards with a high purity grade were obtained and an external standard curve of each anthocyanin was plotted.
Resumo:
The sugars in apple juice prove its authenticity and its sensory and nutritional properties. The aim of this study was to develop and validate a simple analytical method using high performance liquid chromatography with refractive index detection (HPLC-RI) to determinate and quantify the sugars sucrose, D-glucose, D-fructose, and D-sorbitol polyol in apple juices, as well as to analyze the juices from the Fuji suprema and Lis Gala cultivars at three ripening stages. The analytical performance parameters evaluated indicated that the method was specific for the compounds analyzed, and the linearity of the calibration curves of sugars showed high correlation coefficients (close to 1.0). The limits of detection and quantification are consistent with recommendations available in the literature for this type of matrix. Sample preparation is simple and generates small amount of residues. Over 70% of the sugars were determined in the juices of apples at the pre-ripe stage, with an increase during senescence. This method is applicable for the determination of sugars in juices and evaluation of apple ripening.
Resumo:
Validation ofan Ice Skating Protocol to Predict Aerobic Power in Hockey Players In assessing the physiological capacity of ice hockey players, researchers have often reported the outcomes from different anaerobic skate tests, and the general physical fitness of participants. However, with respect to measuring the aerobic power of ice hockey players, few studies have reported a sport-specific protocol, and currently there is a lack of cohort-specific information describing aerobic power based on evaluations using an on-ice protocol. The Faught Aerobic Skating Test (FAST) uses an on-ice continuous skating protocol to induce a physical stress on a participant's aerobic energy system. The FAST incorporates the principle of increasing workloads at measured time intervals during a continuous skating exercise. Regression analysis was used to determine the estimate of aerobic power within gender and age level. Data were collected on 532 hockey players, (males=384, females=148) ranging in age between 9 and 25 years. Participants completed a laboratory test to measure aerobic power using a modified Bruce protocol, and the on-ice FAST. Regression equations were developed for six male and female, age-specific cohorts separately. The most consistent predictors were weight and final stage completed on the FAST. These results support the application of the FAST to estimate aerobic power among hockey players with R^ values ranging from 0.174 to 0.396 and SEE ranging from 5.65 to 8.58 ml kg' min'' depending on the cohort. Thus we conclude that FAST to be an accurate predictor of aerobic power in age and gender-specific hockey playing cohorts.
Resumo:
A simple High Performance Liquid Chromatograph (HPLC) method has been developed to identify benamyl (methyl 1- (butylcarbamoyl)-2-benzimidazole carbamate) and MBC (methyl 2-benzimidazole carbamat~ residues on apple leaves without cleanup. Sample leaves are freeze dried in a Mason jar and residues are then extracted by tumbling them in chloroform containing 5,000 microgram per milliliter of n-propyl isocyanate (PIC) at 10 C. To the extract, n-butyl isocyanate (BIC) was added at 5,000 microgram per milliliter and 20 microliter of this mixture injected onto the HPLC system. Separation is accomplished by the use of a Brownlee LiChrosorb silica gel column with a guard column and' operated with a mixed mobile phase consisting of chloroform and hexane (4:1) saturated with water. MBC, a degradation product of benomyl is identified if present as methyl l-(npropyl carbamoyl)-2-benzimidazole carbamate (MBC-n-PIC). Both benomyl and MBC-n-PIC can be detected with aKUltraviolet (UV) detector (280nm) at a concentration as low as 0.2 microgram per milliliter in apple leaves. The fate of benomyl on apple foliage after spray application of benomyl (Ben late 50 per cent wettable powder) was investigated by the method thus described. Benomyl quickly dissipated during the first 3-7 days, but the dissipatio'n sltowed down thereafter. In contrast, the concentration of MBC in leaves gradually increased after repeated applications of Benlate.
Resumo:
The effects of sample solvent composition and the injection volume, on the chromatographic peak profiles of two carbamate derivatives, methyl 2-benzimidazolecarbamate (MBC) and 3-butyl-2,4-dioxo[1,2-a]-s-triazinobenzimidazole (STB), were studied using reverse phase high performance liquid chromatograph. The study examined the effects of acetonitrile percentage in the sample solvent from 5 to 50%, effects of methanol percentage from 5 to 50%, effects of pH increase from 4.42 to 9.10, and effect of increasing buffer concentration from ° to 0.12M. The effects were studied at constant and increasing injection mass and at four injection volumes of 10, 50, 100 and 200 uL. The study demonstrated that the amount and the type of the organic solvents, the pH, and the buffer strength of the sample solution can have a pronounced effect on the peak heights, peak widths, and retention times of compounds analysed. MBC, which is capable of intramolecular hydrogen bonding and has no tendency to ionize, showed a predictable increase .in band broadening and a decrease in retention times at higher eluting strengths of the sample solvent. STB, which has a tendency to ionize or to strongly interact with the sample solvent, was influenced in various ways by the changes in ths sample solvent composition. The sample solvent effects became more pronounced as the injection volume increased and as the percentage of organic solvent in the sample solution became greater. The peak height increases for STB at increasing buffer concentrations became much more pronounced at higher analyte concentrations. It was shown that the widely accepted procedure of dissolving samples in the mobile phase does not yield the most efficient chromatograms. For that reason samples should be dissolved in the solutions with higher aqueous content than that of the mobile phase whenever possible. The results strongly recommend that all the samples and standards, regardless whether the standards are external or internal, be analysed at a constant sample composition and a constant injection volume.
Resumo:
In 2003, prostate cancer (PCa) is estimated to be the most commonly diagnosed cancer and third leading cause of cancer death in Canada. During PCa population screening, approximately 25% of patients with a normal digital rectal examination (DRE) and intermediate serum prostate specific antigen (PSA) level have PCa. Since all patients typically undergo biopsy, it is expected that approximately 75% of these procedures are unnecessary. The purpose of this study was to compare the degree of efficacy of clinical tests and algorithms in stage II screening for PCa while preventing unnecessary biopsies from occurring. The sample consisted of 201 consecutive men who were suspected of PCa based on the results of a DRE and serum PSA. These men were referred for venipuncture and transrectal ultrasound (TRUS). Clinical tests included TRUS, agespecific reference range PSA (Age-PSA), prostate specific antigen density (PSAD), and free-to-total prostate specific antigen ratio (%fPSA). Clinical results were evaluated individually and within algorithms. Cutoffs of 0.12 and 0.15 ng/ml/cc were employed for PSAD. Cutoffs that would provide a minimum sensitivity of 0.90 and 0.95, respectively were utilized for %fPSA. Statistical analysis included ROC curve analysis, calculated sensitivity (Sens), specificity (Spec), and positive likelihood ratio (LR), with corresponding confidence intervals (Cl). The %fPSA, at a 23% cutoff ({ Sens=0.92; CI, 0.06}, {Spec=0.4l; CI, 0.09}, {LR=1.56; CI, O.ll}), proved to be the most efficacious independent clinical test. The combination of PSAD (cutoff 0.15 ng/ml/cc) and %fPSA (cutoff 23%) ({Sens=0.93; CI, 0.06}, {Spec=0.38; CI, 0.08}, {LR=1.50; CI, 0.10}) was the most efficacious clinical algorithm. This study advocates the use of %fPSA at a cutoff of 23% when screening patients with an intermediate serum PSA and benign DRE.