996 resultados para HEAT CURRENT
Resumo:
Pultrusion is an industrial process used to produce glass fibers reinforced polymers profiles. These materials are worldwide used when performing characteristics, such as great electrical and magnetic insulation, high strength to weight ratio, corrosion and weather resistance, long service life and minimal maintenance are required. In this study, we present the results of the modelling and simulation of heat flow through a pultrusion die by means of Finite Element Analysis (FEA). The numerical simulation was calibrated based on temperature profiles computed from thermographic measurements carried out during pultrusion manufacturing process. Obtained results have shown a maximum deviation of 7%, which is considered to be acceptable for this type of analysis, and is below to the 10% value, previously specified as maximum deviation. © 2011, Advanced Engineering Solutions.
Resumo:
Based on the paper presented at the International Conference “Autonomous Systems: inter-relations of technical and societal issues”, organized by IET with the support of the Portuguese-German collaboration project on “Technology Assessment of Autonomous Robotics” (DAAD/CRUP) at FCT-UNL, Biblioteca da UNL, Campus de Caparica on 5-6 November 2009.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Electrotécnica e Computadores
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
Several popular Ansatze of lepton mass matrices that contain texture zeros are confronted with current neutrino observational data. We perform a systematic chi(2) analysis in a wide class of schemes, considering arbitrary Hermitian charged-lepton mass matrices and symmetric mass matrices for Majorana neutrinos or Hermitian mass matrices for Dirac neutrinos. Our study reveals that several patterns are still consistent with all the observations at the 68.27% confidence level, while some others are disfavored or excluded by the experimental data. The well-known Frampton-Glashow-Marfatia two-zero textures, hybrid textures, and parallel structures (among others) are considered.
Resumo:
The Fast Field-Cycling Nuclear Magnetic Resonance (FFC-NMR) is a technique used to study the molecular dynamics of different types of materials. The main elements of this equipment are a magnet and its power supply. The magnet used as reference in this work is basically a ferromagnetic core with two sets of coils and an air-gap where the materials' sample is placed. The power supply should supply the magnet being the magnet current controlled in order to perform cycles. One of the technical issues of this type of solution is the compensation of the non-linearities associated to the magnetic characteristic of the magnet and to parasitic magnetic fields. To overcome this problem, this paper describes and discusses a solution for the FFC-NMR power supply based on a four quadrant DC/DC converter.
Resumo:
Mestrado em Engenharia Química – Ramo Optimização Energética na Indústria Química
Resumo:
Esta dissertação teve como objetivo fundamental a otimização energética do sistema de refrigeração da máquina de impregnar tela ZELL e, como objetivo adicional, a avaliação da qualidade da água do circuito, justificada pela acentuada degradação dos rolos devido à corrosão provocada pela recirculação da água de arrefecimento. Inicialmente fez-se o levantamento de informações do processo produtivo para caracterizar o funcionamento do sistema de refrigeração, tendo-se selecionado duas telas de poliéster designadas neste estudo por P1 e P2 e, também, uma tela de nylon designada por N. Foram efetuados ensaios, um para cada tela, para a atual temperatura de setpoint da água à saída da torre de arrefecimento (30ºC). Realizou-se outro ensaio para a tela N mas com uma temperatura de setpoint de 37ºC, ao qual se chamou N37. Deste modo, determinou-se as potências térmicas removidas pela água de refrigeração e as potências térmicas perdidas por radiação e por convecção, tendo-se verificado que na generalidade dos rolos as referências P1 e P2 apresentam valores mais elevados. Em termos percentuais, a potência térmica removida pela água de refrigeração nos grupos tratores 1 e 3 e no conjunto de rolos de R1 a R29 corresponde a 48%, 10% e 70%, respetivamente. Com a avaliação às necessidades de arrefecimento da máquina ZELL, confirmou-se que os caudais atuais de refrigeração dos rolos garantem condições, mais que suficientes, de funcionamento dos rolamentos. Assim sendo, fez-se uma análise no sentido da diminuição do caudal total que passou de 10,25 L/s para 7,65 L/s. Considerando esta redução, determinou-se o caudal de ar húmido a ser introduzido na torre de arrefecimento. O valor determinado foi de 4,6 m3ar húmido/s, o que corresponde a uma redução de cerca de 32% em relação ao caudal atual que é de 6,8 m3ar húmido/s. Com os resultados das análises efetuadas à água do circuito de refrigeração, concluiu-se que a água de reposição e a água de recirculação possuem má qualidade para uso na generalidade dos sistemas de refrigeração, principalmente devido aos elevados valores de concentração de ferro e condutividade elétrica, responsáveis pela intensificação da corrosão no interior dos rolos.
Resumo:
Dissertation presented to obtain the Ph.D. degree in Biochemistry
Resumo:
Dissertação apresentada para a obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
Diabetes mellitus (DM) is a global epidemic, and diabetic foot ulcer (DFU) is one of its most serious and costly complications. DFUs result from a complex interaction of a number of risk factors. Once the protective layer of skin is broken, deep tissues are exposed to bacterial infection that progresses rapidly. Patients with DFUs frequently require amputations of the lower limbs and, in more than half the cases, infection is the preponderant factor. Given the challenges of treating these complex infections, this paper aims to provide a hospital-based framework for the diagnosis and treatment of diabetic foot infections (DFIs). We propose a treatment-oriented assessment of DFIs based on a cross-examination of the medical, foot, and wound history; a systemized and detailed physical examination; and the results of complementary diagnostic procedures. We stress the need for a clinical diagnosis of DFIs and the importance of microbiological evaluation for antibiotic therapy guidance. Regarding treatment, we propose a multidisciplinary approach prioritizing invasive infection drainage, necrosis debridement, and the prompt start of empirical antibiotic therapy, followed by complete and appropriate vascular reconstruction. For severe DFIs, we suggest that negative pressure wound therapy (NPWT) be included in the treatment pathway. We also provide rules for managing particular situations, such as osteomyelitis. It is our hope that this protocol will improve the hospital management of DFIs and, ultimately, the prognosis of DFI patients.
Resumo:
Chagas disease continues to be a significant public health problem, as ca. 10 million people are still infected with T. cruzi in Latin America. Decades after primary infection, 30% of individuals can develop a form of chronic inflammatory cardiomyopathy known as Chagas disease cardiomyopathy (CCC). Data from both murine models and human studies support the view that an autoimmune response as well as a parasite-driven immune response involving inflammatory cytokines and chemokines may both play a role in generating the heart lesions leading to CCC. This review aims to summarize recent advances in the understanding of the immunopathogenesis of Chagas disease cardiomyopathy.
Resumo:
Postsurgical acute suppurative parotitis is a bacterial gland infection that occurs from a few days up to some weeks after abdominal surgical procedures. In this study, the authors analyze the prevalence of this complication in Hospital das Clínicas/São Paulo University Medical School by prospectively reviewing the charts of patients who underwent surgeries performed by the gastroenterological and general surgery staff from 1980 to 2005. Diagnosis of parotitis or sialoadenitis was analyzed. Sialolithiasis and chronic parotitis previous to hospitalization were exclusion criteria. In a total of 100,679 surgeries, 256 patients were diagnosed with parotitis or sialoadenitis. Nevertheless, only three cases of acute postsurgical suppurative parotitis associated with the surgery were identified giving an incidence of 0.0028%. All patients presented with risk factors such as malnutrition, immunosuppression, prolonged immobilization and dehydration. In the past, acute postsurgical suppurative parotitis was a relatively common complication after major abdominal surgeries. Its incidence decreased as a consequence of the improvement of perioperative antibiotic therapy and postoperative support. In spite of the current low incidence, we believe it is important to identify risks and diagnose as quick as possible, in order to introduce prompt and appropriate therapeutic measures and avoid potentially fatal complications with the evolution of the disease.
Resumo:
Com a crescente sensibilização mundial relativa ao aquecimento global, provocado pela alta quantidade de emissão de gases com efeito de estufa, torna-se imperativa a redução de consumos de combustíveis fósseis e consecutivas emissões. Ao nível da construção civil, uma intervenção eficaz na prevenção de perdas de ar aquecido poderá levar a diminuições superiores a 50% na utilização de energia. Este trabalho pretende estudar a importância da eficiência energética nos edifícios, com especial enfoque na sua permeabilidade ao ar. O ensaio de porta ventiladora permite avaliar esta permeabilidade e identificar os locais onde se dão as infiltrações, nomeadamente com auxílio da câmara térmica. O principal objectivo é estudar a aplicação deste ensaio na legislação em desenvolvimento no âmbito da certificação energética, através da comparação dos resultados de quatro habitações distintas. Também ao nível da eficiência energética, será obtida a classe energética, segundo a legislação em vigor à corrente data em Portugal, de uma das habitaçãoes ensaiadas e propostas medidas de melhoria para o desempenho energético desta. Do estudo efectuado é destacado o facto de o valor de renovações horárias do ar interior de uma fracção ser sempre inferior quando obtido unicamente através da legislação em desenvolvimento, em comparação com a obtenção deste através da legislação com auxílio do ensaio da porta ventiladora, o que leva a um grande desincentivo na utilização deste.