995 resultados para Farm produce.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The farm production of silage as a winter-feed supplement is widespread. However, the bins in which silage is produced are subject to acidic and microbial attacks. Both these types of attack can lead to a weakening and failure of the concretes, especially on the outer lip of the open side of the silage pit. Consequently, the development of an acid-resistant concrete that can extend the life span of silage bins on farms could lead to considerable cost savings for farmers and, hence, can improve farm productivity. This paper reports on test results of an investigation into the behaviour of concrete containing seawater-neutralised bauxite refinery residues (Bauxsol™) exposed to sulphuric acid environments in the laboratory and to silage effluents. The concrete manufactured had a fixed water–cement ratio of 0.55 and natural sand was replaced with the Bauxsol™ at 0%, 5%, 10%, 15% and 20% by cement mass. Results indicated that the use of Bauxsol™ as a sand replacement material improved the behaviour of concrete both in sulphuric acid in the laboratory as well as in the silage effluent. Consequently, it is concluded that the Bauxsol™ can be used to replace 10% of natural sand to produce concrete that is resistant to silage effluents, providing an extended service life over conventional concretes used in silage pits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The global increase in the penetration of renewable energy is pushing electrical power systems into uncharted territory, especially in terms of transient and dynamic stability. In particular, the greater penetration of wind generation in European power networks is, at times, displacing a significant capacity of conventional synchronous generation with fixed-speed induction generation and now more commonly, doubly fed induction generators. The impact of such changes in the generation mix requires careful monitoring to assess the impact on transient and dynamic stability. This study presents a measurement-based method for the early detection of power system oscillations, with consideration of mode damping, in order to raise alarms and develop strategies to actively improve power system dynamic stability and security. A method is developed based on wavelet-based support vector data description (SVDD) to detect oscillation modes in wind farm output power, which may excite dynamic instabilities in the wider system. The wavelet transform is used as a filter to identify oscillations in frequency bands, whereas the SVDD method is used to extract dominant features from different scales and generate an assessment boundary according to the extracted features. Poorly damped oscillations of a large magnitude, or that are resonant, can be alarmed to the system operator, to reduce the risk of system instability. The proposed method is exemplified using measured data from a chosen wind farm site.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increasing penetration of wind generation on the Island of Ireland has been accompanied by close investigation of low-frequency pulsations contained within active power flow. A primary concern is excitation of low-frequency oscillation modes already present on the system, particularly the 0.75 Hz mode as a consequence of interconnection between the Northern and Southern power system networks. In order to determine whether the prevalence of wind generation has a negative effect (excites modes) or positive impact (damping of modes) on the power system, oscillations must be measured and characterised. Using time – frequency methods, this paper presents work that has been conducted to extract features from low-frequency active power pulsations to determine the composition of oscillatory modes which may impact on dynamic stability. The paper proposes a combined wavelet-Prony method to extract modal components and determine damping factors. The method is exemplified using real data obtained from wind farm measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two commercially available adjuvants, Gerbu LQ 3000 and Montanide ISA 50V, were assessed as potential replacements for Freund's adjuvant by evaluating their efficacy in the production of polyclonal antibodies to veterinary drugs in rabbits. The aim was to find an adjuvant that could produce a similar (or enhanced) immune response in the host animal without the undesirable side effects associated with Freund's complete and incomplete adjuvant. The assessment involved the examination of each injection site and the characterisation of the resultant antibodies with regards to antibody titre and sensitivity. It was found that the rabbits immunised with Gerbu adjuvant produced some of the most sensitive antibodies. However, titres were relatively low and adverse effects at injection sites were relatively common. Montanide adjuvant produced no adverse effects and the related antibodies were found to be of adequate sensitivity when compared to those from rabbits immunised with Freund's. It was concluded that Montanide ISA 50V could be considered as a suitable replacement to Freund's for the production of polyclonal antibodies, to low molecular weight compounds in rabbits. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A range of polyclonal antibodies was successfully produced to the coccidiostatic drugs diclazuril and robenidine. Initial attempts to make immunogenic complexes of both drugs were ineffective due to difficulties encountered while trying to couple the compounds to large carrier proteins. Structural mimics, which could act as haptens for each drug, were sought and identified. The compounds identified were more open to chemical manipulation and were conjugated to carrier proteins to produce effective immunogens. The most sensitive antisera produced displayed IC(50)s of 1.5 ng/ml and 13 ng/ml for diclazuril and robenidine respectively. The antibody for diclazuril was shown to be specific, cross-reacting only with clazuril by 15%. The robenidine antibody displayed a low cross-reactivity of 1.2% to the compound used to produce the antibody. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper outlines the use of phasor measurement unit (PMU) records to validate models of fixed speed induction generator (FSIG)-based wind farms during frequency transients. Wind turbine manufacturers usually create their own proprietary models which they can supply to power system utilities for stability studies, subject to confidentiality agreements. However, it is desirable to confirm the accuracy of supplied models with measurements from the particular installation, in order to assess their validity under real field conditions. This is prudent due to possible changes in control algorithms and design retrofits, not accurately reflected or omitted in the supplied model. One important aspect of such models, especially for smaller power systems with limited inertia, is their accuracy during system frequency transients. This paper, therefore, assesses the accuracy of FSIG models with regard to frequency stability, and hence validates a subset of the model dynamics. Such models can then be used with confidence to assess wider system stability implications. The measured and simulated response of a wind farm using doubly fed induction generator (DFIG) technology is also assessed.